Background

We undertook the current study to assess whether an accelerometer-based physical activity monitor, the SenseWear Mini Armband (SMA), could be used to provide data on static arm elevation, and to assess the agreement between static arm elevation measures obtained using SMA-derived data and those obtained with a universal goniometer.

Methods

Using a universal goniometer, healthy adult subjects (n = 25, age 30 ± 9 years) had each of right and left arms positioned in a series of set positions between arm-by-side and maximal active arm flexion (anteversion), and arm-by-side and maximal active arm abduction. Subjects wore the SMA throughout positioning, and SMA accelerometer data was used to retrospectively calculate/derive arm elevation angle using a manufacturer-provided algorithm. The Bland-Altman method was used to assess agreement between goniometer-set and SMA-derived arm elevation angles.

Results

There were significant differences between goniometer-set and SMA-derived arm elevation angles for elevation angles ≤ 30 degrees and ≥ 90 degrees (p < 0.05). Bland-Altman plots showed that the greater the angle of elevation, the greater the mean difference between goniometer-set and SMA-derived elevation angles. Adjustment of the manufacturer-provided algorithm for deriving arm elevation angle corrected for this systematic difference, and resulted in 95% limits of agreement ± 12 degrees (flexion) and ± 13 degrees (abduction) across the full range of arm elevation.

