Skip to main content
Top
Published in: BMC Medical Imaging 1/2020

Open Access 01-12-2020 | Research article

An enhanced adaptive non-local means algorithm for Rician noise reduction in magnetic resonance brain images

Authors: Kaixin Chen, Xiao Lin, Xing Hu, Jiayao Wang, Han Zhong, Linhua Jiang

Published in: BMC Medical Imaging | Issue 1/2020

Login to get access

Abstract

Background

The Rician noise formed in magnetic resonance (MR) imaging greatly reduced the accuracy and reliability of subsequent analysis, and most of the existing denoising methods are suitable for Gaussian noise rather than Rician noise. Aiming to solve this problem, we proposed fuzzy c-means and adaptive non-local means (FANLM), which combined the adaptive non-local means (NLM) with fuzzy c-means (FCM), as a novel method to reduce noise in the study.

Method

The algorithm chose the optimal size of search window automatically based on the noise variance which was estimated by the improved estimator of the median absolute deviation (MAD) for Rician noise. Meanwhile, it solved the problem that the traditional NLM algorithm had to use a fixed size of search window. Considering the distribution characteristics for each pixel, we designed three types of search window sizes as large, medium and small instead of using a fixed size. In addition, the combination with the FCM algorithm helped to achieve better denoising effect since the improved the FCM algorithm divided the membership degrees of images and introduced the morphological reconstruction to preserve the image details.

Results

The experimental results showed that the proposed algorithm (FANLM) can effectively remove the noise. Moreover, it had the highest peak signal-noise ratio (PSNR) and structural similarity (SSIM), compared with other three methods: non-local means (NLM), linear minimum mean square error (LMMSE) and undecimated wavelet transform (UWT). Using the FANLM method, the image details can be well preserved with the noise being mostly removed.

