Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2015

Open Access 01-12-2015 | Research article

Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks

Authors: Satya Pal Sharma, Anders Bærheim, Alice Kvåle

Published in: BMC Musculoskeletal Disorders | Issue 1/2015

Login to get access

Abstract

Background

Measuring range of motion (ROM) in the shoulder joint is important for the diagnosis and monitoring of change over time. To what degree passive ROM can be trusted as a reliable outcome measure was examined as part of an on-going randomized controlled trial for patients with shoulder capsulitis. The aim of this study was to examine intertester reliability of passive ROM in the shoulder joint over a period of eight weeks in patients with adhesive capsulitis stage II.

Methods

Fifty patients with a clinical diagnosis of adhesive shoulder capsulitis were examined by two independent testers. A predefined protocol was used for measuring passive range of motion with an inclinometer, a plurimeter, in both affected and non-affected shoulders three times; at the start of the study and after 4 and 8 weeks.

Results

Very good to excellent intertester agreements were found for most parameters for the affected arm at all three test points. The intraclass correlation coefficient (ICC 2.1) values ranged from 0.76 to 0.98, i.e. from very reliable to excellent. The measurement error was in general small for the affected arm (5°–7°). ICCs were slightly lower for the non-affected arm at 8 weeks, but with acceptable measurement errors.

