Published in: Journal of Medical Case Reports 1/2015

Open Access 01-12-2015 | Case report

Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report

Authors: Junko Nakahira, Hisanari Ishii, Toshiyuki Sawai, Toshiaki Minami

Published in: Journal of Medical Case Reports | Issue 1/2015

Login to get access

Abstract

Introduction

Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient’s aortic valve immediately after aortic declamping.

Case presentation

A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery.

Conclusions

Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.
Appendix
Available only for authorised users
Literature
1.
go back to reference Adams MS, Alston TA, Walker JD. Detection of an ill-poised thread of lint by transesophageal echocardiography after aortic valve replacement. Anesth Analg. 2006;103:40.CrossRefPubMed Adams MS, Alston TA, Walker JD. Detection of an ill-poised thread of lint by transesophageal echocardiography after aortic valve replacement. Anesth Analg. 2006;103:40.CrossRefPubMed
2.
go back to reference Fischi M, Narins CR. Coronary embolization of a gauze fragment: a cautionary case report. Catheter Cardiovasc Interv. 2005;66:570–2.CrossRefPubMed Fischi M, Narins CR. Coronary embolization of a gauze fragment: a cautionary case report. Catheter Cardiovasc Interv. 2005;66:570–2.CrossRefPubMed
3.
go back to reference Sawai T, Nakahira J, Shimoyama Y, Oka M, Imanaka H, Minami T. Prosthetic valve malfunction caused by chordal entrapment detected by transesophageal echocardiography. J Cardiothorac Vasc Anesth. 2011;25:495–7.CrossRefPubMed Sawai T, Nakahira J, Shimoyama Y, Oka M, Imanaka H, Minami T. Prosthetic valve malfunction caused by chordal entrapment detected by transesophageal echocardiography. J Cardiothorac Vasc Anesth. 2011;25:495–7.CrossRefPubMed
4.
go back to reference Gillham MJ, Tousignant CP. Diagnosis by intraoperative transesophageal echocardiography of acute thrombosis of mechanical aortic valve prosthesis associated with the use of biological glue. Anesth Analg. 2001;92:1123–5.CrossRefPubMed Gillham MJ, Tousignant CP. Diagnosis by intraoperative transesophageal echocardiography of acute thrombosis of mechanical aortic valve prosthesis associated with the use of biological glue. Anesth Analg. 2001;92:1123–5.CrossRefPubMed
5.
go back to reference Birmingham B. TEE diagnosis of mechanical AVR dysfunction associated with biological glue. Anesth Analg. 2001;93:1627–8.CrossRefPubMed Birmingham B. TEE diagnosis of mechanical AVR dysfunction associated with biological glue. Anesth Analg. 2001;93:1627–8.CrossRefPubMed
6.
go back to reference Trivi M, Albertal J, Vaccarino G, Albertal M, Navia D. Ostial stenosis after Bentall technique using glue: percutaneous stenting may be ineffective. Interact Cardiovasc Thorac Surg. 2007;6:511–3.CrossRefPubMed Trivi M, Albertal J, Vaccarino G, Albertal M, Navia D. Ostial stenosis after Bentall technique using glue: percutaneous stenting may be ineffective. Interact Cardiovasc Thorac Surg. 2007;6:511–3.CrossRefPubMed
8.
go back to reference Sidhu S, Goyer C, Hatzakorzian R, Olivier JF, Devarennes B, Cote AV, et al. Transesophageal echocardiographic detection of intracardiac BioGlue postmitral valve replacement. Anesth Analg. 2007;105:1572–3.CrossRefPubMed Sidhu S, Goyer C, Hatzakorzian R, Olivier JF, Devarennes B, Cote AV, et al. Transesophageal echocardiographic detection of intracardiac BioGlue postmitral valve replacement. Anesth Analg. 2007;105:1572–3.CrossRefPubMed
9.
go back to reference Alvarez RJ, Quiroga SJ, de Alegria MA, Dominguez DC. Pulmonary embolism due to biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2011;12:650–1.CrossRef Alvarez RJ, Quiroga SJ, de Alegria MA, Dominguez DC. Pulmonary embolism due to biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2011;12:650–1.CrossRef
10.
go back to reference Fletcher NS, Mandal K, Jahangiri M. Surgical glue resembling left atrial thrombus. Interact Cardiovasc Thorac Surg. 2004;3:409–10.CrossRefPubMed Fletcher NS, Mandal K, Jahangiri M. Surgical glue resembling left atrial thrombus. Interact Cardiovasc Thorac Surg. 2004;3:409–10.CrossRefPubMed
11.
go back to reference Bernabeu E, Castellá M, Barriuso C, Mulet J. Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2005;4:329–31.CrossRefPubMed Bernabeu E, Castellá M, Barriuso C, Mulet J. Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2005;4:329–31.CrossRefPubMed
Metadata
Title
Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report
Authors
Junko Nakahira
Hisanari Ishii
Toshiyuki Sawai
Toshiaki Minami
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2015
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-014-0512-5