Abstract

Background

Mock-up based approach allows the preview of the aesthetic rehabilitation, however, it is crucial that the mock-up does not differ from the expected aesthetic outcomes. With CAD-CAM technologies, it is possible to directly create mock-ups from virtual planned smile project, with greater accuracy and efficiency compared to the conventional moulded mock-ups. In this study, we investigated the trueness of mock-ups obtained with milling and 3D printing technology and a full digital work-flow system.

Methods

Ten adults subjects were included and digital smile design/digital wax-up were performed to enhance the aesthetic of maxillary anterior region. Ten milled mock-ups and 10 prototyped mock-ups were obtained from the original .stl file and a digital analysis of trueness was carried out by superimposing the scanned-milled mock-ups and the scanned-prototyped mock-ups to the digital wax-up, according to the surface-to-surface matching technique. Specific linear measurements were performed to investigate and compare the dimensional characteristics of the physical manufactures, the 3D project and the scanned mock-ups. All data were statistically analyzed. A clinical test was also performed to assess the fitting of the final manufacture.

Results

The prototyped mock-ups showed a significant increment of the transversal measurements (p < 0.001) while the milled mock-ups showed a significant increment of all vertical and transversal measurements (p < 0.001). The prototyped mock-ups showed good fitting after clinical tests while none of the milled mock-ups showed good adaptation (no fitting or significant clinical compensation required). Deviation analysis from the original 3D project reported a greater matching percentage for the scanned-milled mock-ups (80,31% ± 2.50) compared to the scanned-prototyped mock-ups (69,17% ± 2.64) (p < 0.001). This was in contrast with the findings from linear measurements as well as from the clinical test and may have been affected by a reductive algorithmic computation after digitization of physical mock-ups.