Conclusions

Intertester reliability between two testers was very good at three visits over a time period of eight weeks using a plurimeter to measure passive range of motion in patients with adhesive shoulder capsulitis. This method can reliably determine passive range of motion in this patient population and be a reliable outcome measure.
Literature
1.
go back to reference Muir SW, Corea CL, Beaupre L. Evaluating change in clinical status: reliability and measures of agreement for the assessment of gleno-humeral range of motion. N Am J Sports Phys Ther. 2010;5:98–110.PubMedPubMedCentral Muir SW, Corea CL, Beaupre L. Evaluating change in clinical status: reliability and measures of agreement for the assessment of gleno-humeral range of motion. N Am J Sports Phys Ther. 2010;5:98–110.PubMedPubMedCentral
2.
go back to reference van der Windt DA, van der Heijden GJ, Scholten RJ, Koes BW, Bouter LM. The efficacy of non-steroidal anti-inflammatory drugs (NSAIDS) for shoulder complaints. A systematic review. J Clin Epidemiol. 1995;48:691–704.CrossRefPubMed van der Windt DA, van der Heijden GJ, Scholten RJ, Koes BW, Bouter LM. The efficacy of non-steroidal anti-inflammatory drugs (NSAIDS) for shoulder complaints. A systematic review. J Clin Epidemiol. 1995;48:691–704.CrossRefPubMed
3.
go back to reference Green S, Buchbinder R, Glazier R, Forbes A. Interventions for shoulder pain. Cochrane Database of Syst Rev. 1999, Issue 2. Art. No.: CD001156. doi: 10.1002/14651858.CD001156. Green S, Buchbinder R, Glazier R, Forbes A. Interventions for shoulder pain. Cochrane Database of Syst Rev. 1999, Issue 2. Art. No.: CD001156. doi: 10.1002/14651858.CD001156.
4.
go back to reference van der Heijden GJ, van der Windt DA, Kleijnen J, Koes BW, Bouter LM. Steroid injections for shoulder disorders: a systematic review of randomized clinical trials. Br J Gen Pract. 1996;46:309–16.PubMedPubMedCentral van der Heijden GJ, van der Windt DA, Kleijnen J, Koes BW, Bouter LM. Steroid injections for shoulder disorders: a systematic review of randomized clinical trials. Br J Gen Pract. 1996;46:309–16.PubMedPubMedCentral
5.
go back to reference Pal B, Anderson J, Dick WC, Griffiths ID. Limitation of joint mobility and shoulder capsulitis in insulin- and non-insulin-dependent diabetes mellitus. Br J Rheumatol. 1986;25:147–51.CrossRefPubMed Pal B, Anderson J, Dick WC, Griffiths ID. Limitation of joint mobility and shoulder capsulitis in insulin- and non-insulin-dependent diabetes mellitus. Br J Rheumatol. 1986;25:147–51.CrossRefPubMed
6.
go back to reference Hannafin JA, Chiaia TA. Adhesive capsulitis. A treatment approach. Clin Orthop Relat Res. 2000;372:95–109.CrossRefPubMed Hannafin JA, Chiaia TA. Adhesive capsulitis. A treatment approach. Clin Orthop Relat Res. 2000;372:95–109.CrossRefPubMed
7.
go back to reference Bunker TD, Anthony PP. The pathology of frozen shoulder. A Dupuytren-like disease. J Bone Joint Surg Br. 1995;77:677–83.PubMed Bunker TD, Anthony PP. The pathology of frozen shoulder. A Dupuytren-like disease. J Bone Joint Surg Br. 1995;77:677–83.PubMed
8.
go back to reference Riddle DL, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting: shoulder measurements. Phys Ther. 1987;67:668–73.PubMed Riddle DL, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting: shoulder measurements. Phys Ther. 1987;67:668–73.PubMed
9.
go back to reference MacDermid JC, Chesworth BM, Patterson S, Roth JH. Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. J Hand Ther. 1999;12:187–92.CrossRefPubMed MacDermid JC, Chesworth BM, Patterson S, Roth JH. Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. J Hand Ther. 1999;12:187–92.CrossRefPubMed
10.
go back to reference Hayes K, Walton JR, Szomor ZR, Murrell GA. Reliability of five methods for assessing shoulder range of motion. Aust J Physiother. 2001;47:289–94.CrossRefPubMed Hayes K, Walton JR, Szomor ZR, Murrell GA. Reliability of five methods for assessing shoulder range of motion. Aust J Physiother. 2001;47:289–94.CrossRefPubMed
11.
go back to reference Kolber MJ, Vega F, Widmayer K, Cheng MS. The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer. Physiother Theory Pract. 2011;27:176–84.CrossRefPubMed Kolber MJ, Vega F, Widmayer K, Cheng MS. The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer. Physiother Theory Pract. 2011;27:176–84.CrossRefPubMed
