Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2018

Open Access 01-12-2018 | Research article

Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III

Authors: Luigi Tarallo, Raffaele Mugnai, Martina Rocchi, Francesco Capra, Fabio Catani

Published in: BMC Musculoskeletal Disorders | Issue 1/2018

Login to get access

Abstract

Background

The treatment of comminuted radial head fractures can include prosthetic replacement or open reduction and internal fixation. The purpose of this study is to evaluate the results of two different internal fixation systems for Mason type II-III radial head fractures.

Methods

Between 2005 and 2015, 82 patients were treated using pins and 65 patients by mini-screws. The follow-up protocol included: a clinical evaluation 15 days after surgery, and clinical and radiographic evaluations performed at 30 and 60 day intervals, unless any complications were reported by the patient. Over a period of at least 12-months of follow-up, patients were checked and interviewed. Clinical examinations included elbow range of motion (ROM), arm, shoulder and hand Disabilities, (DASH), and the Mayo Elbow Performance Score (MEPS).

Results

Sixty-one subjects who had been treated with mini-screws were clinically reviewed at a mean 47.3 ± 35.8 month of follow-up; all patients who had been treated using absorbable pins were evaluated at a mean 82.5 ± 20.6 month of follow-up. No significant statistically differences were observed between the two groups in the mean ROM, DASH, and MEPS scores. Residual pain was reported in 15.8%of the patients treated by pins and 9.2% patients treated by mini-screws. Secondary displacement of fracture fragments was observed in 8.5% patients treated by pins and 1.6% using mini-screws.

