Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2018

Open Access 01-12-2018 | Research article

Clinical outcomes and repair integrity of arthroscopic rotator cuff repair using suture-bridge technique with or without medial tying: prospective comparative study

Authors: Kyung Cheon Kim, Hyun Dae Shin, Woo-Yong Lee, Kyu-Woong Yeon, Sun-Cheol Han

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2018

Login to get access

Abstract

Background

There have been few studies comparing clinical and radiological outcomes between the conventional and knotless suture-bridge techniques. The purpose of this study was to evaluate and compare the functional outcomes and repair integrity of arthroscopic conventional and knotless suture-bridge technique for full-thickness rotator cuff tears.

Methods

We prospectively followed 100 consecutive patients (100 shoulders) with full-thickness rotator cuff tears treated with the arthroscopic conventional or knotless suture-bridge technique from October 2012 to July 2014. Enrolled patients returned for follow-up functional evaluations at 1 and 2 years after the operation. There were four outcome measures in this study: American Shoulder and Elbow Surgeons (ASES) scores, Shoulder Rating Scale of the University of California at Los Angeles (UCLA) scores, Constant scores, and visual analog scale (VAS) pain scores. Enrolled patients returned for follow-up magnetic resonance imaging or ultrasonography evaluation to confirm the integrity of the repaired cuff at 6 months post-operation (97% follow-up rate). Also, we investigated the preoperative cuff retraction of enrolled patients using preoperative MRI to find out correlation between the stage of cuff retraction and re-tear rate.

Results

At final follow-up, the average UCLA, ASES, Constant, and VAS scores had improved significantly to 32.5, 88.0, 80.4, and 1.3, respectively, in the conventional suture-bridge technique group and to 33.0, 89.7, 81.2, and 1.2, respectively, in the knotless suture-bridge technique group. The UCLA, ASES, Constant, and VAS scores improved in both groups after surgery (all p < 0.001), and there were no significant differences between the two groups at 2-year follow-up (p = 0.292, 0.359, 0.709, and 0.636, respectively). The re-tear rate of repaired rotator cuffs was 16.3% (8/49 shoulders) in the conventional suture-bridge technique group and 29.2% (14/48 shoulders) in the knotless suture-bridge technique group; this difference was not significant (p = 0.131). There were no significant differences between the re-tear rate of the two groups in the Patte stage I and II (p = 0.358 and 0.616).

