Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2018

Open Access 01-12-2018 | Research article

Optimal viewing angles of intraoperative fluoroscopy for detecting screw penetration in proximal humeral fractures: a cadaveric study

Authors: Qiuke Wang, Yifei Liu, Ming Zhang, Yu Zhu, Lei Wang, Yunfeng Chen

Published in: BMC Musculoskeletal Disorders | Issue 1/2018

Login to get access

Abstract

Background

To identify the optimal viewing angles for every proximal screw in PHILOS plate-fixed proximal humeral fractures.

Methods

Three fresh-frozen human cadaveric bodies with six intact shoulders were studied. All three bodies were put in the beach chair position and PHILOS plates were placed on the proximal humerus. Head screws penetrating 1 mm into the joint were fitted one by one. Fluoroscopy was conducted in the 180° horizontal plane and the 120° coronal plane to analyze each screw’s penetration in every shoulder. Images were taken every 5°, then all images were analyzed to identify the sensitive angles.

Results

The range of optimal viewing angles to visualize penetration of every head screw was identified. In the coronal plane, the angles in the range between 0° and 10° were sensitive to all screws except No. 8 and No. 9. Furthermore, penetration of screws No. 8 and 9 could not be identified on any axillary view, but could be identified in the horizontal plane from − 30° to − 10° and from 10° to 35° respectively.

Conclusions

We recommend a 0°–10° axillary view with 30° arm abduction combined with two horizontal angles in the range of − 30° to − 10° and 10° to 35° for routine fluoroscopy during surgery. Our results will be helpful in avoiding primary screw penetration.
Literature
2.
go back to reference Ricchetti ET, Warrender WJ, Abboud JA. Use of locking plates in the treatment of proximal humerus fractures. J Shoulder Elbow Surg. 2010;19:66–75.CrossRefPubMed Ricchetti ET, Warrender WJ, Abboud JA. Use of locking plates in the treatment of proximal humerus fractures. J Shoulder Elbow Surg. 2010;19:66–75.CrossRefPubMed
8.
go back to reference Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A. Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res. 2006;442:115–20.CrossRefPubMed Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A. Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res. 2006;442:115–20.CrossRefPubMed
17.
go back to reference Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005;430:176–81. Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005;430:176–81.
Metadata
Title
Optimal viewing angles of intraoperative fluoroscopy for detecting screw penetration in proximal humeral fractures: a cadaveric study
Authors
Qiuke Wang
Yifei Liu
Ming Zhang
Yu Zhu
Lei Wang
Yunfeng Chen
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2018
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-018-2247-8

Other articles of this Issue 1/2018

BMC Musculoskeletal Disorders 1/2018 Go to the issue