Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2016

Open Access 01-12-2016 | Research article

Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system)

Authors: Debora Soccal Schwertner, Raul Oliveira, Giovana Zarpellon Mazo, Fabiane Rosa Gioda, Christian Roberto Kelber, Alessandra Swarowsky

Published in: BMC Musculoskeletal Disorders | Issue 1/2016

Login to get access

Abstract

Background

Several posture evaluation devices have been used to detect deviations of the vertebral column. However it has been observed that the instruments present measurement errors related to the equipment, environment or measurement protocol. This study aimed to build, validate, analyze the reliability and describe a measurement protocol for the use of the Posture Evaluation Rotating Platform System (SPGAP, Brazilian abbreviation).

Methods

The posture evaluation system comprises a Posture Evaluation Rotating Platform, video camera, calibration support and measurement software. Two pilot studies were carried out with 102 elderly individuals (average age 69 years old, SD = ±7.3) to establish a protocol for SPGAP, controlling the measurement errors related to the environment, equipment and the person under evaluation. Content validation was completed with input from judges with expertise in posture measurement. The variation coefficient method was used to validate the measurement by the instrument of an object with known dimensions. Finally, reliability was established using repeated measurements of the known object.

Results

Expert content judges gave the system excellent ratings for content validity (mean 9.4 out of 10; SD 1.13). The measurement of an object with known dimensions indicated excellent validity (all measurement errors <1 %) and test-retest reliability. A total of 26 images were needed to stabilize the system. Participants in the pilot studies indicated that they felt comfortable throughout the assessment. The use of only one image can offer measurements that underestimate or overestimate the reality. To verify the images of objects with known dimensions the values for the width and height were, respectively, CV 0.88 (width) and 2.33 (height), SD 0.22 (width) and 0.35 (height), minimum and maximum values 24.83–25.2 (width) and 14.56 – 15.75 (height). In the analysis of different images (similar) of an individual, greater discrepancies were observed in the values found. The cervical index, for example, presented minimum and maximum values of 15.38 and 37.5, a coefficient of variation of 0.29 and a standard deviation of 6.78.

