Skip to main content
Top
Published in: BMC Oral Health 1/2020

Open Access 01-12-2020 | Research article

Finite element analysis of archwire parameters and activation forces on the M/F ratio of vertical, L- and T-loops

Author: Yongqing Cai

Published in: BMC Oral Health | Issue 1/2020

Login to get access

Abstract

Background

The ability of a loop to generate a certain moment/force ratio (M/F ratio) can achieve the desired tooth movement in orthodontics. The present study aimed to investigate the effects of elastic modulus, cross-sectional dimensions, loop configuration geometry dimensions, and activation force on the generated M/F ratio of vertical, L- and T-loops.

Methods

A total of 120 three-dimensional loop models were constructed with the Solidworks 2017 software and used for simulating loop activation with the Abaqus 6.14 software. Six vertical loop variations, 9 L-loop variations, and 9 T-loop variations were evaluated. In each group, only one parameter was variable [loop height, ring radius, leg length, leg step distance, legs distance, upper length, different archwire materials (elastic modulus), cross-sectional dimension, and activation force].

Results

The simulation results of the displacement and von Mises stress of each loop were investigated. The maximum displacement in the height direction was recorded to calculate the M/F ratio. The quantitative change trends in the generated M/F ratio of the loops with respect to various variables were established.

Conclusions

Increasing the loop height can increase the M/F ratio of the loop. This increasing trend is, especially, much more significant in T-loops compared with vertical loops and L-loops. In vertical loops, increasing the ring radius is much more effective than increasing the loop height to increase the M/F ratio of the loop. Compared with SS, TMA archwire loops can generate a higher M/F ratio due to its lower elastic modulus. Loops with a small cross-sectional area and high activation force can generate a high M/F ratio. The introduction of a leg step to loops does not increase the M/F ratio of loops.
Literature
1.
go back to reference Tominaga J, Ozaki H, Chiang PG, Sumi M, Tanaka M, Koga Y, et al. Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics: A 3-dimensional finite element study. Am J Orthod Detofacial Orthop. 2014;146:166–74.CrossRef Tominaga J, Ozaki H, Chiang PG, Sumi M, Tanaka M, Koga Y, et al. Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics: A 3-dimensional finite element study. Am J Orthod Detofacial Orthop. 2014;146:166–74.CrossRef
2.
go back to reference Burrow SJ. Friction and resistance to sliding in orthodontics: a critical review. Am J Orthod Dentofac Orthop. 2009;135:442–7.CrossRef Burrow SJ. Friction and resistance to sliding in orthodontics: a critical review. Am J Orthod Dentofac Orthop. 2009;135:442–7.CrossRef
3.
go back to reference Sivakumar A, Valiathan A. An intra-arch retraction mechanics--a contemporary review. J Ind Orthod Soc. 2006;39:101–9..CrossRef Sivakumar A, Valiathan A. An intra-arch retraction mechanics--a contemporary review. J Ind Orthod Soc. 2006;39:101–9..CrossRef
4.
go back to reference Proffit WR. Closure of extraction space. In: Proffit WR, Fields HW, Sarver DM, editors. Contemporary orthodontics. 4th ed. St Louis: Mosby Elsevier; 2007. p. 592–601. Proffit WR. Closure of extraction space. In: Proffit WR, Fields HW, Sarver DM, editors. Contemporary orthodontics. 4th ed. St Louis: Mosby Elsevier; 2007. p. 592–601.
5.
go back to reference Nanda R, Ghosh J. Principles of biomechanics. In: Nanda R, editor. Biomechanics in clinical orthodontics. Philadelphia: Saunders; 1997. p. 6–8. Nanda R, Ghosh J. Principles of biomechanics. In: Nanda R, editor. Biomechanics in clinical orthodontics. Philadelphia: Saunders; 1997. p. 6–8.
6.
go back to reference Burstone CJ. The segmented arch approach to space closure. Am J Orthod. 1982;82:361–78.CrossRef Burstone CJ. The segmented arch approach to space closure. Am J Orthod. 1982;82:361–78.CrossRef
7.
go back to reference Proffit WR. Contemporary orthodontics. St Louis: Mosby Publishing; 1986. Proffit WR. Contemporary orthodontics. St Louis: Mosby Publishing; 1986.
8.
