Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2016

Open Access 01-12-2016 | Research article

Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation

Authors: Yutaka Inaba, Naomi Kobayashi, Haruka Suzuki, Hiroyuki Ike, So Kubota, Tomoyuki Saito

Published in: BMC Musculoskeletal Disorders | Issue 1/2016

Login to get access

Abstract

Background

In total hip arthroplasty (THA), tilting of the pelvis alters the cup placement angles. Thus, the cup angles need to be planned with consideration of the effects of pelvic tilt. In the present study, we evaluated the efficacy of preoperative planning for implant placement with consideration of pelvic tilt in THA, and the accuracy of a CT-based computer navigation for implant positioning.

Methods

We examined 75 hips of 75 patients who underwent THA and were followed-up for one year postoperatively. The patients were divided into three groups (anterior, intermediate, posterior tilt) according to their preoperative pelvic tilt. Preoperative planning for implant placement was made with consideration of pelvic tilt and a CT-based navigation was used to execute the preoperative planning. Cup inclination, cup anteversion, and combined anteversion (CA) in supine and standing positions were examined 1 year after THA. The accuracy of the computer navigation was also examined.

Results

Mean CA was 35.0 ± 5.8° in supine position and 39.3 ± 5.7° in standing position. CA did not differ among the three subgroups (anterior, intermediate, posterior tilt) in either supine or standing position, indicating implant placements to be equally effective. The desired CA (37.3°) was midway between those in supine and standing positions for each subgroup. Respective mean absolute errors between preoperative planning and postoperative CT measurement was 5.3 ± 5.2° for CA.

