Published in: BMC Pregnancy and Childbirth 1/2020

Open Access 01-12-2020 | Research article

Effect of nipple shield use on milk removal: a mechanistic study

Authors: Viviane Silva Coentro, Sharon Lisa Perrella, Ching Tat Lai, Alethea Rea, Kevin Murray, Donna Tracy Geddes

Published in: BMC Pregnancy and Childbirth | Issue 1/2020

Login to get access

Abstract

Background

Concerns about reduced milk transfer with nipple shield (NS) use are based on evidence from studies with methodological flaws. Milk removal during breastfeeding can be impacted by infant and maternal factors other than NS use. The aim of this study was to control electric breast pump vacuum strength, pattern and duration across multiple study sessions to determine if NS use reduces milk removal from the breast.

Methods

A within-subject study with two groups of breastfeeding mothers (infants < 6 months) were recruited; Control Group (CG): no breastfeeding difficulties; Pain Group (PG) used NS for persistent nipple pain. Mothers completed three randomised 15 min pumping sessions using the Symphony vacuum curve (Medela AG); no NS, fitted NS, and a small NS. Sessions were considered valid where the applied vacuum was within 20 mmHg of the set vacuum. Milk removal was considered as pumped milk volume, and also percentage of available milk removed (PAMR), which is calculated as the pumped volume divided by the estimated milk volume stored in the breast immediately prior to pumping.

Results

Of 62 sessions (all: n = 31 paired sessions) a total of 11 paired sessions from both PG (n = 03) and CG (n = 08) were valid (subset) with and without a fitted NS. Only 2 small shield sessions were valid and so all small shield measurements were excluded. Both pumped volumes and PAMR were significantly lower with NS use for all data but not for subset data. (All: Volume and PAMR median: no NS: 76.5 mL, 69%, Fitted NS: 32.1 mL, 41% respectively (volume p = 0.002, PAMR p = 0.002); Subset: Volume and PAMR median: no NS: 83.8 mL, 72%; Fitted NS: 35.2 mL, 40% (volume p = 0.111 and PAMR p = 0.045). The difference in PAMR, but not volume, was statistically significant when analysed by linear mixed modelling. A decrease of 10 mmHg was associated with a 4.4% increase in PAMR (p = 0.017).

