Skip to main content
Top
Published in: BMC Surgery 1/2016

Open Access 01-12-2016 | Technical advance

A locking compression plate as an external fixator for treating infected nonunion of the humeral diaphysis

Authors: Cong Xiao, Fan Tang, Yong Zhou, Wenli Zhang, Yi Luo, Hong Duan, Chongqi Tu

Published in: BMC Surgery | Issue 1/2016

Login to get access

Abstract

Background

Infected nonunion of the humeral diaphysis is a challenging problem for orthopedic surgeons. This study aimed to evaluate the outcome of using a locking compression plate (LCP) as a definitive external fixator in the management of infected nonunion of the humeral diaphysis after failure of internal fixation.

Methods

We retrospectively reviewed a series of seven patients with infected nonunion of the humeral diaphysis treated with an LCP as an external fixator between June 2010 and August 2014. There were five males and two females, with an average age of 40.9 years. Six out of seven patients had been definitively diagnosed with infection due to known bacteria by germiculture. The clinical and radiographic outcomes were retrospectively evaluated.

Results

All patients were followed-up for a mean period of 26.3 months (range 12–48 months). All fractures obtained complete bone union, and the average time to bone union was 7.9 months (range 3.5–15 months). All infections were eventually resolved without any recurrence of deep infection. Pin tract infection was only seen in one case. Only one patient had transient radial nerve palsy after surgery for traction. The average shortening length of the affected upper limb was 3 cm (range 2–4 cm) compared with the contralateral limb. At the last follow-up, the average Disabilities of the Arm, Shoulder and Hand score of the involved limbs was 3.2 (range 0–13.4). All patients obtained excellent or good functional results, and returned to their original work.

