Abstract

Background

Unicompartmental knee arthroplasty is an established treatment option for anteromedial osteoarthritis. However, large registry studies report higher rates of aseptic loosening compared to total knee arthroplasty. The objective of this study was to assess the impact of bone density on morphological cement penetration. Moreover, an alternative regional bone density measuring technique was validated against the established bone mineral density assessment.

Methods

Components were implanted on the medial side of 18 fresh-frozen cadaver knees using a minimally invasive approach. Bone density has been quantified prior to implantation using Hounsfield units and bone mineral density. Morphological cement penetration has been assessed in different areas and was correlated with local bone density.

Findings

A highly significant correlation between Hounsfield units and trabecular bone mineral density was detected (r = 0.93; P < 0.0001), and local bone density was significantly increased in the anterior and posterior area (P = 0.0003). The mean cement penetration depth was 1.5 (SD 0.5 mm), and cement intrusion into trabecular bone was interrupted in 31.8% (SD 23.7%) of the bone-cement interface. Bone density was correlated significantly negative with penetration depth (r = − 0.31; P = 0.023) and positive with interruptions of horizontal interdigitating (r = + 0.33; P = 0.014). Cement penetration around the anchoring peg was not significantly correlated with bone density.

Interpretation

Areas with high bone density were characterized by significantly lower penetration depths and significantly higher areas without cement penetration. Anchoring pegs facilitate cement intrusion mechanically. Regional quantification of bone density using Hounsfield units is a simple but valuable extension to the established determination of bone mineral density.
Literature
1.
go back to reference Robertsson O, Borgquist L, Knutson K, Lewold S, Lidgren L. Use of unicompartmental instead of tricompartmental prostheses for unicompartmental arthrosis in the knee is a cost-effective alternative. 15,437 primary tricompartmental prostheses were compared with 10,624 primary medial or lateral unicompartmental prostheses. Acta Orthop Scand. 1999;70(2):170–5.PubMedCrossRef Robertsson O, Borgquist L, Knutson K, Lewold S, Lidgren L. Use of unicompartmental instead of tricompartmental prostheses for unicompartmental arthrosis in the knee is a cost-effective alternative. 15,437 primary tricompartmental prostheses were compared with 10,624 primary medial or lateral unicompartmental prostheses. Acta Orthop Scand. 1999;70(2):170–5.PubMedCrossRef
2.
go back to reference Mohammad HR, Strickland L, Hamilton TW, Murray DW. Long-term outcomes of over 8,000 medial Oxford Phase 3 Unicompartmental Knees-a systematic review. Acta Orthop. 2018;89(1):101–7.PubMedCrossRef Mohammad HR, Strickland L, Hamilton TW, Murray DW. Long-term outcomes of over 8,000 medial Oxford Phase 3 Unicompartmental Knees-a systematic review. Acta Orthop. 2018;89(1):101–7.PubMedCrossRef
3.
go back to reference Inacio MCS, Paxton EW, Graves SE, Namba RS, Nemes S. Projected increase in total knee arthroplasty in the United States - an alternative projection model. Osteoarthr Cartil. 2017;25(11):1797–803.PubMedCrossRef Inacio MCS, Paxton EW, Graves SE, Namba RS, Nemes S. Projected increase in total knee arthroplasty in the United States - an alternative projection model. Osteoarthr Cartil. 2017;25(11):1797–803.PubMedCrossRef
4.
go back to reference Brown NM, Sheth NP, Davis K, Berend ME, Lombardi AV, Berend KR, Della Valle CJ. Total knee arthroplasty has higher postoperative morbidity than unicompartmental knee arthroplasty: a multicenter analysis. J Arthroplast. 2012;27(8 Suppl):86–90.CrossRef Brown NM, Sheth NP, Davis K, Berend ME, Lombardi AV, Berend KR, Della Valle CJ. Total knee arthroplasty has higher postoperative morbidity than unicompartmental knee arthroplasty: a multicenter analysis. J Arthroplast. 2012;27(8 Suppl):86–90.CrossRef