12.
go back to reference Nadeau S, Kovacs S, Gravel D, Piotte F, Moffet H, Gagnon D, et al. Active movement measurements of the shoulder girdle in healthy subjects with goniometer and tape measure techniques: a study on reliability and validity. Physiother Theory Pract. 2007;23:179–87.CrossRefPubMed Nadeau S, Kovacs S, Gravel D, Piotte F, Moffet H, Gagnon D, et al. Active movement measurements of the shoulder girdle in healthy subjects with goniometer and tape measure techniques: a study on reliability and validity. Physiother Theory Pract. 2007;23:179–87.CrossRefPubMed
13.
go back to reference Mullaney MJ, McHugh MP, Johnson CP, Tyler TF. Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiother Theory Pract. 2010;26:327–33.CrossRefPubMed Mullaney MJ, McHugh MP, Johnson CP, Tyler TF. Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiother Theory Pract. 2010;26:327–33.CrossRefPubMed
14.
go back to reference Sabari JS, Maltzev I, Lubarsky D, Liszkay E, Homel P. Goniometric assessment of shoulder range of motion: comparison of testing in supine and sitting positions. Arch Phys Med Rehabil. 1998;79:647–51.CrossRefPubMed Sabari JS, Maltzev I, Lubarsky D, Liszkay E, Homel P. Goniometric assessment of shoulder range of motion: comparison of testing in supine and sitting positions. Arch Phys Med Rehabil. 1998;79:647–51.CrossRefPubMed
15.
go back to reference Tveita EK, Ekeberg OM, Juel NG, Bautz-Holter E. Range of shoulder motion in patients with adhesive capsulitis; intra-tester reproducibility is acceptable for group comparisons. BMC Musculoskelet Disord. 2008;9:49.CrossRefPubMedPubMedCentral Tveita EK, Ekeberg OM, Juel NG, Bautz-Holter E. Range of shoulder motion in patients with adhesive capsulitis; intra-tester reproducibility is acceptable for group comparisons. BMC Musculoskelet Disord. 2008;9:49.CrossRefPubMedPubMedCentral
16.
go back to reference Green S, Buchbinder R, Forbes A, Bellamy N. A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. Arthritis Care Res. 1998;11:43–52.CrossRefPubMed Green S, Buchbinder R, Forbes A, Bellamy N. A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. Arthritis Care Res. 1998;11:43–52.CrossRefPubMed
17.
go back to reference de Winter AF, Heemskerk MA, Terwee CB, Jans MP, Deville W, van Schaardenburg DJ, et al. Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet Disord. 2004;5:18.CrossRefPubMedPubMedCentral de Winter AF, Heemskerk MA, Terwee CB, Jans MP, Deville W, van Schaardenburg DJ, et al. Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet Disord. 2004;5:18.CrossRefPubMedPubMedCentral
18.
go back to reference de Vet HCW, Terwee CB, Mokkink LB, Knol DL. Measurements in Medicine. Cambridge, U.K: Cambridge University Press; 2011. p. 126–8. de Vet HCW, Terwee CB, Mokkink LB, Knol DL. Measurements in Medicine. Cambridge, U.K: Cambridge University Press; 2011. p. 126–8.
19.
go back to reference Pandya S, Florence JM, King WM, Robison JD, Oxman M, Province MA. Reliability of goniometric measurements in patients with duchenne muscular dystrophy. Phys Ther. 1985;65:1339–42.PubMed Pandya S, Florence JM, King WM, Robison JD, Oxman M, Province MA. Reliability of goniometric measurements in patients with duchenne muscular dystrophy. Phys Ther. 1985;65:1339–42.PubMed
20.
go back to reference Terwee CB, de Winter AF, Scholten RJ, Jans MP, Devillé W, van Schaardenburg D, et al. Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Arch Phys Med Rehabil. 2005;86:1356–61.CrossRefPubMed Terwee CB, de Winter AF, Scholten RJ, Jans MP, Devillé W, van Schaardenburg D, et al. Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Arch Phys Med Rehabil. 2005;86:1356–61.CrossRefPubMed
21.
go back to reference Croft P, Pope D, Boswell R, Rigby A, Silman A. Observer variability in measuring elevation and external rotation of the shoulder. Primary Care Rheumatology Society Shoulder Study Group. Br J Rheumatol. 1994;33:942–6.CrossRefPubMed Croft P, Pope D, Boswell R, Rigby A, Silman A. Observer variability in measuring elevation and external rotation of the shoulder. Primary Care Rheumatology Society Shoulder Study Group. Br J Rheumatol. 1994;33:942–6.CrossRefPubMed