Conclusion

Compared with the traditional denoising methods, the experimental results showed that the proposed approach effectively suppressed the noise and the edge details were well retained. However, the FANLM method took an average of 13 s throughout the experiment, and its computational cost was not the shortest. Addressing these can be part of our future research.
Literature
3.
go back to reference Yang X, Fei B. A wavelet multiscale denoising algorithm for magnetic resonance (MR) images. Measurementence Technol. 2011;22(22):25803. Yang X, Fei B. A wavelet multiscale denoising algorithm for magnetic resonance (MR) images. Measurementence Technol. 2011;22(22):25803.
4.
go back to reference Ville DVD, Seghier ML, Lazeyras F, Blu T, Unser M. WSPM: wavelet-based statistical parametric mapping. Neuroimage. 2007;37(4):1205–17.CrossRef Ville DVD, Seghier ML, Lazeyras F, Blu T, Unser M. WSPM: wavelet-based statistical parametric mapping. Neuroimage. 2007;37(4):1205–17.CrossRef
5.
go back to reference Aleksandra P, Wilfried P, Ignace L, Marc A. A versatile wavelet domain noise filtration technique for medical imaging. IEEE Trans Med Imaging. 2003;22(3):323–31.CrossRef Aleksandra P, Wilfried P, Ignace L, Marc A. A versatile wavelet domain noise filtration technique for medical imaging. IEEE Trans Med Imaging. 2003;22(3):323–31.CrossRef
6.
go back to reference Karl K, Santiago AF. Noise-driven anisotropic diffusion filtering of MRI. IEEE Trans Image Process Publication IEEE Signal Process Soc. 2009;18(10):2265. Karl K, Santiago AF. Noise-driven anisotropic diffusion filtering of MRI. IEEE Trans Image Process Publication IEEE Signal Process Soc. 2009;18(10):2265.
8.
go back to reference Santiago AF, Marc N, Marek K, Shenton ME, Carl-Fredrik W. Restoration of DWI data using a Rician LMMSE estimator. IEEE Trans Med Imaging. 2008;27(10):1389–403.CrossRef Santiago AF, Marc N, Marek K, Shenton ME, Carl-Fredrik W. Restoration of DWI data using a Rician LMMSE estimator. IEEE Trans Med Imaging. 2008;27(10):1389–403.CrossRef
9.
go back to reference Golshan HM, Hasanzadeh RPR, Yousefzadeh SC. An MRI denoising method using image data redundancy and local SNR estimation. Magn Reson Imaging. 2013;31(7):1206–17.CrossRef Golshan HM, Hasanzadeh RPR, Yousefzadeh SC. An MRI denoising method using image data redundancy and local SNR estimation. Magn Reson Imaging. 2013;31(7):1206–17.CrossRef
10.
go back to reference Jeny R, Ben J, Marleen V, Johan VA, Jan S. Maximum likelihood estimation-based denoising of magnetic resonance images using restricted local neighborhoods. Phys Med Biol. 2011;56(16):5221.CrossRef Jeny R, Ben J, Marleen V, Johan VA, Jan S. Maximum likelihood estimation-based denoising of magnetic resonance images using restricted local neighborhoods. Phys Med Biol. 2011;56(16):5221.CrossRef
11.
go back to reference Rajan J, Veraart J, Audekerke JV, Verhoye M, Sijbers J. Nonlocal maximum likelihood estimation method for denoising multiple-coil magnetic resonance images. Magn Reson Imaging. 2012;30(10):1512–8.CrossRef Rajan J, Veraart J, Audekerke JV, Verhoye M, Sijbers J. Nonlocal maximum likelihood estimation method for denoising multiple-coil magnetic resonance images. Magn Reson Imaging. 2012;30(10):1512–8.CrossRef
13.
go back to reference Coupe P, ., Yger P, ., Prima S, ., Hellier P, ., Kervrann C, ., Barillot C, . (2008) An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images. IEEE Trans Med Imaging 27 (4):425–441.CrossRef Coupe P, ., Yger P, ., Prima S, ., Hellier P, ., Kervrann C, ., Barillot C, . (2008) An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images. IEEE Trans Med Imaging 27 (4):425–441.CrossRef
14.
go back to reference Thaipanich T. Kuo CCJ an adaptive nonlocal means scheme for medical image Denoising. In: Med Imaging: Image Process. 2010. Thaipanich T. Kuo CCJ an adaptive nonlocal means scheme for medical image Denoising. In: Med Imaging: Image Process. 2010.
15.
go back to reference Kang B, Choi O, Kim JD, Hwang D. Noise reduction in magnetic resonance images using adaptive non-local means filtering. Electron Lett. 2013;49(5):324–5.CrossRef Kang B, Choi O, Kim JD, Hwang D. Noise reduction in magnetic resonance images using adaptive non-local means filtering. Electron Lett. 2013;49(5):324–5.CrossRef
16.