go back to reference Tanne K, Koenig HA, Burstone CJ. Moment to force ratios and the center of rotation. Am J Orthod Detofacial Orthop. 1988;94:426–31.CrossRef Tanne K, Koenig HA, Burstone CJ. Moment to force ratios and the center of rotation. Am J Orthod Detofacial Orthop. 1988;94:426–31.CrossRef
9.
go back to reference Gjessing P. Controlled retraction of maxillary incisors. Am J Orthod Dentofac Orthop. 1992;101:120–31.CrossRef Gjessing P. Controlled retraction of maxillary incisors. Am J Orthod Dentofac Orthop. 1992;101:120–31.CrossRef
10.
go back to reference Safavi MR, Geramy A, Khezri AK. M/F ratios of four different closing loops: 3D analysis using the finite element method (FEM). Aust Orthod J. 2006;22:121.PubMed Safavi MR, Geramy A, Khezri AK. M/F ratios of four different closing loops: 3D analysis using the finite element method (FEM). Aust Orthod J. 2006;22:121.PubMed
11.
go back to reference Chen J, Isikbay SC, Brizendine EJ. Quantification of three-dimensional orthodontic force systems of T-loop archwires. Angle Orthod. 2010;80:754–8.CrossRef Chen J, Isikbay SC, Brizendine EJ. Quantification of three-dimensional orthodontic force systems of T-loop archwires. Angle Orthod. 2010;80:754–8.CrossRef
12.
go back to reference Rose D, Quick A, Swain M, et al. Moment-to-force characteristics of preactivated nickel-titanium and titanium-molybdenum alloy symmetrical T-loops. Am J Orthod Detofacial Orthop. 2009;135:757–63.CrossRef Rose D, Quick A, Swain M, et al. Moment-to-force characteristics of preactivated nickel-titanium and titanium-molybdenum alloy symmetrical T-loops. Am J Orthod Detofacial Orthop. 2009;135:757–63.CrossRef
13.
go back to reference Ribeiro A, Martins L, Junior RS, White L, Martins R. Effects of height and overactivation on a composite nickel-titanium T-loop. J World Fed Orthod. 2017;6:120–6. Ribeiro A, Martins L, Junior RS, White L, Martins R. Effects of height and overactivation on a composite nickel-titanium T-loop. J World Fed Orthod. 2017;6:120–6.
14.
go back to reference Sumi M, Koga Y, Tominaga JY, et al. Innovative design of closing loops producing an optimal force system applicable in the 0.022-in bracket slot system. Am J Orthod Detofacial Orthop. 2016;150:968–78.CrossRef Sumi M, Koga Y, Tominaga JY, et al. Innovative design of closing loops producing an optimal force system applicable in the 0.022-in bracket slot system. Am J Orthod Detofacial Orthop. 2016;150:968–78.CrossRef
15.
go back to reference Techalertpaisarn P, Versluis A. How do mechanical responses at closing loop ends vary when loop position changes? A systematic analysis of vertical, T-, and L-loops. Oral Sci Int. 2013;10:58–64.CrossRef Techalertpaisarn P, Versluis A. How do mechanical responses at closing loop ends vary when loop position changes? A systematic analysis of vertical, T-, and L-loops. Oral Sci Int. 2013;10:58–64.CrossRef
16.
go back to reference Techalertpaisarn P, Versluis A, Versluis B. Mechanical properties of opus closing loops, L-loops, and T-loops investigated with finite element analysis. Am J Orthod Detofacial Orthop. 2013;143:675–83.CrossRef Techalertpaisarn P, Versluis A, Versluis B. Mechanical properties of opus closing loops, L-loops, and T-loops investigated with finite element analysis. Am J Orthod Detofacial Orthop. 2013;143:675–83.CrossRef
17.
go back to reference Techalertpaisarn P, Versluis A. Effect of apical portion of T-, sloped L-, and reversed L-closing loops on their force systems. Angle Orthod. 2016;87:104.CrossRef Techalertpaisarn P, Versluis A. Effect of apical portion of T-, sloped L-, and reversed L-closing loops on their force systems. Angle Orthod. 2016;87:104.CrossRef
18.
go back to reference Burstone CJ, Koenig HA. Optimizing anterior and canine retraction. Am J Orthod. 1976;70:1–19.CrossRef Burstone CJ, Koenig HA. Optimizing anterior and canine retraction. Am J Orthod. 1976;70:1–19.CrossRef
19.
go back to reference Techalertpaisarn P, Versluis A. T-loop force system with and without vertical step using finite element analysis. Angle Orthod. 2016;86:372–9.CrossRef Techalertpaisarn P, Versluis A. T-loop force system with and without vertical step using finite element analysis. Angle Orthod. 2016;86:372–9.CrossRef
20.
