Skip to main content
Top
Published in: BMC Oral Health 1/2020

Open Access 01-12-2020 | Research article

Marginal bone resorption of posterior mandible dental implants with different insertion methods

Authors: Ehsan Aliabadi, Saeid Tavanafar, Mohammad Saleh Khaghaninejad

Published in: BMC Oral Health | Issue 1/2020

Login to get access

Abstract

Background

To evaluated the marginal bone loss around dental implants by two insertion methods.

Methods

Eligible patients were divided into two groups; manual and mechanized groups. Peri-apical x-ray using a customized device to standardize the radiographs designed and used to take three periodical radiographs; after surgery, three months, and six months follow up. An independent t-test was used to compare the two groups regarding the average level of marginal bone loss (p < 0.05).

Results

After excluding dropouts, a total of 273 patients (120 males and 153 females, aged between 25 and 67 years old) were included in the study. The average marginal bone loss in the manual insertion method was 0.44 ± 0.84 mm, and 0.59 ± 0.20 mm, and for the mechanized method was 0.51 ± 0.20 mm and 0.67 ± 0.19 mm after three and six months, respectively. There was a significant difference in marginal bone loss after six months between the two groups(p < 0.001). However, no differences were observed after three months (p = 0.24).

Conclusions

Under the condition of this study, both techniques were safe and resulted in an acceptable amount of bone resorption; however, in the manual method, the less marginal bone loss occurred after six months.
Literature
1.
go back to reference Cardaropoli G, Araújo M, Lindhe J. Dynamics of bone tissue formation in tooth extraction sites: an experimental study in dogs. J Clin Periodontol. 2003;30:809–18.CrossRef Cardaropoli G, Araújo M, Lindhe J. Dynamics of bone tissue formation in tooth extraction sites: an experimental study in dogs. J Clin Periodontol. 2003;30:809–18.CrossRef
2.
go back to reference Engquist B, Åstrand P, Anzén B, Dahlgren S, Engquist E, Feldmann H, et al. Simplified methods of implant treatment in the edentulous lower jaw: a 3-year follow-up report of a controlled prospective study of one-stage versus two-stage surgery and early loading. Clin Implant Dent Relat Res. 2005;7:95–104.CrossRef Engquist B, Åstrand P, Anzén B, Dahlgren S, Engquist E, Feldmann H, et al. Simplified methods of implant treatment in the edentulous lower jaw: a 3-year follow-up report of a controlled prospective study of one-stage versus two-stage surgery and early loading. Clin Implant Dent Relat Res. 2005;7:95–104.CrossRef
3.
go back to reference Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent. 1988;60:75–84.CrossRef Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent. 1988;60:75–84.CrossRef
4.
go back to reference Bilhan H, Geckili O, Mumcu E, Bozdag E, Sünbüloǧlu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil. 2010;37:900–7.CrossRef Bilhan H, Geckili O, Mumcu E, Bozdag E, Sünbüloǧlu E, Kutay O. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone. J Oral Rehabil. 2010;37:900–7.CrossRef
5.
go back to reference Lachmann S, Laval JY, Axmann D, Weber H. Influence of implant geometry on primary insertion stability and simulated peri-implant bone loss: an in vitro study using resonance frequency analysis and damping capacity assessment. Int J Oral Maxillofac Implants. 2011;26:347–55. Lachmann S, Laval JY, Axmann D, Weber H. Influence of implant geometry on primary insertion stability and simulated peri-implant bone loss: an in vitro study using resonance frequency analysis and damping capacity assessment. Int J Oral Maxillofac Implants. 2011;26:347–55.
6.
go back to reference Möhlhenrich SC, Modabber A, Steiner T, Mitchell DA, Hölzle F. Heat generation and drill wear during dental implant site preparation: systematic review. Br J Oral Maxillofac Surg. 2015;53:679–89.CrossRef Möhlhenrich SC, Modabber A, Steiner T, Mitchell DA, Hölzle F. Heat generation and drill wear during dental implant site preparation: systematic review. Br J Oral Maxillofac Surg. 2015;53:679–89.CrossRef