Conclusions

The SPGAP was shown to be a valid and reliable instrument for the quantitative analysis of body posture with applicability and clinical use, since it managed to reduce several measurement errors, amongst which parallax distortion.
Literature
1.
go back to reference Silvestrini-Biavati A, Migliorati M, Demarziani E, Tecco S, Silvestrini-Biavati P, Polimeni A, Saccucci M. Clinical association between teeth malocclusions, wrong posture and ocular convergence disorders: an epidemiological investigation on primary school children. BMC Pediatr. 2013;13:12.CrossRefPubMedPubMedCentral Silvestrini-Biavati A, Migliorati M, Demarziani E, Tecco S, Silvestrini-Biavati P, Polimeni A, Saccucci M. Clinical association between teeth malocclusions, wrong posture and ocular convergence disorders: an epidemiological investigation on primary school children. BMC Pediatr. 2013;13:12.CrossRefPubMedPubMedCentral
2.
go back to reference Conti PBM, Sakano E, Ribeiro MAGO, Schivinski CIS, Ribeiro JD. Assessment of the body posture of mouth-breathing children and adolescents. J Pediatr. 2011;87(4):357–63.CrossRef Conti PBM, Sakano E, Ribeiro MAGO, Schivinski CIS, Ribeiro JD. Assessment of the body posture of mouth-breathing children and adolescents. J Pediatr. 2011;87(4):357–63.CrossRef
3.
go back to reference Melo RS, Silva PWA, Silva LVC, Toscano CFS. Vertebral Column Posture Evaluation in Children and Teenagers with Auditive Deficiency. Arq Int Otorrinolaringol/Intl Arch Otorhinolaryngol. 2011;15(2):195–202. Melo RS, Silva PWA, Silva LVC, Toscano CFS. Vertebral Column Posture Evaluation in Children and Teenagers with Auditive Deficiency. Arq Int Otorrinolaringol/Intl Arch Otorhinolaryngol. 2011;15(2):195–202.
4.
go back to reference Hahn PT, Ulguim CB, Badaraó AFV. Retrospective analysis of the spine curvatures and pelvic positioning on radiographic images. Saúde. 2011;37(1):31–42. Hahn PT, Ulguim CB, Badaraó AFV. Retrospective analysis of the spine curvatures and pelvic positioning on radiographic images. Saúde. 2011;37(1):31–42.
5.
go back to reference Vrtovec T, Pernus F, Likar B. A review of methods for quantitative evaluation of spinal curvature. Eur Spine J. 2009;18(5):593–607.CrossRefPubMed Vrtovec T, Pernus F, Likar B. A review of methods for quantitative evaluation of spinal curvature. Eur Spine J. 2009;18(5):593–607.CrossRefPubMed
6.
go back to reference Barrett E, McCreesh K, Lewis J. Intrarater and Interrater Reliability of the Flexicurve Index, Flexicurve Angle, and Manual Inclinometer for the Measurement of Thoracic Kyphosis. Rehabil Res Pract. 2013;2013:475870.PubMedPubMedCentral Barrett E, McCreesh K, Lewis J. Intrarater and Interrater Reliability of the Flexicurve Index, Flexicurve Angle, and Manual Inclinometer for the Measurement of Thoracic Kyphosis. Rehabil Res Pract. 2013;2013:475870.PubMedPubMedCentral
7.
go back to reference Oliveira TS, Candotti CT, La Torre M, et al. Validity and reproducibility of the measurements obtained using the flexicurve instrument to evaluate the angles of thoracic and lumbar curvatures of the spine in the sagittal plane. Rehabil Res Pract. 2012;2012:9. Oliveira TS, Candotti CT, La Torre M, et al. Validity and reproducibility of the measurements obtained using the flexicurve instrument to evaluate the angles of thoracic and lumbar curvatures of the spine in the sagittal plane. Rehabil Res Pract. 2012;2012:9.
8.
go back to reference Bandeira FM, Delfino FC, Carvalho GA, Valduga R. Comparison of thoracic kyphosis between sedentary and physically active older adults by the flexicurve method. Rev Bras Cineantropom Desempenho Hum. 2010;12(5):381–6.CrossRef Bandeira FM, Delfino FC, Carvalho GA, Valduga R. Comparison of thoracic kyphosis between sedentary and physically active older adults by the flexicurve method. Rev Bras Cineantropom Desempenho Hum. 2010;12(5):381–6.CrossRef
9.
go back to reference Sacco IC, Picon AP, Ribeiro AP, Sartor CD, Camargo-Junior F, Macedo DO, et al. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry. Braz J Med Biol Res. 2012;45(9):806–10.CrossRefPubMedPubMedCentral Sacco IC, Picon AP, Ribeiro AP, Sartor CD, Camargo-Junior F, Macedo DO, et al. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry. Braz J Med Biol Res. 2012;45(9):806–10.CrossRefPubMedPubMedCentral
