Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2017

Open Access 01-12-2017 | Research article

Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors

Authors: Sandra Mathews, Marco Burkhard, Nabil Serrano, Karl Link, Martin Häusler, Nakita Frater, Ingeborg Franke, Helena Bischofberger, Florian M. Buck, Dominic Gascho, Michael Thali, Steffen Serowy, Magdalena Müller-Gerbl, Gareth Harper, Ford Qureshi, Thomas Böni, Hans-Rudolf Bloch, Oliver Ullrich, Frank-Jakobus Rühli, Elisabeth Eppler

Published in: BMC Musculoskeletal Disorders | Issue 1/2017

Login to get access

Abstract

Background

Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements.

Methods

Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60–98 years).

Results

Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle −1.0° ± 4.0°.

Conclusion

This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.
Literature
1.
go back to reference Alentorn-Geli E, Samitier G, Torrens C, Wright TW. Reverse shoulder arthroplasty. Part 2: Systematic review of reoperations, revisions, problems, and complications. Int J Shoulder Surg. 2015;9(2):60–7.CrossRefPubMedPubMedCentral Alentorn-Geli E, Samitier G, Torrens C, Wright TW. Reverse shoulder arthroplasty. Part 2: Systematic review of reoperations, revisions, problems, and complications. Int J Shoulder Surg. 2015;9(2):60–7.CrossRefPubMedPubMedCentral
2.
go back to reference Hawi N, Reinhold A, Suero EM, Liodakis E, Przyklenk S, Brandes J, Schmiedl A, Krettek C, Meller R. The anatomic basis for the arthroscopic Latarjet Procedure: A cadaveric study. Am J Sport Med. 2016;44(2):497–503.CrossRef Hawi N, Reinhold A, Suero EM, Liodakis E, Przyklenk S, Brandes J, Schmiedl A, Krettek C, Meller R. The anatomic basis for the arthroscopic Latarjet Procedure: A cadaveric study. Am J Sport Med. 2016;44(2):497–503.CrossRef
3.
go back to reference Merkle TP, Beckmann N, Bruckner T, Zeifang F. Shoulder joint replacement can improve quality of life and outcome in patients with dysmelia: a case series. BMC Musculoskelet Disord. 2016;17:185-193. Merkle TP, Beckmann N, Bruckner T, Zeifang F. Shoulder joint replacement can improve quality of life and outcome in patients with dysmelia: a case series. BMC Musculoskelet Disord. 2016;17:185-193.
4.
go back to reference Longo UG, Petrillo S, Berton A, Denaro V. Reverse total shoulder arthroplasty for the management of fractures of the proximal humerus: a systematic review. Musculoskelet Surg. 2016;100(2):83–91.CrossRefPubMed Longo UG, Petrillo S, Berton A, Denaro V. Reverse total shoulder arthroplasty for the management of fractures of the proximal humerus: a systematic review. Musculoskelet Surg. 2016;100(2):83–91.CrossRefPubMed
5.
go back to reference von Eisenhart-Rothe R, Muller-Gerbl M, Wiedemann E, Englmeier KH, Graichen H. Functional malcentering of the humeral head and asymmetric long-term stress on the glenoid: Potential reasons for glenoid loosening in total shoulder arthroplasty. J Shoulder Elb Surg. 2008;17(5):695–702.CrossRef von Eisenhart-Rothe R, Muller-Gerbl M, Wiedemann E, Englmeier KH, Graichen H. Functional malcentering of the humeral head and asymmetric long-term stress on the glenoid: Potential reasons for glenoid loosening in total shoulder arthroplasty. J Shoulder Elb Surg. 2008;17(5):695–702.CrossRef
6.
