A technical support tool for joint range of motion determination in functional diagnostics - an inter-rater study

Authors: Christoph Schiefer, Thomas Kraus, Rolf P Ellegast, Elke Ochsmann

Published in: Journal of Occupational Medicine and Toxicology | Issue 1/2015

Login to get access

Abstract

Background

The examination of joint range of motion (RoM) is part of musculo-skeletal functional diagnostics, used, for example, in occupational examinations. Various examination methodologies exist that have been optimized for occupational medical practice, which means they were reduced to the most necessary and feasible measures and examinations for efficiency and usability reasons. Because of time constraints in medical examinations in occupational settings, visual inspection is commonly used to quantify joint RoM. To support medical examiners, an inertial sensor-based measurement system (CUELA) was adapted for joint RoM examination in these settings. The objective of the present study was to evaluate the measurement tool in functional diagnostics under conditions close to clinical practice.

Methods

The joint RoM of twenty healthy subjects were examined by three physicians, who were simultaneously using the measurement tool. Physicians were blinded to the measurement results and the other physicians. Active RoM was examined on the cervical, thoracic and lumbar spine while passive RoM was examined on the shoulder, elbow, wrist, hip, and knee, resulting in a total of 40 joint examination angles. The means, standard deviations, intraclass correlation coefficients (I C C 3,k ), and Bland-Altman-Plots were calculated using MatLab for statistical analysis.

Results

Most measurement results were in accordance with expected joint RoMs. All examinations showed an acceptable repeatability. In active RoM examinations, the ICC of inter-rater reliability varied between 0.79 and 0.95. In passive RoM examination the ICC varied between 0.71 and 0.96, except examination angles at the elbow and knee extension (ICC: 0.0-0.77).

