Background

To report the negative effect of Nd: Yag (Neodymium-doped: Yttrium Aluminium Garnet) laser capsulotomy on the intraocular pressure (IOP) and the trabeculectomy bleb integrity, in a small series of eyes, both trabeculectomised and pseudophakic, following the laser application for the management of posterior capsular opacification (PCO).

Methods

This is a retrospective, non-comparative interventional case series study, in which 20 trabeculectomised and pseudophakic eyes from 15 patients, with otherwise well functioning blebs, were presented with uncontrolled IOP, in a variable distance of time following the application of YAG laser capsulotomy. Student paired t-test confirmed a statistically significant difference (P < 0.05) between IOP before Nd: YAG laser capsulotomy (16 mmHg ± 3 mmHg) and the respective one, 2 to 6 months after Nd: Yag capsulotomy (34.5 ± 11 mmHg).

Results

All of the cases failed to respond to conservative treatment and were successfully managed with the implantation of Ahmed drainage devices. All patients showed flat filtering bleb and uncontrolled IOP (34.5 ± 11 mmHg), under maximum topical treatment, in a period of 2 to 6 months following Nd: YAG laser caspulotomy. The implantation of Ahmed valve proved to be effective treatment for these patients (IOP < 21 mmHg).

Conclusions

Although Nd: Yag laser capsulotomy is considered a safe surgical procedure and usually is done without second thought, in this series of eyes, it is postulated that it may be responsible for the deregulation of the filtering bleb and subsequent loss of IOP control. We consider that laser capsulotomy should be performed with caution, especially in eyes with previous trabeculectomy. Also close monitoring of the intraocular pressure and assessment of eventual bleb morphology variations in the follow-up period is mandatory. Further studies are needed in order to confirm our findings.
Literature
1.
go back to reference Barnes EA, Murdoch IE, Subramaniam S, et al. Neodymium:yttrium-aluminum-garnet capsulotomy and intraocular pressure in pseudophakic patients with glaucoma. Ophthalmology. 2004;111(7):1393–7.CrossRefPubMed Barnes EA, Murdoch IE, Subramaniam S, et al. Neodymium:yttrium-aluminum-garnet capsulotomy and intraocular pressure in pseudophakic patients with glaucoma. Ophthalmology. 2004;111(7):1393–7.CrossRefPubMed
2.
go back to reference Schaumberg DA, Dana MR, Christen WG, et al. A systematic overview of the incidence of posterior capsule opacification. Ophthalmology. 1998;105(7):1213–21.CrossRefPubMed Schaumberg DA, Dana MR, Christen WG, et al. A systematic overview of the incidence of posterior capsule opacification. Ophthalmology. 1998;105(7):1213–21.CrossRefPubMed
3.
go back to reference Sundelin K, Sjostrand J. Posterior capsule opacification 5 years after extracapsular cataract extraction. J Cataract Refract Surg. 1999;25(2):246–50.CrossRefPubMed Sundelin K, Sjostrand J. Posterior capsule opacification 5 years after extracapsular cataract extraction. J Cataract Refract Surg. 1999;25(2):246–50.CrossRefPubMed
4.
go back to reference Channell MM, Beckman H. Intraocular pressure changes after neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1984;102(7):1024–6.CrossRefPubMed Channell MM, Beckman H. Intraocular pressure changes after neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1984;102(7):1024–6.CrossRefPubMed
5.
go back to reference Slomovic AR, Parrish 2nd RK. Acute elevations of intraocular pressure following Nd: YAG laser posterior capsulotomy. Ophthalmology. 1985;92(7):973–6.CrossRefPubMed Slomovic AR, Parrish 2nd RK. Acute elevations of intraocular pressure following Nd: YAG laser posterior capsulotomy. Ophthalmology. 1985;92(7):973–6.CrossRefPubMed
6.
go back to reference Ge J, Wand M, Chiang R, et al. Long-term effect of Nd: YAG laser posterior capsulotomy on intraocular pressure. Arch Ophthalmol. 2000;118(10):1334–7.CrossRefPubMed Ge J, Wand M, Chiang R, et al. Long-term effect of Nd: YAG laser posterior capsulotomy on intraocular pressure. Arch Ophthalmol. 2000;118(10):1334–7.CrossRefPubMed
7.