Conclusions

The knotless suture-bridge technique showed comparable functional outcomes to those of conventional suture-bridge techniques in medium-to-large, full-thickness rotator cuff tears at short-term follow-up. The knotless suture-bridge technique had a higher re-tear rate compared with conventional suture-bridge technique, although the difference was not significant.
Literature
1.
go back to reference Minagawa H, Yamamoto N, Abe H, Fukuda M, Seki N, Kikuchi K, et al. Prevalence of symptomatic and asymptomatic rotator cuff tears in the general population: from mass-screening in one village. J Orthop. 2013;10(1):8–12.CrossRefPubMedPubMedCentral Minagawa H, Yamamoto N, Abe H, Fukuda M, Seki N, Kikuchi K, et al. Prevalence of symptomatic and asymptomatic rotator cuff tears in the general population: from mass-screening in one village. J Orthop. 2013;10(1):8–12.CrossRefPubMedPubMedCentral
2.
go back to reference Elia F, Azoulay V, Lebon J, Faraud A, Bonnevialle N, Mansat P. Clinical and anatomic results of surgical repair of chronic rotator cuff tears at ten-year minimum follow-up. Int Orthop. 2017;41(6):1219–26.CrossRefPubMed Elia F, Azoulay V, Lebon J, Faraud A, Bonnevialle N, Mansat P. Clinical and anatomic results of surgical repair of chronic rotator cuff tears at ten-year minimum follow-up. Int Orthop. 2017;41(6):1219–26.CrossRefPubMed
3.
go back to reference Heuberer PR, Smolen D, Pauzenberger L, Plachel F, Salem S, Laky B, et al. Longitudinal long-term magnetic resonance imaging and clinical follow-up after single-row arthroscopic rotator cuff repair: clinical superiority of structural tendon integrity. Am J Sports Med. 2017;45(6):1283–8.CrossRefPubMed Heuberer PR, Smolen D, Pauzenberger L, Plachel F, Salem S, Laky B, et al. Longitudinal long-term magnetic resonance imaging and clinical follow-up after single-row arthroscopic rotator cuff repair: clinical superiority of structural tendon integrity. Am J Sports Med. 2017;45(6):1283–8.CrossRefPubMed
4.
go back to reference Barnes LA, Kim HM, Caldwell JM, Buza J, Ahmad CS, Bigliani LU. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair. Bone Joint J. 2017;99-B(2):245–9.CrossRefPubMed Barnes LA, Kim HM, Caldwell JM, Buza J, Ahmad CS, Bigliani LU. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair. Bone Joint J. 2017;99-B(2):245–9.CrossRefPubMed
5.
go back to reference Park MC, ElAttrache NS, Ahmad CS, Tibone JE. “Transosseous-equivalent” rotator cuff repair technique. Arthroscopy. 2006;22(12):1360.e1–5.CrossRef Park MC, ElAttrache NS, Ahmad CS, Tibone JE. “Transosseous-equivalent” rotator cuff repair technique. Arthroscopy. 2006;22(12):1360.e1–5.CrossRef
6.
go back to reference Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ. Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double row repair technique. J Shoulder Elb Surg. 2007;16(4):461–8.CrossRef Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ. Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double row repair technique. J Shoulder Elb Surg. 2007;16(4):461–8.CrossRef
7.
go back to reference Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun BJ, Lee TQ. Part II: biomechanical assessment for a footprintrestoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elb Surg. 2007;16(4):469–76.CrossRef Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun BJ, Lee TQ. Part II: biomechanical assessment for a footprintrestoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elb Surg. 2007;16(4):469–76.CrossRef
8.
go back to reference Quigley RJ, Gupta A, Oh JH, Chung KC, McGarry MH, Gupta R, et al. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model. J Orthop Res. 2013;31(8):1254–60.CrossRefPubMed Quigley RJ, Gupta A, Oh JH, Chung KC, McGarry MH, Gupta R, et al. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model. J Orthop Res. 2013;31(8):1254–60.CrossRefPubMed
9.
go back to reference Trantalis JN, Boorman RS, Pletsch K, Lo IK. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2008;24(6):727–31.CrossRefPubMed Trantalis JN, Boorman RS, Pletsch K, Lo IK. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2008;24(6):727–31.CrossRefPubMed
10.
go back to reference Yamakado K, Katsuo S, Mizuno K, Arakawa H, Hayashi S. Medial-row failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2010;26(3):430–5.CrossRefPubMed Yamakado K, Katsuo S, Mizuno K, Arakawa H, Hayashi S. Medial-row failure after arthroscopic double-row rotator cuff repair. Arthroscopy. 2010;26(3):430–5.CrossRefPubMed
11.
go back to reference Wang VM, Wang FC, McNickle AG, Friel NA, Yanke AB, Chubinskaya S, et al. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair. Am J Sports Med. 2010;38(12):2456–63.CrossRefPubMedPubMedCentral Wang VM, Wang FC, McNickle AG, Friel NA, Yanke AB, Chubinskaya S, et al. Medial versus lateral supraspinatus tendon properties: implications for double-row rotator cuff repair. Am J Sports Med. 2010;38(12):2456–63.CrossRefPubMedPubMedCentral
