Skip to main content
Top
Published in: European Journal of Medical Research 1/2016

Open Access 01-12-2016 | Research

Is the distal radioulnar variance useful for identification of radial head prosthesis overlengthening? A cadaver study

Authors: Kilian Wegmann, Wei Zhang, Volker Strauss, Christian Ries, Lars P. Müller, Klaus J. Burkhart

Published in: European Journal of Medical Research | Issue 1/2016

Login to get access

Abstract

Background

Overlengthening by radial head prosthetic replacement leads to insufficient functionality and increased capitellar wear. It has been shown that in monopolar prostheses, the radial overlengthening by an overstuffed prosthesis leads to significant differences in the distal radioulnar variance at the wrist. This study evaluated ipsilateral ulnar variance as a predictor for overlengthening after implantation of a multipolar prosthesis.

Methods

The radial heads of seven fresh frozen upper extremities were resected and a multipolar radial head prosthesis was implanted. Thereafter, the native radioulnar variance at the wrist was documented via fluoroscopy. The alignment of the distal radioulnar joint in neutral, pronated and supinated rotational positions of the forearm was recorded fluoroscopically, and digital image analysis was performed regarding radioulnar shifting.

Results

Statistical analysis of the difference between native height and the manipulated states did not show consistent significant differences with stepwise overlengthening of +1.5, +3, +4.5 and +6 mm and with respect to rotational position of the forearm (p > 0.05). Interclass correlation coefficients showed excellent interobserver reliability (ICC 96 %), as did tests for intraobserver reliability (ICC 98–99 %).

