Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2015

Open Access 01-12-2015 | Research article

Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience

Authors: Ke-He Yu, Jian-Jun Hong, Xiao-Shan Guo, Dong-Sheng Zhou

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2015

Login to get access

Abstract

Objective

The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF).

Materials and Methods

Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated.

Results

The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18–54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score.

Conclusion

PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.
Literature
1.
go back to reference Ragnarsson B, Jacobsson B. Epidemiology of pelvic fractures in a Swedish county. Acta Orthop Scand. 1992;63(3):297–300.CrossRefPubMed Ragnarsson B, Jacobsson B. Epidemiology of pelvic fractures in a Swedish county. Acta Orthop Scand. 1992;63(3):297–300.CrossRefPubMed
2.
go back to reference Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res. 2007;22(3):465–75.CrossRefPubMed Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res. 2007;22(3):465–75.CrossRefPubMed
3.
go back to reference Inaba K, Sharkey PW, Stephen DJ, Redelmeier DA, Brenneman FD. The increasing incidence of severe pelvic injury in motor vehicle collisions. Injury. 2004;35(8):759–65.CrossRefPubMed Inaba K, Sharkey PW, Stephen DJ, Redelmeier DA, Brenneman FD. The increasing incidence of severe pelvic injury in motor vehicle collisions. Injury. 2004;35(8):759–65.CrossRefPubMed
4.
go back to reference Pohlemann T, Bosch U, Gansslen A, Tscherne H. The Hannover experience in management of pelvic fractures. Clin Orthop Relat Res. 1994;305:69–80.CrossRefPubMed Pohlemann T, Bosch U, Gansslen A, Tscherne H. The Hannover experience in management of pelvic fractures. Clin Orthop Relat Res. 1994;305:69–80.CrossRefPubMed
5.
go back to reference Putnis SE, Pearce R, Wali UJ, Bircher MD, Rickman MS. Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: one-year radiological and functional outcomes. J Bone Joint Surg Br. 2011;93(1):78–84.CrossRefPubMed Putnis SE, Pearce R, Wali UJ, Bircher MD, Rickman MS. Open reduction and internal fixation of a traumatic diastasis of the pubic symphysis: one-year radiological and functional outcomes. J Bone Joint Surg Br. 2011;93(1):78–84.CrossRefPubMed
6.
go back to reference Lange RH, Hansen Jr ST. Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation. Clin Orthop Relat Res. 1985;201:130–7.PubMed Lange RH, Hansen Jr ST. Pelvic ring disruptions with symphysis pubis diastasis. Indications, technique, and limitations of anterior internal fixation. Clin Orthop Relat Res. 1985;201:130–7.PubMed
7.
go back to reference Giannoudis PV, Chalidis BE, Roberts CS. Internal fixation of traumatic diastasis of pubic symphysis: is plate removal essential? Arch Orthop Trauma Surg. 2008;128(3):325–31.CrossRefPubMed Giannoudis PV, Chalidis BE, Roberts CS. Internal fixation of traumatic diastasis of pubic symphysis: is plate removal essential? Arch Orthop Trauma Surg. 2008;128(3):325–31.CrossRefPubMed
8.
go back to reference Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma. 2008;22(6):373–8.CrossRefPubMed Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma. 2008;22(6):373–8.CrossRefPubMed
9.
go back to reference Farouk O, Kamal A, Badran M, El-Adly W, El-Gafary K. Minimal invasive para-rectus approach for limited open reduction and percutaneous fixation of displaced acetabular fractures. Injury. 2014;45(6):995–9.CrossRefPubMed Farouk O, Kamal A, Badran M, El-Adly W, El-Gafary K. Minimal invasive para-rectus approach for limited open reduction and percutaneous fixation of displaced acetabular fractures. Injury. 2014;45(6):995–9.CrossRefPubMed
10.