10.
go back to reference Fortin C, Feldman DE, Cheriet F, Labelle H. Clinical methods for quantifying body segment posture: a literature review. Disabil Rehabil. 2011;33(5):367–83.CrossRefPubMed Fortin C, Feldman DE, Cheriet F, Labelle H. Clinical methods for quantifying body segment posture: a literature review. Disabil Rehabil. 2011;33(5):367–83.CrossRefPubMed
11.
go back to reference Iunes DH, Bevilaqua-Grossi D, Oliveira AS, Castro FA, Salgado HS. Comparative analysis between visual and computerized photogrammetry postural assessment. Rev Bras Fisioter. 2009;13(4):308–15.CrossRef Iunes DH, Bevilaqua-Grossi D, Oliveira AS, Castro FA, Salgado HS. Comparative analysis between visual and computerized photogrammetry postural assessment. Rev Bras Fisioter. 2009;13(4):308–15.CrossRef
12.
go back to reference Tomkinson L, Grant R, Shaw G. Quantification of the postural and technical errors in asymptomatic adults using direct 3D whole body scan measurements of standing posture. Gait and Posture. 2013;37(2):172–7.CrossRefPubMed Tomkinson L, Grant R, Shaw G. Quantification of the postural and technical errors in asymptomatic adults using direct 3D whole body scan measurements of standing posture. Gait and Posture. 2013;37(2):172–7.CrossRefPubMed
13.
go back to reference Gorton GE, Young ML, Masso PD. Accuracy, Reliability, and Validity of a 3-Dimensional Scanner for Assessing Torso Shape in Idiopathic Scoliosis. Spine. 2012;37(11):957–65.CrossRefPubMed Gorton GE, Young ML, Masso PD. Accuracy, Reliability, and Validity of a 3-Dimensional Scanner for Assessing Torso Shape in Idiopathic Scoliosis. Spine. 2012;37(11):957–65.CrossRefPubMed
14.
go back to reference Watson AWS, Macdonncha CA. Reliable technique for the assessment of posture: assessment criteria for aspects of posture. J Sports Med Phys Fitness. 2000;40(3):260–70.PubMed Watson AWS, Macdonncha CA. Reliable technique for the assessment of posture: assessment criteria for aspects of posture. J Sports Med Phys Fitness. 2000;40(3):260–70.PubMed
15.
go back to reference Kendall FP, Mccreary EK, Provance PG. Músculos: provas e funções. 4th ed. Manole: São Paulo; 1995. Kendall FP, Mccreary EK, Provance PG. Músculos: provas e funções. 4th ed. Manole: São Paulo; 1995.
16.
go back to reference Magee M. Avaliação musculoesquelética. 1st ed. Barueri: Manole; 2002. Magee M. Avaliação musculoesquelética. 1st ed. Barueri: Manole; 2002.
17.
go back to reference Roobottom CA, Mitchell G, Morgan-Hughes G. Radiation- reduction strategies in cardiac computed tomographic angiography. Clin Radiol. 2010;65(11):859–67.CrossRefPubMed Roobottom CA, Mitchell G, Morgan-Hughes G. Radiation- reduction strategies in cardiac computed tomographic angiography. Clin Radiol. 2010;65(11):859–67.CrossRefPubMed
20.
go back to reference Pereira GP. Estudo correlacional entre as medidas angulares da curvatura torácica sagital pelos métodos: radiográfico e régua flexível associada ao avaliador eletrônico. Uberlândia: Dissertação (Mestrado em Fisioterapia)-Centro Universitário do Triângulo; 2005. p. 60. Pereira GP. Estudo correlacional entre as medidas angulares da curvatura torácica sagital pelos métodos: radiográfico e régua flexível associada ao avaliador eletrônico. Uberlândia: Dissertação (Mestrado em Fisioterapia)-Centro Universitário do Triângulo; 2005. p. 60.
21.
22.
go back to reference Rioux M. Colour 3-D Electronic Imaging of the Surface of the Human Body. Opt Lasers Eng. 1997;28:119–35.CrossRef Rioux M. Colour 3-D Electronic Imaging of the Surface of the Human Body. Opt Lasers Eng. 1997;28:119–35.CrossRef
23.
go back to reference Sawacha Z, Carraro E, Del Din S, Guiotto A, Bonaldo L, Punzi L, et al. Biomechanical assessment of balance and posture in subjects with ankylosing spondylitis. J Neuroeng Rehabil. 2012;9:63.CrossRefPubMedPubMedCentral Sawacha Z, Carraro E, Del Din S, Guiotto A, Bonaldo L, Punzi L, et al. Biomechanical assessment of balance and posture in subjects with ankylosing spondylitis. J Neuroeng Rehabil. 2012;9:63.CrossRefPubMedPubMedCentral
24.