Conclusion

Both prototype and milled mock-ups showed a slight dimensional increment comparing to the original 3D project, with milled-mock-ups showing less fitting after clinical tests. Caution must be taken when assessing the trueness of scanned manufacture since an intrinsic error in the system can underestimate the dimensions of the real object.
Literature
1.
go back to reference Mazilu Moldovan A, Sarosi C, Moldovan M, Miuta F, Prodan D, Antoniac A, Prejmerean C, Silaghi Dumitrescu L, Popescu V, Raiciu AD, Saceleanu V. Preparation and Characterization of Natural Bleaching Gels Used in Cosmetic Dentistry. Materials (Basel). 2019;12(13). Mazilu Moldovan A, Sarosi C, Moldovan M, Miuta F, Prodan D, Antoniac A, Prejmerean C, Silaghi Dumitrescu L, Popescu V, Raiciu AD, Saceleanu V. Preparation and Characterization of Natural Bleaching Gels Used in Cosmetic Dentistry. Materials (Basel). 2019;12(13).
2.
go back to reference Gresnigt MMM, Cune MS, Jansen K, van der Made SAM, Özcan M. Randomized clinical trial on indirect resin composite and ceramic laminate veneers: Up to 10-year findings. J Dent. 2019;86:102–9. Gresnigt MMM, Cune MS, Jansen K, van der Made SAM, Özcan M. Randomized clinical trial on indirect resin composite and ceramic laminate veneers: Up to 10-year findings. J Dent. 2019;86:102–9.
3.
go back to reference Gürel G. Predictable, precise, and repeatable tooth preparation for porcelain laminate veneers. Pract Proced Aesthet Dent. 2003;15(1):17–24.PubMed Gürel G. Predictable, precise, and repeatable tooth preparation for porcelain laminate veneers. Pract Proced Aesthet Dent. 2003;15(1):17–24.PubMed
4.
go back to reference Land MF, Hopp CD. Survival rates of all-ceramic systems differ by clinical indication and fabrication method. J Evid Based Dent Pract. 2010;10(1):37–8.CrossRef Land MF, Hopp CD. Survival rates of all-ceramic systems differ by clinical indication and fabrication method. J Evid Based Dent Pract. 2010;10(1):37–8.CrossRef
5.
go back to reference Simon H, Magne P. Clinically based diagnostic wax-up for optimal esthetics: the diagnostic mock-up. J Calif Dent Assoc. 2008;36:355–62.PubMed Simon H, Magne P. Clinically based diagnostic wax-up for optimal esthetics: the diagnostic mock-up. J Calif Dent Assoc. 2008;36:355–62.PubMed
6.
go back to reference Magne P, Magne M, Belser U. The diagnostic template: a key element to the comprehensive esthetic treatment concept. Int J Periodontics Restorative Dent. 1996;16:560–9.PubMed Magne P, Magne M, Belser U. The diagnostic template: a key element to the comprehensive esthetic treatment concept. Int J Periodontics Restorative Dent. 1996;16:560–9.PubMed
7.
go back to reference Gurrea J, Bruguera A. Wax-up and mock-up. A guide for anterior periodontal and restorative treatments. Int J Esthet Dent. 2014;9:146–62.PubMed Gurrea J, Bruguera A. Wax-up and mock-up. A guide for anterior periodontal and restorative treatments. Int J Esthet Dent. 2014;9:146–62.PubMed
8.
go back to reference Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1955;34(6):849–53.CrossRef Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1955;34(6):849–53.CrossRef
9.
go back to reference Granell-Ruiz M, Fons-Font A, Labaig-Rueda C, Martinez-Gonzalez A. Roman- Rodriguez JL, Solà-Ruiz MF. A clinical longitudinal study 323 porcelain laminate veneers. Period study from 3 to 11 years. Med Oral Patol Oral Cir Bucal. 2010;15(3):531–7.CrossRef Granell-Ruiz M, Fons-Font A, Labaig-Rueda C, Martinez-Gonzalez A. Roman- Rodriguez JL, Solà-Ruiz MF. A clinical longitudinal study 323 porcelain laminate veneers. Period study from 3 to 11 years. Med Oral Patol Oral Cir Bucal. 2010;15(3):531–7.CrossRef
10.
go back to reference Gurel G. Porcelain laminate veneers: minimal tooth preparation by design. Dent Clin N Am. 2007;51(2):419–31.CrossRef Gurel G. Porcelain laminate veneers: minimal tooth preparation by design. Dent Clin N Am. 2007;51(2):419–31.CrossRef
11.