Conclusions

Both absorbable pins and mini-screws provided adequate strength and rigidity, allowing good clinical and functional scores at a mid-term follow-up. However, a higher rate of secondary displacement of the fracture fragments was reported among subjects who had been treated using absorbable pins.
Literature
1.
go back to reference Hall JA, McKee MD. Posterolateral rotatory instability of the elbow following radial head resection. J Bone Joint Surg Am. 2005;87:1571–9.PubMed Hall JA, McKee MD. Posterolateral rotatory instability of the elbow following radial head resection. J Bone Joint Surg Am. 2005;87:1571–9.PubMed
2.
go back to reference Geel CW, Palmer A. Radial head fractures and their effect on the distal radioulnar joint. A rationale for treatment. Clin Orthop Relat Res. 1992;275:79–84. Geel CW, Palmer A. Radial head fractures and their effect on the distal radioulnar joint. A rationale for treatment. Clin Orthop Relat Res. 1992;275:79–84.
3.
go back to reference Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head: comparison of resection and internal fixation. Surgical technique. J Bone Joint Surg Am. 2006;88(suppl 1 pt 1):11–23.CrossRefPubMed Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head: comparison of resection and internal fixation. Surgical technique. J Bone Joint Surg Am. 2006;88(suppl 1 pt 1):11–23.CrossRefPubMed
4.
go back to reference Sanders RA, French HG. Open reduction and internal fixation of comminuted radial head fractures. Am J Sports Med. 1986;14:130–5.CrossRefPubMed Sanders RA, French HG. Open reduction and internal fixation of comminuted radial head fractures. Am J Sports Med. 1986;14:130–5.CrossRefPubMed
5.
go back to reference Ring D, Quintero J, Jupiter J. Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg Am. 2002;84:1811–5.CrossRefPubMed Ring D, Quintero J, Jupiter J. Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg Am. 2002;84:1811–5.CrossRefPubMed
6.
go back to reference Leigh WB, Ball CM. Radial head reconstruction versus replacement in the treatment of terrible triad injuries of the elbow. J Shoulder Elb Surg. 2012;21(10):1336–41.CrossRef Leigh WB, Ball CM. Radial head reconstruction versus replacement in the treatment of terrible triad injuries of the elbow. J Shoulder Elb Surg. 2012;21(10):1336–41.CrossRef
7.
go back to reference Pike JM, Grewal R, Athwal GS, Faber KJ, King GJ. Open reduction and internal fixation of radial head fractures: do outcomes differ between simple and complex injuries? Clin Orthop Relat Res. 2014 Jul;472(7):2120–7.CrossRefPubMedPubMedCentral Pike JM, Grewal R, Athwal GS, Faber KJ, King GJ. Open reduction and internal fixation of radial head fractures: do outcomes differ between simple and complex injuries? Clin Orthop Relat Res. 2014 Jul;472(7):2120–7.CrossRefPubMedPubMedCentral
8.
go back to reference Mason M. Some observations on fractures of the head of the radius with a review of one hundred cases. Br J Surg. 1959;42:123–32.CrossRef Mason M. Some observations on fractures of the head of the radius with a review of one hundred cases. Br J Surg. 1959;42:123–32.CrossRef
9.
go back to reference Hotchkiss RN. Displaced fractures of the radial head: internal fixation or excision? J Am Acad Orthop Surg. 1997;5:1–10.CrossRefPubMed Hotchkiss RN. Displaced fractures of the radial head: internal fixation or excision? J Am Acad Orthop Surg. 1997;5:1–10.CrossRefPubMed
10.
go back to reference Hudak PL, Amadio PC, Bombardier C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The upper extremity collaborative group (UECG). Am J Ind Med. 1996;29(6):602–8.CrossRefPubMed Hudak PL, Amadio PC, Bombardier C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The upper extremity collaborative group (UECG). Am J Ind Med. 1996;29(6):602–8.CrossRefPubMed
11.
go back to reference Morrey BF, An KN, Chao EYS. Functional evaluation of the elbow. In: Morrey BF, editor. The elbow and its disorders. Philadelphia: WB Saunders; 1993. p. 86–9. Morrey BF, An KN, Chao EYS. Functional evaluation of the elbow. In: Morrey BF, editor. The elbow and its disorders. Philadelphia: WB Saunders; 1993. p. 86–9.
12.
go back to reference Giffin JR, King GJ, Patterson SD, Johnson JA. Internal fixation of radial neck fractures: an in vitro biomechanical analysis. Clin Biomech. 2004;19:358–61.CrossRef Giffin JR, King GJ, Patterson SD, Johnson JA. Internal fixation of radial neck fractures: an in vitro biomechanical analysis. Clin Biomech. 2004;19:358–61.CrossRef
13.
go back to reference Koslowsky TC, Mader K, Dargel J, Koebke J, Hellmich M, Pennig D. Reconstruction of a Mason type-III fracture of the radial head using four different fixation techniques. An experimental study. J Bone Joint Surg Br. 2007;89(11):1545–50.CrossRefPubMed Koslowsky TC, Mader K, Dargel J, Koebke J, Hellmich M, Pennig D. Reconstruction of a Mason type-III fracture of the radial head using four different fixation techniques. An experimental study. J Bone Joint Surg Br. 2007;89(11):1545–50.CrossRefPubMed
14.
go back to reference Claes L, Burri C, Kiefer H, Mutschler W. Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflächen. Aktuel Traumatol. 1986;16:74–7.PubMed Claes L, Burri C, Kiefer H, Mutschler W. Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflächen. Aktuel Traumatol. 1986;16:74–7.PubMed
15.
go back to reference Vasenius J, Vainionpää S, Vihtonen K, Mero M, Mikkola J, Rokkanen P, Törmälä P. Biodegradable self-reinforced polyglycolide (SR-PGA) composite rods coated with slowly biodegradable polymers for fracture fixation. Strength and strength retention in vitro and in vivo. Clin Materials. 1989;4:307–17.CrossRef Vasenius J, Vainionpää S, Vihtonen K, Mero M, Mikkola J, Rokkanen P, Törmälä P. Biodegradable self-reinforced polyglycolide (SR-PGA) composite rods coated with slowly biodegradable polymers for fracture fixation. Strength and strength retention in vitro and in vivo. Clin Materials. 1989;4:307–17.CrossRef
16.
go back to reference Vihtonen K. Fixation of rabbit osteotomies with biodegradable polyglycolic acid thread. Acta Orthop Scand. 1988;59:279–83.CrossRefPubMed Vihtonen K. Fixation of rabbit osteotomies with biodegradable polyglycolic acid thread. Acta Orthop Scand. 1988;59:279–83.CrossRefPubMed
17.
go back to reference Hirvensalo E, Böstman O, Rokkanen P. Absorbable polyglycolide pins in fixation of displaced fractures of the radial head. Arch Orthop Trauma Surg. 1990;109(5):258–61.CrossRefPubMed Hirvensalo E, Böstman O, Rokkanen P. Absorbable polyglycolide pins in fixation of displaced fractures of the radial head. Arch Orthop Trauma Surg. 1990;109(5):258–61.CrossRefPubMed
18.
go back to reference Pelto K, Hirvensalo E, Bostman O, Rokkanen P. Treatment of radial head fractures with absorbable polyglycolide pins: a study on the security of the fixation in 38 cases. J Orthop Trauma. 1994;8(2):94–8.CrossRefPubMed Pelto K, Hirvensalo E, Bostman O, Rokkanen P. Treatment of radial head fractures with absorbable polyglycolide pins: a study on the security of the fixation in 38 cases. J Orthop Trauma. 1994;8(2):94–8.CrossRefPubMed
19.
go back to reference Helling HJ, Prokop A, Schmid HU, Nagel M, Lilienthal J, Rehm KE. Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study. J Shoulder Elb Surg. 2006;15(4):479–85.CrossRef Helling HJ, Prokop A, Schmid HU, Nagel M, Lilienthal J, Rehm KE. Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study. J Shoulder Elb Surg. 2006;15(4):479–85.CrossRef
20.
go back to reference Givissis PK, Symeonidis PD, Ditsios KT, Dionellis PS, Christodoulou AG. Late results of absorbable pin fixation in the treatment of radial head fractures. Clin Orthop Relat Res. 2008;466(5):1217–24.CrossRefPubMedPubMedCentral Givissis PK, Symeonidis PD, Ditsios KT, Dionellis PS, Christodoulou AG. Late results of absorbable pin fixation in the treatment of radial head fractures. Clin Orthop Relat Res. 2008;466(5):1217–24.CrossRefPubMedPubMedCentral
21.
go back to reference Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G. Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop. 2015;39(8):1659-64. Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G. Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop. 2015;39(8):1659-64.
Metadata
Title
Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III
Authors
Luigi Tarallo
Raffaele Mugnai
Martina Rocchi
Francesco Capra
Fabio Catani
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2018
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-018-2014-x

Other articles of this Issue 1/2018

BMC Musculoskeletal Disorders 1/2018 Go to the issue