Open Access 01-12-2015 | Research article

Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial

Authors: Véronique Equy, Sandra David-Tchouda, Michel Dreyfus, Didier Riethmuller, Françoise Vendittelli, Victoire Cabaud, Bruno Langer, Jennifer Margier, Jean-Luc Bosson, Jean-Patrick Schaal

Published in: BMC Pregnancy and Childbirth | Issue 1/2015

Login to get access

Abstract

Background

Assisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup.

Methods

This was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears.

Results

335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events.

Conclusions

While the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries.

Trial registration

Appendix
Available only for authorised users
Literature
1.
go back to reference Mangin M, Ramanah R, Aouar Z, Courtois L, Collin A, Cossa S, et al. Operative delivery data in France for 2007: results of a national survey within teaching hospitals. J Gynecol Obstet Biol Reprod (Paris). 2010;39(2):121–32.CrossRef Mangin M, Ramanah R, Aouar Z, Courtois L, Collin A, Cossa S, et al. Operative delivery data in France for 2007: results of a national survey within teaching hospitals. J Gynecol Obstet Biol Reprod (Paris). 2010;39(2):121–32.CrossRef
2.
go back to reference Schaal JP, Equy V, Hoffman P. Comparison vacuum extractor versus forceps. J Gynecol Obstet Biol Reprod (Paris). 2008;37(supll8):S231–43.CrossRef Schaal JP, Equy V, Hoffman P. Comparison vacuum extractor versus forceps. J Gynecol Obstet Biol Reprod (Paris). 2008;37(supll8):S231–43.CrossRef
3.
go back to reference O'Mahony F, Hofmeyr GJ, Menon V. Choice of instruments for assisted vaginal delivery. Cochrane Database Syst Rev. 2010;11:CD005455.PubMed O'Mahony F, Hofmeyr GJ, Menon V. Choice of instruments for assisted vaginal delivery. Cochrane Database Syst Rev. 2010;11:CD005455.PubMed
4.
go back to reference Vayssière C, Beucher G, Dupuis O, Feraud O, Simon-Toulza C, Sentilhes L, et al. Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians. Eur J Obstet Gynecol Reprod Biol. 2011;159(1):43–8.CrossRefPubMed Vayssière C, Beucher G, Dupuis O, Feraud O, Simon-Toulza C, Sentilhes L, et al. Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians. Eur J Obstet Gynecol Reprod Biol. 2011;159(1):43–8.CrossRefPubMed
5.
go back to reference Riethmuller D, Ramanah R, Maillet R, Schaal JP. Vacuum extractors: description, mechanics, indications and contra-indications. J Gynecol Obstet Biol Reprod (Paris). 2008;37 Suppl 8:S210–21.CrossRef Riethmuller D, Ramanah R, Maillet R, Schaal JP. Vacuum extractors: description, mechanics, indications and contra-indications. J Gynecol Obstet Biol Reprod (Paris). 2008;37 Suppl 8:S210–21.CrossRef
6.
go back to reference Vacca A. Operative vaginal delivery: clinical appraisal of a new vacuum extraction device. Aust N Z J Obstet Gynaecol. 2001;41:156–60.CrossRefPubMed Vacca A. Operative vaginal delivery: clinical appraisal of a new vacuum extraction device. Aust N Z J Obstet Gynaecol. 2001;41:156–60.CrossRefPubMed
7.
go back to reference Vacca A. Vacuum-assisted delivery: an analysis of traction force and maternal and neonatal outcomes. Aust N Z J Obstet Gynaecol. 2006;46(2):124–7.CrossRefPubMed Vacca A. Vacuum-assisted delivery: an analysis of traction force and maternal and neonatal outcomes. Aust N Z J Obstet Gynaecol. 2006;46(2):124–7.CrossRefPubMed