5.
go back to reference Ghomrawi HM, Eggman AA, Pearle AD. Effect of age on cost-effectiveness of unicompartmental knee arthroplasty compared with total knee arthroplasty in the U.S. J Bone Joint Surg Am. 2015;97(5):396–402.PubMedPubMedCentralCrossRef Ghomrawi HM, Eggman AA, Pearle AD. Effect of age on cost-effectiveness of unicompartmental knee arthroplasty compared with total knee arthroplasty in the U.S. J Bone Joint Surg Am. 2015;97(5):396–402.PubMedPubMedCentralCrossRef
6.
go back to reference Kim KT, Lee S, Lee JI, Kim JW. Analysis and treatment of complications after unicompartmental knee arthroplasty. Knee Surg Relat Res. 2016;28(1):46–54.PubMedPubMedCentralCrossRef Kim KT, Lee S, Lee JI, Kim JW. Analysis and treatment of complications after unicompartmental knee arthroplasty. Knee Surg Relat Res. 2016;28(1):46–54.PubMedPubMedCentralCrossRef
7.
go back to reference Epinette JA, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for H, Knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.PubMedCrossRef Epinette JA, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for H, Knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.PubMedCrossRef
8.
go back to reference Saenz CL, McGrath MS, Marker DR, Seyler TM, Mont MA, Bonutti PM. Early failure of a unicompartmental knee arthroplasty design with an all-polyethylene tibial component. Knee. 2010;17(1):53–6.PubMedCrossRef Saenz CL, McGrath MS, Marker DR, Seyler TM, Mont MA, Bonutti PM. Early failure of a unicompartmental knee arthroplasty design with an all-polyethylene tibial component. Knee. 2010;17(1):53–6.PubMedCrossRef
9.
go back to reference van der List JP, Zuiderbaan HA, Pearle AD. Why do medial unicompartmental knee arthroplasties fail today? J Arthroplast. 2016;31(5):1016–21.CrossRef van der List JP, Zuiderbaan HA, Pearle AD. Why do medial unicompartmental knee arthroplasties fail today? J Arthroplast. 2016;31(5):1016–21.CrossRef
10.
go back to reference Liddle AD, Judge A, Pandit H, Murray DW. Adverse outcomes after total and unicompartmental knee replacement in 101,330 matched patients: a study of data from the National Joint Registry for England and Wales. Lancet. 2014;384(9952):1437–45.PubMedCrossRef Liddle AD, Judge A, Pandit H, Murray DW. Adverse outcomes after total and unicompartmental knee replacement in 101,330 matched patients: a study of data from the National Joint Registry for England and Wales. Lancet. 2014;384(9952):1437–45.PubMedCrossRef
11.
go back to reference Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. Clin Biomech (Bristol, Avon). 2018;51:34–9.CrossRef Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. Clin Biomech (Bristol, Avon). 2018;51:34–9.CrossRef
12.
go back to reference Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J. Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast. 2011;26(3):492–6.CrossRef Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J. Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast. 2011;26(3):492–6.CrossRef
13.
go back to reference Schlegel UJ, Siewe J, Delank KS, Eysel P, Puschel K, Morlock MM, de Uhlenbrock AG. Pulsed lavage improves fixation strength of cemented tibial components. Int Orthop. 2011;35(8):1165–9.PubMedCrossRef Schlegel UJ, Siewe J, Delank KS, Eysel P, Puschel K, Morlock MM, de Uhlenbrock AG. Pulsed lavage improves fixation strength of cemented tibial components. Int Orthop. 2011;35(8):1165–9.PubMedCrossRef
14.
go back to reference Lutz MJ, Pincus PF, Whitehouse SL, Halliday BR. The effect of cement gun and cement syringe use on the tibial cement mantle in total knee arthroplasty. J Arthroplast. 2009;24(3):461–7.CrossRef Lutz MJ, Pincus PF, Whitehouse SL, Halliday BR. The effect of cement gun and cement syringe use on the tibial cement mantle in total knee arthroplasty. J Arthroplast. 2009;24(3):461–7.CrossRef
