Open Access 01-12-2018 | Research article

New fixation approach for transverse metacarpal neck fracture: a biomechanical study

Authors: Yung-Cheng Chiu, Ming-Tzu Tsai, Cheng-En Hsu, Horng-Chaung Hsu, Heng-Li Huang, Jui-Ting Hsu

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2018

Login to get access

Abstract

Background

Fifth metacarpal neck fracture, also known as boxer’s fracture, is the most common metacarpal fracture. Percutaneous Kirschner-wire (K-wire) pinning has been shown to produce favorable clinical results. However, the fixation power of K-wires is a major concern. Plate fixation is also a surgical option, but it has the disadvantages of tendon adhesion, requirement of secondary surgery for removal of the implant, and postoperative joint stiffness. A fixation method that causes little soft tissue damage and provides high biomechanical stability is required for patients with fifth metacarpal neck fracture for whom surgical intervention is indicated. The present study proposed fixation using K-wires and a cerclage wire to treat fifth metacarpal neck fracture. The fixation power of this new method was compared with that of K-wires alone and plates.

Methods

We used a saw blade to create transverse metacarpal neck fractures in 16 artificial metacarpal bone specimens, which were then treated with four types of fixation as follows: (1) locking plate with five locking bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two K-wires (K group), and (4) two K-wires and a figure-of-eight cerclage wire (KW group). The specimens were tested by using cantilever bending testing on a material testing system. The stiffness of the four fixation types was determined by observing force–displacement curves. Finally, the Kruskal–Wallis test was adopted to process the data, and the Mann–Whitney exact test was performed to conduct paired comparison between the fixation types.

Results

The fixation strength levels of the four fixation approaches for treating fifth metacarpal neck fracture were ranked in a descending order of LP group (24.6 ± 5.1 N/mm, median ± interquartile range) > RP group (22.2 ± 5.8 N/mm) ≅ KW group (20.1 ± 3.2 N/mm) > K group (16.9 ± 3.0 N/mm).