go back to reference Magne P. A new approach to the learning of dental morphology, function, and esthetics: the "2D-3D-4D" concept. Int J Esthet Dent. 2015;10(1):32–47.PubMed Magne P. A new approach to the learning of dental morphology, function, and esthetics: the "2D-3D-4D" concept. Int J Esthet Dent. 2015;10(1):32–47.PubMed
12.
go back to reference Zimmermann M, Mehl A. Virtual smile design systems: a current review. Int J Comput Dent. 2015;18(4):303–17.PubMed Zimmermann M, Mehl A. Virtual smile design systems: a current review. Int J Comput Dent. 2015;18(4):303–17.PubMed
13.
go back to reference Morimoto S, Albanesi RB, Sesma N, Agra CM, Braga MM. Main clinical outcomes of feldspathic porcelain and glass-ceramic laminate veneers: a systematic review and meta-analysis of survival and complication rates. Int J Prosthodont. 2016;29:38–49.CrossRef Morimoto S, Albanesi RB, Sesma N, Agra CM, Braga MM. Main clinical outcomes of feldspathic porcelain and glass-ceramic laminate veneers: a systematic review and meta-analysis of survival and complication rates. Int J Prosthodont. 2016;29:38–49.CrossRef
14.
go back to reference Jang YS, Oh SH, Oh WS, Lee MH, Lee JJ, Bae TS. Effects of Liner-Bonding of Implant-Supported Glass-Ceramic Crown to Zirconia Abutment on Bond Strength and Fracture Resistance. Materials (Basel). 2019;12(17). Jang YS, Oh SH, Oh WS, Lee MH, Lee JJ, Bae TS. Effects of Liner-Bonding of Implant-Supported Glass-Ceramic Crown to Zirconia Abutment on Bond Strength and Fracture Resistance. Materials (Basel). 2019;12(17).
15.
go back to reference Venturini AB, Prochnow C, Pereira GKR, Segala RD, Kleverlaan CJ, Valandro LF. Fatigue performance of adhesively cemented glass-, hybrid- and resin-ceramic materials for CAD/CAM monolithic restorations. Dent Mater. 2019;35(4):534–42.CrossRef Venturini AB, Prochnow C, Pereira GKR, Segala RD, Kleverlaan CJ, Valandro LF. Fatigue performance of adhesively cemented glass-, hybrid- and resin-ceramic materials for CAD/CAM monolithic restorations. Dent Mater. 2019;35(4):534–42.CrossRef
16.
go back to reference Cattoni F, Teté G, Calloni AM, Manazza F, Gastaldi G, Capparè P. Milled versus moulded mock-ups based on the superimposition of 3D meshes from digital oral impressions: a comparative in vitro study in the aesthetic area. BMC Oral Health. 2019;19(1):230.CrossRef Cattoni F, Teté G, Calloni AM, Manazza F, Gastaldi G, Capparè P. Milled versus moulded mock-ups based on the superimposition of 3D meshes from digital oral impressions: a comparative in vitro study in the aesthetic area. BMC Oral Health. 2019;19(1):230.CrossRef
17.
go back to reference Camardella LT, de Vasconcellos VO, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthod Dentofac Orthop. 2017;151:1178–87.CrossRef Camardella LT, de Vasconcellos VO, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthod Dentofac Orthop. 2017;151:1178–87.CrossRef
18.
go back to reference Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofac Orthop. 2018;153:144–53.CrossRef Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofac Orthop. 2018;153:144–53.CrossRef
19.
go back to reference Park ME, Shin SY. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. J Prosthet Dent. 2018;119:e1–e861.CrossRef Park ME, Shin SY. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. J Prosthet Dent. 2018;119:e1–e861.CrossRef
20.
go back to reference Kim SY, Lee SH, Cho SK, Jeong CM, Jeon YC, Yun MJ, Huh JB. Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model. J Adv Prosthodont. 2014;6:1–7.CrossRef Kim SY, Lee SH, Cho SK, Jeong CM, Jeon YC, Yun MJ, Huh JB. Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model. J Adv Prosthodont. 2014;6:1–7.CrossRef
21.
go back to reference Imam H, Gram M, Benetti AR, Gotfredsen K. Accuracy of stereolithography additive casts used in a digital workflow. J Prosthet Dent. 2018;119:580–5.CrossRef Imam H, Gram M, Benetti AR, Gotfredsen K. Accuracy of stereolithography additive casts used in a digital workflow. J Prosthet Dent. 2018;119:580–5.CrossRef
