Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2016

Open Access 01-12-2016 | Research article

Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis

Authors: Yi-Ming Ren, Hu-Yun Qiao, Zhi-Jian Wei, Wei Lin, Bao-You Fan, Jun Liu, Ang Li, Yi Kang, Shen Liu, Yan Hao, Xian-Hu Zhou, Shi-Qing Feng

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2016

Login to get access

Abstract

Background

Olecranon fracture (OF) is a common upper limb fracture, and the most commonly used techniques are still tension band wiring (TBW) and plate fixation (PF). The aim of the current study is to discuss whether TBW or PF technique of internal fixation is better in the treatment of OFs, using the method of meta-analysis.

Methods

The eligible studies were acquired from PubMed, CNKI, Embase, Cochrane Library, and other sources. The data were extracted by two of the coauthors independently and were analyzed by RevMan5.3. Standardized mean differences (SMDs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated. Cochrane Collaboration’s Risk of Bias Tool and Newcastle–Ottawa Scale were used to assess risk of bias.

Results

Thirteen studies including 1 RCT and 12 observational studies were assessed. Our meta-analysis results showed that both in RCT and observational studies, there were no significant differences between the two groups in disabilities of the arm, shoulder and hand (DASH) (SMD = 0.07, 95% CI = −0.32 to 0.46, p = 0.73), improvement rate (OR = 0.76, 95% CI = 0.48–1.22, p = 0.26), range of motion (ROM), operation time (SMD = −0.51, 95% CI = −1.17 to 0.14, p = 0.12) and blood loss (SMD = −0.97, 95% CI = −2.06 to 0.11, p = 0.08). The overall estimate of complications indicated that the pooled OR was 2.61 (95% CI = 1.65–4.14, p < 0.0001), suggesting that the difference was statistically significant. We also compared the outcomes of patients with mayo type IIA OFs treated by TBW and PF in DASH and ROM and found no differences.