Conclusion

The fixation strength of two K-wires was significantly higher when reinforcement was provided using a figure-of-eight cerclage wire. The strength of the proposed approach is similar to that of a regular plate with five bicortical screws but weaker than that of a locking plate with the same amount of bicortical screws. Cerclage wire-integrated K-wires can be an alternative method that avoids the excessive soft tissue dissection required for plating in open reduction internal fixation for fifth metacarpal neck fracture.
Literature
1.
go back to reference Padegimas EM, Warrender WJ, Jones CM, Ilyas AM. Metacarpal neck fractures: a review of surgical indications and techniques. Arch Trauma Res. 2016;5(3):e32933.CrossRefPubMedPubMedCentral Padegimas EM, Warrender WJ, Jones CM, Ilyas AM. Metacarpal neck fractures: a review of surgical indications and techniques. Arch Trauma Res. 2016;5(3):e32933.CrossRefPubMedPubMedCentral
2.
go back to reference Boussakri H, Elidrissi M, Azarkane M, Bensaad S, Bachiri M, Shimi M, Elibrahimi A, Elmrini A. Fractures of the neck of the fifth metacarpal bone, treated by percutaneous intramedullary nailing: surgical technique, radiological and clinical results study (28 cases). Pan Afr Med J. 2014;18:187.PubMedPubMedCentral Boussakri H, Elidrissi M, Azarkane M, Bensaad S, Bachiri M, Shimi M, Elibrahimi A, Elmrini A. Fractures of the neck of the fifth metacarpal bone, treated by percutaneous intramedullary nailing: surgical technique, radiological and clinical results study (28 cases). Pan Afr Med J. 2014;18:187.PubMedPubMedCentral
3.
go back to reference Facca S, Ramdhian R, Pelissier A, Diaconu M, Liverneaux P. Fifth metacarpal neck fracture fixation: locking plate versus K-wire? Orthop Traumatol Surg Res. 2010;96(5):506–12.CrossRefPubMed Facca S, Ramdhian R, Pelissier A, Diaconu M, Liverneaux P. Fifth metacarpal neck fracture fixation: locking plate versus K-wire? Orthop Traumatol Surg Res. 2010;96(5):506–12.CrossRefPubMed
4.
go back to reference Potenza V, Caterini R, De Maio F, Bisicchia S, Farsetti P. Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning. Injury. 2012;43(2):242–5.CrossRefPubMed Potenza V, Caterini R, De Maio F, Bisicchia S, Farsetti P. Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning. Injury. 2012;43(2):242–5.CrossRefPubMed
5.
go back to reference Harris AR, Beckenbaugh RD, Nettrour JF, Rizzo M. Metacarpal neck fractures: results of treatment with traction reduction and cast immobilization. Hand (N Y). 2009;4(2):161–4.CrossRef Harris AR, Beckenbaugh RD, Nettrour JF, Rizzo M. Metacarpal neck fractures: results of treatment with traction reduction and cast immobilization. Hand (N Y). 2009;4(2):161–4.CrossRef
6.
go back to reference Wong KP, Hay RA, Tay SC. Surgical outcomes of fifth metacarpal neck fractures—a comparative analysis of dorsal plating versus tension band wiring. Hand Surg. 2015;20(1):99–105.CrossRefPubMed Wong KP, Hay RA, Tay SC. Surgical outcomes of fifth metacarpal neck fractures—a comparative analysis of dorsal plating versus tension band wiring. Hand Surg. 2015;20(1):99–105.CrossRefPubMed
7.
go back to reference Kollitz KM, Hammert WC, Vedder NB, Huang JI. Metacarpal fractures: treatment and complications. Hand (N Y). 2014;9(1):16–23.CrossRef Kollitz KM, Hammert WC, Vedder NB, Huang JI. Metacarpal fractures: treatment and complications. Hand (N Y). 2014;9(1):16–23.CrossRef
8.
go back to reference Wong TC, Ip FK, Yeung SH. Comparison between percutaneous transverse fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger. J Hand Surg. 2006;31(1):61–5.CrossRef Wong TC, Ip FK, Yeung SH. Comparison between percutaneous transverse fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger. J Hand Surg. 2006;31(1):61–5.CrossRef
9.
go back to reference Schädel-Höpfner M, Wild M, Windolf J, Linhart W. Antegrade intramedullary splinting or percutaneous retrograde crossed pinning for displaced neck fractures of the fifth metacarpal? Arch Orthop Trauma Surg. 2007;127(6):435–40.CrossRefPubMed Schädel-Höpfner M, Wild M, Windolf J, Linhart W. Antegrade intramedullary splinting or percutaneous retrograde crossed pinning for displaced neck fractures of the fifth metacarpal? Arch Orthop Trauma Surg. 2007;127(6):435–40.CrossRefPubMed
