Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2015

Open Access 01-12-2015 | Research article

Mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study

Authors: Tahir Mutlu Duymus, Zafer Solak, Yusuf Ozturkmen, Ibrahim Azboy, Serhat Mutlu, Mustafa Caniklioglu

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2015

Login to get access

Abstract

Background

We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components.

Methods

The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39–87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indications for revision were femoral aseptic loosening in 38 (95 %) cases and acetabular protrusion in 2 (5 %). According to the Paprosky classification, the femoral defect was type 1 in 10 (25 %) patients, type 2 in 16 (40 %), type 3a in 11 (27.5 %), type 3b in 2 (5 %) and type 4 in 1 (2.5 %). The Harris hip score was used for the clinical evaluation. Femoral vertical subsidence, the cortical index and femoral stem stability were assessed radiologically. The mean follow-up period was 84 months (range 61–95 months).

Results

The mean Harris hip score was 41.4 (range 35.4–44.4) preoperatively and 80.9 (range 65.6–98.3) at the final follow-up examination (p < 0.05). Mean vertical subsidence was 5.7 mm (range 2.5–10.5 mm) in seven (17.5 %) patients. Stable bone fixation was observed in 38 (95 %) patients, fibrous stable fixation in 2 (5 %) and no instability in any patient. Radiographs taken during the early postoperative period revealed that the cortical index was a mean of 1.34 (range 1.11–1.73) and a mean of 1.55 on the final follow-up radiographic examinations (range 1.16–1.91) (p < 0.01).