go back to reference Gregory TM, Sankey A, Augereau B, Vandenbussche E, Amis A, Emery R, Hansen U. Accuracy of glenoid component placement in total shoulder arthroplasty and its effect on clinical and radiological outcome in a retrospective, longitudinal, monocentric open study. Plos One. 2013;8(10):e75791. Gregory TM, Sankey A, Augereau B, Vandenbussche E, Amis A, Emery R, Hansen U. Accuracy of glenoid component placement in total shoulder arthroplasty and its effect on clinical and radiological outcome in a retrospective, longitudinal, monocentric open study. Plos One. 2013;8(10):e75791.
7.
go back to reference Stephens BF, Hebert CT, Azar FM, Mihalko WM, Throckmorton TW. Optimal baseplate rotational alignment for locking-screw fixation in reverse total shoulder arthroplasty: a three-dimensional computer-aided design study. J Shoulder Elb Surg. 2015;24(9):1367–71.CrossRef Stephens BF, Hebert CT, Azar FM, Mihalko WM, Throckmorton TW. Optimal baseplate rotational alignment for locking-screw fixation in reverse total shoulder arthroplasty: a three-dimensional computer-aided design study. J Shoulder Elb Surg. 2015;24(9):1367–71.CrossRef
8.
go back to reference Zumstein V, Kraljevic M, Hoechel S, Conzen A, Nowakowski AM, Muller-Gerbl M. The glenohumeral joint - a mismatching system? A morphological analysis of the cartilaginous and osseous curvature of the humeral head and the glenoid cavity. J Orthop Surg Res. 2014;9:34.CrossRefPubMedPubMedCentral Zumstein V, Kraljevic M, Hoechel S, Conzen A, Nowakowski AM, Muller-Gerbl M. The glenohumeral joint - a mismatching system? A morphological analysis of the cartilaginous and osseous curvature of the humeral head and the glenoid cavity. J Orthop Surg Res. 2014;9:34.CrossRefPubMedPubMedCentral
9.
go back to reference Chae SW, Kim SY, Lee H, Yon JR, Lee J, Han SH. Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty. BMC Musculoskelet Disord. 2014;15:417. Chae SW, Kim SY, Lee H, Yon JR, Lee J, Han SH. Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty. BMC Musculoskelet Disord. 2014;15:417.
10.
go back to reference Langohr GDG, Willing R, Medley JB, Athwal GS, Johnson JA. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter. J Shoulder Elb Surg. 2016;25(4):589–97.CrossRef Langohr GDG, Willing R, Medley JB, Athwal GS, Johnson JA. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter. J Shoulder Elb Surg. 2016;25(4):589–97.CrossRef
11.
go back to reference Lädermann A, Gueorguiev B, Charbonnier C, Stimec BV, Fasel JHD, Zderic I, Hagen J, Walch G. Scapular notching on kinematic simulated range of motion after Reverse Shoulder Arthroplasty is not the result of impingement in adduction. Medicine. 2015;94(38):e1615. Lädermann A, Gueorguiev B, Charbonnier C, Stimec BV, Fasel JHD, Zderic I, Hagen J, Walch G. Scapular notching on kinematic simulated range of motion after Reverse Shoulder Arthroplasty is not the result of impingement in adduction. Medicine. 2015;94(38):e1615.
12.
go back to reference Hoenecke HR, Hermida JC, Flores-Hernandez C, D'Lima DD. Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. J Shoulder Elb Surg. 2010;19(2):166–71.CrossRef Hoenecke HR, Hermida JC, Flores-Hernandez C, D'Lima DD. Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. J Shoulder Elb Surg. 2010;19(2):166–71.CrossRef
13.