15.
go back to reference Clarius M, Mohr G, Jaeger S, Seeger JB, Bitsch RG. Femoral fixation pattern in cemented Oxford unicompartmental knee arthroplasty--an experimental cadaver study. Knee. 2010;17(6):398–402.PubMedCrossRef Clarius M, Mohr G, Jaeger S, Seeger JB, Bitsch RG. Femoral fixation pattern in cemented Oxford unicompartmental knee arthroplasty--an experimental cadaver study. Knee. 2010;17(6):398–402.PubMedCrossRef
16.
go back to reference Grupp TM, Pietschmann MF, Holderied M, Scheele C, Schroder C, Jansson V, Muller PE. Primary stability of unicompartmental knee arthroplasty under dynamic compression-shear loading in human tibiae. Clin Biomech (Bristol, Avon). 2013;28(9–10):1006–13.CrossRef Grupp TM, Pietschmann MF, Holderied M, Scheele C, Schroder C, Jansson V, Muller PE. Primary stability of unicompartmental knee arthroplasty under dynamic compression-shear loading in human tibiae. Clin Biomech (Bristol, Avon). 2013;28(9–10):1006–13.CrossRef
17.
go back to reference Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: an experimental cadaver study. Knee. 2017;24(2):402–8.PubMedCrossRef Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: an experimental cadaver study. Knee. 2017;24(2):402–8.PubMedCrossRef
18.
go back to reference Hori RY, Lewis JL. Mechanical properties of the fibrous tissue found at the bone-cement interface following total joint replacement. J Biomed Mater Res. 1982;16(6):911–27.PubMedCrossRef Hori RY, Lewis JL. Mechanical properties of the fibrous tissue found at the bone-cement interface following total joint replacement. J Biomed Mater Res. 1982;16(6):911–27.PubMedCrossRef
19.
go back to reference Miller MA, Terbush MJ, Goodheart JR, Izant TH, Mann KA. Increased initial cement-bone interlock correlates with reduced total knee arthroplasty micro-motion following in vivo service. J Biomech. 2014;47(10):2460–6.PubMedPubMedCentralCrossRef Miller MA, Terbush MJ, Goodheart JR, Izant TH, Mann KA. Increased initial cement-bone interlock correlates with reduced total knee arthroplasty micro-motion following in vivo service. J Biomech. 2014;47(10):2460–6.PubMedPubMedCentralCrossRef
20.
go back to reference Anthony PP, Gie GA, Howie CR, Ling RS. Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg Br. 1990;72(6):971–9.PubMedCrossRef Anthony PP, Gie GA, Howie CR, Ling RS. Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg Br. 1990;72(6):971–9.PubMedCrossRef
21.
go back to reference Star MJ, Colwell CW Jr, Kelman GJ, Ballock RT, Walker RH. Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplast. 1994;9(2):143–9.CrossRef Star MJ, Colwell CW Jr, Kelman GJ, Ballock RT, Walker RH. Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplast. 1994;9(2):143–9.CrossRef
22.
go back to reference Bini SA, Cafri G, Khatod M. Midterm-adjusted survival comparing the best performing unicompartmental and total knee arthroplasties in a registry. J Arthroplast. 2017;32(11):3352–5.CrossRef Bini SA, Cafri G, Khatod M. Midterm-adjusted survival comparing the best performing unicompartmental and total knee arthroplasties in a registry. J Arthroplast. 2017;32(11):3352–5.CrossRef
23.
go back to reference Kleeblad LJ, van der List JP, Zuiderbaan HA, Pearle AD. Regional femoral and tibial radiolucency in cemented unicompartmental knee arthroplasty and the relationship to functional outcomes. J Arthroplast. 2017;32(11):3345–51.CrossRef Kleeblad LJ, van der List JP, Zuiderbaan HA, Pearle AD. Regional femoral and tibial radiolucency in cemented unicompartmental knee arthroplasty and the relationship to functional outcomes. J Arthroplast. 2017;32(11):3345–51.CrossRef
24.
go back to reference Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;(163);163:290–9. Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;(163);163:290–9.
25.
