Skip to main content
Top
Published in: BMC Ear, Nose and Throat Disorders 1/2016

Open Access 01-01-2016 | Technical advance

Using mid infrared technology as new method for the determination of the dwell time of salivary substitutes on three dimensional gingiva models

Authors: Karin Engelhart, Alice Popescu, Jürgen Bernhardt

Published in: BMC Ear, Nose and Throat Disorders | Issue 1/2016

Login to get access

Abstract

Background

Many people suffer from dry mouth (xerostomia) due to radiotherapy treatment of head and neck cancer, diseases like Sjogren’s syndrome or as adverse effects to prescribed medications. Salivary substitute products like gels or sprays are often used for treatment. Efficacy of those oral care products are regularly assessed by validated or even not validated questionnaires. To determine the adhesion effect over time more objectively a new and sensitive method was established. The following study was designed to assess the dwell time of different oral care products in vitro.

Method

Two different types of surfaces were covered with oral care products and washed using a definite protocol with artificial saliva salt solution. First, oral care gels or oral care sprays were spread to a polystyrene surface of 2.25 cm2, then onto cell based three-dimensional gingiva models. The surfaces were washed ten times with artificial saliva salt solution. The resulting washing solutions were examined using mid infrared spectroscopy in order to detect ingredients of the oral care products.

Results

All assessed oral care gels or oral care sprays and their components were detected very sensitive. Even traces of the products were detected in the eluent and thus enabled to differentiate the dwell times of the different products. In general, the dwell time of oral care gels on polystyrene or gingiva models was longer than that of oral care sprays. The use of gingiva models improved the differentiation between different products.

Conclusions

MIR spectroscopy turned out to be a sensitive method to detect salivary substitutes. Differences between single components and different products can be detected. The described method is a simple, reliable and easy process to evaluate the dwell time of oral care products in vitro and thus a useful tool to design optimised salivary substitute products.

