Skip to main content
Top
Published in: European Journal of Medical Research 1/2015

Open Access 01-12-2015 | Research

Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical study

Authors: Maik Stiehler, Jens Goronzy, Stephan Kirschner, Albrecht Hartmann, Torsten Schäfer, Klaus-Peter Günther

Published in: European Journal of Medical Research | Issue 1/2015

Login to get access

Abstract

Background

The clinical outcome of hip resurfacing (HR) as a demanding surgical technique associated with a substantial learning curve depends on the position of the femoral component. The aim of the study was to investigate the effects of the level of surgical experience on computer-assisted imageless navigation concerning precision of femoral component positioning, notching, and oversizing rate, as well as operative time.

Methods

Three surgeons with different levels of experience in both HR and computer-assisted surgery (CAS) prepared the femoral heads of 54 synthetic femurs using the DuromTM Hip Resurfacing (Zimmer, Warsaw, IN, USA) system. Each surgeon prepared a total of 18 proximal femurs using the Navitrack® system (ORTHOsoft Inc., Montreal, Canada) or the conventional free-hand DuromTM K-wire positioning jig. The differences between planned and postoperative stem shaft angle (SSA) and anteversion angle in standardized x-rays were measured and the operative time, not including the time for calibrating the CAS-system, was documented. Notching was evaluated by the three surgeons in a randomized manner. Oversizing was determined by the difference of the preoperative determined cap and the cap size advised by the CAS-system.

Results

CAS significantly reduced the overall mean deviation between planned and postoperative SSA in comparison with the conventional procedure (mean ± SD, 1 ± 1.7° vs. 7.4 ± 4.4°, P <0.01) regardless of the surgeon’s level of experience. The incidence of either varus or valgus SSA deviations exceeding 5° were 1/27 for CAS and 15/27 for the conventional method, respectively (P <0.001), corresponding to a reduction by 97%. Using CAS, the rate of notching was reduced by 100%.

