Skip to main content
Top
Published in: Diagnostic Pathology 1/2016

Open Access 01-12-2016 | Research

Diagnostic efficacy of cell block method for vitreoretinal lymphoma

Authors: Satoru Kase, Kenichi Namba, Daiju Iwata, Kazuomi Mizuuchi, Nobuyoshi Kitaichi, Yoshiaki Tagawa, Hiromi Okada-Kanno, Yoshihiro Matsuno, Susumu Ishida

Published in: Diagnostic Pathology | Issue 1/2016

Login to get access

Abstract

Background

Vitreoretinal lymphoma (VRL) is a life- and sight-threatening disorder. The aim of this study was to analyze the usefulness of the cell block method for diagnosis of VRL.

Methods

Sixteen eyes in 12 patients with VRL, and 4 eyes in 4 patients with idiopathic uveitis presenting with vitreous opacity were enrolled in this study. Both undiluted vitreous and diluted fluids were isolated during micro-incision vitrectomy. Cell block specimens were prepared in 19 eyes from diluted fluid containing shredding vitreous. These specimens were then submitted for HE staining as well as immunocytological analyses with antibodies against the B-cell marker CD20, the T-cell marker CD3, and cell proliferation marker Ki67. Conventional smear cytology was applied in 14 eyes with VRL using undiluted vitreous samples. The diagnosis of VRL was made based on the results of cytology, concentrations of interleukin (IL)-10 and IL-6 in undiluted vitreous, and immunoglobulin heavy chain gene rearrangement analysis.

Results

Atypical lymphoid cells were identified in 14 out of 15 cell block specimens of VRL (positive rate: 93.3 %), but in 5 out of 14 eyes in conventional smear cytology (positive rate: 35.7 %). Atypical lymphoid cells showed immunoreactivity for CD20 and Ki67. Seven cell block specimens were smear cytology-negative and cell block-positive. The cell block method showed no atypical lymphoid cells in any patient with idiopathic uveitis.

Conclusions

Cell block specimens using diluted vitreous fluid demonstrated a high diagnostic sensitivity and a low pseudo-positive rate for the cytological diagnosis of VRL. The cell block method contributed to clear differentiation between VRL and idiopathic uveitis with vitreous opacity.
Appendix
Available only for authorised users
Literature
7.
go back to reference Zaldivar RA, Martin DF, Holden JT, Grossniklaus HE. Primary intraocular lymphoma: clinical, cytologic, and flow cytometric analysis. Ophthalmology. 2004;111(9):1762–7.PubMed Zaldivar RA, Martin DF, Holden JT, Grossniklaus HE. Primary intraocular lymphoma: clinical, cytologic, and flow cytometric analysis. Ophthalmology. 2004;111(9):1762–7.PubMed
8.
go back to reference Sugita S, Takase H, Sugamoto Y, Arai A, Miura O, Mochizuki M. Diagnosis of intraocular lymphoma by polymerase chain reaction analysis and cytokine profiling of the vitreous fluid. Jpn J Ophthalmol. 2009;53(3):209–14.CrossRefPubMed Sugita S, Takase H, Sugamoto Y, Arai A, Miura O, Mochizuki M. Diagnosis of intraocular lymphoma by polymerase chain reaction analysis and cytokine profiling of the vitreous fluid. Jpn J Ophthalmol. 2009;53(3):209–14.CrossRefPubMed
11.
go back to reference Shivakumarswamy U, Arakeri SU, Karigowdar MH, Yelikar B. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology. J Cytol Indian Acad Cytol. 2012;29(1):11–5. doi:10.4103/0970-9371.93210.CrossRef Shivakumarswamy U, Arakeri SU, Karigowdar MH, Yelikar B. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology. J Cytol Indian Acad Cytol. 2012;29(1):11–5. doi:10.​4103/​0970-9371.​93210.CrossRef
12.
go back to reference Kimura K, Usui Y, Goto H, Japanese Intraocular Lymphoma Study G. Clinical features and diagnostic significance of the intraocular fluid of 217 patients with intraocular lymphoma. Jpn J Ophthalmol. 2012;56(4):383–9. doi:10.1007/s10384-012-0150-7.CrossRefPubMed Kimura K, Usui Y, Goto H, Japanese Intraocular Lymphoma Study G. Clinical features and diagnostic significance of the intraocular fluid of 217 patients with intraocular lymphoma. Jpn J Ophthalmol. 2012;56(4):383–9. doi:10.​1007/​s10384-012-0150-7.CrossRefPubMed
15.
go back to reference Van Ginderdeuren R, Van Calster J, Stalmans P, Van den Oord J. A new and standardized method to sample and analyse vitreous samples by the Cellient automated cell block system. Acta Ophthalmol. 2014;92(5):e388–92. doi:10.1111/aos.12360.CrossRefPubMed Van Ginderdeuren R, Van Calster J, Stalmans P, Van den Oord J. A new and standardized method to sample and analyse vitreous samples by the Cellient automated cell block system. Acta Ophthalmol. 2014;92(5):e388–92. doi:10.​1111/​aos.​12360.CrossRefPubMed
Metadata
Title
Diagnostic efficacy of cell block method for vitreoretinal lymphoma
Authors
Satoru Kase
Kenichi Namba
Daiju Iwata
Kazuomi Mizuuchi
Nobuyoshi Kitaichi
Yoshiaki Tagawa
Hiromi Okada-Kanno
Yoshihiro Matsuno
Susumu Ishida
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Diagnostic Pathology / Issue 1/2016
Electronic ISSN: 1746-1596
DOI
https://doi.org/10.1186/s13000-016-0479-1

Other articles of this Issue 1/2016

Diagnostic Pathology 1/2016 Go to the issue