8.
go back to reference Hayman R, Gilby J, Arulkumaran S. Clinical evaluation of a “hand pump” vacuum delivery device. Obstet Gynecol. 2002;100(6):1190–5.PubMed Hayman R, Gilby J, Arulkumaran S. Clinical evaluation of a “hand pump” vacuum delivery device. Obstet Gynecol. 2002;100(6):1190–5.PubMed
9.
go back to reference Machin D, Campbell MJ. Statistical Tables for Design of Clinical Trials. Oxford: Blackwell Scientific Publications; 1987. Machin D, Campbell MJ. Statistical Tables for Design of Clinical Trials. Oxford: Blackwell Scientific Publications; 1987.
10.
go back to reference Fleiss JL, Tytun A, Ury SHK. A simple approximation for calculating sample sizes for comparing independent proportions. Biometrics. 1980;36:343–6.CrossRefPubMed Fleiss JL, Tytun A, Ury SHK. A simple approximation for calculating sample sizes for comparing independent proportions. Biometrics. 1980;36:343–6.CrossRefPubMed
11.
go back to reference Hammarstrom M, Csemiczky G, Belfrage P. Comparison between the conventional Malmstrom extractor and a new extractor with Silastic cup. Acta Obstet Gynecol Scand. 1986;65(7):791–2.CrossRefPubMed Hammarstrom M, Csemiczky G, Belfrage P. Comparison between the conventional Malmstrom extractor and a new extractor with Silastic cup. Acta Obstet Gynecol Scand. 1986;65(7):791–2.CrossRefPubMed
12.
go back to reference Thiery M, Van Den Broecke R, Kermans G, Parewijck W, Dhont M, Vanlancker M, et al. A randomized study of two cups for vacuum extraction. J Perinat Med. 1987;15(2):129–36.CrossRefPubMed Thiery M, Van Den Broecke R, Kermans G, Parewijck W, Dhont M, Vanlancker M, et al. A randomized study of two cups for vacuum extraction. J Perinat Med. 1987;15(2):129–36.CrossRefPubMed
13.
go back to reference Cohn M, Barclay C, Fraser R, Zaklama M, Johanson R, Anderson D, et al. A multicentre randomized trial comparing delivery with a silicone rubber cup and rigid metal vacuum extractor cups. BJOG. 1989;96(5):545–51.CrossRef Cohn M, Barclay C, Fraser R, Zaklama M, Johanson R, Anderson D, et al. A multicentre randomized trial comparing delivery with a silicone rubber cup and rigid metal vacuum extractor cups. BJOG. 1989;96(5):545–51.CrossRef
14.
go back to reference Chenoy R, Johanson R. A randomized prospective study comparing delivery with metal and silicone rubber vacuum extractor cups. Br J Obstet Gynaecol. 1992;99(5):360–3.CrossRefPubMed Chenoy R, Johanson R. A randomized prospective study comparing delivery with metal and silicone rubber vacuum extractor cups. Br J Obstet Gynaecol. 1992;99(5):360–3.CrossRefPubMed
15.
go back to reference Loghis C, Pyrgiotis E, Panayotopoulos N, Batalias L, Salamalekis E, Zourlas PA. Comparison between metal cup and silicone rubber cup vacuum extractor. Eur J Obstet Gynecol Reprod Biol. 1992;45(3):173–6.CrossRefPubMed Loghis C, Pyrgiotis E, Panayotopoulos N, Batalias L, Salamalekis E, Zourlas PA. Comparison between metal cup and silicone rubber cup vacuum extractor. Eur J Obstet Gynecol Reprod Biol. 1992;45(3):173–6.CrossRefPubMed
16.
go back to reference Kuit JA, Eppinga HG, Wallenburg HC, Huikeshoven FJ. A randomized comparison of vacuum extraction delivery with a rigid and a pliable cup. Obstet Gynecol. 1993;82(2):280–4.PubMed Kuit JA, Eppinga HG, Wallenburg HC, Huikeshoven FJ. A randomized comparison of vacuum extraction delivery with a rigid and a pliable cup. Obstet Gynecol. 1993;82(2):280–4.PubMed