Conclusions

Both TBW and PF interventions had treatment benefit in OFs. The current study reveals that there are no significant differences in DASH, improvement rate, ROM, operation time, and blood loss between TBW and PF for OFs. Due to the less complications, we recommend the PF approach as the optical choice for OFs. More high-quality studies are required to further confirm our results.
Literature
1.
go back to reference Rommens PM, et al. Olecranon fractures in adults: factors influencing outcome. Inj-Int, J Care Inj. 2004;35(11):1149–57.CrossRef Rommens PM, et al. Olecranon fractures in adults: factors influencing outcome. Inj-Int, J Care Inj. 2004;35(11):1149–57.CrossRef
2.
go back to reference Closkey RF, et al. The role of the coronoid process in elbow stability. J Bone Joint Surg Am. 2000;82(12):1749–53.CrossRefPubMed Closkey RF, et al. The role of the coronoid process in elbow stability. J Bone Joint Surg Am. 2000;82(12):1749–53.CrossRefPubMed
3.
go back to reference Amis AA, Miller JH. The mechanisms of elbow fractures: an investigation using impact tests in vitro. Inj-Int, J Care Inj. 1995;26(3):163–8.CrossRef Amis AA, Miller JH. The mechanisms of elbow fractures: an investigation using impact tests in vitro. Inj-Int, J Care Inj. 1995;26(3):163–8.CrossRef
4.
go back to reference Baecher N, Edwards S. Olecranon fractures. J Hand Surg. 2013;38(3):593–604.CrossRef Baecher N, Edwards S. Olecranon fractures. J Hand Surg. 2013;38(3):593–604.CrossRef
5.
go back to reference Wilkerson JA, Rosenwasser MP. Surgical techniques of olecranon fractures. J Hand Surg. 2014;39(8):1606–14.CrossRef Wilkerson JA, Rosenwasser MP. Surgical techniques of olecranon fractures. J Hand Surg. 2014;39(8):1606–14.CrossRef
6.
go back to reference Den HA, Heusinkveld M, Traa W, et al. Current techniques for management of transverse displaced olecranon fractures. Muscles. 2015;5(2):129–40. Den HA, Heusinkveld M, Traa W, et al. Current techniques for management of transverse displaced olecranon fractures. Muscles. 2015;5(2):129–40.
7.
go back to reference Traa WA, Oomen PJA, Hamer AD, et al. Biomechanical studies on transverse olecranon and patellar fractures: a systematic review with the development of a new scoring method. Br Med Bull. 2013;108(1):131–57.CrossRefPubMed Traa WA, Oomen PJA, Hamer AD, et al. Biomechanical studies on transverse olecranon and patellar fractures: a systematic review with the development of a new scoring method. Br Med Bull. 2013;108(1):131–57.CrossRefPubMed
8.
go back to reference Duckworth AD, et al. The epidemiology of fractures of the proximal ulna. Inj-Int J Care Inj. 2012;43(3):343–6.CrossRef Duckworth AD, et al. The epidemiology of fractures of the proximal ulna. Inj-Int J Care Inj. 2012;43(3):343–6.CrossRef
9.
go back to reference Colton CL. Fractures of the olecranon in adults: classification and management. Inj-Int J Care Inj. 1973;5(2):121–ĩbr.CrossRef Colton CL. Fractures of the olecranon in adults: classification and management. Inj-Int J Care Inj. 1973;5(2):121–ĩbr.CrossRef
10.
go back to reference Benedikt S, et al. Comparison of tension band wiring and precontoured locking compression plate fixation in mayo type IIA olecranon fractures. Acta Orthop Belg. 2014;80(1):106–11. Benedikt S, et al. Comparison of tension band wiring and precontoured locking compression plate fixation in mayo type IIA olecranon fractures. Acta Orthop Belg. 2014;80(1):106–11.
11.
go back to reference Tarallo L, et al. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. J Endourol. 2014;134(8):1107–14. Tarallo L, et al. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. J Endourol. 2014;134(8):1107–14.
12.
go back to reference Khann G, et al. A comparative study of tension band wiring and reconstruction plating in olecranon fractures. Pb Am J Orthop. 2012;8(1):57–61. Khann G, et al. A comparative study of tension band wiring and reconstruction plating in olecranon fractures. Pb Am J Orthop. 2012;8(1):57–61.
13.
go back to reference Hume MC, Wiss DA. Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop Relat Res. 1992;8(28):229–35. Hume MC, Wiss DA. Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop Relat Res. 1992;8(28):229–35.
14.
go back to reference Chen YH, et al. Case control study on therapeutic effects of different fixation methods for the treatment of olecranon fracture. China J Orthop Trauma. 2014;27(11):891–5. Chen YH, et al. Case control study on therapeutic effects of different fixation methods for the treatment of olecranon fracture. China J Orthop Trauma. 2014;27(11):891–5.
15.
go back to reference Lu JB, et al. The comparison of two internal fixations in treating olecranon fractures. Chin Clin Med. 2012;05(2):141–3. Lu JB, et al. The comparison of two internal fixations in treating olecranon fractures. Chin Clin Med. 2012;05(2):141–3.
16.
go back to reference Sui J, et al. Effect comparison of two kinds of therapeutic methods of olecranon fracture. China J Orthop Trauma. 2008;21(1):60–1. Sui J, et al. Effect comparison of two kinds of therapeutic methods of olecranon fracture. China J Orthop Trauma. 2008;21(1):60–1.
17.