go back to reference Chacko A, Tikku T, Khanna R, et al. Comparative assessment of the efficacy of closed helical loop and T-loop for space closure in lingual orthodontics-a finite element study. Prog Orthod. 2018;19:14.CrossRef Chacko A, Tikku T, Khanna R, et al. Comparative assessment of the efficacy of closed helical loop and T-loop for space closure in lingual orthodontics-a finite element study. Prog Orthod. 2018;19:14.CrossRef
21.
go back to reference Kojima Y, Fukui H. Numerical simulations of canine retraction with T-loop springs based on the updated moment-to-force ratio. Europ J Orthod. 2012;34:10.CrossRef Kojima Y, Fukui H. Numerical simulations of canine retraction with T-loop springs based on the updated moment-to-force ratio. Europ J Orthod. 2012;34:10.CrossRef
22.
go back to reference Haris TPM, Francis PG, Margaret VA, Roshan G, Menon V, Jojee V. Evaluation of biomechanical properties of four loops at different activation: a finite element method study. J Contemp Dent Pract. 2018;19:778–84.CrossRef Haris TPM, Francis PG, Margaret VA, Roshan G, Menon V, Jojee V. Evaluation of biomechanical properties of four loops at different activation: a finite element method study. J Contemp Dent Pract. 2018;19:778–84.CrossRef
23.
go back to reference Geramy A, Tanne K, Moradi M, et al. Finite element analysis of the convergence of the centers of resistance and rotation in extreme moment-to-force ratios[J]. Int Orthod. 2016;14:161–70.PubMed Geramy A, Tanne K, Moradi M, et al. Finite element analysis of the convergence of the centers of resistance and rotation in extreme moment-to-force ratios[J]. Int Orthod. 2016;14:161–70.PubMed
24.
go back to reference Almeida L, Ribeiro A, Parsekian Martins R, et al. Nickel titanium T-loop wire dimensions for en masse retraction. Angle Orthod. 2016:070515–449.1. Almeida L, Ribeiro A, Parsekian Martins R, et al. Nickel titanium T-loop wire dimensions for en masse retraction. Angle Orthod. 2016:070515–449.1.
25.
go back to reference Jiang F, Chen J, Kula K, et al. Root resorptions associated with canine retraction treatment. Am J Orthod Detofacial Orthop. 2017;152:348–54.CrossRef Jiang F, Chen J, Kula K, et al. Root resorptions associated with canine retraction treatment. Am J Orthod Detofacial Orthop. 2017;152:348–54.CrossRef
26.
go back to reference Martins RP, Buschang PH, Martins LP, Gandini LG Jr. Optimizing the design of preactivated titanium T-loop springs with loop software. Am J Orthod Dentofac Orthop. 2008;134:161–6.CrossRef Martins RP, Buschang PH, Martins LP, Gandini LG Jr. Optimizing the design of preactivated titanium T-loop springs with loop software. Am J Orthod Dentofac Orthop. 2008;134:161–6.CrossRef
27.
go back to reference Muñoz-Rendón WA, Montoya-Goez Y-d-J, Gómez-Gil DF. M/F Changes after T-loop Upper Horizontal Bending in Segmented Arch Mechanics. Int J Odontostomatology. 2016;10:333–41.CrossRef Muñoz-Rendón WA, Montoya-Goez Y-d-J, Gómez-Gil DF. M/F Changes after T-loop Upper Horizontal Bending in Segmented Arch Mechanics. Int J Odontostomatology. 2016;10:333–41.CrossRef
28.
go back to reference Faulkner MG, Fuchshuber P, Haberstock D, Mioduchowski A. A parametric study of the force/moment systems produced by T-loop retraction springs. J Biomech. 1989;22:637–47.CrossRef Faulkner MG, Fuchshuber P, Haberstock D, Mioduchowski A. A parametric study of the force/moment systems produced by T-loop retraction springs. J Biomech. 1989;22:637–47.CrossRef
29.
go back to reference Nicolai RJ. On optimum orthodontic force theory as applied to canine retraction. Am J Orthod. 1975;68:290–302.CrossRef Nicolai RJ. On optimum orthodontic force theory as applied to canine retraction. Am J Orthod. 1975;68:290–302.CrossRef
30.
go back to reference Gjessing P. Biomechanical design and clinical evaluation of a new canine-retraction spring. Am J Orthod. 1985;87:353–62.CrossRef Gjessing P. Biomechanical design and clinical evaluation of a new canine-retraction spring. Am J Orthod. 1985;87:353–62.CrossRef
Metadata
Title
Finite element analysis of archwire parameters and activation forces on the M/F ratio of vertical, L- and T-loops
Author
Yongqing Cai
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2020
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-020-1059-z

Other articles of this Issue 1/2020

BMC Oral Health 1/2020 Go to the issue