Conclusions

This experimental data suggests that nipple shield use may reduce milk removal. Close clinical monitoring of breastfeeding mothers using nipple shields is warranted.
Literature
1.
go back to reference Schwartz K, D’Arcy HJ, Gillespie B, Bobo J, Longeway M, Foxman B. Factors associated with weaning in the first 3 months postpartum. J Fam Pract. 2002;51(5):439–44.PubMed Schwartz K, D’Arcy HJ, Gillespie B, Bobo J, Longeway M, Foxman B. Factors associated with weaning in the first 3 months postpartum. J Fam Pract. 2002;51(5):439–44.PubMed
2.
go back to reference Riordan J, Bibb D, Miller M, Rawlins T. Predicting breastfeeding duration using the LATCH breastfeeding assessment tool. J Hum Lact. 2001;17(1):20–3.CrossRef Riordan J, Bibb D, Miller M, Rawlins T. Predicting breastfeeding duration using the LATCH breastfeeding assessment tool. J Hum Lact. 2001;17(1):20–3.CrossRef
3.
go back to reference Berens P, Eglash A, Malloy M, Steube AM. ABM Clinical Protocol #26: Persistent Pain with Breastfeeding. Breastfeed Med. 2016;11:46–53. Berens P, Eglash A, Malloy M, Steube AM. ABM Clinical Protocol #26: Persistent Pain with Breastfeeding. Breastfeed Med. 2016;11:46–53.
4.
go back to reference Odom EC, Li R, Scanlon KS, Perrine CG, Grummer-Strawn L. Reasons for earlier than desired cessation of breastfeeding. Pediatrics. 2013;131(3):e726-32.CrossRef Odom EC, Li R, Scanlon KS, Perrine CG, Grummer-Strawn L. Reasons for earlier than desired cessation of breastfeeding. Pediatrics. 2013;131(3):e726-32.CrossRef
5.
go back to reference McClellan HL, Hepworth AR, Kent JC, Garbin CP, Williams TM, Hartmann PE, et al. Breastfeeding frequency, milk volume, and duration in mother-infant dyads with persistent nipple pain. Breastfeed Med. 2012;7:275–81. McClellan HL, Hepworth AR, Kent JC, Garbin CP, Williams TM, Hartmann PE, et al. Breastfeeding frequency, milk volume, and duration in mother-infant dyads with persistent nipple pain. Breastfeed Med. 2012;7:275–81.
6.
go back to reference Kent JC, Ashton E, Hardwick CM, Rowan MK, Chia ES, Fairclough KA, et al. Nipple Pain in Breastfeeding Mothers: Incidence, Causes and Treatments. Int J Environ Res Public Health. 2015;12(10):12247–63. Kent JC, Ashton E, Hardwick CM, Rowan MK, Chia ES, Fairclough KA, et al. Nipple Pain in Breastfeeding Mothers: Incidence, Causes and Treatments. Int J Environ Res Public Health. 2015;12(10):12247–63.
7.
go back to reference McClellan H, Geddes D, Kent J, Garbin C, Mitoulas L, Hartmann P. Infants of mothers with persistent nipple pain exert strong sucking vacuums. Acta Paediatr. 2008;97(9):1205–9.CrossRef McClellan H, Geddes D, Kent J, Garbin C, Mitoulas L, Hartmann P. Infants of mothers with persistent nipple pain exert strong sucking vacuums. Acta Paediatr. 2008;97(9):1205–9.CrossRef
8.
go back to reference McClellan HL, Hepworth AR, Garbin CP, Rowan MK, Deacon J, Hartmann PE, et al. Nipple pain during breastfeeding with or without visible trauma. J Hum Lact. 2012;28(4):511–21. McClellan HL, Hepworth AR, Garbin CP, Rowan MK, Deacon J, Hartmann PE, et al. Nipple pain during breastfeeding with or without visible trauma. J Hum Lact. 2012;28(4):511–21.
9.
go back to reference Chow S, Chow R, Popovic M, Lam H, Merrick J, Ventegodt S, et al. The Use of Nipple Shields: A Review. Front Public Health. 2015;3:236. Chow S, Chow R, Popovic M, Lam H, Merrick J, Ventegodt S, et al. The Use of Nipple Shields: A Review. Front Public Health. 2015;3:236.
10.
go back to reference Chertok IR. Reexamination of ultra-thin nipple shield use, infant growth and maternal satisfaction. J Clin Nurs. 2009;18(21):2949–55. Chertok IR. Reexamination of ultra-thin nipple shield use, infant growth and maternal satisfaction. J Clin Nurs. 2009;18(21):2949–55.
11.
go back to reference Powers D, Tapia VB. Women’s experiences using a nipple shield. J Hum Lact. 2004;20(3):327–34. Powers D, Tapia VB. Women’s experiences using a nipple shield. J Hum Lact. 2004;20(3):327–34.