go back to reference Sharma A, Jain PK, Shaw CJ, Sedman PC. Successful laparoscopic repair of a traumatic pubic symphysis hernia. Surg Endosc. 2004;18(2):345–9.CrossRefPubMed Sharma A, Jain PK, Shaw CJ, Sedman PC. Successful laparoscopic repair of a traumatic pubic symphysis hernia. Surg Endosc. 2004;18(2):345–9.CrossRefPubMed
11.
go back to reference Routt Jr ML, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res. 2000;375:15–29.CrossRefPubMed Routt Jr ML, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res. 2000;375:15–29.CrossRefPubMed
12.
go back to reference Chen L, Zhang G, Song D, Guo X, Yuan W. A comparison of percutaneous reduction and screw fixation versus open reduction and plate fixation of traumatic symphysis pubis diastasis. Arch Orthop Trauma Surg. 2012;132(2):265–70.CrossRefPubMed Chen L, Zhang G, Song D, Guo X, Yuan W. A comparison of percutaneous reduction and screw fixation versus open reduction and plate fixation of traumatic symphysis pubis diastasis. Arch Orthop Trauma Surg. 2012;132(2):265–70.CrossRefPubMed
13.
go back to reference Mu WD, Wang H, Zhou DS, Yu LZ, Jia TH, Li LX. Computer navigated percutaneous screw fixation for traumatic pubic symphysis diastasis of unstable pelvic ring injuries. Chin Med J (Engl). 2009;122(14):1699–703. Mu WD, Wang H, Zhou DS, Yu LZ, Jia TH, Li LX. Computer navigated percutaneous screw fixation for traumatic pubic symphysis diastasis of unstable pelvic ring injuries. Chin Med J (Engl). 2009;122(14):1699–703.
14.
go back to reference Tile M. Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br. 1988;70(1):1–12.PubMed Tile M. Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br. 1988;70(1):1–12.PubMed
15.
go back to reference Zhang L, Yang G, Wu L, Yu B. The biomechanical effects of osteoporosis vertebral augmentation with cancellous bone granules or bone cement on treated and adjacent non-treated vertebral bodies: a finite element evaluation. Clin Biomech (Bristol, Avon). 2010;25(2):166–72.CrossRef Zhang L, Yang G, Wu L, Yu B. The biomechanical effects of osteoporosis vertebral augmentation with cancellous bone granules or bone cement on treated and adjacent non-treated vertebral bodies: a finite element evaluation. Clin Biomech (Bristol, Avon). 2010;25(2):166–72.CrossRef
16.
go back to reference Vleeming A, Volkers AC, Snijders CJ, Stoeckart R. Relation between form and function in the sacroiliac joint. Part II: biomechanical aspects. Spine (Phila Pa 1976). 1990;15(2):133–6.CrossRef Vleeming A, Volkers AC, Snijders CJ, Stoeckart R. Relation between form and function in the sacroiliac joint. Part II: biomechanical aspects. Spine (Phila Pa 1976). 1990;15(2):133–6.CrossRef
17.
go back to reference Dalstra M, Huiskes R, Odgaard A, van Erning L. Mechanical and textural properties of pelvic trabecular bone. J Biomech. 1993;26(4–5):523–35.CrossRefPubMed Dalstra M, Huiskes R, Odgaard A, van Erning L. Mechanical and textural properties of pelvic trabecular bone. J Biomech. 1993;26(4–5):523–35.CrossRefPubMed
18.
go back to reference Zuo Z. Three-dimensional finite element analysis and biomechanics of sacroiliac complex, Medical Doctorship Thesis. Jinan, China: Shandong University; 2006. Zuo Z. Three-dimensional finite element analysis and biomechanics of sacroiliac complex, Medical Doctorship Thesis. Jinan, China: Shandong University; 2006.
19.
go back to reference Dalstra M, Huiskes R, van Erning L. Development and validation of a three-dimensional finite element model of the pelvic bone. J Biomech Eng. 1995;117(3):272–8.CrossRefPubMed Dalstra M, Huiskes R, van Erning L. Development and validation of a three-dimensional finite element model of the pelvic bone. J Biomech Eng. 1995;117(3):272–8.CrossRefPubMed
20.