go back to reference Poon PC, Ting FSH. A 2-dimensional glenoid vault method for measuring glenoid version on computed tomography. J Shoulder Elb Surg. 2012;21(3):329–35.CrossRef Poon PC, Ting FSH. A 2-dimensional glenoid vault method for measuring glenoid version on computed tomography. J Shoulder Elb Surg. 2012;21(3):329–35.CrossRef
14.
go back to reference Privitera DM, Siegel EJ, Miller LR, Sinz NJ, Higgins LD. Glenoid version and its relationship to glenohumeral instability and labral tears. J Shoulder Elb Surg. 2016;25(7):1056–63.CrossRef Privitera DM, Siegel EJ, Miller LR, Sinz NJ, Higgins LD. Glenoid version and its relationship to glenohumeral instability and labral tears. J Shoulder Elb Surg. 2016;25(7):1056–63.CrossRef
15.
go back to reference Maurer A, Fucentese SF, Pfirrmann CWA, Wirth SH, Djahangiri A, Jost B, Gerber C. Assessment of glenoid inclination on routine clinical radiographs and computed tomography examinations of the shoulder. J Shoulder Elb Surg. 2012;21(8):1096–103.CrossRef Maurer A, Fucentese SF, Pfirrmann CWA, Wirth SH, Djahangiri A, Jost B, Gerber C. Assessment of glenoid inclination on routine clinical radiographs and computed tomography examinations of the shoulder. J Shoulder Elb Surg. 2012;21(8):1096–103.CrossRef
16.
go back to reference Lädermann A, Stimec BV, Denard PJ, Cunningham G, Collin P, Fasel JHD. Injury to the axillary nerve after reverse shoulder arthroplasty: An anatomical study. Orthop Traumatol-Sur. 2014;100(1):105–8.CrossRef Lädermann A, Stimec BV, Denard PJ, Cunningham G, Collin P, Fasel JHD. Injury to the axillary nerve after reverse shoulder arthroplasty: An anatomical study. Orthop Traumatol-Sur. 2014;100(1):105–8.CrossRef
17.
go back to reference Molony DC, Gheiti AJC, Kennedy J, Green C, Schepens A, Mullett HJ. A cadaveric model for suprascapular nerve injury during glenoid component screw insertion in reverse-geometry shoulder arthroplasty. J Shoulder Elb Surg. 2011;20(8):1323–7.CrossRef Molony DC, Gheiti AJC, Kennedy J, Green C, Schepens A, Mullett HJ. A cadaveric model for suprascapular nerve injury during glenoid component screw insertion in reverse-geometry shoulder arthroplasty. J Shoulder Elb Surg. 2011;20(8):1323–7.CrossRef
18.
go back to reference Wang VM, Krishnan R, Ugwonali OFC, Flatow EL, Bigliani LU, Ateshian GA. Biomechanical evaluation of a novel glenoid design in total shoulder arthroplasty. J Shoulder Elb Surg. 2005;14(1):129s–40s.CrossRef Wang VM, Krishnan R, Ugwonali OFC, Flatow EL, Bigliani LU, Ateshian GA. Biomechanical evaluation of a novel glenoid design in total shoulder arthroplasty. J Shoulder Elb Surg. 2005;14(1):129s–40s.CrossRef
19.
go back to reference DiStefano JG, Park AY, Nguyen TQD, Diederichs G, Buckley JM, Montgomery WH. Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty. J Shoulder Elb Surg. 2011;20(3):467–76.CrossRef DiStefano JG, Park AY, Nguyen TQD, Diederichs G, Buckley JM, Montgomery WH. Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty. J Shoulder Elb Surg. 2011;20(3):467–76.CrossRef
20.
go back to reference Farshad M, Grogli M, Catanzaro S, Gerber C. Revision of reversed total shoulder arthroplasty. Indications and outcome. BMC Musculoskelet Disord. 2012;13:160. Farshad M, Grogli M, Catanzaro S, Gerber C. Revision of reversed total shoulder arthroplasty. Indications and outcome. BMC Musculoskelet Disord. 2012;13:160.