Conclusions

No consistent influence of overlengthening on the alignment of the radius and ulna at the distal radioulnar joint was found after sequential overlengthening with a multipolar prosthesis. Maybe the ligamentous structures of the forearm prevent significant longitudinal dislocation of the radius, as the multipolar prosthesis gives way by at the radiocapitellar joint. According to the data of the present study, the ipsilateral wrist is not useful in diagnosing overlengthening of the radial column in multipolar prosthetic replacement of the radial head—in contrast to the reported results with monopolar prostheses.
Literature
1.
go back to reference Ring D, King G. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. Surgical technique. J Bone Joint Surg Am. 2008;90:63–73 (90 Suppl 2 Pt 1).PubMed Ring D, King G. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. Surgical technique. J Bone Joint Surg Am. 2008;90:63–73 (90 Suppl 2 Pt 1).PubMed
2.
go back to reference Moghaddam A, Lennert A, Studier-Fischer S, Wentzensen A, Zimmermann G. Prosthesis after comminuted radial head fractures: midterm results. Unfallchirurg. 2008;111(12):997–1004.CrossRefPubMed Moghaddam A, Lennert A, Studier-Fischer S, Wentzensen A, Zimmermann G. Prosthesis after comminuted radial head fractures: midterm results. Unfallchirurg. 2008;111(12):997–1004.CrossRefPubMed
3.
go back to reference Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ. Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes. J Bone Joint Surg Am. 2006;88(10):2192–200.CrossRefPubMed Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ. Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes. J Bone Joint Surg Am. 2006;88(10):2192–200.CrossRefPubMed
4.
go back to reference Doornberg JN, Parisien R, van Duijn PJ, Ring D. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. J Bone Joint Surg Am. 2007;89(5):1075–80.CrossRefPubMed Doornberg JN, Parisien R, van Duijn PJ, Ring D. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. J Bone Joint Surg Am. 2007;89(5):1075–80.CrossRefPubMed
5.
go back to reference Burkhart KJ, Mattyasovszky SG, Runkel M, Schwarz C, Kuchle R, Hessmann MH, et al. Mid- to long-term results after bipolar radial head arthroplasty. J Shoulder Elbow Surg. 2010;19(7):965–72.CrossRefPubMed Burkhart KJ, Mattyasovszky SG, Runkel M, Schwarz C, Kuchle R, Hessmann MH, et al. Mid- to long-term results after bipolar radial head arthroplasty. J Shoulder Elbow Surg. 2010;19(7):965–72.CrossRefPubMed
6.
go back to reference Weber O, Kabir K, Gravius S, Burger C, Wirtz D. Behandlungsergebnisse nach postprimärer Versorgung von Ellenbogenverletzungen mit einer Radiuskopfprothese. Obere Extremität. 2008;3(3):136–42.CrossRef Weber O, Kabir K, Gravius S, Burger C, Wirtz D. Behandlungsergebnisse nach postprimärer Versorgung von Ellenbogenverletzungen mit einer Radiuskopfprothese. Obere Extremität. 2008;3(3):136–42.CrossRef
7.
go back to reference Burkhart K, Mattyasovszky SG, Runkel M, Schwarz C, Rump A, Kuechle R, et al. Klinische und radiologische Ergebnisse nach bipolarer Radiuskopfprothese. Obere Extremität. 2011;6(2):108–14.CrossRef Burkhart K, Mattyasovszky SG, Runkel M, Schwarz C, Rump A, Kuechle R, et al. Klinische und radiologische Ergebnisse nach bipolarer Radiuskopfprothese. Obere Extremität. 2011;6(2):108–14.CrossRef
8.
go back to reference Hackl M, Wegmann K, Helf C, Neiss WF, Müller LP, Burkhart KJ. Accuracy of fit of monopolar radial head prostheses in the proximal radioulnar joint. Obere Extremität. 2015;10:246–51.CrossRef Hackl M, Wegmann K, Helf C, Neiss WF, Müller LP, Burkhart KJ. Accuracy of fit of monopolar radial head prostheses in the proximal radioulnar joint. Obere Extremität. 2015;10:246–51.CrossRef
9.
go back to reference Van Glabbeek F, van Riet RP, Baumfeld JA, Neale PG, O’Driscoll SW, Morrey BF, et al. The kinematic importance of radial neck length in radial head replacement. Med Eng Phys. 2005;27(4):336–42.CrossRefPubMed Van Glabbeek F, van Riet RP, Baumfeld JA, Neale PG, O’Driscoll SW, Morrey BF, et al. The kinematic importance of radial neck length in radial head replacement. Med Eng Phys. 2005;27(4):336–42.CrossRefPubMed
10.
go back to reference Van Glabbeek F, Van Riet RP, Baumfeld JA, Neale PG, O’Driscoll SW, Morrey BF, et al. Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg Am. 2004;86-A(12):2629–35.PubMed Van Glabbeek F, Van Riet RP, Baumfeld JA, Neale PG, O’Driscoll SW, Morrey BF, et al. Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg Am. 2004;86-A(12):2629–35.PubMed
11.
go back to reference Birkedal JP, Deal DN, Ruch DS. Loss of flexion after radial head replacement. J Shoulder Elbow Surg. 2004;13(2):208–13.CrossRefPubMed Birkedal JP, Deal DN, Ruch DS. Loss of flexion after radial head replacement. J Shoulder Elbow Surg. 2004;13(2):208–13.CrossRefPubMed
12.
go back to reference van Riet RP, van Glabbeek F, Verborgt O, Gielen J. Capitellar erosion caused by a metal radial head prosthesis. A case report. J Bone Joint Surg Am. 2004;86-A(5):1061–4.PubMed van Riet RP, van Glabbeek F, Verborgt O, Gielen J. Capitellar erosion caused by a metal radial head prosthesis. A case report. J Bone Joint Surg Am. 2004;86-A(5):1061–4.PubMed
13.
go back to reference van Riet RP, Sanchez-Sotelo J, Morrey BF. Failure of metal radial head replacement. J Bone Joint Surg Br. 2010;92(5):661–7.CrossRefPubMed van Riet RP, Sanchez-Sotelo J, Morrey BF. Failure of metal radial head replacement. J Bone Joint Surg Br. 2010;92(5):661–7.CrossRefPubMed