go back to reference Mechlenburg I, Nyengaard JR, Gelineck J, Soballe K. Cartilage thickness in the hip joint measured by MRI and stereology—a methodological study. Osteoarthritis Cartilage. 2007;15(4):366–71.CrossRefPubMed Mechlenburg I, Nyengaard JR, Gelineck J, Soballe K. Cartilage thickness in the hip joint measured by MRI and stereology—a methodological study. Osteoarthritis Cartilage. 2007;15(4):366–71.CrossRefPubMed
21.
go back to reference Zhang L, Peng Y, Du C, Tang P. Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: a finite element analysis. Injury. 2014;45(12):2055–9.CrossRefPubMed Zhang L, Peng Y, Du C, Tang P. Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: a finite element analysis. Injury. 2014;45(12):2055–9.CrossRefPubMed
22.
go back to reference Simonian PT, Routt Jr ML, Harrington RM, Tencer AF. Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique. J Orthop Trauma. 1994;8(6):483–9.CrossRefPubMed Simonian PT, Routt Jr ML, Harrington RM, Tencer AF. Box plate fixation of the symphysis pubis: biomechanical evaluation of a new technique. J Orthop Trauma. 1994;8(6):483–9.CrossRefPubMed
23.
go back to reference Varga E, Hearn T, Powell J, Tile M. Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring. Injury. 1995;26(2):75–80.CrossRefPubMed Varga E, Hearn T, Powell J, Tile M. Effects of method of internal fixation of symphyseal disruptions on stability of the pelvic ring. Injury. 1995;26(2):75–80.CrossRefPubMed
24.
go back to reference Cano-Luis P, Giraldez-Sanchez MA, Martinez-Reina J, Serrano-Escalante FJ, Galleguillos-Rioboo C, Lazaro-Gonzalvez A, et al. Biomechanical analysis of a new minimally invasive system for osteosynthesis of pubis symphysis disruption. Injury. 2012;43 Suppl 2:S20–7.CrossRefPubMed Cano-Luis P, Giraldez-Sanchez MA, Martinez-Reina J, Serrano-Escalante FJ, Galleguillos-Rioboo C, Lazaro-Gonzalvez A, et al. Biomechanical analysis of a new minimally invasive system for osteosynthesis of pubis symphysis disruption. Injury. 2012;43 Suppl 2:S20–7.CrossRefPubMed
25.
go back to reference Wu AM, Wang XY, Zhao HZ, Lin SL, Xu HZ, Chi YL. An imaging study of the compressed area, bony fragment area, and the total fracture-involved area in thoracolumbar burst fractures. J Spinal Disord Tech. 2014;27(4):207–11.CrossRefPubMed Wu AM, Wang XY, Zhao HZ, Lin SL, Xu HZ, Chi YL. An imaging study of the compressed area, bony fragment area, and the total fracture-involved area in thoracolumbar burst fractures. J Spinal Disord Tech. 2014;27(4):207–11.CrossRefPubMed
26.
go back to reference Tian NF, Xu HZ, Wang XY, Chen QJ, Zheng LC. Morphometric comparisons between the pedicle and the pedicle rib unit in the immature Chinese thoracic spine: a computed tomographic assessment. Spine (Phila Pa 1976). 2010;35(16):1514–9.CrossRef Tian NF, Xu HZ, Wang XY, Chen QJ, Zheng LC. Morphometric comparisons between the pedicle and the pedicle rib unit in the immature Chinese thoracic spine: a computed tomographic assessment. Spine (Phila Pa 1976). 2010;35(16):1514–9.CrossRef
27.
go back to reference Majeed SA. Grading the outcome of pelvic fractures. J Bone Joint Surg Br. 1989;71(2):304–6.PubMed Majeed SA. Grading the outcome of pelvic fractures. J Bone Joint Surg Br. 1989;71(2):304–6.PubMed
28.
go back to reference Fitzgerald CA, Morse BC, Dente CJ. Pelvic ring fractures: has mortality improved following the implementation of damage control resuscitation? Am J Surg. 2014;208(6):1083–90. discussion 1089–1090.CrossRefPubMed Fitzgerald CA, Morse BC, Dente CJ. Pelvic ring fractures: has mortality improved following the implementation of damage control resuscitation? Am J Surg. 2014;208(6):1083–90. discussion 1089–1090.CrossRefPubMed
29.
go back to reference Hauschild O, Strohm PC, Culemann U, Pohlemann T, Suedkamp NP, Koestler W, et al. Mortality in patients with pelvic fractures: results from the German pelvic injury register. J Trauma. 2008;64(2):449–55.CrossRefPubMed Hauschild O, Strohm PC, Culemann U, Pohlemann T, Suedkamp NP, Koestler W, et al. Mortality in patients with pelvic fractures: results from the German pelvic injury register. J Trauma. 2008;64(2):449–55.CrossRefPubMed