10.
go back to reference Winter M, Balaguer T, Bessiere C, Carles M, Lebreton E. Surgical treatment of the boxer’s fracture: transverse pinning versus intramedullary pinning. J Hand Surg Eur Vol. 2007;32(6):709–13.CrossRefPubMed Winter M, Balaguer T, Bessiere C, Carles M, Lebreton E. Surgical treatment of the boxer’s fracture: transverse pinning versus intramedullary pinning. J Hand Surg Eur Vol. 2007;32(6):709–13.CrossRefPubMed
11.
go back to reference Leinberry C, Ukomadu U, Ilyas A, Metacarpal fractures and carpometacarpal fracture-dislocations. 1st ed New Delhi: Jaypee Brothers Medical Publishers Ltd;. 2013; Leinberry C, Ukomadu U, Ilyas A, Metacarpal fractures and carpometacarpal fracture-dislocations. 1st ed New Delhi: Jaypee Brothers Medical Publishers Ltd;. 2013;
12.
go back to reference Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary? Hand (N Y). 2013;8(4):454–9.CrossRefPubMedCentral Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary? Hand (N Y). 2013;8(4):454–9.CrossRefPubMedCentral
13.
go back to reference Malasitt P, Owen JR, Tremblay M-A, Wayne JS, Isaacs JE. Fixation for metacarpal neck fracture: a biomechanical study. Hand. 2015;10(3):438–43.CrossRefPubMed Malasitt P, Owen JR, Tremblay M-A, Wayne JS, Isaacs JE. Fixation for metacarpal neck fracture: a biomechanical study. Hand. 2015;10(3):438–43.CrossRefPubMed
14.
go back to reference Ochman S, Vordemvenne T, Paletta J, Raschke MJ, Meffert RH, Doht S. Experimental fracture model versus osteotomy model in metacarpal bone plate fixation. TheScientificWorldJOURNAL. 2011;11:1692–8.CrossRefPubMedPubMedCentral Ochman S, Vordemvenne T, Paletta J, Raschke MJ, Meffert RH, Doht S. Experimental fracture model versus osteotomy model in metacarpal bone plate fixation. TheScientificWorldJOURNAL. 2011;11:1692–8.CrossRefPubMedPubMedCentral
15.
go back to reference Nicklin S, Ingram S, Gianoutsos MP, Walsh WR. In vitro comparison of lagged and nonlagged screw fixation of metacarpal fractures in cadavers. J Hand Surg. 2008;33(10):1732–6.CrossRef Nicklin S, Ingram S, Gianoutsos MP, Walsh WR. In vitro comparison of lagged and nonlagged screw fixation of metacarpal fractures in cadavers. J Hand Surg. 2008;33(10):1732–6.CrossRef
16.
go back to reference Bozic KJ, Perez LE, Wilson DR, Fitzgibbons PG, Jupiter JB. Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg. 2001;26(4):755–61.CrossRef Bozic KJ, Perez LE, Wilson DR, Fitzgibbons PG, Jupiter JB. Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg. 2001;26(4):755–61.CrossRef
17.
go back to reference Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-wires and plate-screw constructs. Orthop Surg. 2015;7(3):256–60.CrossRefPubMed Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-wires and plate-screw constructs. Orthop Surg. 2015;7(3):256–60.CrossRefPubMed
18.
go back to reference Liodaki E, Wendlandt R, Waizner K, Schopp BE, Mailander P, Stang F. A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test. Medicine. 2017;96(27):e6926.CrossRefPubMedPubMedCentral Liodaki E, Wendlandt R, Waizner K, Schopp BE, Mailander P, Stang F. A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test. Medicine. 2017;96(27):e6926.CrossRefPubMedPubMedCentral
19.
go back to reference Elfar J, Stanbury S, Menorca RMG, Reed JD. Composite bone models in orthopaedic surgery research and education. J Am Acad Orthop Surg. 2014;22(2):111.PubMedPubMedCentral Elfar J, Stanbury S, Menorca RMG, Reed JD. Composite bone models in orthopaedic surgery research and education. J Am Acad Orthop Surg. 2014;22(2):111.PubMedPubMedCentral
20.
go back to reference American Society for Testing and Materials A. ASTM F1839 - 08 Standard specification for rigid polyurethane foam for use as a standard material for testing orthopedic devices and instruments. American Society for Testing and Materials A. ASTM F1839 - 08 Standard specification for rigid polyurethane foam for use as a standard material for testing orthopedic devices and instruments.