21.
go back to reference Shi LL, Freehill MT, Yannopoulos P, Warner JJ. Suprascapular nerve: is it important in cuff pathology? Adv Orthop. 2012;2012:516985. Shi LL, Freehill MT, Yannopoulos P, Warner JJ. Suprascapular nerve: is it important in cuff pathology? Adv Orthop. 2012;2012:516985.
22.
go back to reference McFarland EG, Huri G, Hyun YS, Petersen SA, Srikumaran U. Reverse total shoulder arthroplasty without bone-grafting for severe glenoid bone loss in patients with osteoarthritis and Intact rotator cuff. J Bone Joint Surg Am. 2016;98(21):1801–7.CrossRefPubMed McFarland EG, Huri G, Hyun YS, Petersen SA, Srikumaran U. Reverse total shoulder arthroplasty without bone-grafting for severe glenoid bone loss in patients with osteoarthritis and Intact rotator cuff. J Bone Joint Surg Am. 2016;98(21):1801–7.CrossRefPubMed
23.
go back to reference Mizuno N, Denard PJ, Raiss P, Walch G. Reverse total shoulder arthroplasty for primary glenohumeral osteoarthritis in patients with a biconcave glenoid. J Bone Joint Surg Am. 2013;95(14):1297–304.CrossRefPubMed Mizuno N, Denard PJ, Raiss P, Walch G. Reverse total shoulder arthroplasty for primary glenohumeral osteoarthritis in patients with a biconcave glenoid. J Bone Joint Surg Am. 2013;95(14):1297–304.CrossRefPubMed
24.
go back to reference Anetzberger H, Maier M, Zysk S, Schulz C, Putz R. The architecture of the subacromial space in humans with full thickness supraspinatus tears. Z Orthop Grenzgeb. 2004;142(2):221–7.CrossRef Anetzberger H, Maier M, Zysk S, Schulz C, Putz R. The architecture of the subacromial space in humans with full thickness supraspinatus tears. Z Orthop Grenzgeb. 2004;142(2):221–7.CrossRef
25.
go back to reference Anetzberger H, Putz R. The scapula: Principles of construction and stress. Acta Anat. 1996;156(1):70–80.CrossRefPubMed Anetzberger H, Putz R. The scapula: Principles of construction and stress. Acta Anat. 1996;156(1):70–80.CrossRefPubMed
26.
go back to reference Churchill RS, Brems JJ, Kotschi H. Glenoid size, inclination, and version: An anatomic study. J Shoulder Elb Surg. 2001;10(4):327–32.CrossRef Churchill RS, Brems JJ, Kotschi H. Glenoid size, inclination, and version: An anatomic study. J Shoulder Elb Surg. 2001;10(4):327–32.CrossRef
27.
go back to reference Gumina S, Albino P, Giaracuni M, Vestri A, Ripani M, Postacchini F. The safe zone for avoiding suprascapular nerve injury during shoulder arthroscopy: an anatomical study on 500 dry scapulae. J Shoulder Elb Surg. 2011;20(8):1317–22.CrossRef Gumina S, Albino P, Giaracuni M, Vestri A, Ripani M, Postacchini F. The safe zone for avoiding suprascapular nerve injury during shoulder arthroscopy: an anatomical study on 500 dry scapulae. J Shoulder Elb Surg. 2011;20(8):1317–22.CrossRef
29.
go back to reference Polguj M, Majos A, Waszczykowski M, Fabiś J, Stefańczyk K, Podgórski M, Topol M. A computed tomography study on the correlation between the morphometry of the suprascapular notch and anthropometric measurements of the scapula. Folia Morphol. 2015;75(1):87–92. Polguj M, Majos A, Waszczykowski M, Fabiś J, Stefańczyk K, Podgórski M, Topol M. A computed tomography study on the correlation between the morphometry of the suprascapular notch and anthropometric measurements of the scapula. Folia Morphol. 2015;75(1):87–92.
30.