30.
go back to reference Pohlemann T, Tscherne H, Baumgartel F, Egbers HJ, Euler E, Maurer F, et al. Pelvic fractures: epidemiology, therapy and long-term outcome. Overview of the multicenter study of the Pelvis Study Group. Unfallchirurg. 1996;99(3):160–7.PubMed Pohlemann T, Tscherne H, Baumgartel F, Egbers HJ, Euler E, Maurer F, et al. Pelvic fractures: epidemiology, therapy and long-term outcome. Overview of the multicenter study of the Pelvis Study Group. Unfallchirurg. 1996;99(3):160–7.PubMed
31.
go back to reference Young JW, Burgess AR, Brumback RJ, Poka A. Pelvic fractures: value of plain radiography in early assessment and management. Radiology. 1986;160(2):445–51.CrossRefPubMed Young JW, Burgess AR, Brumback RJ, Poka A. Pelvic fractures: value of plain radiography in early assessment and management. Radiology. 1986;160(2):445–51.CrossRefPubMed
32.
go back to reference Webb LX, Bosse MJ, Mayo KA, Lange RH, Miller ME, Swiontkowski MF. Results in patients with craniocerebral trauma and an operatively managed acetabular fracture. J Orthop Trauma. 1990;4(4):376–82.CrossRefPubMed Webb LX, Bosse MJ, Mayo KA, Lange RH, Miller ME, Swiontkowski MF. Results in patients with craniocerebral trauma and an operatively managed acetabular fracture. J Orthop Trauma. 1990;4(4):376–82.CrossRefPubMed
33.
go back to reference Taller S, Lukas R, Sram J. Single cannulated screws for stabilisation of pelvic ring and acetabular fractures. Acta Chir Orthop Traumatol Cech. 2011;78(6):568–77.PubMed Taller S, Lukas R, Sram J. Single cannulated screws for stabilisation of pelvic ring and acetabular fractures. Acta Chir Orthop Traumatol Cech. 2011;78(6):568–77.PubMed
34.
go back to reference Anderson AE, Peters CL, Tuttle BD, Weiss JA. Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. J Biomech Eng. 2005;127(3):364–73.CrossRefPubMed Anderson AE, Peters CL, Tuttle BD, Weiss JA. Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. J Biomech Eng. 2005;127(3):364–73.CrossRefPubMed
35.
go back to reference Phillips AT, Pankaj P, Howie CR, Usmani AS, Simpson AH. Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions. Med Eng Phys. 2007;29(7):739–48.CrossRefPubMed Phillips AT, Pankaj P, Howie CR, Usmani AS, Simpson AH. Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions. Med Eng Phys. 2007;29(7):739–48.CrossRefPubMed
36.
go back to reference Virkus WV, Goldberg SH, Lorenz EP. A comparison of compressive force generation by plating and intramedullary nailing techniques in a transverse diaphyseal humerus fracture model. J Trauma. 2008;65(1):103–8.CrossRefPubMed Virkus WV, Goldberg SH, Lorenz EP. A comparison of compressive force generation by plating and intramedullary nailing techniques in a transverse diaphyseal humerus fracture model. J Trauma. 2008;65(1):103–8.CrossRefPubMed
37.
go back to reference Rommens PM. Is there a role for percutaneous pelvic and acetabular reconstruction? Injury. 2007;38(4):463–77.CrossRefPubMed Rommens PM. Is there a role for percutaneous pelvic and acetabular reconstruction? Injury. 2007;38(4):463–77.CrossRefPubMed
38.
go back to reference Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond). 2005;55(6):498–500.CrossRef Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond). 2005;55(6):498–500.CrossRef
39.
go back to reference Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg. 2005;13(1):69–76.PubMed Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg. 2005;13(1):69–76.PubMed
Metadata
Title
Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience
Authors
Ke-He Yu
Jian-Jun Hong
Xiao-Shan Guo
Dong-Sheng Zhou
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2015
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-015-0272-y

Other articles of this Issue 1/2015