12.
go back to reference Woolridge MW, Baum JD, Drewett RF. Effect of a traditional and of a new nipple shield on sucking patterns and milk flow. Early Hum Dev. 1980;4(4):357–64.CrossRef Woolridge MW, Baum JD, Drewett RF. Effect of a traditional and of a new nipple shield on sucking patterns and milk flow. Early Hum Dev. 1980;4(4):357–64.CrossRef
13.
go back to reference Brigham M. Mothers’ reports of the outcome of nipple shield use. J Hum Lact. 1996;12(4):291–7. Brigham M. Mothers’ reports of the outcome of nipple shield use. J Hum Lact. 1996;12(4):291–7.
14.
go back to reference Pincombe J, Baghurst P, Antoniou G, Peat B, Henderson A, Reddin E. Baby Friendly Hospital Initiative practices and breast feeding duration in a cohort of first-time mothers in Adelaide, Australia. Midwifery. 2008;24(1):55–61.CrossRef Pincombe J, Baghurst P, Antoniou G, Peat B, Henderson A, Reddin E. Baby Friendly Hospital Initiative practices and breast feeding duration in a cohort of first-time mothers in Adelaide, Australia. Midwifery. 2008;24(1):55–61.CrossRef
15.
go back to reference Eglash A, Ziemer AL, Chevalier A. Health professionals’ attitudes and use of nipple shields for breastfeeding women. Breastfeed Med. 2010;5(4):147–51. Eglash A, Ziemer AL, Chevalier A. Health professionals’ attitudes and use of nipple shields for breastfeeding women. Breastfeed Med. 2010;5(4):147–51.
16.
go back to reference Auerbach KG. The effect of nipple shields on maternal milk volume. J Obstet Gynecol Neonatal Nurs. 1990;19(5):419–27. Auerbach KG. The effect of nipple shields on maternal milk volume. J Obstet Gynecol Neonatal Nurs. 1990;19(5):419–27.
17.
go back to reference Sakalidis VS, Kent JC, Garbin CP, Hepworth AR, Hartmann PE, Geddes DT. Longitudinal changes in suck-swallow-breathe, oxygen saturation, and heart rate patterns in term breastfeeding infants. J Hum Lact. 2013;29(2):236–45. Sakalidis VS, Kent JC, Garbin CP, Hepworth AR, Hartmann PE, Geddes DT. Longitudinal changes in suck-swallow-breathe, oxygen saturation, and heart rate patterns in term breastfeeding infants. J Hum Lact. 2013;29(2):236–45.
18.
go back to reference Daly SE, Kent JC, Owens RA, Hartmann PE. Frequency and degree of milk removal and the short-term control of human milk synthesis. Exp Physiol. 1996;81(5):861–75.CrossRef Daly SE, Kent JC, Owens RA, Hartmann PE. Frequency and degree of milk removal and the short-term control of human milk synthesis. Exp Physiol. 1996;81(5):861–75.CrossRef
19.
go back to reference Daly SE, Di Rosso A, Owens RA, Hartmann PE. Degree of breast emptying explains changes in the fat content, but not fatty acid composition, of human milk. Exp Physiol. 1993;78(6):741–55. Daly SE, Di Rosso A, Owens RA, Hartmann PE. Degree of breast emptying explains changes in the fat content, but not fatty acid composition, of human milk. Exp Physiol. 1993;78(6):741–55.
20.
21.
go back to reference Bijur PE, Silver W, Gallagher EJ. Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med. 2001;8(12):1153–7. Bijur PE, Silver W, Gallagher EJ. Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med. 2001;8(12):1153–7.
22.
go back to reference Melzack R. The McGill Pain Questionnaire: major properties and scoring methods. Pain. 1975;1(3):277–99.CrossRef Melzack R. The McGill Pain Questionnaire: major properties and scoring methods. Pain. 1975;1(3):277–99.CrossRef
23.
go back to reference Arthur PG, Hartmann PE, Smith M. Measurement of the milk intake of breast-fed infants. J Pediatr Gastroenterol Nutr. 1987;6(5):758–63.CrossRef Arthur PG, Hartmann PE, Smith M. Measurement of the milk intake of breast-fed infants. J Pediatr Gastroenterol Nutr. 1987;6(5):758–63.CrossRef
24.
go back to reference Casey CE, Hambidge KM, Neville MC. Studies in human lactation: zinc, copper, manganese and chromium in human milk in the first month of lactation. Am J Clin Nutr. 1985;41(6):1193–200.CrossRef Casey CE, Hambidge KM, Neville MC. Studies in human lactation: zinc, copper, manganese and chromium in human milk in the first month of lactation. Am J Clin Nutr. 1985;41(6):1193–200.CrossRef
