Skip to main content
Top
Published in: Trials 1/2015

Open Access 01-12-2015 | Study protocol

Evaluating the use of fibrin glue for sealing low-output enterocutaneous fistulas: study protocol for a randomized controlled trial

Authors: Xiuwen Wu, Jianan Ren, Gefei Wang, Jianzhong Wang, Feng Wang, Yueping Fan, Yuanxin Li, Gang Han, Yanbing Zhou, Xiaofei Song, Bin Quan, Min Yao, Jieshou Li

Published in: Trials | Issue 1/2015

Login to get access

Abstract

Background

The management of an enterocutaneous fistula poses a significant challenge to surgeons and is often associated with a costly hospital stay and long-term discomfort. The use of fibrin glue in the fistula tract has been shown to promote closure of low output enterocutaneous fistulas. Our previous nonrandomized study demonstrated that autologous platelet-rich fibrin glue treatment significantly decreased time to fistula closure and promoted closure rates. However, there are several limitations in the study, which may lead to bias in our conclusion. Thus, a multicenter, randomized, controlled clinical trial is required.

Methods/Design

The study is designed as a randomized, open-label, three-arm, multicenter study in nine Chinese academic hospitals for evaluating the efficacy and safety of fibrin glue for sealing low-output fistulas. An established number of 171 fistula patients will undergo prospective random assignment to autologous fibrin glue, commercial porcine fibrin sealants or drainage cessation (1:1:1). The primary endpoint is fistula closure time (defined as the interval between the day of enrollment and day of fistula closure) during the 14-day treatment period.

Discussion

To our knowledge, this is the first study to evaluate the safety and efficacy of both autologous and commercial fibrin glue sealing for patients with low-output volume fistulas.

