Skip to main content
Top
Published in: BMC Health Services Research 1/2016

Open Access 01-12-2016 | Research article

Availability and utilization of medical devices in Jimma zone hospitals, Southwest Ethiopia: a case study

Authors: Beyene Wondafrash Ademe, Bosena Tebeje, Ashagre Molla

Published in: BMC Health Services Research | Issue 1/2016

Login to get access

Abstract

Background

Health systems throughout the world, whether in developed or developing countries, are struggling with the challenge of how to manage health-care delivery in conditions of resource constraint. The availability and utilization of various health care equipments at all levels of the health care system has been emphasized for effective and efficient service delivery. In Ethiopia lack of proper management of medical equipment limited the capacity of health institutions to deliver adequate health care. The main objective of this study was to assess availability and utilization of medical devices and identify reported reasons that affect availability and utilization of medical devices among hospitals in Jimma Zone.

Methods

A cross-sectional multiple case-study using mixed quantitative and qualitative methods was used. Three hospitals of Jimma Zone were included in the study. Adapted and pre-tested structured English version checklist for availability and utilization of medical equipment and document review as well as interview guide for in-depth interview were used for data collection. Data were collected by observation of availability of the devices, interviewing selected professionals and document review of health care services using devices in the study hospitals. Data were analyzed using SPSS 16.0 statistical software. Descriptive analysis was made to determine the availability and functional status of medical devices. For qualitative part responses were transcribed, categorized and thematically analyzed.

Results

Observation and interview using checklist showed that 299 medical devices were available in the three hospitals among which, 196 (65.6 %) of them were available in Jimma University Specialized Hospital whereas, 57 (19.0 %) and 46 (15.4 %) were available in Limu Genet hospital and Shenen Gibe hospital respectively. Among 196 available medical devices in JUSH, 127 (64.8 %) were functional and the rest; 63 (32.1 %) and 6 (3.1 %) were not functional and not in use respectively. Similarly, 28 (60.9 %) and 30 (52.6 %) of the devices in Shenen Gibe hospital and LGH respectively were functional.

Conclusion

More than a third of medical devices in the three study hospitals were not functional. Purchasing devices with bids and preference for cheap price, lack of training on how to operate devices, less sense of accountability, power interruption, staff work overload and lack of maintenance experts, and inappropriate referral system were among the reported reasons for influencing availability and utilization of medical devices.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sinha SR, Michele B. Health Technologies and Innovation in the Global Health Arena. N Engl J Med. 2011;365(9):779.CrossRefPubMed Sinha SR, Michele B. Health Technologies and Innovation in the Global Health Arena. N Engl J Med. 2011;365(9):779.CrossRefPubMed
3.
go back to reference WHO, Medical Devices. Managing the Mismatch: An outcome of the priority medical devices project. 2010. WHO, Medical Devices. Managing the Mismatch: An outcome of the priority medical devices project. 2010.
4.
go back to reference De Chesnay M. Caring for the vulnerable: Perspectives in nursing theory practice and research. 3rd edition. Publisher Jones & Bartlett Learning; 2005. p. 292. De Chesnay M. Caring for the vulnerable: Perspectives in nursing theory practice and research. 3rd edition. Publisher Jones & Bartlett Learning; 2005. p. 292.
5.
go back to reference WHO. Medical device technical series, Health technology assessment of medical devices. 2011. WHO. Medical device technical series, Health technology assessment of medical devices. 2011.
6.
go back to reference Bryce C, Cline K. The supply and use of selected medical technologies. Health Aff. 1998;17:213–24.CrossRef Bryce C, Cline K. The supply and use of selected medical technologies. Health Aff. 1998;17:213–24.CrossRef
7.
go back to reference Ethiopian Standard Agency. Ethiopian standard; Comprehensive Specialized Hospital – Requirements. 1st ed. 2012. Ethiopian Standard Agency. Ethiopian standard; Comprehensive Specialized Hospital – Requirements. 1st ed. 2012.
8.
go back to reference Lleras-Muney A, Lichtenberg F. The effect of education on medical technology adoption: are the more educated more likely to use drugs. Cambridge: National Bureau of Economic Research; 2002.CrossRef Lleras-Muney A, Lichtenberg F. The effect of education on medical technology adoption: are the more educated more likely to use drugs. Cambridge: National Bureau of Economic Research; 2002.CrossRef
10.
go back to reference Robert M, Allison K. Evidence-based approach to the maintenance of laboratory and medical equipment in resource-poor settings. Med Biol Eng Comput. 2010;48(7):721-26. Springer. Robert M, Allison K. Evidence-based approach to the maintenance of laboratory and medical equipment in resource-poor settings. Med Biol Eng Comput. 2010;48(7):721-26. Springer.
11.
go back to reference Roderik FV. Aid alignment for global health research: the role of HIROs. Health Res Policy Syst. 2011;9(1):1. BioMed Central. Roderik FV. Aid alignment for global health research: the role of HIROs. Health Res Policy Syst. 2011;9(1):1. BioMed Central.
13.
go back to reference Zomboko FE, Tripathi SK, Kamuzora FK. Challenges in procurement and use of Donated medical-equipments: study of a selected referral hospital in Tanzania. J Arts Sci Commerce. 2012;III(4(1)):41. Zomboko FE, Tripathi SK, Kamuzora FK. Challenges in procurement and use of Donated medical-equipments: study of a selected referral hospital in Tanzania. J Arts Sci Commerce. 2012;III(4(1)):41.
14.
go back to reference Houngbo PT, G. J. v. d W, Medenou D, Dakpanon LY, Bunders J, Ruitenberg J. Policy and Management of Medical Devices for the Public Health Care Sector in Benin. 2012. p. 320. Houngbo PT, G. J. v. d W, Medenou D, Dakpanon LY, Bunders J, Ruitenberg J. Policy and Management of Medical Devices for the Public Health Care Sector in Benin. 2012. p. 320.
16.
go back to reference Federal Ministry of Health. Ethiopian Hospital Reform Implementation Guideline, vol. 2. 2010. Federal Ministry of Health. Ethiopian Hospital Reform Implementation Guideline, vol. 2. 2010.
17.
go back to reference Perry L, Malkin R. Effectiveness of medical equipment donations to improve health systems: how much medical equipment is broken in the developing world? Med Biol Eng Comput. 2011;49:719–22.CrossRefPubMed Perry L, Malkin R. Effectiveness of medical equipment donations to improve health systems: how much medical equipment is broken in the developing world? Med Biol Eng Comput. 2011;49:719–22.CrossRefPubMed
Metadata
Title
Availability and utilization of medical devices in Jimma zone hospitals, Southwest Ethiopia: a case study
Authors
Beyene Wondafrash Ademe
Bosena Tebeje
Ashagre Molla
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Health Services Research / Issue 1/2016
Electronic ISSN: 1472-6963
DOI
https://doi.org/10.1186/s12913-016-1523-2

Other articles of this Issue 1/2016

BMC Health Services Research 1/2016 Go to the issue