22.
go back to reference Koch GK, Gallucci GO, Lee SJ. Accuracy in the digital workflow: from data acquisition to the digitally milled cast. J Prosthet Dent. 2016;115:749–54.CrossRef Koch GK, Gallucci GO, Lee SJ. Accuracy in the digital workflow: from data acquisition to the digitally milled cast. J Prosthet Dent. 2016;115:749–54.CrossRef
23.
go back to reference Leonardi R, Lo Giudice A, Rugeri M, Muraglie S, Cordasco G, Barbato E. Three-dimensional evaluation on digital casts of maxillary palatal size and morphology in patients with functional posterior crossbite. Eur J Orthod. 2018;40(5):556–62.CrossRef Leonardi R, Lo Giudice A, Rugeri M, Muraglie S, Cordasco G, Barbato E. Three-dimensional evaluation on digital casts of maxillary palatal size and morphology in patients with functional posterior crossbite. Eur J Orthod. 2018;40(5):556–62.CrossRef
24.
go back to reference Leonardi R, Muraglie S, Lo Giudice A, Aboulazm KS, Nucera R. Evaluation of mandibular symmetry and morphology in adult patients with unilateral posterior crossbite: a CBCT study using a surface-to-surface matching technique. Eur J Orthod. 2020. https://doi.org/10.1093/ejo/cjz106. Leonardi R, Muraglie S, Lo Giudice A, Aboulazm KS, Nucera R. Evaluation of mandibular symmetry and morphology in adult patients with unilateral posterior crossbite: a CBCT study using a surface-to-surface matching technique. Eur J Orthod. 2020. https://​doi.​org/​10.​1093/​ejo/​cjz106.
25.
go back to reference Isola G, Polizzi A, Muraglie S, Leonardi RM, Lo Giudice A. Assessment Of vitamin C And Antioxidants Profiles In Saliva And Serum In Patients With Periodontitis And Ischemic Heart Disease. Nutrients. 2019;11(12). https://doi.org/10.3390/nu11122956. Isola G, Polizzi A, Muraglie S, Leonardi RM, Lo Giudice A. Assessment Of vitamin C And Antioxidants Profiles In Saliva And Serum In Patients With Periodontitis And Ischemic Heart Disease. Nutrients. 2019;11(12). https://​doi.​org/​10.​3390/​nu11122956.
26.
go back to reference Lo Giudice A, Nucera R, Ronsivalle V, Di Grazia C, Rugeri M, Quinzi V. Enhance the diagnosis of maxillary transverse discrepancy through 3-D technology and surface to surface superimposition. A description of the digital work flow with documented case report. Eur J Paed Dent. in press. Lo Giudice A, Nucera R, Ronsivalle V, Di Grazia C, Rugeri M, Quinzi V. Enhance the diagnosis of maxillary transverse discrepancy through 3-D technology and surface to surface superimposition. A description of the digital work flow with documented case report. Eur J Paed Dent. in press.
27.
go back to reference Sanchez-Lara A, Chochlidakis KM, Lampraki E, Molinelli R, Molinelli F. Ercoli C comprehensive digital approach with the digital smile system: a clinical report. J Prosthet Dent. 2019;121(6):871–5.CrossRef Sanchez-Lara A, Chochlidakis KM, Lampraki E, Molinelli R, Molinelli F. Ercoli C comprehensive digital approach with the digital smile system: a clinical report. J Prosthet Dent. 2019;121(6):871–5.CrossRef
28.
go back to reference Isa ZM, Tawfiq OF, Noor NM, Shamsudheen MI, Rijal OM. Regression methods to investigate the relationship between facial measurements and widths of the maxillary anterior teeth. J Prosthet Dent. 2010;103(3):182–8.CrossRef Isa ZM, Tawfiq OF, Noor NM, Shamsudheen MI, Rijal OM. Regression methods to investigate the relationship between facial measurements and widths of the maxillary anterior teeth. J Prosthet Dent. 2010;103(3):182–8.CrossRef
29.
go back to reference Gurel G, Morimoto S, Calamita MA, Coachman C, Sesma N. Clinical performance of porcelain laminate veneers: outcomes of the aesthetic pre-evaluative temporary (APT) technique. Int J Periodontics Restorative Dent. 2012;32(6):625–35.PubMed Gurel G, Morimoto S, Calamita MA, Coachman C, Sesma N. Clinical performance of porcelain laminate veneers: outcomes of the aesthetic pre-evaluative temporary (APT) technique. Int J Periodontics Restorative Dent. 2012;32(6):625–35.PubMed
