Open Access 01-12-2020 | Research article
Sonic irrigant activation for root canal disinfection: power modes matter!
Published in: BMC Oral Health | Issue 1/2020
Login to get accessAbstract
Background
Sonic irrigant activation has gained widespread popularity among general dentists and endodontists alike in recent years. This in vitro study aimed to evaluate the impact of three power modes of a sonic activation device (EDDY) on its antimicrobial effectiveness in infected root canals.
Methods
The root canals of straight, human roots (n = 120) were prepared to size 40/.06. In a short-term infection experiment, the root canals were inoculated with different microbial species for three days. The following irrigation protocols, using 4 ml of normal saline as irrigant, were performed: negative control, manual rinsing, sonic irrigant activation at power modes “low”, “medium” and “high”. In a second, long-term experiment, testing the same irrigation protocols, inoculation lasted 21 days and sodium hypochlorite was used as irrigant. Sequential infection control samples were assessed using culture assays. The statistical analysis included one-way analysis of variance of log10-scaled counts of colony-forming units (CFU) with post-hoc comparisons using Bonferroni corrections and Chi2 tests (α = 0.05).
Results
In the short-term experiment, the sonic irrigation protocols decreased the number of CFUs by 1.88 log10 units compared with the negative control (p < 0.001). The power modes “medium” and “high” achieved the most effective reduction of the microbial load. In the long-term experiment, microbial regrowth occurred after 7 days unless the device was used at its highest power setting.
Conclusions
The power modes of the sonic irrigation device have a significant impact on the effectiveness for endodontic disinfection. The sonic irrigation device should always be used at the highest power setting in order to maximize its antimicrobial effectiveness.