Conclusions

The SMA can be used to record data allowing derivation of static arm elevation angle in the upright position, 95% limits of agreement with the universal goniometer being similar to those reported for digital inclinometers and gyroscopes. Physiotherapists looking for innovative methods of recording upper limb range of motion should consider the potential of accelerometer-based physical activity monitors such as the SMA.
Literature
1.
go back to reference Carey MA, Laird DE, Murray KA, Stevenson JR. Reliability, validity, and clinical usability of a digital goniometer. Work. 2010;36:55–66.PubMed Carey MA, Laird DE, Murray KA, Stevenson JR. Reliability, validity, and clinical usability of a digital goniometer. Work. 2010;36:55–66.PubMed
2.
go back to reference Reese NB, Bandy WD. Measurement of range of motion and muscle length: background, history, and basic principles. In: Falk K, editor. Joint range of motion and muscle length testing. 2nd ed. St Louis: Saunders Elsevier; 2010. p. 3–30. Reese NB, Bandy WD. Measurement of range of motion and muscle length: background, history, and basic principles. In: Falk K, editor. Joint range of motion and muscle length testing. 2nd ed. St Louis: Saunders Elsevier; 2010. p. 3–30.
3.
go back to reference van de Pol RJ, van Trijfell E, Lucas C. Inter-rater reliability for measurement of passive physiological range of motion of upper extremity joints is better if instruments are used: a systematic review. J Physiother. 2010;56:7–17.CrossRefPubMed van de Pol RJ, van Trijfell E, Lucas C. Inter-rater reliability for measurement of passive physiological range of motion of upper extremity joints is better if instruments are used: a systematic review. J Physiother. 2010;56:7–17.CrossRefPubMed
4.
go back to reference Reese NB, Bandy WD. Reliability and validity of measurements of range of motion and muscle length testing of the upper extremit. In: Falk K, editor. Joint range of motion and muscle length testing. 2nd ed. St Louis: Saunders Elsevier; 2010. p. 165–82. Reese NB, Bandy WD. Reliability and validity of measurements of range of motion and muscle length testing of the upper extremit. In: Falk K, editor. Joint range of motion and muscle length testing. 2nd ed. St Louis: Saunders Elsevier; 2010. p. 165–82.
5.
go back to reference Kolber MJ, Hanney WJ. The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report. Int J Sports Phys Ther. 2012;7:306–13.PubMedPubMedCentral Kolber MJ, Hanney WJ. The reliability and concurrent validity of shoulder mobility measurements using a digital inclinometer and goniometer: a technical report. Int J Sports Phys Ther. 2012;7:306–13.PubMedPubMedCentral
6.
go back to reference El-Zayat BF, Efe T, Heidrich A, Anetsmann R, Timmesfeld N, Fuchs-Winkelmann S, et al. Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope. BMC Musculoskelet Disord. 2013;14:72.CrossRefPubMedPubMedCentral El-Zayat BF, Efe T, Heidrich A, Anetsmann R, Timmesfeld N, Fuchs-Winkelmann S, et al. Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope. BMC Musculoskelet Disord. 2013;14:72.CrossRefPubMedPubMedCentral
7.
go back to reference Bernmark E, Wiktorin C. A triaxial accelerometer for measuring arm movements. Appl Ergon. 2002;33:541–7.CrossRefPubMed Bernmark E, Wiktorin C. A triaxial accelerometer for measuring arm movements. Appl Ergon. 2002;33:541–7.CrossRefPubMed
8.
go back to reference Luinge HJ, Veltink PH, Baten CTM. Ambulatory measurement of arm orientation. J Biomech. 2007;40:78–85.CrossRefPubMed Luinge HJ, Veltink PH, Baten CTM. Ambulatory measurement of arm orientation. J Biomech. 2007;40:78–85.CrossRefPubMed
9.
go back to reference Saber-Sheikh K, Bryant EC, Glazzard C, Hamel A, Lee RYW. Feasibility of using inertial sensors to assess human movement. Man Ther. 2010;15:122–5.CrossRefPubMed Saber-Sheikh K, Bryant EC, Glazzard C, Hamel A, Lee RYW. Feasibility of using inertial sensors to assess human movement. Man Ther. 2010;15:122–5.CrossRefPubMed
10.
go back to reference Van Remoortel H, Giavedoni S, Raste Y, Burtin C, Louvaris Z, Gieno-Santos E, et al. Validity of activity monitors in health and chronic disease: a systematic review. Int J Behav Nutr Phys Act. 2012;9:84.CrossRefPubMedPubMedCentral Van Remoortel H, Giavedoni S, Raste Y, Burtin C, Louvaris Z, Gieno-Santos E, et al. Validity of activity monitors in health and chronic disease: a systematic review. Int J Behav Nutr Phys Act. 2012;9:84.CrossRefPubMedPubMedCentral
11.
go back to reference Kennedy CA, Beaton DE, Solway S, McConnell S, Bombardier C. Disabilities of the Arm, Shoulder and Hand (DASH). The DASH and QuickDASH outcome measure user’s manual. 3rd ed. Toronto: Institute for Work & Health; 2011. Kennedy CA, Beaton DE, Solway S, McConnell S, Bombardier C. Disabilities of the Arm, Shoulder and Hand (DASH). The DASH and QuickDASH outcome measure user’s manual. 3rd ed. Toronto: Institute for Work & Health; 2011.
12.
go back to reference Lugo K. Bodymedia Inc. 2014, Personal communication. Lugo K. Bodymedia Inc. 2014, Personal communication.
13.
go back to reference Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995;346:1085–7.CrossRefPubMed Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995;346:1085–7.CrossRefPubMed
14.
go back to reference Rettig O, Krautwurst B, Wolf SI. Ex-/internal rotation during bilateral shoulder ab-/adduction and ante-/retroversion movements described as conjunct and adjunct rotation. Rettig O, UniversitatsKlinikum Heidelberg.2014, personal communication. Rettig O, Krautwurst B, Wolf SI. Ex-/internal rotation during bilateral shoulder ab-/adduction and ante-/retroversion movements described as conjunct and adjunct rotation. Rettig O, UniversitatsKlinikum Heidelberg.2014, personal communication.
15.
go back to reference Amasay T, Zodrow K, Kincl L, Hess J, Karduna A. Validation of tri-axial accelerometer for the calculation of elevation angles. Int J Ind Ergon. 2009;39:783–9.CrossRef Amasay T, Zodrow K, Kincl L, Hess J, Karduna A. Validation of tri-axial accelerometer for the calculation of elevation angles. Int J Ind Ergon. 2009;39:783–9.CrossRef
Metadata
Title
Can a physical activity monitor provide a valid measure of arm elevation angle? A study to assess agreement between the SenseWear Mini Armband and the universal goniometer
Authors
Andrew D Hirschhorn
John W Lockhart
John D Breckenridge
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2015
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-015-0507-4

Other articles of this Issue 1/2015

BMC Musculoskeletal Disorders 1/2015 Go to the issue