Skip to main content
Top
Published in: BMC Medical Imaging 1/2018

Open Access 01-12-2018 | Research article

A pilot study on adjunctive use of parametric colour-coded digital subtraction angiography in endovascular interventions of haemodialysis access

Authors: Ru Yu Tan, Tze Tec Chong, Fu Chieh Tsai, Suh Chien Pang, Kian Guan Lee, Apoorva Gogna, Alicia Huiying Ong, Chieh Suai Tan

Published in: BMC Medical Imaging | Issue 1/2018

Login to get access

Abstract

Background

Two-dimensional digital subtraction angiography (DSA) is the gold standard for angiographic evaluation of dysfunctional haemodialysis access. We aim to investigate the utility of parametric colour coded DSA in providing hemodynamic analysis during haemodialysis access interventions.

Methods

We retrospectively studied 20 patients who underwent access intervention and applied parametric colour-coding on selected DSA acquisitions before and after percutaneous transluminal angioplasty (PTA). The difference in time to peak (dTTP) contrast enhancement and time attenuation curve (TAC) of pre- and post-stenotic regions of interest (ROIs) were obtained and compared after treatment.

Results

Improvements were seen in mean percent of stenosis after PTA (p < 0.0001) for all cases. Median dTTP improved from 0.52 (IQR 0.26, 0.8) to 0.25 (IQR 0, 0.26) seconds (p = 0.001). Median 50% contrast washout time improved from 0.77 (IQR 0.39, 1.17) to 0.42 (IQR 0.23, 0.59) seconds (p = 0.031). Significant correlation was seen for dTTP vs. percent of stenosis (r = 0.723, p = 0.043) pre-PTA and for change in dTTP vs. percent change in stenosis post-PTA (r = 0.786, p = 0.021) for inflow lesions. Such correlation was however not seen in outflow lesions.