Conclusion

We obtained favorable THA results with preoperative planning with consideration of pelvic tilt by demonstrating supine and standing CA to be unaffected by preoperative pelvic tilt one year postoperatively. Mean absolute error of CA between preoperative planning and postoperative measurement was 5° with use of the CT-based navigation.
Literature
1.
go back to reference Dorr LD, Wolf AW, Chandler R, Conaty JP. Classification and treatment of dislocations of total hip arthroplasty. Clin Orthop Relat Res. 1983;173:151–8. Dorr LD, Wolf AW, Chandler R, Conaty JP. Classification and treatment of dislocations of total hip arthroplasty. Clin Orthop Relat Res. 1983;173:151–8.
2.
go back to reference Fackler CD, Poss R. Dislocation in total hip arthroplasties. Clin Orthop Relat Res. 1980;151:169–78. Fackler CD, Poss R. Dislocation in total hip arthroplasties. Clin Orthop Relat Res. 1980;151:169–78.
3.
go back to reference Siebenrock KA, Kalbermatten DF, Ganz R. Effect of pelvic tilt on acetabular retroversion: a study of pelvis from cadavers. Clin Orthop Relat Res. 2003;407:241–8.CrossRef Siebenrock KA, Kalbermatten DF, Ganz R. Effect of pelvic tilt on acetabular retroversion: a study of pelvis from cadavers. Clin Orthop Relat Res. 2003;407:241–8.CrossRef
4.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg. 1978;60-A:217–20.CrossRef Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg. 1978;60-A:217–20.CrossRef
5.
go back to reference Kummer FJ, Shah S, Iyer S, DiCesare PE. The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty. 1999;14:509–13.CrossRefPubMed Kummer FJ, Shah S, Iyer S, DiCesare PE. The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty. 1999;14:509–13.CrossRefPubMed
6.
go back to reference Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–21.CrossRefPubMed Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–21.CrossRefPubMed
7.
go back to reference Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006;39:1315–23.CrossRefPubMed Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006;39:1315–23.CrossRefPubMed
8.
go back to reference Lembeck B, Mueller O, Reize P, Wuelker N. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop. 2005;76:517–23.CrossRefPubMed Lembeck B, Mueller O, Reize P, Wuelker N. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop. 2005;76:517–23.CrossRefPubMed
9.
go back to reference Babisch JW, Layher F, Amiot LP. The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg. 2008;90-A:357–65.CrossRef Babisch JW, Layher F, Amiot LP. The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg. 2008;90-A:357–65.CrossRef
10.
go back to reference DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE. Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res. 2006;453:272–6.CrossRefPubMed DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE. Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res. 2006;453:272–6.CrossRefPubMed
11.
go back to reference Eddine TA, Migaud H, Chntelot C, Cotton A, Fontaine C, Duquennoy A. Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat. 2001;23:105–10.CrossRefPubMed Eddine TA, Migaud H, Chntelot C, Cotton A, Fontaine C, Duquennoy A. Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat. 2001;23:105–10.CrossRefPubMed
12.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg. 1969;51:737–55.CrossRefPubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg. 1969;51:737–55.CrossRefPubMed
13.
go back to reference Konishi N, Mieno T. Determination of acetabular coverage of the femoral head with use of a single anteroposterior radiograph. A new computerized technique. J Bone Joint Surg. 1993;75-A:1318–33.CrossRef Konishi N, Mieno T. Determination of acetabular coverage of the femoral head with use of a single anteroposterior radiograph. A new computerized technique. J Bone Joint Surg. 1993;75-A:1318–33.CrossRef
14.
go back to reference Lazennec JY, Charlot N, Gorin M, Roger B, Arafati N, Bissery A, et al. Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning. Surg Radiol Anat. 2004;26:136–44.CrossRefPubMed Lazennec JY, Charlot N, Gorin M, Roger B, Arafati N, Bissery A, et al. Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning. Surg Radiol Anat. 2004;26:136–44.CrossRefPubMed
15.
go back to reference Zhu J, Wan Z, Dorr L. Quantification of pelvic tilt in total hip arthroplasty. Clin Orthop Relat Res. 2010;468:571–5.CrossRefPubMed Zhu J, Wan Z, Dorr L. Quantification of pelvic tilt in total hip arthroplasty. Clin Orthop Relat Res. 2010;468:571–5.CrossRefPubMed
16.
go back to reference Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–51.CrossRef Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–51.CrossRef
17.
go back to reference Ishida T, Inaba Y, Kobayashi N, Iwamoto N, Yukizawa Y, Choe H, et al. Changes in pelvic tilt following total hip arthroplasty. J Orthop Sci. 2011;16:682–8.CrossRefPubMed Ishida T, Inaba Y, Kobayashi N, Iwamoto N, Yukizawa Y, Choe H, et al. Changes in pelvic tilt following total hip arthroplasty. J Orthop Sci. 2011;16:682–8.CrossRefPubMed
18.
go back to reference Suzuki H, Inaba Y, Kobayashi N, Ishida T, Ike H, Saito T. Positional and chronological change in pelvic tilt five years after total hip arthroplasty: A three-dimensional analysis. J Arthroplasty. 2016;31(1):317–22.CrossRefPubMed Suzuki H, Inaba Y, Kobayashi N, Ishida T, Ike H, Saito T. Positional and chronological change in pelvic tilt five years after total hip arthroplasty: A three-dimensional analysis. J Arthroplasty. 2016;31(1):317–22.CrossRefPubMed
19.
go back to reference Blondel B, Parratte S, Tropiano P, Pauly V, Aubaniac JM, Argenson JN. Pelvic tilt measurement before and after total hip arthroplasty. Orthop Traumatol Surg Res. 2009;95:568–72.CrossRefPubMed Blondel B, Parratte S, Tropiano P, Pauly V, Aubaniac JM, Argenson JN. Pelvic tilt measurement before and after total hip arthroplasty. Orthop Traumatol Surg Res. 2009;95:568–72.CrossRefPubMed
20.
go back to reference Taki N, Mitsugi N, Mochida Y, Akamatsu Y, Saito T. Change in pelvic tilt angle 2 to 4 years after total hip arthroplasty. J Arthroplasty. 2012;27:940–4.CrossRefPubMed Taki N, Mitsugi N, Mochida Y, Akamatsu Y, Saito T. Change in pelvic tilt angle 2 to 4 years after total hip arthroplasty. J Arthroplasty. 2012;27:940–4.CrossRefPubMed
21.
go back to reference Tannast M, Langlotz U, Siebenrock KA, Wiese M, Bernsmann K, Langlotz F. Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop Relat Res. 2005;436:144–50.CrossRef Tannast M, Langlotz U, Siebenrock KA, Wiese M, Bernsmann K, Langlotz F. Anatomic referencing of cup orientation in total hip arthroplasty. Clin Orthop Relat Res. 2005;436:144–50.CrossRef
22.
go back to reference Fujii M, Nakashima Y, Sato T, Akiyama M, Iwamoto Y. Acetabular tilt correlates acetabular version and coverage in hip dysplasia. Clin Orthop Relat Res. 2012;470:2827–35.CrossRefPubMedPubMedCentral Fujii M, Nakashima Y, Sato T, Akiyama M, Iwamoto Y. Acetabular tilt correlates acetabular version and coverage in hip dysplasia. Clin Orthop Relat Res. 2012;470:2827–35.CrossRefPubMedPubMedCentral
23.
go back to reference Kanemura T, Imagama S. Spino-pelvic alignment in an asymptomatic Japanese population: Mean and variance of upright thoracolumbar spino-pelvic alignment in Japanese. J Bone Joint Surg. 2009;28:558–67 (in Japanese). Kanemura T, Imagama S. Spino-pelvic alignment in an asymptomatic Japanese population: Mean and variance of upright thoracolumbar spino-pelvic alignment in Japanese. J Bone Joint Surg. 2009;28:558–67 (in Japanese).
24.
go back to reference Legaye J, Duval-Beaupère G, Hecquet J, Marty C. Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J. 1998;7:99–103.CrossRefPubMedPubMedCentral Legaye J, Duval-Beaupère G, Hecquet J, Marty C. Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves. Eur Spine J. 1998;7:99–103.CrossRefPubMedPubMedCentral
25.
go back to reference Roussouly P, Gollogly S, Berthonnaud E, Dimnet J. Classification of the normal variation in the sagittal alignment of the human lumbar spine and pelvis in the standing position. Spine. 2005;30:346–53.CrossRefPubMed Roussouly P, Gollogly S, Berthonnaud E, Dimnet J. Classification of the normal variation in the sagittal alignment of the human lumbar spine and pelvis in the standing position. Spine. 2005;30:346–53.CrossRefPubMed
26.
go back to reference Digioia 3rd AM, Jaramaz B, Plakseychuk AY, Moody Jr JE, Nikou C, Labarca RS, et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002;17:359–64.CrossRefPubMed Digioia 3rd AM, Jaramaz B, Plakseychuk AY, Moody Jr JE, Nikou C, Labarca RS, et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002;17:359–64.CrossRefPubMed
27.
go back to reference Kitada M, Nakamura N, Iwana D, Kakimoto A, Nishii T, Sugano N. Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty. 2011;26:674–9.CrossRefPubMed Kitada M, Nakamura N, Iwana D, Kakimoto A, Nishii T, Sugano N. Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty. 2011;26:674–9.CrossRefPubMed
Metadata
Title
Preoperative planning for implant placement with consideration of pelvic tilt in total hip arthroplasty: postoperative efficacy evaluation
Authors
Yutaka Inaba
Naomi Kobayashi
Haruka Suzuki
Hiroyuki Ike
So Kubota
Tomoyuki Saito
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2016
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-016-1120-x

Other articles of this Issue 1/2016

BMC Musculoskeletal Disorders 1/2016 Go to the issue