go back to reference Prescher A. Anatomical basics, variations, and degenerative changes of the shoulder joint and shoulder girdle. Eur J Radiol. 2000;35(2):88–102.CrossRefPubMed Prescher A. Anatomical basics, variations, and degenerative changes of the shoulder joint and shoulder girdle. Eur J Radiol. 2000;35(2):88–102.CrossRefPubMed
31.
go back to reference Codsi MJ, Bennetts C, Gordiev K, Boeck DM, Kwon Y, Brems J, Powell K, Iannotti JP. Normal glenoid vault anatomy and validation of a novel glenoid implant shape. J Shoulder Elb Surg. 2008;17(3):471–8.CrossRef Codsi MJ, Bennetts C, Gordiev K, Boeck DM, Kwon Y, Brems J, Powell K, Iannotti JP. Normal glenoid vault anatomy and validation of a novel glenoid implant shape. J Shoulder Elb Surg. 2008;17(3):471–8.CrossRef
32.
go back to reference Sangam MR, Sarada Devi SS, Krupadanam K, Anasuya K. A study on the morphology of the suprascapular notch and its distance from the glenoid cavity. J Clin Diagn Res. 2013;7(2):189–92.CrossRefPubMedPubMedCentral Sangam MR, Sarada Devi SS, Krupadanam K, Anasuya K. A study on the morphology of the suprascapular notch and its distance from the glenoid cavity. J Clin Diagn Res. 2013;7(2):189–92.CrossRefPubMedPubMedCentral
33.
go back to reference Lädermann A, Denard PJ, Burkhart SS. Injury of the suprascapular nerve during Latarjet Procedure: An anatomic study. Arthroscopy. 2012;28(3):316–21.CrossRefPubMed Lädermann A, Denard PJ, Burkhart SS. Injury of the suprascapular nerve during Latarjet Procedure: An anatomic study. Arthroscopy. 2012;28(3):316–21.CrossRefPubMed
34.
go back to reference Longo UG, Forriol F, Loppini M, Lanotte A, Salvatore G, Maffulli N, Denaro V. The safe zone for avoiding suprascapular nerve injury in bone block procedures for shoulder instability. A cadaveric study. Knee Surg Sport Tr A. 2015;23(5):1506–10.CrossRef Longo UG, Forriol F, Loppini M, Lanotte A, Salvatore G, Maffulli N, Denaro V. The safe zone for avoiding suprascapular nerve injury in bone block procedures for shoulder instability. A cadaveric study. Knee Surg Sport Tr A. 2015;23(5):1506–10.CrossRef
35.
go back to reference Maquieira GJ, Gerber C, Schneeberger AG. Suprascapular nerve palsy after the Latarjet procedure. J Shoulder Elb Surg. 2007;16(2):e13–5.CrossRef Maquieira GJ, Gerber C, Schneeberger AG. Suprascapular nerve palsy after the Latarjet procedure. J Shoulder Elb Surg. 2007;16(2):e13–5.CrossRef
36.
go back to reference Morgan RT, Henn RF, Paryavi E, Dreese J. Injury to the suprascapular nerve during superior labrum anterior and posterior repair: Is a rotator interval portal safer than an anterosuperior portal? Arthroscopy. 2014;30(11):1418–23.CrossRefPubMed Morgan RT, Henn RF, Paryavi E, Dreese J. Injury to the suprascapular nerve during superior labrum anterior and posterior repair: Is a rotator interval portal safer than an anterosuperior portal? Arthroscopy. 2014;30(11):1418–23.CrossRefPubMed
37.
go back to reference Bigliani LU, Dalsey RM, McCann PD, April EW. An anatomical study of the suprascapular nerve. Arthroscopy. 1990;6(4):301–5.CrossRefPubMed Bigliani LU, Dalsey RM, McCann PD, April EW. An anatomical study of the suprascapular nerve. Arthroscopy. 1990;6(4):301–5.CrossRefPubMed
38.