Conclusions

Adjunctive use of parametric colour-coded DSA may provide potentially useful hemodynamic information during vascular access interventions. Larger prospective studies are needed to validate our findings.
Literature
1.
go back to reference Schinstock CA, Albright RC, Williams AW, Dillon JJ, Bergstralh EJ, Jenson BM, et al. Outcomes of arteriovenous fistula creation after the fistula first initiative. Clin J Am Soc Nephrol. 2011;6(8):1996–2002.CrossRef Schinstock CA, Albright RC, Williams AW, Dillon JJ, Bergstralh EJ, Jenson BM, et al. Outcomes of arteriovenous fistula creation after the fistula first initiative. Clin J Am Soc Nephrol. 2011;6(8):1996–2002.CrossRef
2.
go back to reference Roy-Chaudhury P, Sukhatme VP, Cheung AK. Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol. 2006;17(4):1112–27.CrossRef Roy-Chaudhury P, Sukhatme VP, Cheung AK. Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol. 2006;17(4):1112–27.CrossRef
3.
go back to reference Razek AA, Saad E, Soliman N, Elatta HA. Assessment of vascular disorders of the upper extremity with contrast-enhanced magnetic resonance angiography: pictorial review. Jpn J Radiol. 2010;28(2):87–94.CrossRef Razek AA, Saad E, Soliman N, Elatta HA. Assessment of vascular disorders of the upper extremity with contrast-enhanced magnetic resonance angiography: pictorial review. Jpn J Radiol. 2010;28(2):87–94.CrossRef
4.
go back to reference NKF-DOQI. Clinical Practice Guidelines for Vascular Access. Am J Kidney Dis. 2006;48:S176–247. NKF-DOQI. Clinical Practice Guidelines for Vascular Access. Am J Kidney Dis. 2006;48:S176–247.
5.
go back to reference Mishler R, Sands JJ, Ofsthun NJ, Teng M, Schon D, Lazarus JM. Dedicated outpatient vascular access center decreases hospitalization and missed outpatient dialysis treatments. Kidney Int. 2006;69(2):393–8.CrossRef Mishler R, Sands JJ, Ofsthun NJ, Teng M, Schon D, Lazarus JM. Dedicated outpatient vascular access center decreases hospitalization and missed outpatient dialysis treatments. Kidney Int. 2006;69(2):393–8.CrossRef
6.
go back to reference Doelman C, Duijm LEM, Liem YS, Froger CL, Tielbeek AV, Donkers-van Rossum AB, et al. Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography. J Vasc Surg. 2005;42(4):739–46.CrossRef Doelman C, Duijm LEM, Liem YS, Froger CL, Tielbeek AV, Donkers-van Rossum AB, et al. Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography. J Vasc Surg. 2005;42(4):739–46.CrossRef
7.
go back to reference Leontiev O, Mondschein JI, Dagli MS, Clark TWI, Soulen MC, Stavropoulos SW, et al. Catheter-based Intraaccess blood flow measurement as a problem-solving tool in hemodialysis access intervention. J Vasc Interv Radiol. 2013;24(5):717–21.CrossRef Leontiev O, Mondschein JI, Dagli MS, Clark TWI, Soulen MC, Stavropoulos SW, et al. Catheter-based Intraaccess blood flow measurement as a problem-solving tool in hemodialysis access intervention. J Vasc Interv Radiol. 2013;24(5):717–21.CrossRef
8.
go back to reference Gray RJ, Sacks D, Martin LG, Trerotola SO. Reporting standards for percutaneous interventions in dialysis access. J Vasc Interv Radiol. 2003;14(9 Pt 2):S433–42.CrossRef Gray RJ, Sacks D, Martin LG, Trerotola SO. Reporting standards for percutaneous interventions in dialysis access. J Vasc Interv Radiol. 2003;14(9 Pt 2):S433–42.CrossRef
9.
go back to reference Strother CM, Bender F, Deuerling-Zheng Y, Royalty K, Pulfer KA, Baumgart J, et al. Parametric color coding of digital subtraction angiography. AJNR Am J Neuroradiol. 2010;31(5):919–24.CrossRef Strother CM, Bender F, Deuerling-Zheng Y, Royalty K, Pulfer KA, Baumgart J, et al. Parametric color coding of digital subtraction angiography. AJNR Am J Neuroradiol. 2010;31(5):919–24.CrossRef
10.
go back to reference Golitz P, Struffert T, Lucking H, Rosch J, Knossalla F, Ganslandt O, et al. Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas. Clin Neuroradiol. 2013;23(2):113–20.CrossRef Golitz P, Struffert T, Lucking H, Rosch J, Knossalla F, Ganslandt O, et al. Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas. Clin Neuroradiol. 2013;23(2):113–20.CrossRef
11.
go back to reference Lin CJ, Hung SC, Guo WY, Chang FC, Luo CB, Beilner J, et al. Monitoring peri-therapeutic cerebral circulation time: a feasibility study using color-coded quantitative DSA in patients with steno-occlusive arterial disease. AJNR Am J Neuroradiol. 2012;33(9):1685–90.CrossRef Lin CJ, Hung SC, Guo WY, Chang FC, Luo CB, Beilner J, et al. Monitoring peri-therapeutic cerebral circulation time: a feasibility study using color-coded quantitative DSA in patients with steno-occlusive arterial disease. AJNR Am J Neuroradiol. 2012;33(9):1685–90.CrossRef
12.
go back to reference Su H, Lou W, Gu J. Clinical values of hemodynamics assessment by parametric color coding of digital subtraction angiography before and after endovascular therapy for critical limb ischaemia. Zhonghua Yi Xue Za Zhi. 2015;95(37):3036–40.PubMed Su H, Lou W, Gu J. Clinical values of hemodynamics assessment by parametric color coding of digital subtraction angiography before and after endovascular therapy for critical limb ischaemia. Zhonghua Yi Xue Za Zhi. 2015;95(37):3036–40.PubMed