Trial registration

NCT01828892. Registration date: April 2013.
Appendix
Available only for authorised users
Literature
1.
2.
3.
4.
go back to reference Wainstein DE, Fernandez E, Gonzalez D, Chara O, Berkowski D. Treatment of high-output enterocutaneous fistulas with a vacuum-compaction device. A ten-year experience. World J Surg. 2008;32:430–5.CrossRefPubMed Wainstein DE, Fernandez E, Gonzalez D, Chara O, Berkowski D. Treatment of high-output enterocutaneous fistulas with a vacuum-compaction device. A ten-year experience. World J Surg. 2008;32:430–5.CrossRefPubMed
5.
go back to reference Rabago LR, Ventosa N, Castro JL, Marco J, Herrera N, Gea F. Endoscopic treatment of postoperative fistulas resistant to conservative management using biological fibrin glue. Endoscopy. 2002;34:632–8.CrossRefPubMed Rabago LR, Ventosa N, Castro JL, Marco J, Herrera N, Gea F. Endoscopic treatment of postoperative fistulas resistant to conservative management using biological fibrin glue. Endoscopy. 2002;34:632–8.CrossRefPubMed
6.
go back to reference Del Rio P, Dell’Abate P, Soliani P, Ziegler S, Arcuri M, Sianesi M. Endoscopic treatment of esophageal and colo-rectal fistulas with fibrin glue. Acta Biomed. 2005;76:95–8.PubMed Del Rio P, Dell’Abate P, Soliani P, Ziegler S, Arcuri M, Sianesi M. Endoscopic treatment of esophageal and colo-rectal fistulas with fibrin glue. Acta Biomed. 2005;76:95–8.PubMed
7.
go back to reference Hwang TL, Chen MF. Randomized trial of fibrin tissue glue for low output enterocutaneous fistula. Brit J Surg. 1996;83:112.CrossRefPubMed Hwang TL, Chen MF. Randomized trial of fibrin tissue glue for low output enterocutaneous fistula. Brit J Surg. 1996;83:112.CrossRefPubMed
8.
go back to reference Ramón Rábago L, Moral I, Delgado M, Guerra I, Quintanilla E, Castro JL, et al. Endoscopic treatment of gastrointestinal fistulas with biological fibrin glue. Gastroenterol Hepatol. 2006;29:390–6.CrossRefPubMed Ramón Rábago L, Moral I, Delgado M, Guerra I, Quintanilla E, Castro JL, et al. Endoscopic treatment of gastrointestinal fistulas with biological fibrin glue. Gastroenterol Hepatol. 2006;29:390–6.CrossRefPubMed
9.
go back to reference Avalos-González J, Portilla-deBuen E, Leal-Cortés CA, Orozco-Mosqueda A, Estrada-Aguilar Mdel C, Velázquez-Ramírez GA, et al. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant. World J Gastroenterol. 2010;16:2793–800.CrossRefPubMedPubMedCentral Avalos-González J, Portilla-deBuen E, Leal-Cortés CA, Orozco-Mosqueda A, Estrada-Aguilar Mdel C, Velázquez-Ramírez GA, et al. Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant. World J Gastroenterol. 2010;16:2793–800.CrossRefPubMedPubMedCentral
10.
go back to reference Lippert E, Klebl FH, Schweller F, Ott C, Gelbmann CM, Schölmerich J, et al. Fibrin glue in the endoscopic treatment of fistulae and anastomotic leakages of the gastrointestinal tract. Int J Colorectal Dis. 2011;26:303–11.CrossRefPubMed Lippert E, Klebl FH, Schweller F, Ott C, Gelbmann CM, Schölmerich J, et al. Fibrin glue in the endoscopic treatment of fistulae and anastomotic leakages of the gastrointestinal tract. Int J Colorectal Dis. 2011;26:303–11.CrossRefPubMed
11.
go back to reference Horowitz B, Busch M. Estimating the pathogen safety of manufactured human plasma products: application to fibrin sealants and to thrombin. Transfusion. 2008;48:1739–53.CrossRefPubMed Horowitz B, Busch M. Estimating the pathogen safety of manufactured human plasma products: application to fibrin sealants and to thrombin. Transfusion. 2008;48:1739–53.CrossRefPubMed
12.
go back to reference Wu X, Ren J, Yao G, Zhou B, Wang G, Gu G, et al. Biocompatibility, biodegradation and neovascularization of human single-unit platelet-rich fibrin glue: an in vivo analysis. Chin Med J. 2014;127:408–11.PubMed Wu X, Ren J, Yao G, Zhou B, Wang G, Gu G, et al. Biocompatibility, biodegradation and neovascularization of human single-unit platelet-rich fibrin glue: an in vivo analysis. Chin Med J. 2014;127:408–11.PubMed
13.
go back to reference Wu X, Ren J, Gu G, Wang G, Han G, Zhou B, et al. Autologous platelet rich fibrin glue for sealing of low-output enterocutaneous fistulas: an observational cohort study. Surgery. 2014;155:434–41.CrossRefPubMed Wu X, Ren J, Gu G, Wang G, Han G, Zhou B, et al. Autologous platelet rich fibrin glue for sealing of low-output enterocutaneous fistulas: an observational cohort study. Surgery. 2014;155:434–41.CrossRefPubMed
14.
go back to reference Wu X, Ren J, Luan J, Yao G, Li J. Biochemical, mechanical, and morphological properties of a completely autologous platelet-rich wound sealant. Blood Coagul Fibrinolysis. 2012;23:290–5.CrossRefPubMed Wu X, Ren J, Luan J, Yao G, Li J. Biochemical, mechanical, and morphological properties of a completely autologous platelet-rich wound sealant. Blood Coagul Fibrinolysis. 2012;23:290–5.CrossRefPubMed
15.
go back to reference Thorn JJ, Sorensen H, Weis-Fogh U, Andersen M. Autologous fibrin glue with growth factors in reconstructive maxillofacial surgery. Int J Oral Maxillofac Surg. 2004;33:95–100.CrossRefPubMed Thorn JJ, Sorensen H, Weis-Fogh U, Andersen M. Autologous fibrin glue with growth factors in reconstructive maxillofacial surgery. Int J Oral Maxillofac Surg. 2004;33:95–100.CrossRefPubMed
16.
go back to reference Ren J, Wu X, Wang G, Chen J, Gu G, Li J. Fistula fiberscope-assisted percutaneous glue sealing for enterocutaneous fistulas: a case report. Surg Laparosc Endosc Percutan Tech. 2013;23:e235–6.CrossRefPubMed Ren J, Wu X, Wang G, Chen J, Gu G, Li J. Fistula fiberscope-assisted percutaneous glue sealing for enterocutaneous fistulas: a case report. Surg Laparosc Endosc Percutan Tech. 2013;23:e235–6.CrossRefPubMed
17.
go back to reference Lee WY, Park KJ, Cho YB, Yoon SN, Song KH, Kim Do S, et al. Autologous adipose tissue-derived stem cells treatment demonstrated favorable and sustainable therapeutic effect for crohn’s fistula. Stem Cells. 2013;31:2575–81.CrossRefPubMed Lee WY, Park KJ, Cho YB, Yoon SN, Song KH, Kim Do S, et al. Autologous adipose tissue-derived stem cells treatment demonstrated favorable and sustainable therapeutic effect for crohn’s fistula. Stem Cells. 2013;31:2575–81.CrossRefPubMed
18.
go back to reference World Medical Association. World Medical Association Declaration of Helsinki. Ethical principles for medical research involving human subjects. Bull World Health Organ. 2001;79:373–4.PubMedCentral World Medical Association. World Medical Association Declaration of Helsinki. Ethical principles for medical research involving human subjects. Bull World Health Organ. 2001;79:373–4.PubMedCentral
20.
go back to reference Council for International Organizations of Medical Sciences. International ethical guidelines for biomedical research involving human subjects. Bull Med Ethics. 2002;182:17–23. Council for International Organizations of Medical Sciences. International ethical guidelines for biomedical research involving human subjects. Bull Med Ethics. 2002;182:17–23.
Metadata
Title
Evaluating the use of fibrin glue for sealing low-output enterocutaneous fistulas: study protocol for a randomized controlled trial
Authors
Xiuwen Wu
Jianan Ren
Gefei Wang
Jianzhong Wang
Feng Wang
Yueping Fan
Yuanxin Li
Gang Han
Yanbing Zhou
Xiaofei Song
Bin Quan
Min Yao
Jieshou Li
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Trials / Issue 1/2015
Electronic ISSN: 1745-6215
DOI
https://doi.org/10.1186/s13063-015-0966-9

Other articles of this Issue 1/2015

Trials 1/2015 Go to the issue