7.
go back to reference Karmani S. The thermal properties of bone and the effects of surgical intervention. Curr Orthop. 2006;20:52–8.CrossRef Karmani S. The thermal properties of bone and the effects of surgical intervention. Curr Orthop. 2006;20:52–8.CrossRef
8.
go back to reference Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants. 1994;9:149–55.PubMed Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants. 1994;9:149–55.PubMed
9.
go back to reference Misch C. Contemporary implant dentistry-E-book. St Loius: Elsevier Health Sciences; 2007. Misch C. Contemporary implant dentistry-E-book. St Loius: Elsevier Health Sciences; 2007.
10.
go back to reference García-Vives N, Andrés-García R, Rios-Santos V, Fernández-Palacín A, Bullón-Fernández P, Herrero-Climent M, et al. In vitro evaluation of the type of implant bed preparation with osteotomes in bone type IV and its influence on the stability of two implant systems. Med Oral Patol Oral Cir Bucal. 2009;14:e455–60.PubMed García-Vives N, Andrés-García R, Rios-Santos V, Fernández-Palacín A, Bullón-Fernández P, Herrero-Climent M, et al. In vitro evaluation of the type of implant bed preparation with osteotomes in bone type IV and its influence on the stability of two implant systems. Med Oral Patol Oral Cir Bucal. 2009;14:e455–60.PubMed
11.
go back to reference Hupp J, Tucker M, Ellis E. Contemporary Oral and maxillofacial surgery-E-book. 6th ed. St Loius: Mosby; 2018. Hupp J, Tucker M, Ellis E. Contemporary Oral and maxillofacial surgery-E-book. 6th ed. St Loius: Mosby; 2018.
12.
go back to reference Vallee MC, Conrad HJ, Basu S, Seong WJ. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants. J Prosthet Dent. 2008;100:86–92.CrossRef Vallee MC, Conrad HJ, Basu S, Seong WJ. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants. J Prosthet Dent. 2008;100:86–92.CrossRef
13.
go back to reference Misch CE, Qu Z, Bidez MW. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg. 1999;57:700–6 discussion 706-8.CrossRef Misch CE, Qu Z, Bidez MW. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg. 1999;57:700–6 discussion 706-8.CrossRef
14.
go back to reference Ottoni JMP, Oliveira ZFL, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants. 2005;20:769–76.PubMed Ottoni JMP, Oliveira ZFL, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants. 2005;20:769–76.PubMed
15.
go back to reference Kanawati A, Richards MW, Becker JJ, Monaco NE. Measurement of clinicians’ ability to hand torque dental implant components. J Oral Implantol. 2009;35:185–8.CrossRef Kanawati A, Richards MW, Becker JJ, Monaco NE. Measurement of clinicians’ ability to hand torque dental implant components. J Oral Implantol. 2009;35:185–8.CrossRef
16.
go back to reference Mahshid M, Saboury A, Fayaz A, Sadr SJ, Lampert F, Mir M. The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants. Clin Cosmet Investig Dent. 2012;4:29–35.CrossRef Mahshid M, Saboury A, Fayaz A, Sadr SJ, Lampert F, Mir M. The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants. Clin Cosmet Investig Dent. 2012;4:29–35.CrossRef
17.
go back to reference Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992;7:353–9.PubMed Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992;7:353–9.PubMed
18.
go back to reference McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin N Am. 1998;42:71–89.PubMed McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin N Am. 1998;42:71–89.PubMed
19.
go back to reference Lang NP, Zitzmann NU. Working Group 3 of the VIII European Workshop on Periodontology. Clinical research in implant dentistry: evaluation of implant-supported restorations, aesthetic and patient-reported outcomes. J Clin Periodontol. 2012;39(Suppl 1):133–8.CrossRef Lang NP, Zitzmann NU. Working Group 3 of the VIII European Workshop on Periodontology. Clinical research in implant dentistry: evaluation of implant-supported restorations, aesthetic and patient-reported outcomes. J Clin Periodontol. 2012;39(Suppl 1):133–8.CrossRef
20.