12.
go back to reference Cho NS, Lee BG, Rhee YG. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Am J Sports Med. 2011;39(10):2108–16.CrossRefPubMed Cho NS, Lee BG, Rhee YG. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Am J Sports Med. 2011;39(10):2108–16.CrossRefPubMed
13.
go back to reference Kim YK, Moon SH, Cho SH. Treatment outcomes of single- versus double-row repair for larger than medium-sized rotator cuff tears: the effect of preoperative remnant tendon length. Am J Sports Med. 2013;41(10):2270–7.CrossRefPubMed Kim YK, Moon SH, Cho SH. Treatment outcomes of single- versus double-row repair for larger than medium-sized rotator cuff tears: the effect of preoperative remnant tendon length. Am J Sports Med. 2013;41(10):2270–7.CrossRefPubMed
14.
go back to reference Rhee YG, Cho NS, Parke CS. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique. Am J Sports Med. 2012;40(11):2440–7.CrossRefPubMed Rhee YG, Cho NS, Parke CS. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique. Am J Sports Med. 2012;40(11):2440–7.CrossRefPubMed
15.
go back to reference Vaishnav S, Millett PJ. Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Shoulder Elb Surg. 2010;19(2):83–90.CrossRef Vaishnav S, Millett PJ. Arthroscopic rotator cuff repair: scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Shoulder Elb Surg. 2010;19(2):83–90.CrossRef
16.
go back to reference Barber FA, Drew OR. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors. Arthroscopy. 2012;28(9):1197–205.CrossRefPubMed Barber FA, Drew OR. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors. Arthroscopy. 2012;28(9):1197–205.CrossRefPubMed
17.
go back to reference Burkhart SS, Adams CR, Burkhart SS, Schoolfield JD. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy. 2009;25(3):274–81.CrossRefPubMed Burkhart SS, Adams CR, Burkhart SS, Schoolfield JD. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy. 2009;25(3):274–81.CrossRefPubMed
18.
go back to reference Millett PJ, Espinoza C, Horan MP, Ho CP, Warth RJ, Dornan GJ, et al. Predictors of outcomes after arthroscopic transosseous equivalent rotator cuff repair in 155 cases: a propensity score weighted analysis of knotted and knotless self-reinforcing repair techniques at a minimum of 2 years. Arch Orthop Trauma Surg. 2017;137(10):1399–408.CrossRefPubMed Millett PJ, Espinoza C, Horan MP, Ho CP, Warth RJ, Dornan GJ, et al. Predictors of outcomes after arthroscopic transosseous equivalent rotator cuff repair in 155 cases: a propensity score weighted analysis of knotted and knotless self-reinforcing repair techniques at a minimum of 2 years. Arch Orthop Trauma Surg. 2017;137(10):1399–408.CrossRefPubMed
19.
go back to reference Boyer P, Bouthors C, Delcourt T, Stewart O, Hamida F, Mylle G, et al. Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques. Knee Surg Sports Traumatol Arthrosc. 2015;23(2):478–86.CrossRefPubMed Boyer P, Bouthors C, Delcourt T, Stewart O, Hamida F, Mylle G, et al. Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques. Knee Surg Sports Traumatol Arthrosc. 2015;23(2):478–86.CrossRefPubMed
20.
go back to reference Hug K, Gerhardt C, Hanevald H, Scheibel M. Arthroscopic knotless-anchor rotator cuff repair: a clinical and radiological evaluation. Knee Surg Sports Traumatol Arthrosc. 2015;23(9):2628–34.CrossRefPubMed Hug K, Gerhardt C, Hanevald H, Scheibel M. Arthroscopic knotless-anchor rotator cuff repair: a clinical and radiological evaluation. Knee Surg Sports Traumatol Arthrosc. 2015;23(9):2628–34.CrossRefPubMed
21.
go back to reference Sugaya H, Maeda K, Matsuki K, Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005;21(11):1307–16.CrossRefPubMed Sugaya H, Maeda K, Matsuki K, Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005;21(11):1307–16.CrossRefPubMed
22.
go back to reference Patte D. Classification of rotator cuff lesions. Clin Orthop Relat Res. 1990;254:81–6. Patte D. Classification of rotator cuff lesions. Clin Orthop Relat Res. 1990;254:81–6.
23.
go back to reference Kim KC, Rhee KJ, Shin HD, Kim YM. A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair. Arthroscopy. 2007;23(5):562.e1–4.CrossRef Kim KC, Rhee KJ, Shin HD, Kim YM. A modified suture-bridge technique for a marginal dog-ear deformity caused during rotator cuff repair. Arthroscopy. 2007;23(5):562.e1–4.CrossRef
24.
