Skip to main content
Top
Published in: BMC Pediatrics 1/2019

Open Access 01-12-2019 | Ultrasound | Research article

Ultrasound of the infant hip: manual fixation is equivalent to Graf’s technique regarding image quality—a randomized trial

Authors: Peter Voitl, Christian Sebelefsky, Sara Hosner, Astrid Woditschka, Susanne Diesner, Andreas Böck

Published in: BMC Pediatrics | Issue 1/2019

Login to get access

Abstract

Background

In Middle Europe ultrasonography is the standard method used to screen for developmental dysplasia of the hip in infants. Our aim was to determine whether manual fixation of the child is equivalent to Graf’s technique regarding image quality.

Methods

This randomized trial was conducted at a free-standing general pediatric outpatient clinic in Vienna, Austria. Healthy infants in the 1st and between the 6th and 8th week of life with no hip malalignment were included. After randomization, Group 1 was examined using Graf’s fixation device and participants in Group 2 were fixated on the examination couch by their parents. In a second step, all images underwent a blinded evaluation.

Results

A total of 117 babies (Group 1: n = 62, Group 2: n = 54, excluded: n = 1) were examined and 230 images (Group 1: n = 122, Group 2: n = 108) were evaluated, of which 225 were sonographically normal. Two images, showing a type IIa right hip and a type IIa + left hip respectively, were excluded. One participant had to be excluded as the respective images showed two pathologic hip joints. Two images in Group 1 and three in Group 2 were not evaluable. No statistical association between image quality (11 quality criteria and overall evaluability) and fixation technique (0.12 ≤ p ≤ 1.0 or constant) was found.

Conclusions

Considering sonographically normal hip joints, we found no evidence that manual fixation differed from Graf’s technique regarding image quality. In future studies, hip pathologies should be included and discomfort of infants and parents during the examination should be addressed.