Ethics

This is an in vitro study. No ethics or consent was required for this study.
Literature
2.
go back to reference Petersen PE. Oral cancer prevention and control – The approach of the World Health Organization. Oral Oncol. 2009;45:454–60.CrossRefPubMed Petersen PE. Oral cancer prevention and control – The approach of the World Health Organization. Oral Oncol. 2009;45:454–60.CrossRefPubMed
5.
go back to reference Proctor GB, Carpenter GH. Regulation of salivary gland function by autonomic nerves. Auton Neurosci. 2007;133:3–18.CrossRefPubMed Proctor GB, Carpenter GH. Regulation of salivary gland function by autonomic nerves. Auton Neurosci. 2007;133:3–18.CrossRefPubMed
6.
go back to reference Davies AN, Shorthose K. Parasympathomimetic drugs for the treatment of salivary gland dysfunction due to radiotherapy (review). Cochrane Database Syst Rev. 2007;3:CD003782.PubMed Davies AN, Shorthose K. Parasympathomimetic drugs for the treatment of salivary gland dysfunction due to radiotherapy (review). Cochrane Database Syst Rev. 2007;3:CD003782.PubMed
7.
go back to reference Furness S, Bryan G, McMillan R, Worthington HV. Interventions for the management of dry mouth: non-pharmacological interventions. Cochrane Database Syst Rev. 2013;8:CD009603.PubMed Furness S, Bryan G, McMillan R, Worthington HV. Interventions for the management of dry mouth: non-pharmacological interventions. Cochrane Database Syst Rev. 2013;8:CD009603.PubMed
8.
go back to reference Sarapur S, Shilpashree HS. Salivary pacemaker: a review. Dent Res J (Isfahan). 2012;9 Suppl 1:S20–5. Sarapur S, Shilpashree HS. Salivary pacemaker: a review. Dent Res J (Isfahan). 2012;9 Suppl 1:S20–5.
9.
go back to reference Momm F, Volegova-Neher NJ, Schulte-Mönting J, Guttenberger R. Different saliva substitutes for treatment of xerostomia following radiotherapy. Strahlenther Onkol. 2005;181:231–6.CrossRefPubMed Momm F, Volegova-Neher NJ, Schulte-Mönting J, Guttenberger R. Different saliva substitutes for treatment of xerostomia following radiotherapy. Strahlenther Onkol. 2005;181:231–6.CrossRefPubMed
10.
go back to reference Silvestre FJ, Minguez MP, Sune-Negre JM. Clinical evaluation of a new artificial saliva in spray form for patients with dry mouth. Med Oral Patol Cir Bucul. 2009;14:E8–E11. Silvestre FJ, Minguez MP, Sune-Negre JM. Clinical evaluation of a new artificial saliva in spray form for patients with dry mouth. Med Oral Patol Cir Bucul. 2009;14:E8–E11.
11.
go back to reference Hahnel S, Behr M, Handel G, Bürgers R. Saliva substitutes for the treatment of radiation-induced xerostomia – a review. Support Care Cancer. 2009;17:1331–43.CrossRefPubMed Hahnel S, Behr M, Handel G, Bürgers R. Saliva substitutes for the treatment of radiation-induced xerostomia – a review. Support Care Cancer. 2009;17:1331–43.CrossRefPubMed
12.
go back to reference Dubois J, Shaw RA. IR spectroscopy in clinical and diagnostic application. Anal Chem. 2004;76:360A–7A.CrossRefPubMed Dubois J, Shaw RA. IR spectroscopy in clinical and diagnostic application. Anal Chem. 2004;76:360A–7A.CrossRefPubMed
13.
go back to reference Van Eerdenburgh B, Taylor LS. Application of mid-IR spectroscopy for the characterization of pharmaceutical systems. Int J Pharm. 2011;417(1–2):3–16.CrossRef Van Eerdenburgh B, Taylor LS. Application of mid-IR spectroscopy for the characterization of pharmaceutical systems. Int J Pharm. 2011;417(1–2):3–16.CrossRef
14.
go back to reference Wang L, Mizaikoff B. Application of multivariate data-analysis techniques to biomedical diagnostics based on mid-infrared spectroscopy. Anal Bioanal Chem. 2008;391(5):1641–54.CrossRefPubMed Wang L, Mizaikoff B. Application of multivariate data-analysis techniques to biomedical diagnostics based on mid-infrared spectroscopy. Anal Bioanal Chem. 2008;391(5):1641–54.CrossRefPubMed
15.
go back to reference Kong J, Yu S. Fourier transform infrared spectroscopic analysis of protein secondary structures. Acta Biochim Biophys S. 2007;39:549–59.CrossRef Kong J, Yu S. Fourier transform infrared spectroscopic analysis of protein secondary structures. Acta Biochim Biophys S. 2007;39:549–59.CrossRef
16.