21.
go back to reference Doht S, Meffert RH, Raschke MJ, Blunk T, Ochman S. Biomechanical analysis of the efficacy of locking plates during cyclic loading in metacarpal fractures. TheScientificWorldJOURNAL. 2014;2014:648787.CrossRefPubMedPubMedCentral Doht S, Meffert RH, Raschke MJ, Blunk T, Ochman S. Biomechanical analysis of the efficacy of locking plates during cyclic loading in metacarpal fractures. TheScientificWorldJOURNAL. 2014;2014:648787.CrossRefPubMedPubMedCentral
22.
go back to reference Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg. 2010;35(4):597–603.CrossRef Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg. 2010;35(4):597–603.CrossRef
23.
go back to reference Eu-Jin Cheah A, Behn AW, Comer G, Yao J. A biomechanical analysis of 2 constructs for metacarpal spiral fracture fixation in a cadaver model: 2 large screws versus 3 small screws. J Hand Surg. 2017;42(12):1033 e1–6.CrossRef Eu-Jin Cheah A, Behn AW, Comer G, Yao J. A biomechanical analysis of 2 constructs for metacarpal spiral fracture fixation in a cadaver model: 2 large screws versus 3 small screws. J Hand Surg. 2017;42(12):1033 e1–6.CrossRef
24.
go back to reference Black D, Mann R, Constine R, Daniels A. Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg. 1985;10(4):466–72.CrossRef Black D, Mann R, Constine R, Daniels A. Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg. 1985;10(4):466–72.CrossRef
25.
go back to reference Firoozbakhsh KK, Moneim MS, Doherty W, Naraghi FF. Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading. Clinical Orthopaedics and Related Research. 1996;325:296–301.CrossRef Firoozbakhsh KK, Moneim MS, Doherty W, Naraghi FF. Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading. Clinical Orthopaedics and Related Research. 1996;325:296–301.CrossRef
26.
go back to reference Mann R, Black D, Constine R, Daniels A. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg. 1985;10(6):1024–8.CrossRef Mann R, Black D, Constine R, Daniels A. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg. 1985;10(6):1024–8.CrossRef
27.
go back to reference Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL. Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg. 2004;29(4):689–93.CrossRef Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL. Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg. 2004;29(4):689–93.CrossRef
28.
go back to reference Handoll H, Brealey S, Rangan A, Torgerson D, Dennis L, Armstrong A, Chuang L-H, Cross B, Dumville J, Gardner S. Protocol for the ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation) trial: a pragmatic multi-centre randomised controlled trial of surgical versus non-surgical treatment for proximal fracture of the humerus in adults. BMC Musculoskelet Disord. 2009;10(1):140.CrossRefPubMedPubMedCentral Handoll H, Brealey S, Rangan A, Torgerson D, Dennis L, Armstrong A, Chuang L-H, Cross B, Dumville J, Gardner S. Protocol for the ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation) trial: a pragmatic multi-centre randomised controlled trial of surgical versus non-surgical treatment for proximal fracture of the humerus in adults. BMC Musculoskelet Disord. 2009;10(1):140.CrossRefPubMedPubMedCentral
29.
go back to reference Handoll H, Keding A, Corbacho B, Brealey S, Hewitt C, Rangan A. Five-year follow-up results of the PROFHER trial comparing operative and non-operative treatment of adults with a displaced fracture of the proximal humerus. The Bone & Joint Journal. 2017;99(3):383–92.CrossRef Handoll H, Keding A, Corbacho B, Brealey S, Hewitt C, Rangan A. Five-year follow-up results of the PROFHER trial comparing operative and non-operative treatment of adults with a displaced fracture of the proximal humerus. The Bone & Joint Journal. 2017;99(3):383–92.CrossRef
30.