Trial registration

German Clinical Trials Register, ID: DRKS00015694), registered retrospectively on October 7th, 2018.
Literature
1.
go back to reference Dogruel H, Atalar H, Yavuz OY, Sayli U. Clinical examination versus ultrasonography in detecting developmental dysplasia of the hip. Int Orthop. 2008;32(3):415–9.CrossRef Dogruel H, Atalar H, Yavuz OY, Sayli U. Clinical examination versus ultrasonography in detecting developmental dysplasia of the hip. Int Orthop. 2008;32(3):415–9.CrossRef
2.
go back to reference Graf R, Lercher K, Tschauner C, Baumgartner F, Plattner F: Sonographie der Säuglingshüfte und therapeutische Konsequenzen. Ein Kompendium, 6th edn: Georg Thieme Verlag KG; 2010. Graf R, Lercher K, Tschauner C, Baumgartner F, Plattner F: Sonographie der Säuglingshüfte und therapeutische Konsequenzen. Ein Kompendium, 6th edn: Georg Thieme Verlag KG; 2010.
3.
go back to reference Harcke HT, Clarke NM, Lee MS, Borns PF, MacEwen GD. Examination of the infant hip with real-time ultrasonography. J Ultrasound Med. 1984;3(3):131–7.CrossRef Harcke HT, Clarke NM, Lee MS, Borns PF, MacEwen GD. Examination of the infant hip with real-time ultrasonography. J Ultrasound Med. 1984;3(3):131–7.CrossRef
4.
go back to reference Thaler M, Biedermann R, Lair J, Krismer M, Landauer F. Cost-effectiveness of universal ultrasound screening compared with clinical examination alone in the diagnosis and treatment of neonatal hip dysplasia in Austria. J Bone Joint Surg Br. 2011;93(8):1126–30.CrossRef Thaler M, Biedermann R, Lair J, Krismer M, Landauer F. Cost-effectiveness of universal ultrasound screening compared with clinical examination alone in the diagnosis and treatment of neonatal hip dysplasia in Austria. J Bone Joint Surg Br. 2011;93(8):1126–30.CrossRef
5.
go back to reference von Kries R, Ihme N, Oberle D, Lorani A, Stark R, Altenhofen L, Niethard FU. Effect of ultrasound screening on the rate of first operative procedures for developmental hip dysplasia in Germany. Lancet. 2003;362(9399):1883–7.CrossRef von Kries R, Ihme N, Oberle D, Lorani A, Stark R, Altenhofen L, Niethard FU. Effect of ultrasound screening on the rate of first operative procedures for developmental hip dysplasia in Germany. Lancet. 2003;362(9399):1883–7.CrossRef
6.
go back to reference von Kries R, Ihme N, Altenhofen L, Niethard FU, Krauspe R, Ruckinger S. General ultrasound screening reduces the rate of first operative procedures for developmental dysplasia of the hip: a case-control study. J Pediatr. 2012;160(2):271–5.CrossRef von Kries R, Ihme N, Altenhofen L, Niethard FU, Krauspe R, Ruckinger S. General ultrasound screening reduces the rate of first operative procedures for developmental dysplasia of the hip: a case-control study. J Pediatr. 2012;160(2):271–5.CrossRef
7.
go back to reference Wirth T, Stratmann L, Hinrichs F. Evolution of late presenting developmental dysplasia of the hip and associated surgical procedures after 14 years of neonatal ultrasound screening. J Bone Joint Surg Br. 2004;86(4):585–9.CrossRef Wirth T, Stratmann L, Hinrichs F. Evolution of late presenting developmental dysplasia of the hip and associated surgical procedures after 14 years of neonatal ultrasound screening. J Bone Joint Surg Br. 2004;86(4):585–9.CrossRef
8.
go back to reference Rosendahl K, Dezateux C, Fosse KR, Aase H, Aukland SM, Reigstad H, Alsaker T, Moster D, Lie RT, Markestad T. Immediate treatment versus sonographic surveillance for mild hip dysplasia in newborns. Pediatrics. 2010;125(1):e9–16.CrossRef Rosendahl K, Dezateux C, Fosse KR, Aase H, Aukland SM, Reigstad H, Alsaker T, Moster D, Lie RT, Markestad T. Immediate treatment versus sonographic surveillance for mild hip dysplasia in newborns. Pediatrics. 2010;125(1):e9–16.CrossRef
9.
go back to reference Peterlein CD, Fuchs-Winkelmann S. Paediatric hip sonography: current status at German university hospitals. Orthopade. 2014;43(2):136–42.CrossRef Peterlein CD, Fuchs-Winkelmann S. Paediatric hip sonography: current status at German university hospitals. Orthopade. 2014;43(2):136–42.CrossRef
10.
go back to reference Heeres RH, Witbreuk MM, van der Sluijs JA. Diagnosis and treatment of developmental dysplasia of the hip in the Netherlands: national questionnaire of paediatric orthopaedic surgeons on current practice in children less than 1 year old. J Child Orthop. 2011;5(4):267–71.CrossRef Heeres RH, Witbreuk MM, van der Sluijs JA. Diagnosis and treatment of developmental dysplasia of the hip in the Netherlands: national questionnaire of paediatric orthopaedic surgeons on current practice in children less than 1 year old. J Child Orthop. 2011;5(4):267–71.CrossRef
11.
go back to reference Rendi-Wagner P: Mutter-Kind-Pass, 2012 edn. Vienna, Austria: Bundesministerium für Gesundheit (BMG); 2012. Rendi-Wagner P: Mutter-Kind-Pass, 2012 edn. Vienna, Austria: Bundesministerium für Gesundheit (BMG); 2012.
12.
go back to reference Graf R. The diagnosis of congenital hip-joint dislocation by the ultrasonic Combound treatment. Arch Orthop Trauma Surg. 1980;97(2):117–33.CrossRef Graf R. The diagnosis of congenital hip-joint dislocation by the ultrasonic Combound treatment. Arch Orthop Trauma Surg. 1980;97(2):117–33.CrossRef
13.
go back to reference Graf R, Baumgartner F, Lercher K: Ultraschalldiagnostik der Säuglingshüfte: Ein Atlas, 2nd edn: Springer Medizin Verlag Heidelberg; 2011. Graf R, Baumgartner F, Lercher K: Ultraschalldiagnostik der Säuglingshüfte: Ein Atlas, 2nd edn: Springer Medizin Verlag Heidelberg; 2011.
14.
go back to reference Graf R. Hip sonography: diagnosis and Management of Infant hip Dysplasia. 2nd ed. Berlin Heidelberg: Springer-Verlag; 2006. Graf R. Hip sonography: diagnosis and Management of Infant hip Dysplasia. 2nd ed. Berlin Heidelberg: Springer-Verlag; 2006.
17.
go back to reference Graf R, Mohajer M, Plattner F. Hip sonography update. Quality-management, catastrophes - tips and tricks. Med Ultrason. 2013;15(4):299–303.CrossRef Graf R, Mohajer M, Plattner F. Hip sonography update. Quality-management, catastrophes - tips and tricks. Med Ultrason. 2013;15(4):299–303.CrossRef
18.
go back to reference Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149–60.CrossRef Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149–60.CrossRef
Metadata
Title
Ultrasound of the infant hip: manual fixation is equivalent to Graf’s technique regarding image quality—a randomized trial
Authors
Peter Voitl
Christian Sebelefsky
Sara Hosner
Astrid Woditschka
Susanne Diesner
Andreas Böck
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Pediatrics / Issue 1/2019
Electronic ISSN: 1471-2431
DOI
https://doi.org/10.1186/s12887-019-1392-z

Other articles of this Issue 1/2019

BMC Pediatrics 1/2019 Go to the issue