Conclusions

The novel use of an LCP as a definitive external fixator was an effective method for treating infected nonunion of the humeral diaphysis. However, a large-scale prospective clinical study is still needed to verify these findings.
Literature
1.
go back to reference Bassiony AA, Almoatasem AM, Abdelhady AM, et al. Infected non-union of the humerus after failure of surgical treatment: management using the Orthofix external fixator. Ann Acad Med Singapore. 2009;38:1090–4.PubMed Bassiony AA, Almoatasem AM, Abdelhady AM, et al. Infected non-union of the humerus after failure of surgical treatment: management using the Orthofix external fixator. Ann Acad Med Singapore. 2009;38:1090–4.PubMed
2.
go back to reference Jain AK, Sinha S. Infected nonunion of the long bones. Clin Orthop Relat Res. 2005:57-65 Jain AK, Sinha S. Infected nonunion of the long bones. Clin Orthop Relat Res. 2005:57-65
3.
go back to reference Gualdrini G, Pascarella R, Colozza A, et al. Infected nonunion of the humerus. Chir Organi Mov. 2000;85:251–5.PubMed Gualdrini G, Pascarella R, Colozza A, et al. Infected nonunion of the humerus. Chir Organi Mov. 2000;85:251–5.PubMed
4.
go back to reference Haidukewych GJ, Sperling JW. Results of treatment of infected humeral nonunions: the Mayo Clinic experience. Clin Orthop Relat Res. 2003;25–30. Haidukewych GJ, Sperling JW. Results of treatment of infected humeral nonunions: the Mayo Clinic experience. Clin Orthop Relat Res. 2003;25–30.
5.
go back to reference Lammens J, Bauduin G, Driesen R, et al. Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res. 1998;223–230. Lammens J, Bauduin G, Driesen R, et al. Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res. 1998;223–230.
6.
go back to reference Patel VR, Menon DK, Pool RD, et al. Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg Br. 2000;82:977–83.CrossRefPubMed Patel VR, Menon DK, Pool RD, et al. Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg Br. 2000;82:977–83.CrossRefPubMed
7.
8.
go back to reference Apivatthakakul T, Sananpanich K. The locking compression plate as an external fixator for bone transport in the treatment of a large distal tibial defect: a case report. Injury. 2007;38:1318–25.CrossRefPubMed Apivatthakakul T, Sananpanich K. The locking compression plate as an external fixator for bone transport in the treatment of a large distal tibial defect: a case report. Injury. 2007;38:1318–25.CrossRefPubMed
9.
go back to reference Kloen P. Supercutaneous plating: use of a locking compression plate as an external fixator. J Orthop Trauma. 2009;23:72–5.CrossRefPubMed Kloen P. Supercutaneous plating: use of a locking compression plate as an external fixator. J Orthop Trauma. 2009;23:72–5.CrossRefPubMed
10.
11.
go back to reference Zhou Y, Wang Y, Liu L, et al. Locking compression plate as an external fixator in the treatment of closed distal tibial fractures. Int Orthop. 2015;39:2227–37.CrossRefPubMed Zhou Y, Wang Y, Liu L, et al. Locking compression plate as an external fixator in the treatment of closed distal tibial fractures. Int Orthop. 2015;39:2227–37.CrossRefPubMed
12.
go back to reference Qiu XS, Yuan H, Zheng X, et al. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Arch Orthop Trauma Surg. 2014;134:383–8.CrossRefPubMed Qiu XS, Yuan H, Zheng X, et al. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Arch Orthop Trauma Surg. 2014;134:383–8.CrossRefPubMed
14.
go back to reference Ma CH, Wu CH, Yu SW, et al. Staged external and internal less-invasive stabilisation system plating for open proximal tibial fractures. Injury. 2010;41:190–6.CrossRefPubMed Ma CH, Wu CH, Yu SW, et al. Staged external and internal less-invasive stabilisation system plating for open proximal tibial fractures. Injury. 2010;41:190–6.CrossRefPubMed
15.
go back to reference Ma CH, Tu YK, Yeh JH, et al. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures. J Trauma. 2011;71:614–9.CrossRefPubMed Ma CH, Tu YK, Yeh JH, et al. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures. J Trauma. 2011;71:614–9.CrossRefPubMed
16.
go back to reference Ma CH, Wu CH, Tu YK, et al. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study. Injury. 2013;44:1097–101.CrossRefPubMed Ma CH, Wu CH, Tu YK, et al. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study. Injury. 2013;44:1097–101.CrossRefPubMed
17.
go back to reference Sirisreetreerux N, Sa-Ngasoongsong P, Chanplakorn P, et al. Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture. Orthop Rev (Pavia). 2013;5:52–5.CrossRef Sirisreetreerux N, Sa-Ngasoongsong P, Chanplakorn P, et al. Using a reconstruction locking compression plate as external fixator in infected open clavicle fracture. Orthop Rev (Pavia). 2013;5:52–5.CrossRef
18.
go back to reference He X, Zhang J, Li M, et al. Surgical treatment of extra-articular or simple intra-articular distal tibial fractures: MIPO versus supercutaneous plating. Orthopedics. 2014;37:e925–931.CrossRefPubMed He X, Zhang J, Li M, et al. Surgical treatment of extra-articular or simple intra-articular distal tibial fractures: MIPO versus supercutaneous plating. Orthopedics. 2014;37:e925–931.CrossRefPubMed
19.
go back to reference Gummesson C, Atroshi I, Ekdahl C. The disabilities of the arm, shoulder and hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord. 2003;4:11.CrossRefPubMedPubMedCentral Gummesson C, Atroshi I, Ekdahl C. The disabilities of the arm, shoulder and hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord. 2003;4:11.CrossRefPubMedPubMedCentral
20.
go back to reference Ring D, Kloen P, Kadzielski J, et al. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res. 2004(425):50-54. Ring D, Kloen P, Kadzielski J, et al. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res. 2004(425):50-54.
21.
go back to reference Kanchanomai C, Phiphobmongkol V. Biomechanical evaluation of fractured tibia externally fixed with an LCP. J Appl Biomech. 2012;28:587–92.CrossRefPubMed Kanchanomai C, Phiphobmongkol V. Biomechanical evaluation of fractured tibia externally fixed with an LCP. J Appl Biomech. 2012;28:587–92.CrossRefPubMed
22.
go back to reference Kerkhoffs GM, Kuipers MM, Marti RK, et al. External fixation with standard AO-plates: technique, indications, and results in 31 cases. J Orthop Trauma. 2003;17:61–4.CrossRefPubMed Kerkhoffs GM, Kuipers MM, Marti RK, et al. External fixation with standard AO-plates: technique, indications, and results in 31 cases. J Orthop Trauma. 2003;17:61–4.CrossRefPubMed
23.
go back to reference Zhang J, Ebraheim NA, Li M, et al. External fixation using a locking plate: a reliable way in treating distal tibial fractures. J Orthop Trauma. 2015;29:e454–458.CrossRefPubMed Zhang J, Ebraheim NA, Li M, et al. External fixation using a locking plate: a reliable way in treating distal tibial fractures. J Orthop Trauma. 2015;29:e454–458.CrossRefPubMed
24.
go back to reference Zhang J, Ebraheim N, Li M, et al. External fixation using femoral less invasive stabilization system plate in tibial proximal metaphyseal fracture. Clin Orthop Surg. 2015;7:8–14.CrossRefPubMedPubMedCentral Zhang J, Ebraheim N, Li M, et al. External fixation using femoral less invasive stabilization system plate in tibial proximal metaphyseal fracture. Clin Orthop Surg. 2015;7:8–14.CrossRefPubMedPubMedCentral
25.
go back to reference Pugh DM, McKee MD. Advances in the management of humeral nonunion. J Am Acad Orthop Surg. 2003;11:48–59.CrossRefPubMed Pugh DM, McKee MD. Advances in the management of humeral nonunion. J Am Acad Orthop Surg. 2003;11:48–59.CrossRefPubMed
26.
go back to reference Schuind FA, Burny F, Chao EYS. Biomechanical properties and design considerations in upper extremity external fixation. Hand Clin. 1993;9:543–53.PubMed Schuind FA, Burny F, Chao EYS. Biomechanical properties and design considerations in upper extremity external fixation. Hand Clin. 1993;9:543–53.PubMed
Metadata
Title
A locking compression plate as an external fixator for treating infected nonunion of the humeral diaphysis
Authors
Cong Xiao
Fan Tang
Yong Zhou
Wenli Zhang
Yi Luo
Hong Duan
Chongqi Tu
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2016
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-016-0167-9

Other articles of this Issue 1/2016

BMC Surgery 1/2016 Go to the issue