go back to reference Nisapakultorn K, Suphanantachat S, Silkosessak O, Rattanamongkolgul S. Factors affecting soft tissue level around anterior maxillary single-tooth implants. Clin Oral Implants Res. 2010;21:662–70.CrossRef Nisapakultorn K, Suphanantachat S, Silkosessak O, Rattanamongkolgul S. Factors affecting soft tissue level around anterior maxillary single-tooth implants. Clin Oral Implants Res. 2010;21:662–70.CrossRef
21.
go back to reference Albrektsson T, Albrektsson B. Osseointegration of bone implants. A review of an alternative mode of fixation. Acta Orthop Scand. 1987;58:567–77.CrossRef Albrektsson T, Albrektsson B. Osseointegration of bone implants. A review of an alternative mode of fixation. Acta Orthop Scand. 1987;58:567–77.CrossRef
22.
go back to reference Cehreli MC, Akça K, Tönük E. Accuracy of a manual torque application device for Morse-taper implants: a technical note. Int J Oral Maxillofac Implants. 2004;19:743–8. Cehreli MC, Akça K, Tönük E. Accuracy of a manual torque application device for Morse-taper implants: a technical note. Int J Oral Maxillofac Implants. 2004;19:743–8.
23.
go back to reference Roos J, Sennerby L, Lekholm U, Jemt T, Gröndahl K, Albrektsson T. A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant. Int J Oral Maxillofac Implants. 1997;12:504–14.PubMed Roos J, Sennerby L, Lekholm U, Jemt T, Gröndahl K, Albrektsson T. A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant. Int J Oral Maxillofac Implants. 1997;12:504–14.PubMed
24.
go back to reference Zarb GA, Albrektsson T. Consensus report: towards optimized treatment outcomes for dental implants. J Prosthet Dent. 1998;80:641.CrossRef Zarb GA, Albrektsson T. Consensus report: towards optimized treatment outcomes for dental implants. J Prosthet Dent. 1998;80:641.CrossRef
25.
go back to reference Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986;1:11–25.PubMed Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986;1:11–25.PubMed
26.
go back to reference Goodson JM, Haffajee AD, Socransky SS. The relationship between attachment level loss and alveolar bone loss. J Clin Periodontol. 1984;11:348–59.CrossRef Goodson JM, Haffajee AD, Socransky SS. The relationship between attachment level loss and alveolar bone loss. J Clin Periodontol. 1984;11:348–59.CrossRef
27.
go back to reference Newman MG, Takei HH, Klokkevold PR, Carranza FA. Carranza’s clinical periodontology. St. Louis: Saunders Elsevier; 2012.CrossRef Newman MG, Takei HH, Klokkevold PR, Carranza FA. Carranza’s clinical periodontology. St. Louis: Saunders Elsevier; 2012.CrossRef
29.
go back to reference Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg Am. 1972;54:297–308.CrossRef Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg Am. 1972;54:297–308.CrossRef
30.
go back to reference Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10:387–416.CrossRef Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10:387–416.CrossRef
31.
go back to reference Wikenheiser MA, Markel MD, Lewallen DG, Chao EY. Thermal response and torque resistance of five cortical half-pins under simulated insertion technique. J Orthop Res. 1995;13:615–9.CrossRef Wikenheiser MA, Markel MD, Lewallen DG, Chao EY. Thermal response and torque resistance of five cortical half-pins under simulated insertion technique. J Orthop Res. 1995;13:615–9.CrossRef
32.
go back to reference Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol. 2002;29:197–212.CrossRef Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol. 2002;29:197–212.CrossRef
33.
go back to reference Novsak D, Zrinski MT, Spalj S. Machine-Driven Versus Manual Insertion Mode. Implant Dent. 2014;24:1.CrossRef Novsak D, Zrinski MT, Spalj S. Machine-Driven Versus Manual Insertion Mode. Implant Dent. 2014;24:1.CrossRef
Metadata
Title
Marginal bone resorption of posterior mandible dental implants with different insertion methods
Authors
Ehsan Aliabadi
Saeid Tavanafar
Mohammad Saleh Khaghaninejad
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2020
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-020-1019-7

Other articles of this Issue 1/2020

BMC Oral Health 1/2020 Go to the issue