go back to reference Shishido H, Kikuchi S. Injury of the suprascapular nerve in shoulder surgery: An anatomic study. J Shoulder Elb Surg. 2001;10(4):372–6.CrossRef Shishido H, Kikuchi S. Injury of the suprascapular nerve in shoulder surgery: An anatomic study. J Shoulder Elb Surg. 2001;10(4):372–6.CrossRef
39.
go back to reference Tom JA, Mesfin A, Shah MP, Javandel M, Lee DJ, Cerynik DL, Amin NH. Anatomical considerations of the suprascapular nerve in rotator cuff repairs. Anat Res In. 2014;2014. doi:10.1155/2014/674179. Tom JA, Mesfin A, Shah MP, Javandel M, Lee DJ, Cerynik DL, Amin NH. Anatomical considerations of the suprascapular nerve in rotator cuff repairs. Anat Res In. 2014;2014. doi:10.​1155/​2014/​674179.
40.
go back to reference Longo UG, Loppini M, Rizzello G, Romeo G, Huijsmans PE, Denaro V. Glenoid and humeral head bone loss in traumatic anterior glenohumeral instability: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):392–414.CrossRefPubMed Longo UG, Loppini M, Rizzello G, Romeo G, Huijsmans PE, Denaro V. Glenoid and humeral head bone loss in traumatic anterior glenohumeral instability: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):392–414.CrossRefPubMed
41.
go back to reference Codsi MJ, Bennetts C, Powell K, Iannotti JP. Locations for screw fixed beyond the glenoid vault for fixation of glenoid implants into the scapula: An anatomic study. J Shoulder Elb Surg. 2007;16(3):84s–9s.CrossRef Codsi MJ, Bennetts C, Powell K, Iannotti JP. Locations for screw fixed beyond the glenoid vault for fixation of glenoid implants into the scapula: An anatomic study. J Shoulder Elb Surg. 2007;16(3):84s–9s.CrossRef
42.
go back to reference Hart ND, Clark JC, Wade Krause FR, Kissenberth MJ, Bragg WE, Hawkins RJ. Glenoid screw position in the Encore Reverse Shoulder Prosthesis: an anatomic dissection study of screw relationship to surrounding structures. J Shoulder Elb Surg. 2013;22(6):814–20.CrossRef Hart ND, Clark JC, Wade Krause FR, Kissenberth MJ, Bragg WE, Hawkins RJ. Glenoid screw position in the Encore Reverse Shoulder Prosthesis: an anatomic dissection study of screw relationship to surrounding structures. J Shoulder Elb Surg. 2013;22(6):814–20.CrossRef
43.
go back to reference Athwal GS, MacDermid JC, Reddy KM, Marsh JP, Faber KJ, Drosdowech D. Does bony increased-offset reverse shoulder arthroplasty decrease scapular notching? J Shoulder Elb Surg. 2015;24(3):468–73.CrossRef Athwal GS, MacDermid JC, Reddy KM, Marsh JP, Faber KJ, Drosdowech D. Does bony increased-offset reverse shoulder arthroplasty decrease scapular notching? J Shoulder Elb Surg. 2015;24(3):468–73.CrossRef
44.
go back to reference Hudson A, Peckmann TR, Logar CJ, Meek S. Sex determination in a contemporary Mexican population using the scapula. J Forensic Leg Med. 2016;37:91–6.CrossRefPubMed Hudson A, Peckmann TR, Logar CJ, Meek S. Sex determination in a contemporary Mexican population using the scapula. J Forensic Leg Med. 2016;37:91–6.CrossRefPubMed
45.
go back to reference Friedman RJ, Hawthorne KB, Genez BM. The use of computerized-tomography in the measurement of glenoid version. J Bone Joint Surg Am. 1992;74A(7):1032–7.CrossRef Friedman RJ, Hawthorne KB, Genez BM. The use of computerized-tomography in the measurement of glenoid version. J Bone Joint Surg Am. 1992;74A(7):1032–7.CrossRef
46.
