Skip to main content
Top
Published in: Israel Journal of Health Policy Research 1/2016

Open Access 01-12-2016 | Original research article

Introducing a change in hospital policy using FMEA methodology as a tool to reduce patient hazards

Authors: Fanny Ofek, Racheli Magnezi, Yaffa Kurzweil, Inbal Gazit, Sofia Berkovitch, Orna Tal

Published in: Israel Journal of Health Policy Research | Issue 1/2016

Login to get access

Abstract

Background

Intravenous potassium chloride (IV KCl) solutions are widely used in hospitals for treatment of hypokalemia. As ampoules of concentrated KCL must be diluted before use, critical incidents have been associated with its preparation and administration. Currently, we have introduced ready-to-use diluted KCl infusion solutions to minimize the use of high-alert concentrated KCl. Since this process may be associated with considerable risks, we embraced a proactive hazard analysis as a tool to implement a change in high-alert drug usage in a hospital setting.

Methods

Failure mode and effect analysis (FMEA) is a systematic tool to analyze and identify risks in system operations. We used FMEA to examine the hazards associated with the implementation of the ready-to-use solutions. A multidisciplinary team analyzed the risks by identifying failure modes, conducting a hazard analysis and calculating the criticality index (CI) for each failure mode. A 1-day survey was performed as an evaluation step after a trial run period of approximately 4 months.

Results

Six major possible risks were identified. The most severe risks were prioritized and specific recommendations were formulated. Out of 28 patients receiving IV KCl on the day of the survey, 22 received the ready-to-use solutions and 6 received the concentrated solutions as instructed. Only 1 patient received inappropriate ready-to-use KCl.

Conclusions

Using the FMEA tool in our study has proven once again that by creating a gradient of severity of potential vulnerable elements, we are able to proactively promote safer and more efficient processes in health care systems. This article presents a utilization of this method for implementing a change in hospital policy regarding the routine use of IV KCl.
Literature
1.
go back to reference Prescribing information 2010. Concentrated sterile solution of 14.9 % potassium chloride injection. Melsungen, Germany: B Braun Melsungen AG; 2010. Prescribing information 2010. Concentrated sterile solution of 14.9 % potassium chloride injection. Melsungen, Germany: B Braun Melsungen AG; 2010.
2.
go back to reference Alfonzo AV, Isles C, Geddes C, Deighan C. Potassium disorders - clinical spectrum and emergency management. Resuscitation. 2006;70:10–25.CrossRefPubMed Alfonzo AV, Isles C, Geddes C, Deighan C. Potassium disorders - clinical spectrum and emergency management. Resuscitation. 2006;70:10–25.CrossRefPubMed
4.
go back to reference Hamill RJ, Robinson LM, Wexler HR, Moote C. Efficacy and safety of potassium infusion therapy in hypokalemic critically ill patients. Crit Care Med. 1991;19:694–9.CrossRefPubMed Hamill RJ, Robinson LM, Wexler HR, Moote C. Efficacy and safety of potassium infusion therapy in hypokalemic critically ill patients. Crit Care Med. 1991;19:694–9.CrossRefPubMed
5.
go back to reference World Health Organization Collaborating Centre for Patient Safety Solutions. Control of concentrated electrolyte solutions. Patient Safety Solutions. 2007;1:1–3.CrossRef World Health Organization Collaborating Centre for Patient Safety Solutions. Control of concentrated electrolyte solutions. Patient Safety Solutions. 2007;1:1–3.CrossRef
6.
go back to reference Reeve JF, Allinson YM. High-risk medication alert: intravenous KCl. Aust Prescr. 2005;28:14–6.CrossRef Reeve JF, Allinson YM. High-risk medication alert: intravenous KCl. Aust Prescr. 2005;28:14–6.CrossRef
7.
go back to reference David U, Hyland S. Medication safety alerts. Can J Hosp Pharm. 2002;55:278–80. David U, Hyland S. Medication safety alerts. Can J Hosp Pharm. 2002;55:278–80.
8.
go back to reference Intravenous KCl can be fatal if given inappropriately. Safety and Quality Council (Australia) Medication Alert; 2003 Intravenous KCl can be fatal if given inappropriately. Safety and Quality Council (Australia) Medication Alert; 2003
9.
go back to reference Concentrated KCl: a recurring danger. ISMP Canada Safety Bulletin; 2004:4. Concentrated KCl: a recurring danger. ISMP Canada Safety Bulletin; 2004:4.
10.
go back to reference Prescribing information 2007. Intravenous injections in plastic bags. Ashdod, Israel: Teva Medical Ltd; 2007. Prescribing information 2007. Intravenous injections in plastic bags. Ashdod, Israel: Teva Medical Ltd; 2007.
11.
go back to reference Hoyland A, Rausand M. System reliability theory. Model Stat Methods. 2004;88. Hoyland A, Rausand M. System reliability theory. Model Stat Methods. 2004;88.
12.
go back to reference Joint Commission Resources. Joint Commission International. Failure Mode and Effects Analysis in Health Care: Proactive Risk Reduction, 3rd ed. llinois, Oakbrook Terrace 60181, USA: Joint Commission Resources; 2010. Joint Commission Resources. Joint Commission International. Failure Mode and Effects Analysis in Health Care: Proactive Risk Reduction, 3rd ed. llinois, Oakbrook Terrace 60181, USA: Joint Commission Resources; 2010.
13.
go back to reference Automotive Industry Action Group. Potential Failure Mode and Effect Analysis (FMEA), 4th ed. Michigan, Southfield MI48033-7100, USA: AIAG; 2008 Automotive Industry Action Group. Potential Failure Mode and Effect Analysis (FMEA), 4th ed. Michigan, Southfield MI48033-7100, USA: AIAG; 2008
15.
go back to reference Wetterneck TB, Skibinski KA, Roberts TL, Kleppin SM, Schroeder ME, Enloe M, et al. Using failure mode and effects analysis to plan implementation of smart i.v. pump technology. Am J Health Syst Pharm. 2006;63:1528–38.CrossRefPubMed Wetterneck TB, Skibinski KA, Roberts TL, Kleppin SM, Schroeder ME, Enloe M, et al. Using failure mode and effects analysis to plan implementation of smart i.v. pump technology. Am J Health Syst Pharm. 2006;63:1528–38.CrossRefPubMed
16.
go back to reference Arenas Villafranca JJ, Gómez Sánchez A, Nieto Guindo M, Felipe V. Using failure mode and effects analysis to improve the safety of neonatal parenteral nutrition. Am J Health Syst Pharm. 2014;71:1210–8.CrossRefPubMed Arenas Villafranca JJ, Gómez Sánchez A, Nieto Guindo M, Felipe V. Using failure mode and effects analysis to improve the safety of neonatal parenteral nutrition. Am J Health Syst Pharm. 2014;71:1210–8.CrossRefPubMed
Metadata
Title
Introducing a change in hospital policy using FMEA methodology as a tool to reduce patient hazards
Authors
Fanny Ofek
Racheli Magnezi
Yaffa Kurzweil
Inbal Gazit
Sofia Berkovitch
Orna Tal
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Israel Journal of Health Policy Research / Issue 1/2016
Electronic ISSN: 2045-4015
DOI
https://doi.org/10.1186/s13584-016-0090-7

Other articles of this Issue 1/2016

Israel Journal of Health Policy Research 1/2016 Go to the issue