17.
go back to reference Attilakos G, Sibanda T, Winter C, Johnson N, Draycott T. A randomised controlled trial of a new handheld vacuum extraction device. BJOG. 2005;112(11):1510–5.CrossRefPubMed Attilakos G, Sibanda T, Winter C, Johnson N, Draycott T. A randomised controlled trial of a new handheld vacuum extraction device. BJOG. 2005;112(11):1510–5.CrossRefPubMed
18.
go back to reference Groom KM, Jones BA, Miller N, Paterson-Brown S. A prospective randomised controlled trial of the Kiwi OmniCup versus conventional ventouse cups for vacuum-assisted vaginal delivery. BJOG. 2006;113(2):183–9.CrossRefPubMed Groom KM, Jones BA, Miller N, Paterson-Brown S. A prospective randomised controlled trial of the Kiwi OmniCup versus conventional ventouse cups for vacuum-assisted vaginal delivery. BJOG. 2006;113(2):183–9.CrossRefPubMed
19.
go back to reference Ismail NA, Saharan WS, Zaleha MA, Jaafar R, Muhammad JA, Razi ZR. Kiwi omniCup versus malmstrom metal cup in vacuum assisted delivery: a randomized comparative trial. J Obstet Gynaecol Res. 2008;34(3):350–3.CrossRefPubMed Ismail NA, Saharan WS, Zaleha MA, Jaafar R, Muhammad JA, Razi ZR. Kiwi omniCup versus malmstrom metal cup in vacuum assisted delivery: a randomized comparative trial. J Obstet Gynaecol Res. 2008;34(3):350–3.CrossRefPubMed
20.
go back to reference Mola GD, Kuk JM. A randomised controlled trial of two instruments for vacuum-assisted delivery (Vacca Re-Usable OmniCup and the Bird anterior and posterior cups) to compare failure rates, safety and use effectiveness. Aust N Z J Obstet Gynaecol. 2010;50:246–52.CrossRefPubMed Mola GD, Kuk JM. A randomised controlled trial of two instruments for vacuum-assisted delivery (Vacca Re-Usable OmniCup and the Bird anterior and posterior cups) to compare failure rates, safety and use effectiveness. Aust N Z J Obstet Gynaecol. 2010;50:246–52.CrossRefPubMed
21.
go back to reference Velemir L, Vendittelli F, Bonnefoy C, Accoceberry M, Savary D, Gallot D. Learning curve of vacuum extraction in residency: a preliminary study. J Gynecol Obstet Biol Reprod (Paris). 2009;38:421–9.CrossRef Velemir L, Vendittelli F, Bonnefoy C, Accoceberry M, Savary D, Gallot D. Learning curve of vacuum extraction in residency: a preliminary study. J Gynecol Obstet Biol Reprod (Paris). 2009;38:421–9.CrossRef
22.
go back to reference Eskander R, Beall M, Ross MG. Vacuum-assisted vaginal delivery simulation-quantitation of subjective measures of traction and detachment forces. J Matern Fetal Neonatal Med. 2012;25(10):2039–41.CrossRefPubMed Eskander R, Beall M, Ross MG. Vacuum-assisted vaginal delivery simulation-quantitation of subjective measures of traction and detachment forces. J Matern Fetal Neonatal Med. 2012;25(10):2039–41.CrossRefPubMed
Metadata
Title
Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial
Authors
Véronique Equy
Sandra David-Tchouda
Michel Dreyfus
Didier Riethmuller
Françoise Vendittelli
Victoire Cabaud
Bruno Langer
Jennifer Margier
Jean-Luc Bosson
Jean-Patrick Schaal
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2015
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-015-0771-1

Other articles of this Issue 1/2015

BMC Pregnancy and Childbirth 1/2015 Go to the issue