go back to reference Bhujle HV, Chaudhuri S. Laplacian based non-local means denoising of MR images with Rician noise. Magn Reson Imaging. 2013;31(9):1599–610.CrossRef Bhujle HV, Chaudhuri S. Laplacian based non-local means denoising of MR images with Rician noise. Magn Reson Imaging. 2013;31(9):1599–610.CrossRef
17.
go back to reference Bezdek JC, Ehrlich R, Full W. FCM: the fuzzy c -means clustering algorithm. Comput Geosci. 1984;10(2):191–203.CrossRef Bezdek JC, Ehrlich R, Full W. FCM: the fuzzy c -means clustering algorithm. Comput Geosci. 1984;10(2):191–203.CrossRef
18.
go back to reference Stelios K, Vassilios C. A robust fuzzy local information C-means clustering algorithm. IEEE Trans Image Process Publication IEEE Signal Process Soc. 2010;19(5):1328. Stelios K, Vassilios C. A robust fuzzy local information C-means clustering algorithm. IEEE Trans Image Process Publication IEEE Signal Process Soc. 2010;19(5):1328.
19.
go back to reference Gong M, Zhou Z, Ma J. Change detection in synthetic aperture radar images based on image fusion and fuzzy clustering. Image Process IEEE Trans. 2012;21(4):2141–51.CrossRef Gong M, Zhou Z, Ma J. Change detection in synthetic aperture radar images based on image fusion and fuzzy clustering. Image Process IEEE Trans. 2012;21(4):2141–51.CrossRef
20.
go back to reference Maoguo G, Yan L, Jiao S, Wenping M, Jingjing M. Fuzzy C-means clustering with local information and kernel metric for image segmentation. IEEE Trans Image Process. 2013;22(2):573–84.CrossRef Maoguo G, Yan L, Jiao S, Wenping M, Jingjing M. Fuzzy C-means clustering with local information and kernel metric for image segmentation. IEEE Trans Image Process. 2013;22(2):573–84.CrossRef
21.
go back to reference Tao L, Jia X, Zhang Y, He L, Meng H, Nandi AK. Significantly fast and robust fuzzy C-means clustering algorithm based on morphological reconstruction and membership filtering. IEEE Transactions on Fuzzy Systems PP. 2018;99:1–1. Tao L, Jia X, Zhang Y, He L, Meng H, Nandi AK. Significantly fast and robust fuzzy C-means clustering algorithm based on morphological reconstruction and membership filtering. IEEE Transactions on Fuzzy Systems PP. 2018;99:1–1.
22.
go back to reference Chang SG, Yu B, ., Vetterli M, . (2000) Spatially adaptive wavelet thresholding with context modeling for image denoising. IEEE Trans Image Process 9 (9):1522–1531.CrossRef Chang SG, Yu B, ., Vetterli M, . (2000) Spatially adaptive wavelet thresholding with context modeling for image denoising. IEEE Trans Image Process 9 (9):1522–1531.CrossRef
24.
go back to reference Donoho DL, Johnstone IM. Ideal spatial adaptation by wavelet shrinkage. Biometrika. 1994;81(3):425–55.CrossRef Donoho DL, Johnstone IM. Ideal spatial adaptation by wavelet shrinkage. Biometrika. 1994;81(3):425–55.CrossRef
25.
go back to reference Guan KC, Basser PJ. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson. 2006;179(2):317–22.CrossRef Guan KC, Basser PJ. Analytically exact correction scheme for signal extraction from noisy magnitude MR signals. J Magn Reson. 2006;179(2):317–22.CrossRef
27.
go back to reference Buades A, Coll B, Morel JM. Image Denoising methods. A new nonlocal principle. SIAM Rev. 2010;52(1):113–47.CrossRef Buades A, Coll B, Morel JM. Image Denoising methods. A new nonlocal principle. SIAM Rev. 2010;52(1):113–47.CrossRef
28.
go back to reference Ville DVD, Kocher M. SURE-based non-local means. IEEE Signal Process Lett. 2009;16(11):973–6.CrossRef Ville DVD, Kocher M. SURE-based non-local means. IEEE Signal Process Lett. 2009;16(11):973–6.CrossRef
29.
go back to reference Manjón JV, Carbonell-Caballero J, Lull JJ, García-Martí G, Martí-Bonmatí L, Robles M. MRI denoising using non-local means. Med Image Anal. 2008;12(4):514–23.CrossRef Manjón JV, Carbonell-Caballero J, Lull JJ, García-Martí G, Martí-Bonmatí L, Robles M. MRI denoising using non-local means. Med Image Anal. 2008;12(4):514–23.CrossRef
Metadata
Title
An enhanced adaptive non-local means algorithm for Rician noise reduction in magnetic resonance brain images
Authors
Kaixin Chen
Xiao Lin
Xing Hu
Jiayao Wang
Han Zhong
Linhua Jiang
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2020
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-019-0407-4

Other articles of this Issue 1/2020

BMC Medical Imaging 1/2020 Go to the issue