Conclusions

Satisfactory results were achieved using uncemented modular femoral components during revision of previously cemented femoral components. Many modular femoral stems provide primary stability by filling femoral bone losses and help determine stem length, offset and anteversion.
Literature
1.
go back to reference Katz RP, Callaghan JJ, Sullivan PM, Johnston RC. Results of cemented femoral revision total hip arthroplasty using improved cementing techniques. Clin Orthop Relat Res. 1995;319:178–83.PubMed Katz RP, Callaghan JJ, Sullivan PM, Johnston RC. Results of cemented femoral revision total hip arthroplasty using improved cementing techniques. Clin Orthop Relat Res. 1995;319:178–83.PubMed
2.
go back to reference Haydon CM, Mehin R, Burnett S, et al. Revision total hip arthroplasty with use of a cemented femoral component. J Bone Joint Surg. 2004;86A:1179. Haydon CM, Mehin R, Burnett S, et al. Revision total hip arthroplasty with use of a cemented femoral component. J Bone Joint Surg. 2004;86A:1179.
3.
go back to reference Lakstein D, Eliaz N, Levi O, Backstein D, Kosashvili Y, Safir O, et al. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am. 2011;93(1):57–65.CrossRefPubMed Lakstein D, Eliaz N, Levi O, Backstein D, Kosashvili Y, Safir O, et al. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am. 2011;93(1):57–65.CrossRefPubMed
4.
go back to reference Paprosky WG. Femoral defect classification clinical application. Orthop Rev. 1990;21:9–15. Paprosky WG. Femoral defect classification clinical application. Orthop Rev. 1990;21:9–15.
5.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51(4):737–55.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51(4):737–55.PubMed
6.
go back to reference Sporer SM, Paprosky WG. Femoral fixation in the face of considerable bone loss: the use of modular stems. Clin Orthop Relat Res. 2004;429:227–31.CrossRefPubMed Sporer SM, Paprosky WG. Femoral fixation in the face of considerable bone loss: the use of modular stems. Clin Orthop Relat Res. 2004;429:227–31.CrossRefPubMed
7.
go back to reference Engh CA, Glassman AH, Suthers KE. The case for porous coated hip implants. The femoral side. Clin Orthop. 1990;261:63–81.PubMed Engh CA, Glassman AH, Suthers KE. The case for porous coated hip implants. The femoral side. Clin Orthop. 1990;261:63–81.PubMed
8.
go back to reference Callaghan JJ, Salvati EA, Pellicci PM, Wilson Jr PD, Ranawat CS. Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am. 1985;67(7):1074–85.PubMed Callaghan JJ, Salvati EA, Pellicci PM, Wilson Jr PD, Ranawat CS. Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg Am. 1985;67(7):1074–85.PubMed
9.
go back to reference Mulroy WF, Harris WH. Revision total hip arthroplasty with use of so-called second generation cementing techniques for aseptic loosening of the femoral component. A fifteen year average follow-up study. J Bone Joint Surg Am. 1996;78(3):325–30.PubMed Mulroy WF, Harris WH. Revision total hip arthroplasty with use of so-called second generation cementing techniques for aseptic loosening of the femoral component. A fifteen year average follow-up study. J Bone Joint Surg Am. 1996;78(3):325–30.PubMed
10.
go back to reference Kang MN, Huddleston JI, Hwang K, Imrie S, Goodman SB. Early outcome of a modular femoral component in revision total hip arthroplasty. J Arthroplasty. 2008;23:220–5. Kang MN, Huddleston JI, Hwang K, Imrie S, Goodman SB. Early outcome of a modular femoral component in revision total hip arthroplasty. J Arthroplasty. 2008;23:220–5.
11.
go back to reference Christie MJ, DeBoer DK, Tingstad EM, Capps M, Brinson MF, Trick LW. Clinical experience with a modular noncemented femoral component in revision total hip arthroplasty: 4- to 7-year results. J Arthroplasty. 2000;15:840–8. Christie MJ, DeBoer DK, Tingstad EM, Capps M, Brinson MF, Trick LW. Clinical experience with a modular noncemented femoral component in revision total hip arthroplasty: 4- to 7-year results. J Arthroplasty. 2000;15:840–8.
12.
go back to reference Mulliken BD, Rorabeck CH, Bourne RB. Uncemented revision total hip arthroplasty: a 4-to-6-year review. Clin Orthop Relat Res. 1996;325:156–62.CrossRefPubMed Mulliken BD, Rorabeck CH, Bourne RB. Uncemented revision total hip arthroplasty: a 4-to-6-year review. Clin Orthop Relat Res. 1996;325:156–62.CrossRefPubMed