go back to reference Rangan A, Handoll H, Brealey S, Jefferson L, Keding A, Martin BC, Goodchild L, Chuang L-H, Hewitt C, Torgerson D. Surgical vs nonsurgical treatment of adults with displaced fractures of the proximal humerus: the PROFHER randomized clinical trial. JAMA. 2015;313(10):1037–47.CrossRefPubMed Rangan A, Handoll H, Brealey S, Jefferson L, Keding A, Martin BC, Goodchild L, Chuang L-H, Hewitt C, Torgerson D. Surgical vs nonsurgical treatment of adults with displaced fractures of the proximal humerus: the PROFHER randomized clinical trial. JAMA. 2015;313(10):1037–47.CrossRefPubMed
32.
go back to reference Sharma H, Taylor GR, Clarke NM. A review of K-wire related complications in the emergency management of paediatric upper extremity trauma. Ann R Coll Surg Engl. 2007;89(3):252–8.CrossRefPubMedPubMedCentral Sharma H, Taylor GR, Clarke NM. A review of K-wire related complications in the emergency management of paediatric upper extremity trauma. Ann R Coll Surg Engl. 2007;89(3):252–8.CrossRefPubMedPubMedCentral
34.
go back to reference Osteotomies MM, Müller ME, Allgöwer M, Schneider R, et al., editors. Manual of internal fixation: techniques recommended by the AO-ASIF Group. Berlin Heidelberg New York: Springer-Verlag; 1979. Osteotomies MM, Müller ME, Allgöwer M, Schneider R, et al., editors. Manual of internal fixation: techniques recommended by the AO-ASIF Group. Berlin Heidelberg New York: Springer-Verlag; 1979.
35.
go back to reference Kao F-C, Chao E-K, Chen C-H, Yu S-W, Chen C-Y, Yen C-Y. Treatment of distal clavicle fracture using Kirschner wires and tension-band wires. J Trauma Acute Care Surg. 2001;51(3):522–5.CrossRef Kao F-C, Chao E-K, Chen C-H, Yu S-W, Chen C-Y, Yen C-Y. Treatment of distal clavicle fracture using Kirschner wires and tension-band wires. J Trauma Acute Care Surg. 2001;51(3):522–5.CrossRef
36.
go back to reference Claessen F, van den Bekerom MPJ, van Dijk CN, Carel Goslings J, Kerkhoffs G, Doornberg JN. Tension band wiring for simple olecranon fractures: evaluation of surgical technique. J Orthop Traumatol : official journal of the Italian Society of Orthopaedics and Traumatology. 2017;18(3):275–81.CrossRef Claessen F, van den Bekerom MPJ, van Dijk CN, Carel Goslings J, Kerkhoffs G, Doornberg JN. Tension band wiring for simple olecranon fractures: evaluation of surgical technique. J Orthop Traumatol : official journal of the Italian Society of Orthopaedics and Traumatology. 2017;18(3):275–81.CrossRef
37.
go back to reference Ostrum RF, Litsky AS. Tension band fixation of medial malleolus fractures. J Orthop Trauma. 1992;6(4):464–8.CrossRefPubMed Ostrum RF, Litsky AS. Tension band fixation of medial malleolus fractures. J Orthop Trauma. 1992;6(4):464–8.CrossRefPubMed
38.
39.
go back to reference Zens M, Goldschmidtboeing F, Wagner F, Reising K, Sudkamp NP, Woias P. Polydimethylsiloxane pressure sensors for force analysis in tension band wiring of the olecranon. Technol Health Care : official journal of the European Society for Engineering and Medicine. 2016;24(6):909–17.CrossRef Zens M, Goldschmidtboeing F, Wagner F, Reising K, Sudkamp NP, Woias P. Polydimethylsiloxane pressure sensors for force analysis in tension band wiring of the olecranon. Technol Health Care : official journal of the European Society for Engineering and Medicine. 2016;24(6):909–17.CrossRef
40.
go back to reference Hiatt SV, Begonia MT, Thiagarajan G, Hutchison RL. Biomechanical comparison of 2 methods of intramedullary K-wire fixation of transverse metacarpal shaft fractures. J Hand Surg. 2015;40(8):1586–90.CrossRef Hiatt SV, Begonia MT, Thiagarajan G, Hutchison RL. Biomechanical comparison of 2 methods of intramedullary K-wire fixation of transverse metacarpal shaft fractures. J Hand Surg. 2015;40(8):1586–90.CrossRef
Metadata
Title
New fixation approach for transverse metacarpal neck fracture: a biomechanical study
Authors
Yung-Cheng Chiu
Ming-Tzu Tsai
Cheng-En Hsu
Horng-Chaung Hsu
Heng-Li Huang
Jui-Ting Hsu
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2018
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-018-0890-2

Other articles of this Issue 1/2018