go back to reference Markolf KL, Amstutz HC. Penetration and flow of acrylic bone cement. Clin Orthop Relat Res. 1976;121:99–102. Markolf KL, Amstutz HC. Penetration and flow of acrylic bone cement. Clin Orthop Relat Res. 1976;121:99–102.
26.
go back to reference Walker PS, Soudry M, Ewald FC, McVickar H. Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res. 1984;185:155–64. Walker PS, Soudry M, Ewald FC, McVickar H. Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res. 1984;185:155–64.
27.
go back to reference Panjabi MM, Cimino WR, Drinker H. Effect of pressure on bone cement stiffness. An in vitro study. Acta Orthop Scand. 1986;57(2):106–10.PubMedCrossRef Panjabi MM, Cimino WR, Drinker H. Effect of pressure on bone cement stiffness. An in vitro study. Acta Orthop Scand. 1986;57(2):106–10.PubMedCrossRef
28.
go back to reference Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res. 1984;1(4):412–20.PubMedCrossRef Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res. 1984;1(4):412–20.PubMedCrossRef
29.
go back to reference MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–8. MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–8.
30.
go back to reference Mann KA, Ayers DC, Werner FW, Nicoletta RJ, Fortino MD. Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J Biomech. 1997;30(4):339–46.PubMedCrossRef Mann KA, Ayers DC, Werner FW, Nicoletta RJ, Fortino MD. Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J Biomech. 1997;30(4):339–46.PubMedCrossRef
31.
go back to reference Nagel K, Bishop NE, Schlegel UJ, Puschel K, Morlock MM. The influence of cement morphology parameters on the strength of the cement-bone Interface in tibial tray fixation. J Arthroplast. 2017;32(2):563–569 e561.CrossRef Nagel K, Bishop NE, Schlegel UJ, Puschel K, Morlock MM. The influence of cement morphology parameters on the strength of the cement-bone Interface in tibial tray fixation. J Arthroplast. 2017;32(2):563–569 e561.CrossRef
32.
go back to reference Maistrelli GL, Antonelli L, Fornasier V, Mahomed N. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop Relat Res. 1995;312:261–5. Maistrelli GL, Antonelli L, Fornasier V, Mahomed N. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop Relat Res. 1995;312:261–5.
33.
go back to reference Miskovsky C, Whiteside LA, White SE. The cemented unicondylar knee arthroplasty. An in vitro comparison of three cement techniques. Clin Orthop Relat Res. 1992;284:215–20. Miskovsky C, Whiteside LA, White SE. The cemented unicondylar knee arthroplasty. An in vitro comparison of three cement techniques. Clin Orthop Relat Res. 1992;284:215–20.
34.
go back to reference Seeger JB, Jaeger S, Bitsch RG, Mohr G, Rohner E, Clarius M. The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement. J Bone Joint Surg Am. 2013;95(1):48–53.PubMedCrossRef Seeger JB, Jaeger S, Bitsch RG, Mohr G, Rohner E, Clarius M. The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement. J Bone Joint Surg Am. 2013;95(1):48–53.PubMedCrossRef
35.
go back to reference Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75(3):459–63.PubMedCrossRef Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75(3):459–63.PubMedCrossRef
36.
go back to reference Stannage K, Shakespeare D, Bulsara M. Suction technique to improve cement penetration under the tibial component in total knee arthroplasty. Knee. 2003;10(1):67–73.PubMedCrossRef Stannage K, Shakespeare D, Bulsara M. Suction technique to improve cement penetration under the tibial component in total knee arthroplasty. Knee. 2003;10(1):67–73.PubMedCrossRef
37.
go back to reference Ritter MA, Herbst SA, Keating EM, Faris PM. Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am. 1994;76(1):60–5.PubMedCrossRef Ritter MA, Herbst SA, Keating EM, Faris PM. Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am. 1994;76(1):60–5.PubMedCrossRef
38.