go back to reference Leys MJ, Pameijer JH, de Jong PT. Intermediate-term changes in intraocular pressure after neodymium-YAG laser posterior capsulotomy. Am J Ophthalmol. 1985;100(2):332–3.CrossRefPubMed Leys MJ, Pameijer JH, de Jong PT. Intermediate-term changes in intraocular pressure after neodymium-YAG laser posterior capsulotomy. Am J Ophthalmol. 1985;100(2):332–3.CrossRefPubMed
8.
go back to reference Fourman S, Apisson J. Late-onset elevation in intraocular pressure after neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1991;109(4):511–3.CrossRefPubMed Fourman S, Apisson J. Late-onset elevation in intraocular pressure after neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1991;109(4):511–3.CrossRefPubMed
9.
go back to reference Zeyen P, Zeyen T. The long-term effect of Yag laser posterior capsulotomy on intraocular pressure after combined glaucoma and cataract surgery. Bull Soc Belge Ophtalmol. 1999;271:99–103.PubMed Zeyen P, Zeyen T. The long-term effect of Yag laser posterior capsulotomy on intraocular pressure after combined glaucoma and cataract surgery. Bull Soc Belge Ophtalmol. 1999;271:99–103.PubMed
10.
go back to reference Lin JC, Katz LJ, Spaeth GL, Klancnik Jr JM. Intraocular pressure control after Nd: YAG laser posterior capsulotomy in eyes with glaucoma. Br J Ophthalmol. 2008;92(3):337–9.CrossRefPubMed Lin JC, Katz LJ, Spaeth GL, Klancnik Jr JM. Intraocular pressure control after Nd: YAG laser posterior capsulotomy in eyes with glaucoma. Br J Ophthalmol. 2008;92(3):337–9.CrossRefPubMed
11.
go back to reference Stark WJ, Worthen D, Holladay JT, Murray G. Neodymium: YAG lasers. An FDA report. Ophthalmology. 1985;92(2):209–12.CrossRefPubMed Stark WJ, Worthen D, Holladay JT, Murray G. Neodymium: YAG lasers. An FDA report. Ophthalmology. 1985;92(2):209–12.CrossRefPubMed
12.
go back to reference Richter CU, Arzeno G, Pappas HR, Steinert RF, Puliafito C, Epstein DL. Intraocular pressure elevation following Nd: YAG laser posterior capsulotomy. Ophthalmology. 1985;92(5):636–40.CrossRefPubMed Richter CU, Arzeno G, Pappas HR, Steinert RF, Puliafito C, Epstein DL. Intraocular pressure elevation following Nd: YAG laser posterior capsulotomy. Ophthalmology. 1985;92(5):636–40.CrossRefPubMed
13.
go back to reference Steinert RF, Puliafito CA, Kumar SR, Dudak SD, Patel S. Cystoid macular edema, retinal detachment, and glaucoma after Nd: YAG laser posterior capsulotomy. Am J Ophthalmol. 1991;112(4):373–80.CrossRefPubMed Steinert RF, Puliafito CA, Kumar SR, Dudak SD, Patel S. Cystoid macular edema, retinal detachment, and glaucoma after Nd: YAG laser posterior capsulotomy. Am J Ophthalmol. 1991;112(4):373–80.CrossRefPubMed
14.
go back to reference Jahn CE, Emke M. Long-term elevation of intraocular pressure after neodymium: YAG laser posterior capsulotomy. Ophthalmologica. 1996;210(2):85–9.CrossRefPubMed Jahn CE, Emke M. Long-term elevation of intraocular pressure after neodymium: YAG laser posterior capsulotomy. Ophthalmologica. 1996;210(2):85–9.CrossRefPubMed
15.
go back to reference Ladas ID, Baltatzis S, Panagiotidis D, et al. Topical 2.0% dorzolamide vs oral acetazolamide for prevention of intraocular pressure rise after neodymium: YAG laser capsulotomy. Arch Ophthalmol. 1997;115:1241–4.CrossRefPubMed Ladas ID, Baltatzis S, Panagiotidis D, et al. Topical 2.0% dorzolamide vs oral acetazolamide for prevention of intraocular pressure rise after neodymium: YAG laser capsulotomy. Arch Ophthalmol. 1997;115:1241–4.CrossRefPubMed
16.
go back to reference Karahan E, Er D, et al. An overview of Nd; YAG Laser Capsulotomy. Med Hypothesis Discov Innov Ophthalmol. 2014;3(2):45–50.PubMedPubMedCentral Karahan E, Er D, et al. An overview of Nd; YAG Laser Capsulotomy. Med Hypothesis Discov Innov Ophthalmol. 2014;3(2):45–50.PubMedPubMedCentral
Metadata
Title
Bleb failure and intraocular pressure rise following Nd: Yag laser capsulotomy
Authors
Andreas Diagourtas
Petros Petrou
Ilias Georgalas
Kostantinos Oikonomakis
Panagiotis Giannakouras
Athanasios Vergados
Dimitrios Papaconstantinou
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2017
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-017-0408-4

Other articles of this Issue 1/2017

BMC Ophthalmology 1/2017 Go to the issue