go back to reference Melo SIL. Um sistema para determinação do coeficiente de atrito [mu] entre calçados esportivos e pisos usando o plano inclinado. 1995. Santa Maria: Tese (doutorado)- Universidade Federal de Santa Maria; 1995. p. 221. Melo SIL. Um sistema para determinação do coeficiente de atrito [mu] entre calçados esportivos e pisos usando o plano inclinado. 1995. Santa Maria: Tese (doutorado)- Universidade Federal de Santa Maria; 1995. p. 221.
25.
go back to reference Ferreira EA, Duarte M, Maldonado EP, Bersanetti AA, Marques AP. Quantitative assessment of postural alignment in young adults based on photographs of anterior, posterior, and lateral views. J Manip Physiol Ther. 2011;34(6):371–80.CrossRef Ferreira EA, Duarte M, Maldonado EP, Bersanetti AA, Marques AP. Quantitative assessment of postural alignment in young adults based on photographs of anterior, posterior, and lateral views. J Manip Physiol Ther. 2011;34(6):371–80.CrossRef
26.
go back to reference Bullock-Saxton J. Postural alignment in standing: a repeatable study. Aust Physiother. 1993;39:25–9.CrossRef Bullock-Saxton J. Postural alignment in standing: a repeatable study. Aust Physiother. 1993;39:25–9.CrossRef
27.
go back to reference Ribeiro AP, Trombini-Souza F, Iunes DH, Monte-Raso VV. Inter and Intra-Examiner Reliability of Photopodometry and Intra-Examiner Reliability of Photopodoscopy. Rev Bras Fisioter. 2006;10:435–9.CrossRef Ribeiro AP, Trombini-Souza F, Iunes DH, Monte-Raso VV. Inter and Intra-Examiner Reliability of Photopodometry and Intra-Examiner Reliability of Photopodoscopy. Rev Bras Fisioter. 2006;10:435–9.CrossRef
28.
go back to reference Saad M, Masiero D, Lourenço AF, Battistella LR. A proposal of photography-based quantitative evaluation of layed posture. Acta Fisiátrica. 2004;11(2):60–6. Saad M, Masiero D, Lourenço AF, Battistella LR. A proposal of photography-based quantitative evaluation of layed posture. Acta Fisiátrica. 2004;11(2):60–6.
29.
go back to reference Furlanetto TS, Chaise FO, Candotti CT, Comerlato T, Rocha AF, Loss JF. Can skin markers represent spinous process when the posture is changed? Fisioterapia e Pesquisa. 2011;18(2):133–8.CrossRef Furlanetto TS, Chaise FO, Candotti CT, Comerlato T, Rocha AF, Loss JF. Can skin markers represent spinous process when the posture is changed? Fisioterapia e Pesquisa. 2011;18(2):133–8.CrossRef
30.
go back to reference Harlick JC, Milosavljevic S, Milburn PD. Palpation identification of spinous processes in the lumbar spine. Man Ther. 2007;12:56–62.CrossRefPubMed Harlick JC, Milosavljevic S, Milburn PD. Palpation identification of spinous processes in the lumbar spine. Man Ther. 2007;12:56–62.CrossRefPubMed
31.
go back to reference Canales JZ, Cordás TA, Fiquer JT, Cavalcante AF, Moreno RA. Posture and body image in individuals with major depressive disorder: a controlled study. Rev Bras Psiquiatr. 2010;32(4):375–80.CrossRefPubMed Canales JZ, Cordás TA, Fiquer JT, Cavalcante AF, Moreno RA. Posture and body image in individuals with major depressive disorder: a controlled study. Rev Bras Psiquiatr. 2010;32(4):375–80.CrossRefPubMed
32.
go back to reference Ferreira EAG, Duarte M, Maldonado EP, Burke TN, Marques AP. Postural assessment software (PAS/SAPO): validation and reliability. Clinics. 2010;65(7):675–81.CrossRefPubMedPubMedCentral Ferreira EAG, Duarte M, Maldonado EP, Burke TN, Marques AP. Postural assessment software (PAS/SAPO): validation and reliability. Clinics. 2010;65(7):675–81.CrossRefPubMedPubMedCentral
33.
go back to reference Brink Y, Louw Q, Grimmer K, Schreve K, Van Westhuizen G, Jordaan E. Development of a cost effective threedimensional posture analysis tool: validity and reliability. BMC Musculoskelet Disord. 2013;14:335.CrossRefPubMedPubMedCentral Brink Y, Louw Q, Grimmer K, Schreve K, Van Westhuizen G, Jordaan E. Development of a cost effective threedimensional posture analysis tool: validity and reliability. BMC Musculoskelet Disord. 2013;14:335.CrossRefPubMedPubMedCentral
Metadata
Title
Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system)
Authors
Debora Soccal Schwertner
Raul Oliveira
Giovana Zarpellon Mazo
Fabiane Rosa Gioda
Christian Roberto Kelber
Alessandra Swarowsky
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2016
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-016-1057-0

Other articles of this Issue 1/2016

BMC Musculoskeletal Disorders 1/2016 Go to the issue