22.
go back to reference Hoving JL, Buchbinder R, Green S, Forbes A, Bellamy N, Brand C, et al. How reliably do rheumatologists measure shoulder movement? Ann Rheum Dis. 2002;61:612–6.CrossRefPubMedPubMedCentral Hoving JL, Buchbinder R, Green S, Forbes A, Bellamy N, Brand C, et al. How reliably do rheumatologists measure shoulder movement? Ann Rheum Dis. 2002;61:612–6.CrossRefPubMedPubMedCentral
23.
go back to reference Awan R, Smith J, Boon AJ. Measuring shoulder internal rotation range of motion: a comparison of 3 techniques. Arch Phys Med Rehabil. 2002;83:1229–34.CrossRefPubMed Awan R, Smith J, Boon AJ. Measuring shoulder internal rotation range of motion: a comparison of 3 techniques. Arch Phys Med Rehabil. 2002;83:1229–34.CrossRefPubMed
24.
go back to reference de Jong LD, Dijkstra PU, Stewart RE, Postema K. Repeated measurements of arm joint passive range of motion after stroke: interobserver reliability and sources of variation. Phys Ther. 2012;92:1027–35.CrossRefPubMed de Jong LD, Dijkstra PU, Stewart RE, Postema K. Repeated measurements of arm joint passive range of motion after stroke: interobserver reliability and sources of variation. Phys Ther. 2012;92:1027–35.CrossRefPubMed
27.
28.
go back to reference Ginn KA, Cohen ML, Herbert RD. Does hand-behind-back range of motion accurately reflect shoulder internal rotation? J Shoulder Elbow Surg. 2006;15:311–4.CrossRefPubMed Ginn KA, Cohen ML, Herbert RD. Does hand-behind-back range of motion accurately reflect shoulder internal rotation? J Shoulder Elbow Surg. 2006;15:311–4.CrossRefPubMed
29.
go back to reference Wakabayashi I, Itoi E, Minagawa H, Kobayashi M, Seki N, Shimada Y, et al. Does reaching the back reflect the actual internal rotation of the shoulder? J Shoulder Elbow Surg. 2006;15:306–10.CrossRefPubMed Wakabayashi I, Itoi E, Minagawa H, Kobayashi M, Seki N, Shimada Y, et al. Does reaching the back reflect the actual internal rotation of the shoulder? J Shoulder Elbow Surg. 2006;15:306–10.CrossRefPubMed
30.
go back to reference Eliasziw M, Young SL, Woodbury MG, Fryday-Field K. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther. 1994;74:777–88.PubMed Eliasziw M, Young SL, Woodbury MG, Fryday-Field K. Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. Phys Ther. 1994;74:777–88.PubMed
32.
go back to reference Stokes EK. Rehabilitation outcome measures. 1st ed. Edinburgh; New York: Churchill Livingstone; 2011. p. 27–32.CrossRef Stokes EK. Rehabilitation outcome measures. 1st ed. Edinburgh; New York: Churchill Livingstone; 2011. p. 27–32.CrossRef
33.
go back to reference Musselman K. Clinical significance testing in rehabilitation research: what, why, and how? Phys Ther Rev. 2007;12:287–96.CrossRef Musselman K. Clinical significance testing in rehabilitation research: what, why, and how? Phys Ther Rev. 2007;12:287–96.CrossRef
34.
go back to reference Ombregt L, Bisschop P, Veer HJ, Van de Velde T. A System of orthopaedic medicine. London: Saunders; 1995. Ombregt L, Bisschop P, Veer HJ, Van de Velde T. A System of orthopaedic medicine. London: Saunders; 1995.
35.
go back to reference Shaffer B, Tibone JE, Kerlan RK. Frozen shoulder. A long-term follow-up. J Bone Joint Surg Am. 1992;74:738–46.PubMed Shaffer B, Tibone JE, Kerlan RK. Frozen shoulder. A long-term follow-up. J Bone Joint Surg Am. 1992;74:738–46.PubMed
36.
go back to reference Gajdosik RL, Bohannon RW. Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther. 1987;67:1867–72.PubMed Gajdosik RL, Bohannon RW. Clinical measurement of range of motion: review of goniometry emphasizing reliability and validity. Phys Ther. 1987;67:1867–72.PubMed
37.
go back to reference Fish DR, Wingate L. Sources of goniometric error at the elbow. Phys Ther. 1985;65:1666–70.PubMed Fish DR, Wingate L. Sources of goniometric error at the elbow. Phys Ther. 1985;65:1666–70.PubMed
Metadata
Title
Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks
Authors
Satya Pal Sharma
Anders Bærheim
Alice Kvåle
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2015
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-015-0495-4

Other articles of this Issue 1/2015

BMC Musculoskeletal Disorders 1/2015 Go to the issue