Conclusions

The accuracy of femoral HR component orientation is significantly increased by use of CAS regardless of the surgeon’s level of experience in our preclinical study. Thus, imageless computer-assisted navigation can be a valuable tool to improve implant positioning in HR for surgeons at any stage of their learning curve.
Literature
1.
go back to reference Prosser GH, Yates PJ, Wood DJ, Graves SE, de Steiger RN, Miller LN. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop. 2010;81:66–71.CrossRefPubMedCentralPubMed Prosser GH, Yates PJ, Wood DJ, Graves SE, de Steiger RN, Miller LN. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop. 2010;81:66–71.CrossRefPubMedCentralPubMed
2.
go back to reference Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide: AOA; 2012. Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide: AOA; 2012.
3.
go back to reference Amstutz HC, Campbell PA, Le Duff MJ. Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg Am. 2004;86-A:1874–7.PubMed Amstutz HC, Campbell PA, Le Duff MJ. Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg Am. 2004;86-A:1874–7.PubMed
4.
go back to reference Kim PR, Beaule PE, Laflamme GY, Dunbar M. Causes of early failure in a multicenter clinical trial of hip resurfacing. J Arthroplasty. 2008;23:44–9. Kim PR, Beaule PE, Laflamme GY, Dunbar M. Causes of early failure in a multicenter clinical trial of hip resurfacing. J Arthroplasty. 2008;23:44–9.
5.
go back to reference Hartmann A, Lutzner J, Kirschner S, Witzleb WC, Gunther KP. Do survival rate and serum ion concentrations 10 years after metal-on-metal hip resurfacing provide evidence for continued use? Clin Orthop Relat Res. 2012;470:3118–26.CrossRefPubMedCentralPubMed Hartmann A, Lutzner J, Kirschner S, Witzleb WC, Gunther KP. Do survival rate and serum ion concentrations 10 years after metal-on-metal hip resurfacing provide evidence for continued use? Clin Orthop Relat Res. 2012;470:3118–26.CrossRefPubMedCentralPubMed
6.
go back to reference De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291–7.CrossRefPubMed De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291–7.CrossRefPubMed
7.
go back to reference Langton DJ, Joyce TJ, Jameson SS, Lord J, Van OM, Holland JP, et al. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011;93:164–71.CrossRefPubMed Langton DJ, Joyce TJ, Jameson SS, Lord J, Van OM, Holland JP, et al. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011;93:164–71.CrossRefPubMed
8.
go back to reference Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty. 2004;19:78–83.CrossRefPubMed Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty. 2004;19:78–83.CrossRefPubMed
9.
go back to reference Papageorgiou I, Yin Z, Ladon D, Baird D, Lewis AC, Sood A, et al. Genotoxic effects of particles of surgical cobalt chrome alloy on human cells of different age in vitro. Mutat Res. 2007;619:45–58.CrossRefPubMed Papageorgiou I, Yin Z, Ladon D, Baird D, Lewis AC, Sood A, et al. Genotoxic effects of particles of surgical cobalt chrome alloy on human cells of different age in vitro. Mutat Res. 2007;619:45–58.CrossRefPubMed
10.
go back to reference Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J. Imageless computer assisted vs. conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop. 2011;35:331–9.CrossRefPubMedCentralPubMed Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J. Imageless computer assisted vs. conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop. 2011;35:331–9.CrossRefPubMedCentralPubMed
11.
go back to reference Leenders T, Vandevelde D, Mahieu G, Nuyts R. Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg. 2002;7:99–106.CrossRefPubMed Leenders T, Vandevelde D, Mahieu G, Nuyts R. Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg. 2002;7:99–106.CrossRefPubMed
12.
go back to reference Ganapathi M, Vendittoli PA, Lavigne M, Gunther KP. Femoral component positioning in hip resurfacing with and without navigation. Clin Orthop Relat Res. 2009;467:1341–7.CrossRefPubMedCentralPubMed Ganapathi M, Vendittoli PA, Lavigne M, Gunther KP. Femoral component positioning in hip resurfacing with and without navigation. Clin Orthop Relat Res. 2009;467:1341–7.CrossRefPubMedCentralPubMed
13.
go back to reference Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E. Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Joint Surg Am. 2004;86-A:2015–21.PubMed Beaule PE, Lee JL, Le Duff MJ, Amstutz HC, Ebramzadeh E. Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J Bone Joint Surg Am. 2004;86-A:2015–21.PubMed
14.
go back to reference Beaule PE, Dorey FJ, Le Duff MJ, Gruen T, Amstutz HC. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004;469:87–93.CrossRef Beaule PE, Dorey FJ, Le Duff MJ, Gruen T, Amstutz HC. Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clin Orthop Relat Res. 2004;469:87–93.CrossRef
15.
go back to reference Beaule PE, Campbell PA, Hoke R, Dorey F. Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study. J Bone Joint Surg Br. 2006;88:35–9.CrossRefPubMed Beaule PE, Campbell PA, Hoke R, Dorey F. Notching of the femoral neck during resurfacing arthroplasty of the hip: a vascular study. J Bone Joint Surg Br. 2006;88:35–9.CrossRefPubMed
16.
go back to reference Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–84.CrossRefPubMed Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–84.CrossRefPubMed
17.
go back to reference Klein M, Scherger B, Bernd H, Ostermann PA. Complications after hip resurfacing using the ASR prosthesis in patients with osteoarthritis. Z Orthop Unfall. 2008;146:179–84.PubMed Klein M, Scherger B, Bernd H, Ostermann PA. Complications after hip resurfacing using the ASR prosthesis in patients with osteoarthritis. Z Orthop Unfall. 2008;146:179–84.PubMed
18.
go back to reference Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br. 2005;87:463–4.CrossRefPubMed Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br. 2005;87:463–4.CrossRefPubMed
19.
20.
go back to reference Schnurr C, Nessler J, Meyer C, Schild HH, Koebke J, Konig DP. How accurate is image-free computer navigation for hip resurfacing arthroplasty? An anatomical investigation. J Orthop Sci. 2009;14:497–504.CrossRefPubMed Schnurr C, Nessler J, Meyer C, Schild HH, Koebke J, Konig DP. How accurate is image-free computer navigation for hip resurfacing arthroplasty? An anatomical investigation. J Orthop Sci. 2009;14:497–504.CrossRefPubMed
21.
go back to reference Resubal JR, Morgan DA. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:341–50.CrossRefPubMed Resubal JR, Morgan DA. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:341–50.CrossRefPubMed
22.
go back to reference Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: a cadaver study. J Bone Joint Surg Br. 2007;89:557–60.CrossRefPubMed Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: a cadaver study. J Bone Joint Surg Br. 2007;89:557–60.CrossRefPubMed
23.
go back to reference Stiehler M, Goronzy J, Hartmann A, Krummenauer F, Gunther KP. The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial. Int Orthop. 2013;37:569–81.CrossRefPubMedCentralPubMed Stiehler M, Goronzy J, Hartmann A, Krummenauer F, Gunther KP. The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial. Int Orthop. 2013;37:569–81.CrossRefPubMedCentralPubMed
24.
go back to reference Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA. Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. J Arthroplasty. 2007;22:66–71.CrossRefPubMed Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA. Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. J Arthroplasty. 2007;22:66–71.CrossRefPubMed
25.
go back to reference Cobb JP, Kannan V, Brust K, Thevendran G. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res. 2007;463:90–7.PubMed Cobb JP, Kannan V, Brust K, Thevendran G. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res. 2007;463:90–7.PubMed
26.
go back to reference Seyler TM, Lai LP, Sprinkle DI, Ward WG, Jinnah RH. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am. 2008;90 Suppl 3:71–80.CrossRefPubMed Seyler TM, Lai LP, Sprinkle DI, Ward WG, Jinnah RH. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am. 2008;90 Suppl 3:71–80.CrossRefPubMed
27.
go back to reference Olsen M, Davis ET, Waddell JP, Schemitsch EH. Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2009;91:310–5.CrossRefPubMed Olsen M, Davis ET, Waddell JP, Schemitsch EH. Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2009;91:310–5.CrossRefPubMed
Metadata
Title
Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing – a preclinical study
Authors
Maik Stiehler
Jens Goronzy
Stephan Kirschner
Albrecht Hartmann
Torsten Schäfer
Klaus-Peter Günther
Publication date
01-12-2015
Publisher
BioMed Central
Published in
European Journal of Medical Research / Issue 1/2015
Electronic ISSN: 2047-783X
DOI
https://doi.org/10.1186/s40001-015-0086-8

Other articles of this Issue 1/2015

European Journal of Medical Research 1/2015 Go to the issue