go back to reference Schramek GGR, Stoevesandt D, Reising A, Kielstein JT, Hiss M, Kielstein H. Imaging in anatomy: a comparison of imaging techniques in embalmed human cadavers. BMC Med Educ. 2013;13(1):1.CrossRef Schramek GGR, Stoevesandt D, Reising A, Kielstein JT, Hiss M, Kielstein H. Imaging in anatomy: a comparison of imaging techniques in embalmed human cadavers. BMC Med Educ. 2013;13(1):1.CrossRef
47.
go back to reference Martin R, Saller K. Lehrbuch der Anthropologie in systematischer Darstellung mit besonderer Berücksichtigung der anthropologischen Methoden. G. Stuttgart: Fischer; 1957. Martin R, Saller K. Lehrbuch der Anthropologie in systematischer Darstellung mit besonderer Berücksichtigung der anthropologischen Methoden. G. Stuttgart: Fischer; 1957.
48.
go back to reference Lima. SMR Surgical technique. Villanova di San Daniele del Friuli, Italy: Lima Corporate; 2012. Lima. SMR Surgical technique. Villanova di San Daniele del Friuli, Italy: Lima Corporate; 2012.
49.
go back to reference Burkhard M, Mathews S, Link K, Franke I, Harper G, Quereshi F, Bloch H, Ullrich O, Eppler E, Ruhli F. The human glenoid morphology - a comparative cadaver based study. Am J Phys Anthropol. 2015;156:95–6. Burkhard M, Mathews S, Link K, Franke I, Harper G, Quereshi F, Bloch H, Ullrich O, Eppler E, Ruhli F. The human glenoid morphology - a comparative cadaver based study. Am J Phys Anthropol. 2015;156:95–6.
50.
go back to reference Mathews S, Burkhard M, Link K, Franke I, Harper G, Quereshi F, Bloch HR, Ullrich O, Ruhli F, Eppler E. Assessing bone and soft tissue morphology of the scapula region: a cadaver dissection-based study to improve uncemented glenoid metalback fixation. Faseb J. 2014;28(1). Mathews S, Burkhard M, Link K, Franke I, Harper G, Quereshi F, Bloch HR, Ullrich O, Ruhli F, Eppler E. Assessing bone and soft tissue morphology of the scapula region: a cadaver dissection-based study to improve uncemented glenoid metalback fixation. Faseb J. 2014;28(1).
51.
go back to reference Knowles NK, Ferreira LM, Athwal GS. Premorbid retroversion is significantly greater in type B2 glenoids. J Shoulder Elb Surg. 2016;25(7):1064–8.CrossRef Knowles NK, Ferreira LM, Athwal GS. Premorbid retroversion is significantly greater in type B2 glenoids. J Shoulder Elb Surg. 2016;25(7):1064–8.CrossRef
52.
go back to reference Bryce CD, Davison AC, Lewis GS, Wang L, Flemming DJ, Armstrong AD. Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation. J Bone Joint Surg Am. 2010;92(3):692–9.CrossRefPubMed Bryce CD, Davison AC, Lewis GS, Wang L, Flemming DJ, Armstrong AD. Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation. J Bone Joint Surg Am. 2010;92(3):692–9.CrossRefPubMed
53.
go back to reference Nyffeler RW, Jost B, Pfirrmann CWA, Gerber C. Measurement of glenoid version: Conventional radiographs versus computed tomography scans. J Shoulder Elb Surg. 2003;12(5):493–6.CrossRef Nyffeler RW, Jost B, Pfirrmann CWA, Gerber C. Measurement of glenoid version: Conventional radiographs versus computed tomography scans. J Shoulder Elb Surg. 2003;12(5):493–6.CrossRef
54.
go back to reference Ekin A, Magden O, Icke C. Anatomy and relationship of the suprascapular nerve. Int Congr Ser. 1995;1085:379–84. Ekin A, Magden O, Icke C. Anatomy and relationship of the suprascapular nerve. Int Congr Ser. 1995;1085:379–84.
55.