go back to reference Virk MS, Bruce B, Hussey KE, Thomas JM, Luthringer TA, Shewman EF, et al. Biomechanical performance of medial row suture placement relative to the musculotendinous junction in transosseous equivalent suture bridge double-row rotator cuff repair. Arthroscopy. 2017;33(2):242–50.CrossRefPubMed Virk MS, Bruce B, Hussey KE, Thomas JM, Luthringer TA, Shewman EF, et al. Biomechanical performance of medial row suture placement relative to the musculotendinous junction in transosseous equivalent suture bridge double-row rotator cuff repair. Arthroscopy. 2017;33(2):242–50.CrossRefPubMed
25.
go back to reference Kim KC, Shin HD, Cha SM, Park JY. Comparisons of retear patterns for 3 arthroscopic rotator cuff repair methods. Am J Sports Med. 2014;42(3):558–65.CrossRefPubMed Kim KC, Shin HD, Cha SM, Park JY. Comparisons of retear patterns for 3 arthroscopic rotator cuff repair methods. Am J Sports Med. 2014;42(3):558–65.CrossRefPubMed
26.
go back to reference Ide J, Karasugi T, Okamoto N, Taniwaki T, Oka K, Mizuta H. Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears. J Shoulder Elb Surg. 2015;24(10):1544–54.CrossRef Ide J, Karasugi T, Okamoto N, Taniwaki T, Oka K, Mizuta H. Functional and structural comparisons of the arthroscopic knotless double-row suture bridge and single-row repair for anterosuperior rotator cuff tears. J Shoulder Elb Surg. 2015;24(10):1544–54.CrossRef
27.
go back to reference Kummer F, Hergan DJ, Thut DC, Pahk B, Jazrawi LM. Suture loosening and its effect on tendon fixation in knotless double-row rotator cuff repairs. Arthroscopy. 2011;27(11):1478–84.CrossRefPubMed Kummer F, Hergan DJ, Thut DC, Pahk B, Jazrawi LM. Suture loosening and its effect on tendon fixation in knotless double-row rotator cuff repairs. Arthroscopy. 2011;27(11):1478–84.CrossRefPubMed
28.
go back to reference Leek BT, Robertson C, Mahar A, Pedowitz RA. Comparison of mechanical stability in double-row rotator cuff repairs between a knotless transtendon construct versus the addition of medial knots. Arthroscopy. 2010;26(Suppl 9):S127–33.CrossRefPubMed Leek BT, Robertson C, Mahar A, Pedowitz RA. Comparison of mechanical stability in double-row rotator cuff repairs between a knotless transtendon construct versus the addition of medial knots. Arthroscopy. 2010;26(Suppl 9):S127–33.CrossRefPubMed
29.
go back to reference Kuhn JE, Dunn WR, Ma B, Wright RW, Jones G, Spencer EE, et al. Interobserver agreement in the classification of rotator cuff tears. Am J Sports Med. 2007;35(3):437–41.CrossRefPubMed Kuhn JE, Dunn WR, Ma B, Wright RW, Jones G, Spencer EE, et al. Interobserver agreement in the classification of rotator cuff tears. Am J Sports Med. 2007;35(3):437–41.CrossRefPubMed
30.
go back to reference Spencer EE Jr, Dunn WR, Wright RW, Wolf BR, Spindler KP, McCarty E, et al. Interobserver agreement in the classification of rotator cuff tears using magnetic resonance imaging. Am J Sports Med. 2008;36(1):99–103.CrossRefPubMed Spencer EE Jr, Dunn WR, Wright RW, Wolf BR, Spindler KP, McCarty E, et al. Interobserver agreement in the classification of rotator cuff tears using magnetic resonance imaging. Am J Sports Med. 2008;36(1):99–103.CrossRefPubMed
31.
go back to reference Gladstone JN, Bishop JY, Lo IK, Flatow EL. Fatty infiltration and atrophy of the rotator cuff do not improve after rotator cuff repair and correlate with poor functional outcome. Am J Sports Med. 2007;35(5):719–28.CrossRefPubMed Gladstone JN, Bishop JY, Lo IK, Flatow EL. Fatty infiltration and atrophy of the rotator cuff do not improve after rotator cuff repair and correlate with poor functional outcome. Am J Sports Med. 2007;35(5):719–28.CrossRefPubMed
32.
go back to reference Park JY, Siti HT, Keum JS, Moon SG, Oh KS. Does an arthroscopic suture bridge technique maintain repair integrity? A serial evaluation by ultrasonography. Clin Orthop Relat Res. 2010;468(6):1578–87.CrossRefPubMed Park JY, Siti HT, Keum JS, Moon SG, Oh KS. Does an arthroscopic suture bridge technique maintain repair integrity? A serial evaluation by ultrasonography. Clin Orthop Relat Res. 2010;468(6):1578–87.CrossRefPubMed
33.
go back to reference Lafosse L, Brozska R, Toussaint B, Gobezie R. The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am. 2007;89(7):1533–41.PubMed Lafosse L, Brozska R, Toussaint B, Gobezie R. The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am. 2007;89(7):1533–41.PubMed
Metadata
Title
Clinical outcomes and repair integrity of arthroscopic rotator cuff repair using suture-bridge technique with or without medial tying: prospective comparative study
Authors
Kyung Cheon Kim
Hyun Dae Shin
Woo-Yong Lee
Kyu-Woong Yeon
Sun-Cheol Han
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2018
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-018-0921-z

Other articles of this Issue 1/2018

Journal of Orthopaedic Surgery and Research 1/2018 Go to the issue