Skip to main content
Top
Published in: BMC Ophthalmology 1/2020

Open Access 01-12-2020 | Research article

The impact of irregular corneal shape parameters on visual acuity and contrast sensitivity

Authors: Sanita Liduma, Artis Luguzis, Gunta Krumina

Published in: BMC Ophthalmology | Issue 1/2020

Login to get access

Abstract

Background

To understand which irregular corneal parameters determine the visual quality in keratoconus subjects.

Methods

The cross-sectional study examined the eyes of 44 subjects, graded from the first to third keratoconus stages by Amsler-Krumeich classification. We obtained measurements in two ways: (a) by projecting two perpendicular axes onto a cornea (first, through the central point of the cornea and keratoconus apex; second, as the perpendicular axis) to read the elevation values at points on these axes as parameters characterising the corneal surface; (b) by projecting circles with different diameters around the central part of the cornea (1, 2, and 3 mm) and reading elevation values at points equally displaced on these circles as parameters characterising an anterior surface slope. Irregular corneal shape parameters’ correlations with visual acuity and contrast sensitivity were determined in order to understand which corneal slope parameter has the strongest correlation with visual acuity and contrast sensitivity.

Results

Parameters characterising the corneal surface’s correlations with contrast sensitivity were from r = 0.25 (p = 0.03) at 3 cpd to r = 0.47 (p < 0.01) at 9 cpd for the highest elevation and from r = 0.33 (p = 0.09) at 5 cpd to r = 0.40 (p < 0.01) at 11 cpd for the lowest elevation in all subjects together, while for visual acuity the parameters were r = 0.30 (p < 0.01) for the highest elevation and r = 0.21 (p = 0.06) for the lowest elevation in all subjects together. The correlation between contrast sensitivity and the highest and lowest corneal point in all measured cornea was stronger for subjects with a peripheral corneal apex than for those with a central apex. In keratoconus subjects, contrast sensitivity displayed a strong correlation with slope in the central part of the cornea (with a radius of 1 mm) ranging from 0.48 (p < 0.01) at 3 cpd to 0.61 (p < 0.01) at 9 cpd.

Conclusion

Contrast sensitivity has a higher correlation with corneal shape parameters than with visual acuity. Subjects with a peripheral corneal apex had stronger correlations with visual acuity and contrast sensitivity than did subjects with a central apex. In keratoconus subjects, the strongest correlation was for contrast sensitivity and elevation (slope) in the region within a 1 mm radius of the corneal centre in the opposite direction of the keratoconus apex (direction (ax) CB).
Footnotes
1
The study focused on absolute values of correlations rather than their positive or negative values.
 
Literature
7.
go back to reference Klyce SD. Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy. Invest Ophthalmol Vis Sci. 1984;25:1426–35 PMID: 6511226.PubMed Klyce SD. Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy. Invest Ophthalmol Vis Sci. 1984;25:1426–35 PMID: 6511226.PubMed
9.
go back to reference Maeda N, Sato S, Watanabe H, Inoue Y, Fujikado T, Shimomura Y, Tano Y. Prediction of letter contrast sensitivity using videokeratographic indices. Am J Ophthalmol. 2000;129:759–63. 8528916.CrossRef Maeda N, Sato S, Watanabe H, Inoue Y, Fujikado T, Shimomura Y, Tano Y. Prediction of letter contrast sensitivity using videokeratographic indices. Am J Ophthalmol. 2000;129:759–63. 8528916.CrossRef
10.
go back to reference Zadnik K, Barr JT, Edrington TB, Nichols JJ, Wilson BS, Siegmund K, Gordon MO. Corneal scarring and vision in Keratoconus. A Baseline Report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Cornea. 2000;19:804–12 PMID:9894935.PubMed Zadnik K, Barr JT, Edrington TB, Nichols JJ, Wilson BS, Siegmund K, Gordon MO. Corneal scarring and vision in Keratoconus. A Baseline Report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Cornea. 2000;19:804–12 PMID:9894935.PubMed
12.
go back to reference Hess RF, Carney LG. Vision through an abnormal cornea: a pilot study of the relationship between visual loss from corneal distortion, corneal edema, keratoconus, and some allied corneal pathology. Invest Ophthalmol Vis Sci. 1978;18:476–83. Hess RF, Carney LG. Vision through an abnormal cornea: a pilot study of the relationship between visual loss from corneal distortion, corneal edema, keratoconus, and some allied corneal pathology. Invest Ophthalmol Vis Sci. 1978;18:476–83.
13.
go back to reference Zadnik K, Mannis MJ, Johnson CA. An analysis of contrast sensitivity in identical twins with Keratoconus. Cornea. 1984;3:99–103 PMID: 6399238.CrossRef Zadnik K, Mannis MJ, Johnson CA. An analysis of contrast sensitivity in identical twins with Keratoconus. Cornea. 1984;3:99–103 PMID: 6399238.CrossRef
16.
go back to reference Barbero S, Marcos S, Merayo-Lloves L, Moreno-Barriuso E. Validation of the estimation of corneal aberrations from Videokeratography in Keratoconus. J Refract Surg. 2002;18:263–70 PMID:12051382.PubMed Barbero S, Marcos S, Merayo-Lloves L, Moreno-Barriuso E. Validation of the estimation of corneal aberrations from Videokeratography in Keratoconus. J Refract Surg. 2002;18:263–70 PMID:12051382.PubMed
19.
go back to reference Douglas GB, Wright AT. Sample size requirements for estimating Pearson, Kendall and spearman correlations. Psychometrika. 2000;65(1):23–8.CrossRef Douglas GB, Wright AT. Sample size requirements for estimating Pearson, Kendall and spearman correlations. Psychometrika. 2000;65(1):23–8.CrossRef
21.
go back to reference Liduma S, Luguzis A, Krumina G. The impact of keratoconus apex’s slope on visual acuity and contrast sensitivity. Abstractband DOG 2019 Der. Ophthalmologe. 2019;116:25–218.CrossRef Liduma S, Luguzis A, Krumina G. The impact of keratoconus apex’s slope on visual acuity and contrast sensitivity. Abstractband DOG 2019 Der. Ophthalmologe. 2019;116:25–218.CrossRef
22.
go back to reference Paranhos JFS, Paranhos A Jr, Avila MP, Schor P. Analysis of the correlations between ophthalmic examination and quality of life outcomes following intracorneal ring segment implantation for keratoconus. Arq Bras Oftalmol. 2011;74:410–3.CrossRef Paranhos JFS, Paranhos A Jr, Avila MP, Schor P. Analysis of the correlations between ophthalmic examination and quality of life outcomes following intracorneal ring segment implantation for keratoconus. Arq Bras Oftalmol. 2011;74:410–3.CrossRef
Metadata
Title
The impact of irregular corneal shape parameters on visual acuity and contrast sensitivity
Authors
Sanita Liduma
Artis Luguzis
Gunta Krumina
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2020
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-020-01737-x

Other articles of this Issue 1/2020

BMC Ophthalmology 1/2020 Go to the issue