go back to reference Wang YA, et al. Effect analysis of Kirschner wire tension band and anatomical plate fixation for olecranon fracture. Chin J Bone Joint Injury. 2014;29(3):296–7. Wang YA, et al. Effect analysis of Kirschner wire tension band and anatomical plate fixation for olecranon fracture. Chin J Bone Joint Injury. 2014;29(3):296–7.
18.
go back to reference Xu J, et al. Efficacy of tension band wiring and plate fixation in treatment of different types of olecranon fracture. Jiangsu Med. 2015;41(2):173–5. Xu J, et al. Efficacy of tension band wiring and plate fixation in treatment of different types of olecranon fracture. Jiangsu Med. 2015;41(2):173–5.
19.
go back to reference Yu RH, et al. Effect observation of olecranon plate fixation and tension band wiring in treatment of olecranon fracture. Chin J Bone Joint Injury. 2011;26(9):839–40. Yu RH, et al. Effect observation of olecranon plate fixation and tension band wiring in treatment of olecranon fracture. Chin J Bone Joint Injury. 2011;26(9):839–40.
20.
go back to reference Zhang J, et al. Evaluation on the effect of olecranon hook plate and tension band wire in treatment of olecranon fracture. Orthop Biomech Mater Clin Study. 2005;2(2):37–8. Zhang J, et al. Evaluation on the effect of olecranon hook plate and tension band wire in treatment of olecranon fracture. Orthop Biomech Mater Clin Study. 2005;2(2):37–8.
21.
go back to reference Zhang L, et al. Different methods of internal fixation in treatment of olecranon fracture. Int J Orthop. 2011;32(5):338–9. Zhang L, et al. Different methods of internal fixation in treatment of olecranon fracture. Int J Orthop. 2011;32(5):338–9.
22.
go back to reference Zhang XG, et al. The comparison of anatomical locking plate and tension band wiring in treating olecranon fractures. Chin J Bone Joint Injury. 2013;28(7):676–7. Zhang XG, et al. The comparison of anatomical locking plate and tension band wiring in treating olecranon fractures. Chin J Bone Joint Injury. 2013;28(7):676–7.
23.
go back to reference Chalidis BE, et al. Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3(3):1–6. Chalidis BE, et al. Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3(3):1–6.
24.
go back to reference Ikeda M, et al. Comminuted fractures of the olecranon. Management by bone graft from the iliac crest and multiple tension-band wiring. J Bone Joint Surg. 2001;83(6):805–8.CrossRef Ikeda M, et al. Comminuted fractures of the olecranon. Management by bone graft from the iliac crest and multiple tension-band wiring. J Bone Joint Surg. 2001;83(6):805–8.CrossRef
25.
go back to reference Chen LJ, Zheng W, Yu W. Treatment of olecranon fracture using Kirschner with a hole in the tail and tensile band wire. Zhongguo Gu Shang/China J Orthop Trauma. 2003;16(3):167–8. Chen LJ, Zheng W, Yu W. Treatment of olecranon fracture using Kirschner with a hole in the tail and tensile band wire. Zhongguo Gu Shang/China J Orthop Trauma. 2003;16(3):167–8.
26.
go back to reference Romero JM, Miran A, Jensen CH. Complications and re-operation rate after tension-band wiring of olecranon fractures. J Orthop Sci. 2000;5(4):318–20.CrossRefPubMed Romero JM, Miran A, Jensen CH. Complications and re-operation rate after tension-band wiring of olecranon fractures. J Orthop Sci. 2000;5(4):318–20.CrossRefPubMed
27.
go back to reference Gordon MJ, et al. Comminuted olecranon fractures: a comparison of plating methods. J Shoulder Elb Surg. 2006;15(1):94–9.CrossRef Gordon MJ, et al. Comminuted olecranon fractures: a comparison of plating methods. J Shoulder Elb Surg. 2006;15(1):94–9.CrossRef
28.
go back to reference Mouhsine E, et al. Transolecranon anterior fracture dislocation. J Shoulder Elb Surg. 2007;16(3):352–7.CrossRef Mouhsine E, et al. Transolecranon anterior fracture dislocation. J Shoulder Elb Surg. 2007;16(3):352–7.CrossRef
29.
go back to reference Lalliss SJ, Branstetter JG. The use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows. J Bone Joint Surg (Br). 2010;92(2):315–9.CrossRef Lalliss SJ, Branstetter JG. The use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows. J Bone Joint Surg (Br). 2010;92(2):315–9.CrossRef
30.
go back to reference Geert B, Peter K. Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures. J Bone Joint Surg Am. 2009;91(10):2416–20.CrossRef Geert B, Peter K. Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures. J Bone Joint Surg Am. 2009;91(10):2416–20.CrossRef
31.
go back to reference Wild JR, et al. Biomechanical evaluation of suture-augmented locking plate fixation for proximal third fractures of the olecranon. J Orthop Trauma. 2012;26(9):533–8. Wild JR, et al. Biomechanical evaluation of suture-augmented locking plate fixation for proximal third fractures of the olecranon. J Orthop Trauma. 2012;26(9):533–8.
Metadata
Title
Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis
Authors
Yi-Ming Ren
Hu-Yun Qiao
Zhi-Jian Wei
Wei Lin
Bao-You Fan
Jun Liu
Ang Li
Yi Kang
Shen Liu
Yan Hao
Xian-Hu Zhou
Shi-Qing Feng
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2016
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-016-0465-z

Other articles of this Issue 1/2016

Journal of Orthopaedic Surgery and Research 1/2016 Go to the issue