30.
go back to reference Gherlone EF, Capparé P, Vinci R, Ferrini F, Gastaldi G, Crespi R. Conventionalversus digital impressions for all-on-four restorations. Int J Oral Maxillofac Implants. 2016;31(2):324–30.CrossRef Gherlone EF, Capparé P, Vinci R, Ferrini F, Gastaldi G, Crespi R. Conventionalversus digital impressions for all-on-four restorations. Int J Oral Maxillofac Implants. 2016;31(2):324–30.CrossRef
31.
go back to reference Nucera R, Lo Giudice A, Bellocchio M, Spinuzza P, Caprioglio A, Cordasco G. Diagnostic concordance between skeletal cephalometrics, radiograph-based soft-tissue cephalometrics, and photograph-based soft-tissue cephalometrics. Eur J Orthod. 2017;39(4):352–7.PubMed Nucera R, Lo Giudice A, Bellocchio M, Spinuzza P, Caprioglio A, Cordasco G. Diagnostic concordance between skeletal cephalometrics, radiograph-based soft-tissue cephalometrics, and photograph-based soft-tissue cephalometrics. Eur J Orthod. 2017;39(4):352–7.PubMed
32.
go back to reference Ercus S, Chung E, McLaren E. Esthetics with minimal tooth preparation achieved through a digital approach. Compend Contin Educ Dent. 2013;34(6):428–31.PubMed Ercus S, Chung E, McLaren E. Esthetics with minimal tooth preparation achieved through a digital approach. Compend Contin Educ Dent. 2013;34(6):428–31.PubMed
33.
go back to reference Reshad M, Cascione D, Magne P. Diagnostic mock-ups as an objective tool for predictamble outcomes with porcelain laminate veneers in esthetically demanding patients: a clinical report. J Prosthet Dent. 2008;99(5):333–9.CrossRef Reshad M, Cascione D, Magne P. Diagnostic mock-ups as an objective tool for predictamble outcomes with porcelain laminate veneers in esthetically demanding patients: a clinical report. J Prosthet Dent. 2008;99(5):333–9.CrossRef
35.
go back to reference Verma RJ, Singh SP, Verma S, Kumar V, Bhupali NR, Arora S. Comparison of reliability, validity, and accuracy of linear measurements made on pre- and posttreatment digital study models with conventional plaster study models. J Orthod Sci. 2019;8:18. Verma RJ, Singh SP, Verma S, Kumar V, Bhupali NR, Arora S. Comparison of reliability, validity, and accuracy of linear measurements made on pre- and posttreatment digital study models with conventional plaster study models. J Orthod Sci. 2019;8:18.
36.
go back to reference Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop. 2003;124:101–5.CrossRef Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop. 2003;124:101–5.CrossRef
37.
go back to reference Joós-Kovács G, Vecsei B, Körmendi S, Gyarmathy VA, Borbély J, Hermann P. Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study. BMC Oral Health. 2019;19(1):280.CrossRef Joós-Kovács G, Vecsei B, Körmendi S, Gyarmathy VA, Borbély J, Hermann P. Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study. BMC Oral Health. 2019;19(1):280.CrossRef
38.
go back to reference Yau HT, Yang TJ, Lin YK. Comparison of 3-D printing and 5-axis milling for the production of dental emodels from intra-oral scanning. CAD App. 2016;13:32–8. Yau HT, Yang TJ, Lin YK. Comparison of 3-D printing and 5-axis milling for the production of dental emodels from intra-oral scanning. CAD App. 2016;13:32–8.
39.
go back to reference Jeong Y-G, Lee W-S, Lee K-B. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J Adv Prosthodont. 2018;10(3):245–51.CrossRef Jeong Y-G, Lee W-S, Lee K-B. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J Adv Prosthodont. 2018;10(3):245–51.CrossRef
Metadata
Title
The step further smile virtual planning: milled versus prototyped mock-ups for the evaluation of the designed smile characteristics
Authors
Antonino Lo Giudice
Luca Ortensi
Marco Farronato
Alessandra Lucchese
Erica Lo Castro
Gaetano Isola
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2020
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-020-01145-z

Other articles of this Issue 1/2020

BMC Oral Health 1/2020 Go to the issue