go back to reference Pidgeon C, Apostol G, Marcovich R. Fourier transform infrared assay of liposomal lipids. Anal Biochem. 1989;1:28–32.CrossRef Pidgeon C, Apostol G, Marcovich R. Fourier transform infrared assay of liposomal lipids. Anal Biochem. 1989;1:28–32.CrossRef
17.
go back to reference Jamme F, Vindigni JD, Méchin V, Cherifi T, Chardot T, Froissard M. Single cell synchrotron FT-IR microspectroscopy reveals a link between neutral lipid and storage carbohydrate fluxes in S. cerevisiae. PLoS One. 2013; doi: 10.1371/journal.pone.0074421 Jamme F, Vindigni JD, Méchin V, Cherifi T, Chardot T, Froissard M. Single cell synchrotron FT-IR microspectroscopy reveals a link between neutral lipid and storage carbohydrate fluxes in S. cerevisiae. PLoS One. 2013; doi: 10.​1371/​journal.​pone.​0074421
18.
go back to reference Masuch R, Moss DA. Stopped flow apparatus for time-resolved Fourier transform infrared difference spectroscopy of biological macromolecules in 1H2O. Appl Spectrosc. 2003;57:1407–18.CrossRefPubMed Masuch R, Moss DA. Stopped flow apparatus for time-resolved Fourier transform infrared difference spectroscopy of biological macromolecules in 1H2O. Appl Spectrosc. 2003;57:1407–18.CrossRefPubMed
19.
go back to reference Max JJ, Chapados C. Glucose and fructose hydrates in aqueous solution by IR spectroscopy. J Phys Chem A. 2007;111(14):2679–89.CrossRefPubMed Max JJ, Chapados C. Glucose and fructose hydrates in aqueous solution by IR spectroscopy. J Phys Chem A. 2007;111(14):2679–89.CrossRefPubMed
20.
go back to reference Strug I, Utzat C, Cappione A 3rd, Gutierrez S, Amara R, Lento J, Capito F, Skudas R, Chernokalskaya E, Nadler T. Development of a univariate membrane-based mid-infrared method for protein quantitation and total lipid content analysis of biological samples.. J Anal Methods Chem. 2014; doi: 10.1155/2014/657079 Strug I, Utzat C, Cappione A 3rd, Gutierrez S, Amara R, Lento J, Capito F, Skudas R, Chernokalskaya E, Nadler T. Development of a univariate membrane-based mid-infrared method for protein quantitation and total lipid content analysis of biological samples.. J Anal Methods Chem. 2014; doi: 10.​1155/​2014/​657079
21.
go back to reference Culbert J, Cozzolino D, Ristic R, Wilkinson K. Classification of Sparkling Wine Style and Quality by MIR Spectroscopy. Molecules. 2015;20(5):8341–56.CrossRefPubMed Culbert J, Cozzolino D, Ristic R, Wilkinson K. Classification of Sparkling Wine Style and Quality by MIR Spectroscopy. Molecules. 2015;20(5):8341–56.CrossRefPubMed
22.
go back to reference Dixit V, Cho BK, Obendorf K, Tewari J. Identifications of household’s spores using mid infrared spectroscopy. Spectrochim Acta A Mol Biomol Spectrosc. 2013;123C:490–6. Dixit V, Cho BK, Obendorf K, Tewari J. Identifications of household’s spores using mid infrared spectroscopy. Spectrochim Acta A Mol Biomol Spectrosc. 2013;123C:490–6.
23.
go back to reference Cozzolino D, Cynkar W, Shah N, Smith P. Technical solutions for analysis of grape juice, must, and wine: The role of infrared spectroscopy and chemometrics. Anal Bioanal Chem. 2011;401:1475–84.CrossRefPubMed Cozzolino D, Cynkar W, Shah N, Smith P. Technical solutions for analysis of grape juice, must, and wine: The role of infrared spectroscopy and chemometrics. Anal Bioanal Chem. 2011;401:1475–84.CrossRefPubMed
24.
go back to reference Smilowitz JT, Gho DS, Mirmiran M, German JB, Underwood MA. Rapid Measurement of Human Milk Macronutrients in the Neonatal Intensive Care Unit: Accuracy and Precision of Fourier Transform Mid-Infrared Spectroscopy. J Hum Lact. 2014;30(2):180–9.CrossRefPubMed Smilowitz JT, Gho DS, Mirmiran M, German JB, Underwood MA. Rapid Measurement of Human Milk Macronutrients in the Neonatal Intensive Care Unit: Accuracy and Precision of Fourier Transform Mid-Infrared Spectroscopy. J Hum Lact. 2014;30(2):180–9.CrossRefPubMed
Metadata
Title
Using mid infrared technology as new method for the determination of the dwell time of salivary substitutes on three dimensional gingiva models
Authors
Karin Engelhart
Alice Popescu
Jürgen Bernhardt
Publication date
01-01-2016
Publisher
BioMed Central
Published in
BMC Ear, Nose and Throat Disorders / Issue 1/2016
Electronic ISSN: 1472-6815
DOI
https://doi.org/10.1186/s12901-016-0025-5

Other articles of this Issue 1/2016

BMC Ear, Nose and Throat Disorders 1/2016 Go to the issue