go back to reference Sinkeet SR, Awori KO, Odula PO, Ogeng'o JA, Mwachaka PM. The suprascapular notch: its morphology and distance from the glenoid cavity in a Kenyan population. Folia Morphol. 2010;69(4):241–5. Sinkeet SR, Awori KO, Odula PO, Ogeng'o JA, Mwachaka PM. The suprascapular notch: its morphology and distance from the glenoid cavity in a Kenyan population. Folia Morphol. 2010;69(4):241–5.
56.
go back to reference Athwal GS, Faber KJ. Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate. Int Orthop. 2016;40(1):109–13.CrossRefPubMed Athwal GS, Faber KJ. Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate. Int Orthop. 2016;40(1):109–13.CrossRefPubMed
57.
go back to reference Polguj M, Jedrzejewski KS, Podgorski M, Topol M. Correlation between morphometry of the suprascapular notch and anthropometric measurements of the scapula. Folia Morphol. 2011;70(2):109–15. Polguj M, Jedrzejewski KS, Podgorski M, Topol M. Correlation between morphometry of the suprascapular notch and anthropometric measurements of the scapula. Folia Morphol. 2011;70(2):109–15.
58.
go back to reference Piponov HI, Savin D, Shah N, Esposito D, Schwartz B, Moretti V, Goldberg B. Glenoid version and size: does gender, ethnicity, or body size play a role? Int Orthop. 2016;40(11):2347-53. Piponov HI, Savin D, Shah N, Esposito D, Schwartz B, Moretti V, Goldberg B. Glenoid version and size: does gender, ethnicity, or body size play a role? Int Orthop. 2016;40(11):2347-53.
59.
go back to reference Wong AS, Gallo L, Kuhn JE, Carpenter JE, Hughes RE. The effect of glenoid inclination on superior humeral head migration. J Shoulder Elb Surg. 2003;12(4):360–4.CrossRef Wong AS, Gallo L, Kuhn JE, Carpenter JE, Hughes RE. The effect of glenoid inclination on superior humeral head migration. J Shoulder Elb Surg. 2003;12(4):360–4.CrossRef
60.
go back to reference Van Haver A, Heylen S, Vuylsteke K, Declercq G, Verborgt O. Reliability analysis of glenoid component inclination measurements on postoperative radiographs and computed tomography-based 3D models in total and reversed shoulder arthroplasty patients. J Shoulder Elb Surg. 2016;25(4):632–40.CrossRef Van Haver A, Heylen S, Vuylsteke K, Declercq G, Verborgt O. Reliability analysis of glenoid component inclination measurements on postoperative radiographs and computed tomography-based 3D models in total and reversed shoulder arthroplasty patients. J Shoulder Elb Surg. 2016;25(4):632–40.CrossRef
61.
go back to reference Dallalana RJ, McMahon RA, East B, Geraghty L. Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty. Int J Shoulder Surg. 2016;10(2):59–66.CrossRefPubMedPubMedCentral Dallalana RJ, McMahon RA, East B, Geraghty L. Accuracy of patient-specific instrumentation in anatomic and reverse total shoulder arthroplasty. Int J Shoulder Surg. 2016;10(2):59–66.CrossRefPubMedPubMedCentral
Metadata
Title
Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors
Authors
Sandra Mathews
Marco Burkhard
Nabil Serrano
Karl Link
Martin Häusler
Nakita Frater
Ingeborg Franke
Helena Bischofberger
Florian M. Buck
Dominic Gascho
Michael Thali
Steffen Serowy
Magdalena Müller-Gerbl
Gareth Harper
Ford Qureshi
Thomas Böni
Hans-Rudolf Bloch
Oliver Ullrich
Frank-Jakobus Rühli
Elisabeth Eppler
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2017
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-016-1373-4

Other articles of this Issue 1/2017

BMC Musculoskeletal Disorders 1/2017 Go to the issue