13.
go back to reference Berry DJ, Harmsen WS, Ilstrup D, Lewallen DG, Cabanela ME. Survivorship of uncemented proximally porous-coated femoral components. Clin Orthop Relat Res. 1995;319:168–77.PubMed Berry DJ, Harmsen WS, Ilstrup D, Lewallen DG, Cabanela ME. Survivorship of uncemented proximally porous-coated femoral components. Clin Orthop Relat Res. 1995;319:168–77.PubMed
14.
go back to reference Schuh A, Werbwer S, Ulrich H, Zeiler G. Cementless modular hip arthroplasty using the MRP titan revision stem: outcome of 79 hips after an average of 4 years follow-up. Arch Orthop Trauma Surg. 2004;124:306–9.CrossRefPubMed Schuh A, Werbwer S, Ulrich H, Zeiler G. Cementless modular hip arthroplasty using the MRP titan revision stem: outcome of 79 hips after an average of 4 years follow-up. Arch Orthop Trauma Surg. 2004;124:306–9.CrossRefPubMed
15.
go back to reference Gross AE, Hutchison CR. Proximal femoral allografts for reconstruction of bone stock in revision arthroplasty of the hip. Orthop Clin North Am. 1998;29:313–7.CrossRefPubMed Gross AE, Hutchison CR. Proximal femoral allografts for reconstruction of bone stock in revision arthroplasty of the hip. Orthop Clin North Am. 1998;29:313–7.CrossRefPubMed
16.
go back to reference Canovas F, Girard J, Roche O, Migaud H, Bonnomet F, Goldschild M, et al. Bone stock in revision femoral arthroplasty: a new evaluation. Int Orthop. 2015;39:1487–94.CrossRefPubMed Canovas F, Girard J, Roche O, Migaud H, Bonnomet F, Goldschild M, et al. Bone stock in revision femoral arthroplasty: a new evaluation. Int Orthop. 2015;39:1487–94.CrossRefPubMed
17.
go back to reference Chandler HP, Ayres DK, Tan RC, Anderson LC, Varma AK. Revision total hip replacement using the S-ROM femoral component. Clin Orthop. 1995;319:130–40.PubMed Chandler HP, Ayres DK, Tan RC, Anderson LC, Varma AK. Revision total hip replacement using the S-ROM femoral component. Clin Orthop. 1995;319:130–40.PubMed
18.
go back to reference McLaughlin JR, Harris WH. Revision of the femoral component of a total hip arthroplasty with the calcar-replacement femoral component. Results after a mean of 10.8 years postoperatively. J Bone Joint Surg Am. 1996;78:331–9.PubMed McLaughlin JR, Harris WH. Revision of the femoral component of a total hip arthroplasty with the calcar-replacement femoral component. Results after a mean of 10.8 years postoperatively. J Bone Joint Surg Am. 1996;78:331–9.PubMed
19.
go back to reference Le Béguec P, Canovas F, Roche O, Goldschild M, Batard J. Uncemented femoral stems for revision surgery. Switzerland: Springer International Publishing; 2014. Le Béguec P, Canovas F, Roche O, Goldschild M, Batard J. Uncemented femoral stems for revision surgery. Switzerland: Springer International Publishing; 2014.
20.
go back to reference Wirtz DC, Heller KD, Holzwarth U, Siebert C, Pitto RP, Zeiler G, et al. A modular femoral implant for uncemented stem revision in THR. Int Orthop. 2000;24(3):134–8.PubMedCentralCrossRefPubMed Wirtz DC, Heller KD, Holzwarth U, Siebert C, Pitto RP, Zeiler G, et al. A modular femoral implant for uncemented stem revision in THR. Int Orthop. 2000;24(3):134–8.PubMedCentralCrossRefPubMed
21.
go back to reference Girard J, Roche O, Wavreille G, Canovas F, Le Béguec P. Stem subsidence after total hip revision: 183 cases at 5.9 years follow-up. Orthop Traumatol Surg Res. 2011;97(2):121–6.CrossRefPubMed Girard J, Roche O, Wavreille G, Canovas F, Le Béguec P. Stem subsidence after total hip revision: 183 cases at 5.9 years follow-up. Orthop Traumatol Surg Res. 2011;97(2):121–6.CrossRefPubMed
22.
go back to reference Del Alamo JG, Garcia-Cimbrelo E, Castellanos V, Garay EG. Radiographic bone regeneration and clinical outcome with the Wagner SL, revision stem: a 5-year to 12 year follow up study. J Arthroplasty. 2007;22(4):515–24.CrossRef Del Alamo JG, Garcia-Cimbrelo E, Castellanos V, Garay EG. Radiographic bone regeneration and clinical outcome with the Wagner SL, revision stem: a 5-year to 12 year follow up study. J Arthroplasty. 2007;22(4):515–24.CrossRef
23.