14.
go back to reference van Riet RP, van Glabbeek F, de Weerdt W, Oemar J, Bortier H. Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: a cadaver study. J Bone Joint Surg Br. 2007;89(3):413–6.CrossRefPubMed van Riet RP, van Glabbeek F, de Weerdt W, Oemar J, Bortier H. Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: a cadaver study. J Bone Joint Surg Br. 2007;89(3):413–6.CrossRefPubMed
15.
go back to reference Doornberg JN, Linzel DS, Zurakowski D, Ring D. Reference points for radial head prosthesis size. J Hand Surg Am. 2006;31(1):53–7.CrossRefPubMed Doornberg JN, Linzel DS, Zurakowski D, Ring D. Reference points for radial head prosthesis size. J Hand Surg Am. 2006;31(1):53–7.CrossRefPubMed
16.
go back to reference Athwal GS, Rouleau DM, MacDermid JC, King GJ. Contralateral elbow radiographs can reliably diagnose radial head implant overlengthening. J Bone Joint Surg Am. 2011;93(14):1339–46.CrossRefPubMed Athwal GS, Rouleau DM, MacDermid JC, King GJ. Contralateral elbow radiographs can reliably diagnose radial head implant overlengthening. J Bone Joint Surg Am. 2011;93(14):1339–46.CrossRefPubMed
17.
go back to reference Moon JG, Hong JH, Bither N, Shon WY. Can ulnar variance be used to detect overstuffing after radial head arthroplasty? Clin Orthop Relat Res. 2014;472(2):727–31.CrossRefPubMedPubMedCentral Moon JG, Hong JH, Bither N, Shon WY. Can ulnar variance be used to detect overstuffing after radial head arthroplasty? Clin Orthop Relat Res. 2014;472(2):727–31.CrossRefPubMedPubMedCentral
18.
go back to reference Kocher T, editor. Textbook of Operative Surgery. 3rd ed. Adam and Charles Black: London, United Kingdom; 1911. Kocher T, editor. Textbook of Operative Surgery. 3rd ed. Adam and Charles Black: London, United Kingdom; 1911.
19.
go back to reference Frank SG, Grewal R, Johnson J, Faber KJ, King GJ, Athwal GS. Determination of correct implant size in radial head arthroplasty to avoid overlengthening. J Bone Joint Surg Am. 2009;91(7):1738–46.CrossRefPubMed Frank SG, Grewal R, Johnson J, Faber KJ, King GJ, Athwal GS. Determination of correct implant size in radial head arthroplasty to avoid overlengthening. J Bone Joint Surg Am. 2009;91(7):1738–46.CrossRefPubMed
20.
go back to reference Rowland AS, Athwal GS, MacDermid JC, King GJ. Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing. J Hand Surg Am. 2007;32(5):637–41.CrossRefPubMed Rowland AS, Athwal GS, MacDermid JC, King GJ. Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing. J Hand Surg Am. 2007;32(5):637–41.CrossRefPubMed
21.
go back to reference Shors HC, Gannon C, Miller MC, Schmidt CC, Baratz ME. Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg Am. 2008;33(3):335–9.CrossRefPubMed Shors HC, Gannon C, Miller MC, Schmidt CC, Baratz ME. Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg Am. 2008;33(3):335–9.CrossRefPubMed
24.
go back to reference Rabinowitz RS, Light TR, Havey RM, Gourineni P, Patwardhan AG, Sartori MJ, et al. The role of the interosseous membrane and triangular fibrocartilage complex in forearm stability. J Hand Surg Am. 1994;19(3):385–93.CrossRefPubMed Rabinowitz RS, Light TR, Havey RM, Gourineni P, Patwardhan AG, Sartori MJ, et al. The role of the interosseous membrane and triangular fibrocartilage complex in forearm stability. J Hand Surg Am. 1994;19(3):385–93.CrossRefPubMed
25.
go back to reference Birkbeck DP, Failla JM, Hoshaw SJ, Fyhrie DP, Schaffler M. The interosseous membrane affects load distribution in the forearm. J Hand Surg Am. 1997;22(6):975–80.CrossRefPubMed Birkbeck DP, Failla JM, Hoshaw SJ, Fyhrie DP, Schaffler M. The interosseous membrane affects load distribution in the forearm. J Hand Surg Am. 1997;22(6):975–80.CrossRefPubMed
26.
27.
go back to reference Lanting BA, Ferreira LM, Johnson JA, King GJ, Athwal GS. The effect of radial head implant length on radiocapitellar articular properties and load transfer within the forearm. J Orthop Trauma. 2014;28(6):348–53.CrossRefPubMed Lanting BA, Ferreira LM, Johnson JA, King GJ, Athwal GS. The effect of radial head implant length on radiocapitellar articular properties and load transfer within the forearm. J Orthop Trauma. 2014;28(6):348–53.CrossRefPubMed
28.
go back to reference Yian E, Steens W, Lingenfelter E, Schneeberger AG. Malpositioning of radial head prostheses: an in vitro study. J Shoulder Elbow Surg. 2008;17(4):663–70.CrossRefPubMed Yian E, Steens W, Lingenfelter E, Schneeberger AG. Malpositioning of radial head prostheses: an in vitro study. J Shoulder Elbow Surg. 2008;17(4):663–70.CrossRefPubMed
29.
go back to reference Fu E, Li G, Souer JS, Lozano-Calderon S, Herndon JH, Jupiter JB, et al. Elbow position affects distal radioulnar joint kinematics. J Hand Surg Am. 2009;34(7):1261–8.CrossRefPubMedPubMedCentral Fu E, Li G, Souer JS, Lozano-Calderon S, Herndon JH, Jupiter JB, et al. Elbow position affects distal radioulnar joint kinematics. J Hand Surg Am. 2009;34(7):1261–8.CrossRefPubMedPubMedCentral
Metadata
Title
Is the distal radioulnar variance useful for identification of radial head prosthesis overlengthening? A cadaver study
Authors
Kilian Wegmann
Wei Zhang
Volker Strauss
Christian Ries
Lars P. Müller
Klaus J. Burkhart
Publication date
01-12-2016
Publisher
BioMed Central
Published in
European Journal of Medical Research / Issue 1/2016
Electronic ISSN: 2047-783X
DOI
https://doi.org/10.1186/s40001-016-0196-y

Other articles of this Issue 1/2016

European Journal of Medical Research 1/2016 Go to the issue