Conclusion

The reliability and objectivity of active RoM examinations were improved by the measurement tool compared with examiners. In passive RoM examinations of upper and lower extremities, the increase of objectivity by the measurements was limited for some examination angles by external factors such as the individual examiner impact on motion execution or the given joint examination conditions. Especially the elbow joint examination requires further development to achieve acceptable reliability. A modification in the examination method to reduce the examiner impact on measurement and the implementation of a more complex calibration procedure could improve the objectivity and reliability of the measurement tool in passive joint RoM examination to be applicable on nearly the whole body.
Literature
1.
go back to reference BMAS. Sicherheit und Gesundheit Bei der Arbeit 2012 - Unfallverhuetungsbericht Arbeit: Bundesministerium fuer Arbeit und Soziales (BMAS) und Bundesanstalt fuer Arbeitsschutz und Arbeitsmedizin (BAuA); 2013. www.baua.de/dok/4747830. BMAS. Sicherheit und Gesundheit Bei der Arbeit 2012 - Unfallverhuetungsbericht Arbeit: Bundesministerium fuer Arbeit und Soziales (BMAS) und Bundesanstalt fuer Arbeitsschutz und Arbeitsmedizin (BAuA); 2013. www.​baua.​de/​dok/​4747830.
3.
go back to reference Spallek M, Kuhn W, Schwarze S, Hartmann B. Occupational medical prophylaxis for the musculoskeletal system: A function-oriented system for physical examination of the locomotor system in occupational medicine fokus. Occup Med Toxicol. 2007; 2:12. doi:10.1186/1745-6673-2-12.CrossRef Spallek M, Kuhn W, Schwarze S, Hartmann B. Occupational medical prophylaxis for the musculoskeletal system: A function-oriented system for physical examination of the locomotor system in occupational medicine fokus. Occup Med Toxicol. 2007; 2:12. doi:10.1186/1745-6673-2-12.CrossRef
4.
go back to reference Grifka J, Linhardt O, Liebers F. Mehrstufendiagnostik von Muskel-Skelett-Erkrankungen in der Arbeitsmedizinischen Praxis, 2nd edn. Dortmund/Berlin/Dresden, Germany: Wirtschaftsverlag NW; 2005. http://www.baua.de/cae/servlet/contentblob/682540/publicationFile/46952/S62.pdf. Grifka J, Linhardt O, Liebers F. Mehrstufendiagnostik von Muskel-Skelett-Erkrankungen in der Arbeitsmedizinischen Praxis, 2nd edn. Dortmund/Berlin/Dresden, Germany: Wirtschaftsverlag NW; 2005. http://​www.​baua.​de/​cae/​servlet/​contentblob/​682540/​publicationFile/​46952/​S62.​pdf.
5.
go back to reference Holm I, Bolstad B, Lutken T, Ervik A, Rokkum M, Steen H. Reliability of goniometric measurements and visual estimates of hip rom in patients with osteoarthrosis. Physiother Res Int. 2000; 5:241–8. doi:10.1002/pri.204.CrossRefPubMed Holm I, Bolstad B, Lutken T, Ervik A, Rokkum M, Steen H. Reliability of goniometric measurements and visual estimates of hip rom in patients with osteoarthrosis. Physiother Res Int. 2000; 5:241–8. doi:10.1002/pri.204.CrossRefPubMed
6.
go back to reference Lowe BD. Accuracy and validity of observational estimates of wrist and forearm posture. Ergonomics. 2004; 47:527–4. doi:10.1080/00140130310001653057.CrossRefPubMed Lowe BD. Accuracy and validity of observational estimates of wrist and forearm posture. Ergonomics. 2004; 47:527–4. doi:10.1080/00140130310001653057.CrossRefPubMed
7.
go back to reference Lowe BD. Accuracy and validity of observational estimates of shoulder and elbow posture. Appl Ergonomics. 2004; 35:159–71. doi:10.1016/j.apergo.2004.01.003.CrossRef Lowe BD. Accuracy and validity of observational estimates of shoulder and elbow posture. Appl Ergonomics. 2004; 35:159–71. doi:10.1016/j.apergo.2004.01.003.CrossRef
8.
go back to reference Bergmann JH, Mayagoitia RE, Smith IC. A portable system for collecting anatomical joint angles during stair ascent: a comparison with an optical tracking device. Dyn Med. 2009; 8:3. doi:10.1186/1476-5918-8-3.CrossRefPubMedCentralPubMed Bergmann JH, Mayagoitia RE, Smith IC. A portable system for collecting anatomical joint angles during stair ascent: a comparison with an optical tracking device. Dyn Med. 2009; 8:3. doi:10.1186/1476-5918-8-3.CrossRefPubMedCentralPubMed
9.
go back to reference Theobald PSa, Jones MDa, Williams JMb. Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?Man Ther. 2012; 17(1):92–6.CrossRefPubMed Theobald PSa, Jones MDa, Williams JMb. Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?Man Ther. 2012; 17(1):92–6.CrossRefPubMed
10.
go back to reference Yun X, Bachmann ER, McGhee RB. A simplified quaternion-based algorithm for orientation estimation from earth gravity and magnetic field measurements. IEEE Trans Instrum Measurement. 2008; 57(3):638–50. doi:10.1109/TIM.2007.911646.CrossRef Yun X, Bachmann ER, McGhee RB. A simplified quaternion-based algorithm for orientation estimation from earth gravity and magnetic field measurements. IEEE Trans Instrum Measurement. 2008; 57(3):638–50. doi:10.1109/TIM.2007.911646.CrossRef