go back to reference Böhm P, Bischel O. Femoral revision with the Wagner SL revision stem, evaluation of one hundred and twenty nine revisions followed for a mean of 4.8 years. J Bone Joint Surg. 2001;83-A:1023–31.PubMed Böhm P, Bischel O. Femoral revision with the Wagner SL revision stem, evaluation of one hundred and twenty nine revisions followed for a mean of 4.8 years. J Bone Joint Surg. 2001;83-A:1023–31.PubMed
24.
go back to reference McInnis DP, Horne G, Devane PA. Femoral revision with a fluted, tapered, modular stem seventy patients followed for a mean of 3.9 years. J Arthroplasty. 2006;21(3):372–80.CrossRefPubMed McInnis DP, Horne G, Devane PA. Femoral revision with a fluted, tapered, modular stem seventy patients followed for a mean of 3.9 years. J Arthroplasty. 2006;21(3):372–80.CrossRefPubMed
25.
go back to reference Rodriguez JA, Fada R, Murphy SB, Rasquinha VJ, Ranawat CS. Two-year to five-year follow-up of femoral defects in femoral revision treated with the link MP modular stem. J Arthroplasty. 2009;24(5):751.CrossRefPubMed Rodriguez JA, Fada R, Murphy SB, Rasquinha VJ, Ranawat CS. Two-year to five-year follow-up of femoral defects in femoral revision treated with the link MP modular stem. J Arthroplasty. 2009;24(5):751.CrossRefPubMed
26.
go back to reference Paprosky WG, Greidanus NV, Antoniou J. Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop Relat Res. 1999;369:230–42.CrossRefPubMed Paprosky WG, Greidanus NV, Antoniou J. Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop Relat Res. 1999;369:230–42.CrossRefPubMed
27.
go back to reference Weiss RJ, Beckman MO, Enocson A, Schmalholz A, Stark A. Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty. J Arthroplasty. 2011;26(1):16–23.CrossRefPubMed Weiss RJ, Beckman MO, Enocson A, Schmalholz A, Stark A. Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty. J Arthroplasty. 2011;26(1):16–23.CrossRefPubMed
28.
go back to reference Morscher E. Experience with the press-fit cup and press-fit gliding stem. In: Kusswetter W, editor. Proceedings of International Symposium; 1990. Tübingen, Germany. New-York, Stuttgart: Thieme; 1991. p. 221–31. Morscher E. Experience with the press-fit cup and press-fit gliding stem. In: Kusswetter W, editor. Proceedings of International Symposium; 1990. Tübingen, Germany. New-York, Stuttgart: Thieme; 1991. p. 221–31.
29.
go back to reference Wirtz DC, Heller KD, Holzwarth U, Siebert C, Pitto RP. Zeiler G, et al. A modular femoral implant for uncemented stem revision in THR. 2000;24(3):134–8. Wirtz DC, Heller KD, Holzwarth U, Siebert C, Pitto RP. Zeiler G, et al. A modular femoral implant for uncemented stem revision in THR. 2000;24(3):134–8.
30.
go back to reference Palumbo BT, Morrison KL, Baumgarten AS, Stein MI, Haidukewych GJ, Bernasek TL. Results of revision total hip arthroplasty with modular, titanium-tapered femoral stems in severe proximal metaphyseal and diaphyseal bone loss. J Arthroplasty. 2013;28:690–4. Palumbo BT, Morrison KL, Baumgarten AS, Stein MI, Haidukewych GJ, Bernasek TL. Results of revision total hip arthroplasty with modular, titanium-tapered femoral stems in severe proximal metaphyseal and diaphyseal bone loss. J Arthroplasty. 2013;28:690–4.
31.
go back to reference Malkani AL, Lewallen DG, Cabanela ME, Wallrichs SL. Femoral component revision using an uncemented, proximally coated, long-stem prosthesis. J Arthroplasty. 1996;11(4):411–8.CrossRefPubMed Malkani AL, Lewallen DG, Cabanela ME, Wallrichs SL. Femoral component revision using an uncemented, proximally coated, long-stem prosthesis. J Arthroplasty. 1996;11(4):411–8.CrossRefPubMed
32.
33.
go back to reference Davidson D, Pike J, Garbuz D, Duncan CP. Masri Intraoperative periprosthetic fractures during total hip arthroplasty. Evaluation and management. J Bone Joint Surg Am. 2008;90(9):2000–12.CrossRefPubMed Davidson D, Pike J, Garbuz D, Duncan CP. Masri Intraoperative periprosthetic fractures during total hip arthroplasty. Evaluation and management. J Bone Joint Surg Am. 2008;90(9):2000–12.CrossRefPubMed
Metadata
Title
Mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
Authors
Tahir Mutlu Duymus
Zafer Solak
Yusuf Ozturkmen
Ibrahim Azboy
Serhat Mutlu
Mustafa Caniklioglu
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2015
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-015-0266-9

Other articles of this Issue 1/2015

Journal of Orthopaedic Surgery and Research 1/2015 Go to the issue