Excerpt

We read with great interest the article by Drs. Robba and Taccone [1]. We agree completely with the versatility of transcranial Doppler (TCD) ultrasound in the neurointensive care unit (NeuroICU) population and similarly employ it for its uses for aneurysmal subarachnoid hemorrhage, brain death, and circulatory arrest, and as a noninvasive surrogate for intracranial compliance and elastance [2]. We feel the authors’ work is important, especially at a time when TCD seems to be falling out of favor in some NeuroICUs and guidelines. However, we find this ironic, since there is a rise in general critical care ultrasound given its noninvasive utility without ionizing radiation risk compared to computed tomography-based methods of diagnostic evaluation of chest and abdominal body cavities. In our experience, TCD (both blind methods with Spencer ST3 machines, for example) and TCD-imaging methods are useful in the NeuroICU, with 2 major technical caveats: the need for (1) adequate ultrasonographic skills of acquiring imaging and (2) adequate training in interpretation of all features on TCD imaging, including the pulsatility index (i.e., Gosling) and resistance indices (e.g., Pourcelot) [3]. In some cases, teleneurosonology can be performed assuming the 2 caveats above are in place [4]. The most common reason we see for lack of adoption of TCD in intensive care/NeuroICU practice is the lack of these 2 elements. Finally, we note the word “vasospasm” is missing an “s” in Fig. 1, but overall, we commend the authors for their nice summary of TCD use. …
Literature
2.
go back to reference Freeman WD. Management of intracranial pressure. Continuum (Minneap Minn). 2015;21:1299–323. Freeman WD. Management of intracranial pressure. Continuum (Minneap Minn). 2015;21:1299–323.
3.
go back to reference Sierra J, Hanel R, Mooney L, Freeman W. Differential considerations of TCD pulsatility (Gosling’s) and resistance (Pourcelot) indices after AVM surgery. J Vasc Interv Neurol. 2014;7:41–3.PubMedPubMedCentral Sierra J, Hanel R, Mooney L, Freeman W. Differential considerations of TCD pulsatility (Gosling’s) and resistance (Pourcelot) indices after AVM surgery. J Vasc Interv Neurol. 2014;7:41–3.PubMedPubMedCentral
4.
go back to reference Rubin MN, Barrett KM, Freeman WD, Lee Iannotti JK, Channer DD, Rabinstein AA, Demaerschalk BM. Teleneurosonology: a novel application of transcranial and carotid ultrasound. J Stroke Cerebrovasc Dis. 2015;24:562–5.CrossRef Rubin MN, Barrett KM, Freeman WD, Lee Iannotti JK, Channer DD, Rabinstein AA, Demaerschalk BM. Teleneurosonology: a novel application of transcranial and carotid ultrasound. J Stroke Cerebrovasc Dis. 2015;24:562–5.CrossRef
Metadata
Title
How I use transcranial Doppler in the ICU
Authors
Chidinma L. Onweni
Diane C. McLaughlin
William D. Freeman
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2020
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-020-2750-9

Other articles of this Issue 1/2020

Critical Care 1/2020 Go to the issue