11.
go back to reference Favre Ja, Aissaoui Rab, Jolles BMc, de Guise JAb, Aminian Ka. Functional calibration procedure for 3d knee joint angle description using inertial sensors. J Biomech. 2008; 42(14):2330–335.CrossRef Favre Ja, Aissaoui Rab, Jolles BMc, de Guise JAb, Aminian Ka. Functional calibration procedure for 3d knee joint angle description using inertial sensors. J Biomech. 2008; 42(14):2330–335.CrossRef
12.
go back to reference Jordan K, Dziedzic K, Jones PW, Ong BN, Dawes PT. The reliability of the three-dimensional fastrak measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. Rheumatolo (Oxford). 2000; 39(4):382–8.CrossRef Jordan K, Dziedzic K, Jones PW, Ong BN, Dawes PT. The reliability of the three-dimensional fastrak measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. Rheumatolo (Oxford). 2000; 39(4):382–8.CrossRef
14.
go back to reference Parel Iab, Cutti AGa, Fiumana Gc, Porcellini Gc, Verni Ga, Accardo APb. Ambulatory measurement of the scapulohumeral rhythm: Intra- and inter-operator agreement of a protocol based on inertial and magnetic sensors. Gait Posture. 2012; 35(4):636–40.CrossRefPubMed Parel Iab, Cutti AGa, Fiumana Gc, Porcellini Gc, Verni Ga, Accardo APb. Ambulatory measurement of the scapulohumeral rhythm: Intra- and inter-operator agreement of a protocol based on inertial and magnetic sensors. Gait Posture. 2012; 35(4):636–40.CrossRefPubMed
15.
go back to reference Bachmann ER, Yun X, Peterson CW. An investigation of the effects of magnetic variations on inertial/magnetic orientation sensors. In: IEEE International Conference on Robotics and Automation. New Orleans, LA, USA: IEEE: 2004. p. 1115–1122. doi:10.1109/ROBOT.2004.1307974. Bachmann ER, Yun X, Peterson CW. An investigation of the effects of magnetic variations on inertial/magnetic orientation sensors. In: IEEE International Conference on Robotics and Automation. New Orleans, LA, USA: IEEE: 2004. p. 1115–1122. doi:10.1109/ROBOT.2004.1307974.
16.
go back to reference Nussbaumer S, Leunig M, Glatthorn J, Stauffacher S, Gerber H, Maffiuletti N. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients. BMC Musculoskelet Dis. 2010;11. doi:10.1186/1471-2474-11-194. Nussbaumer S, Leunig M, Glatthorn J, Stauffacher S, Gerber H, Maffiuletti N. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients. BMC Musculoskelet Dis. 2010;11. doi:10.1186/1471-2474-11-194.
17.
go back to reference Schiefer C, Ellegast R, Hermanns I, Kraus T, Ochsmann E, Larue C, et al. Optimization of inertial sensor-based motion capturing for magnetically distorted field applications. J Biomechanical Eng.2014;136(12). doi:10.1115/1.4028822. Schiefer C, Ellegast R, Hermanns I, Kraus T, Ochsmann E, Larue C, et al. Optimization of inertial sensor-based motion capturing for magnetically distorted field applications. J Biomechanical Eng.2014;136(12). doi:10.1115/1.4028822.
18.
go back to reference Faber GS, Chang CC, Rizun P, Dennerlein JT. A novel method for assessing the 3-d orientation accuracy of inertial/magnetic sensors. J Biomech. 2013; 46:2745–751.CrossRefPubMed Faber GS, Chang CC, Rizun P, Dennerlein JT. A novel method for assessing the 3-d orientation accuracy of inertial/magnetic sensors. J Biomech. 2013; 46:2745–751.CrossRefPubMed
19.
go back to reference Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, et al.ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part I: ankle, hip, and spine. J Biomech. 2002; 35(4):543–8. doi:10.1016/S0021-9290(01)00222-6.CrossRefPubMed Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, et al.ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part I: ankle, hip, and spine. J Biomech. 2002; 35(4):543–8. doi:10.1016/S0021-9290(01)00222-6.CrossRefPubMed
20.
go back to reference Wu G, van der Helm FCT, Veeger HEJD, Makhsous M, Roy PV, Anglin C, et al.ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - part II: shoulder, elbow, wrist and hand. J Biomech. 2005; 38(5):981–2. doi:10.1016/j.jbiomech.2004.05.042.CrossRefPubMed Wu G, van der Helm FCT, Veeger HEJD, Makhsous M, Roy PV, Anglin C, et al.ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - part II: shoulder, elbow, wrist and hand. J Biomech. 2005; 38(5):981–2. doi:10.1016/j.jbiomech.2004.05.042.CrossRefPubMed
21.
go back to reference Ellegast R, Hermanns I, Schiefer C. Workload assessment in field using the ambulatory CUELA system In: Duffy VG, editor. Digital Human Modeling, Lecture Notes in Computer Science. San Diego: Springer: 2009. p. 221–6. doi:10.1007/978-3-642-02809-0_24. Ellegast R, Hermanns I, Schiefer C. Workload assessment in field using the ambulatory CUELA system In: Duffy VG, editor. Digital Human Modeling, Lecture Notes in Computer Science. San Diego: Springer: 2009. p. 221–6. doi:10.1007/978-3-642-02809-0_24.