25.
go back to reference Daly SE, Owens RA, Hartmann PE. The short-term synthesis and infant-regulated removal of milk in lactating women. Exp Physiol. 1993;78(2):209–20.CrossRef Daly SE, Owens RA, Hartmann PE. The short-term synthesis and infant-regulated removal of milk in lactating women. Exp Physiol. 1993;78(2):209–20.CrossRef
26.
go back to reference Kent JC, Ramsay DT, Doherty D, Larsson M, Hartmann PE. Response of breasts to different stimulation patterns of an electric breast pump. J Hum Lact. 2003;19(2):179. :– 86; quiz 87 – 8, 218.. Kent JC, Ramsay DT, Doherty D, Larsson M, Hartmann PE. Response of breasts to different stimulation patterns of an electric breast pump. J Hum Lact. 2003;19(2):179. :– 86; quiz 87 – 8, 218..
27.
go back to reference Boonstra AM, Schiphorst Preuper HR, Balk GA, Stewart RE. Cut-off points for mild, moderate, and severe pain on the visual analogue scale for pain in patients with chronic musculoskeletal pain. Pain. 2014;155(12):2545–50.CrossRef Boonstra AM, Schiphorst Preuper HR, Balk GA, Stewart RE. Cut-off points for mild, moderate, and severe pain on the visual analogue scale for pain in patients with chronic musculoskeletal pain. Pain. 2014;155(12):2545–50.CrossRef
28.
go back to reference Kent JC, Mitoulas L, Cox DB, Owens RA, Hartmann PE. Breast volume and milk production during extended lactation in women. Exp Physiol. 1999;84(2):435–47.CrossRef Kent JC, Mitoulas L, Cox DB, Owens RA, Hartmann PE. Breast volume and milk production during extended lactation in women. Exp Physiol. 1999;84(2):435–47.CrossRef
29.
go back to reference McNeilly AS, Robinson IC, Houston MJ, Howie PW. Release of oxytocin and prolactin in response to suckling. Br Med J (Clin Res Ed). 1983;286(6361):257–9.CrossRef McNeilly AS, Robinson IC, Houston MJ, Howie PW. Release of oxytocin and prolactin in response to suckling. Br Med J (Clin Res Ed). 1983;286(6361):257–9.CrossRef
30.
go back to reference Prime DKG, Hartmann D, Oxytocin P. Milk ejection and maternal-infant well-being. In: Hale TWH, P.E., editor. Textbook of Human Lactation. Vol. 1. Texas: Hale Publishing; 2007. pp. 141–58. Prime DKG, Hartmann D, Oxytocin P. Milk ejection and maternal-infant well-being. In: Hale TWH, P.E., editor. Textbook of Human Lactation. Vol. 1. Texas: Hale Publishing; 2007. pp. 141–58.
31.
go back to reference Mitoulas LR, Lai CT, Gurrin LC, Larsson M, Hartmann PE. Effect of vacuum profile on breast milk expression using an electric breast pump. J Hum Lact. 2002;18(4):353–60. Mitoulas LR, Lai CT, Gurrin LC, Larsson M, Hartmann PE. Effect of vacuum profile on breast milk expression using an electric breast pump. J Hum Lact. 2002;18(4):353–60.
32.
go back to reference Prime DK, Geddes DT, Hepworth AR, Trengove NJ, Hartmann PE. Comparison of the patterns of milk ejection during repeated breast expression sessions in women. Breastfeed Med. 2011;6(4):183–90. Prime DK, Geddes DT, Hepworth AR, Trengove NJ, Hartmann PE. Comparison of the patterns of milk ejection during repeated breast expression sessions in women. Breastfeed Med. 2011;6(4):183–90.
33.
go back to reference Prime DK, Kent JC, Hepworth AR, Trengove NJ, Hartmann PE. Dynamics of milk removal during simultaneous breast expression in women. Breastfeed Med. 2012;7(2):100–6. Prime DK, Kent JC, Hepworth AR, Trengove NJ, Hartmann PE. Dynamics of milk removal during simultaneous breast expression in women. Breastfeed Med. 2012;7(2):100–6.
Metadata
Title
Effect of nipple shield use on milk removal: a mechanistic study
Authors
Viviane Silva Coentro
Sharon Lisa Perrella
Ching Tat Lai
Alethea Rea
Kevin Murray
Donna Tracy Geddes
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2020
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-020-03191-5

Other articles of this Issue 1/2020

BMC Pregnancy and Childbirth 1/2020 Go to the issue