go back to reference Noble PC, Swarts E. Penetration of acrylic bone cements into cancellous bone. Acta Orthop Scand. 1983;54(4):566–73.PubMedCrossRef Noble PC, Swarts E. Penetration of acrylic bone cements into cancellous bone. Acta Orthop Scand. 1983;54(4):566–73.PubMedCrossRef
39.
go back to reference Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.PubMedCrossRef Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.PubMedCrossRef
40.
go back to reference Silverman EJ, Landy DC, Massel DH, Kaimrajh DN, Latta LL, Robinson RP. The effect of viscosity on cement penetration in total knee arthroplasty, an application of the squeeze film effect. J Arthroplast. 2014;29(10):2039–42.CrossRef Silverman EJ, Landy DC, Massel DH, Kaimrajh DN, Latta LL, Robinson RP. The effect of viscosity on cement penetration in total knee arthroplasty, an application of the squeeze film effect. J Arthroplast. 2014;29(10):2039–42.CrossRef
41.
go back to reference Panjabi MM, Goel VK, Drinker H, Wong J, Kamire G, Walter SD. Effect of pressurization on methylmethacrylate-bone interdigitation: an in vitro study of canine femora. J Biomech. 1983;16(7):473–80.PubMedCrossRef Panjabi MM, Goel VK, Drinker H, Wong J, Kamire G, Walter SD. Effect of pressurization on methylmethacrylate-bone interdigitation: an in vitro study of canine femora. J Biomech. 1983;16(7):473–80.PubMedCrossRef
42.
go back to reference Banwart JC, McQueen DA, Friis EA, Graber CD. Negative pressure intrusion cementing technique for total knee arthroplasty. J Arthroplast. 2000;15(3):360–7.CrossRef Banwart JC, McQueen DA, Friis EA, Graber CD. Negative pressure intrusion cementing technique for total knee arthroplasty. J Arthroplast. 2000;15(3):360–7.CrossRef
43.
go back to reference Scheele CB, Muller PE, Schroder C, Grupp T, Jansson V, Pietschmann MF. Accuracy of a non-invasive CT-based measuring technique for cement penetration depth in human tibial UKA. BMC Med Imaging. 2019;19(1):9.PubMedPubMedCentralCrossRef Scheele CB, Muller PE, Schroder C, Grupp T, Jansson V, Pietschmann MF. Accuracy of a non-invasive CT-based measuring technique for cement penetration depth in human tibial UKA. BMC Med Imaging. 2019;19(1):9.PubMedPubMedCentralCrossRef
44.
go back to reference Pietschmann MF, Frohlich V, Ficklscherer A, Gulecyuz MF, Wegener B, Jansson V, Muller PE. Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair. Arch Orthop Trauma Surg. 2009;129(3):373–9.PubMedCrossRef Pietschmann MF, Frohlich V, Ficklscherer A, Gulecyuz MF, Wegener B, Jansson V, Muller PE. Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair. Arch Orthop Trauma Surg. 2009;129(3):373–9.PubMedCrossRef
45.
go back to reference Pietschmann MF, Gulecyuz MF, Fieseler S, Hentschel M, Rossbach B, Jansson V, Muller PE. Biomechanical stability of knotless suture anchors used in rotator cuff repair in healthy and osteopenic bone. Arthroscopy. 2010;26(8):1035–44.PubMedCrossRef Pietschmann MF, Gulecyuz MF, Fieseler S, Hentschel M, Rossbach B, Jansson V, Muller PE. Biomechanical stability of knotless suture anchors used in rotator cuff repair in healthy and osteopenic bone. Arthroscopy. 2010;26(8):1035–44.PubMedCrossRef
46.
go back to reference Dorr LD, Lindberg JP, Claude-Faugere M, Malluche HH. Factors influencing the intrusion of methylmethacrylate into human tibiae. Clin Orthop Relat Res. 1984;183:147–52. Dorr LD, Lindberg JP, Claude-Faugere M, Malluche HH. Factors influencing the intrusion of methylmethacrylate into human tibiae. Clin Orthop Relat Res. 1984;183:147–52.
Metadata
Title
Influence of bone density on morphologic cement penetration in minimally invasive tibial unicompartmental knee arthroplasty: an in vitro cadaver study
Authors
Christian B. Scheele
Matthias F. Pietschmann
Christian Schröder
Igor Lazic
Thomas M. Grupp
Peter E. Müller
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2019
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-019-1376-6

Other articles of this Issue 1/2019

Journal of Orthopaedic Surgery and Research 1/2019 Go to the issue