22.
go back to reference In: (Milde J, editor.)Guidelines for occupational medical examinations, 1st ed. Stuttgart, Germany: German Social Accident Insurance (DGUV); 2007. In: (Milde J, editor.)Guidelines for occupational medical examinations, 1st ed. Stuttgart, Germany: German Social Accident Insurance (DGUV); 2007.
23.
go back to reference Spallek M, Kuhn W. Funktionsorientierte Koerperliche Untersuchungssystematik: Die fokus-Methode zur Beurteilung des Bewegungsapparates in der Arbeits- und Allgemeinmedizin. Heidelberg, Muenchen, Landsberg, Frechen, Hamburg; Germany: ecomed; 2009. http://amzn.com/3609163968. Spallek M, Kuhn W. Funktionsorientierte Koerperliche Untersuchungssystematik: Die fokus-Methode zur Beurteilung des Bewegungsapparates in der Arbeits- und Allgemeinmedizin. Heidelberg, Muenchen, Landsberg, Frechen, Hamburg; Germany: ecomed; 2009. http://​amzn.​com/​3609163968.
24.
go back to reference Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomechanical Eng. 1983; 105(2):136–44.CrossRef Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomechanical Eng. 1983; 105(2):136–44.CrossRef
25.
go back to reference de Vries WHK, Veeger HEJ, Cutti AG, Baten C, van der Helm FCT. Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems. J Biomech. 2010; 43(10):1983–1988. doi:10.1016/j.jbiomech.2010.03.007.CrossRefPubMed de Vries WHK, Veeger HEJ, Cutti AG, Baten C, van der Helm FCT. Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems. J Biomech. 2010; 43(10):1983–1988. doi:10.1016/j.jbiomech.2010.03.007.CrossRefPubMed
26.
go back to reference Wolff HD, Lonquich C. Einfache messmethode der hws-funktion nach der neutral-null-methode. Manuelle Medizin. 2000; 38(5):284–8. doi:10.1007/s003370070014.CrossRef Wolff HD, Lonquich C. Einfache messmethode der hws-funktion nach der neutral-null-methode. Manuelle Medizin. 2000; 38(5):284–8. doi:10.1007/s003370070014.CrossRef
27.
go back to reference Amiri M, Jull G, Bullock-Saxton J. Measuring range of active cervical rotation in a position of full head flexion using the 3d fastrak measurement system: an intra-tester reliability study.Manual Therapy. 2003; 8(3):176–9.CrossRefPubMed Amiri M, Jull G, Bullock-Saxton J. Measuring range of active cervical rotation in a position of full head flexion using the 3d fastrak measurement system: an intra-tester reliability study.Manual Therapy. 2003; 8(3):176–9.CrossRefPubMed
28.
go back to reference Ha T-Ha, Saber-Sheikh Ka, Moore APa, Jones MPb. Measurement of lumbar spine range of movement and coupled motion using inertial sensors - a protocol validity study. Man Ther. 2013; 18(1):87–91.CrossRefPubMed Ha T-Ha, Saber-Sheikh Ka, Moore APa, Jones MPb. Measurement of lumbar spine range of movement and coupled motion using inertial sensors - a protocol validity study. Man Ther. 2013; 18(1):87–91.CrossRefPubMed
29.
go back to reference Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979; 86(2):420.CrossRefPubMed Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979; 86(2):420.CrossRefPubMed
30.
go back to reference Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1:307–10.CrossRefPubMed Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1:307–10.CrossRefPubMed
31.
go back to reference Kottner J, Audigé L, Brorson S, Donner A, Gajewski BJ, Hróbjartsson A, et al.Guidelines for reporting reliability and agreement studies (GRRAS) were proposed.J Clin Epidemiol. 2011; 64(1):96–106. doi:10.1016/j.jclinepi.2010.03.002.CrossRefPubMed Kottner J, Audigé L, Brorson S, Donner A, Gajewski BJ, Hróbjartsson A, et al.Guidelines for reporting reliability and agreement studies (GRRAS) were proposed.J Clin Epidemiol. 2011; 64(1):96–106. doi:10.1016/j.jclinepi.2010.03.002.CrossRefPubMed
32.
go back to reference Holden JP, Orsini JA, Siegel KL, Kepple TM, Gerber LH, Stanhope SJ. Surface movement errors in shank kinematics and knee kinetics during gait. Gait Posture. 1997; 5:217–7.CrossRef Holden JP, Orsini JA, Siegel KL, Kepple TM, Gerber LH, Stanhope SJ. Surface movement errors in shank kinematics and knee kinetics during gait. Gait Posture. 1997; 5:217–7.CrossRef
Metadata
Title
A technical support tool for joint range of motion determination in functional diagnostics - an inter-rater study
Authors
Christoph Schiefer
Thomas Kraus
Rolf P Ellegast
Elke Ochsmann
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Journal of Occupational Medicine and Toxicology / Issue 1/2015
Electronic ISSN: 1745-6673
DOI
https://doi.org/10.1186/s12995-015-0058-5

Other articles of this Issue 1/2015

Journal of Occupational Medicine and Toxicology 1/2015 Go to the issue