13.
go back to reference Whittier WL. Surveillance of hemodialysis vascular access. Semin Interv Radiol. 2009;26(2):130–8.CrossRef Whittier WL. Surveillance of hemodialysis vascular access. Semin Interv Radiol. 2009;26(2):130–8.CrossRef
14.
go back to reference Kim WS, Pyun WB, Kang BC. The primary patency of percutaneous Transluminal angioplasty in hemodialysis patients with vascular access failure. Korean Circ J. 2011;41(9):512–7.CrossRef Kim WS, Pyun WB, Kang BC. The primary patency of percutaneous Transluminal angioplasty in hemodialysis patients with vascular access failure. Korean Circ J. 2011;41(9):512–7.CrossRef
15.
go back to reference Agarwal SK, Nadkarni GN, Yacoub R, Patel AA, Jenkins JS, Collins TJ, et al. Comparison of cutting balloon angioplasty and percutaneous balloon angioplasty of Arteriovenous fistula stenosis: a meta-analysis and systematic review of randomized clinical trials. J Interv Cardiol. 2015;28(3):288–95.CrossRef Agarwal SK, Nadkarni GN, Yacoub R, Patel AA, Jenkins JS, Collins TJ, et al. Comparison of cutting balloon angioplasty and percutaneous balloon angioplasty of Arteriovenous fistula stenosis: a meta-analysis and systematic review of randomized clinical trials. J Interv Cardiol. 2015;28(3):288–95.CrossRef
16.
go back to reference Ahya SN, Windus DW, Vesely TM. Flow in hemodialysis grafts after angioplasty: do radiologic criteria predict success? Kidney Int. 2001;59(5):1974–8.CrossRef Ahya SN, Windus DW, Vesely TM. Flow in hemodialysis grafts after angioplasty: do radiologic criteria predict success? Kidney Int. 2001;59(5):1974–8.CrossRef
17.
go back to reference Goyal A, Orth RC, Parekh RS, Wolfson T, Gamst A, Kuo MD. Endpoints for hemodialysis access procedures: correlation between fistulography and intraaccess blood flow measurements. J Vasc Interv Radiol. 2011;22(12):1733–9.CrossRef Goyal A, Orth RC, Parekh RS, Wolfson T, Gamst A, Kuo MD. Endpoints for hemodialysis access procedures: correlation between fistulography and intraaccess blood flow measurements. J Vasc Interv Radiol. 2011;22(12):1733–9.CrossRef
18.
go back to reference Abdel Razek AAK, Denewer AT, Hegazy MAF, Hafez MTA. Role of computed tomography angiography in the diagnosis of vascular stenosis in head and neck microvascular free flap reconstruction. Int J Oral Maxillofac Surg. 2014;43(7):811–5.CrossRef Abdel Razek AAK, Denewer AT, Hegazy MAF, Hafez MTA. Role of computed tomography angiography in the diagnosis of vascular stenosis in head and neck microvascular free flap reconstruction. Int J Oral Maxillofac Surg. 2014;43(7):811–5.CrossRef
19.
go back to reference Lin YP, Wu MH, Ng YY, Lee RC, Liou JK, Yang WC, et al. Spiral computed tomographic angiography--a new technique for evaluation of vascular access in hemodialysis patients. Am J Nephrol. 1998;18(2):117–22.CrossRef Lin YP, Wu MH, Ng YY, Lee RC, Liou JK, Yang WC, et al. Spiral computed tomographic angiography--a new technique for evaluation of vascular access in hemodialysis patients. Am J Nephrol. 1998;18(2):117–22.CrossRef
20.
go back to reference Razek AA, Gaballa G, Megahed AS, Elmogy E. Time resolved imaging of contrast kinetics (TRICKS) MR angiography of arteriovenous malformations of head and neck. Eur J Radiol. 2013;82(11):1885–91.CrossRef Razek AA, Gaballa G, Megahed AS, Elmogy E. Time resolved imaging of contrast kinetics (TRICKS) MR angiography of arteriovenous malformations of head and neck. Eur J Radiol. 2013;82(11):1885–91.CrossRef
21.
go back to reference Zhang J, Hecht EM, Maldonado T, Lee VS. Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: initial experience. AJR Am J Roentgenol. 2006;186(5):1436–42.CrossRef Zhang J, Hecht EM, Maldonado T, Lee VS. Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: initial experience. AJR Am J Roentgenol. 2006;186(5):1436–42.CrossRef
22.
go back to reference Heerwagen ST, Hansen MA, Schroeder TV, Ladefoged SD, Lonn L. Blood flow measurements during hemodialysis vascular access interventions--catheter-based thermodilution or Doppler ultrasound? J Vasc Access. 2012;13(2):145–51.CrossRef Heerwagen ST, Hansen MA, Schroeder TV, Ladefoged SD, Lonn L. Blood flow measurements during hemodialysis vascular access interventions--catheter-based thermodilution or Doppler ultrasound? J Vasc Access. 2012;13(2):145–51.CrossRef
23.
go back to reference Asif A, Besarab A, Gadalean F, Merrill D, Rismeyer AE, Contreras G, et al. Utility of static pressure ratio recording during angioplasty of arteriovenous graft stenosis. Semin Dial. 2006;19(6):551–6.CrossRef Asif A, Besarab A, Gadalean F, Merrill D, Rismeyer AE, Contreras G, et al. Utility of static pressure ratio recording during angioplasty of arteriovenous graft stenosis. Semin Dial. 2006;19(6):551–6.CrossRef
24.
go back to reference Leontiev O, Shlansky-Goldberg RD, Stavropoulos SW, Mondschein JI, Itkin M, Clark TWI, et al. Should all inflow Stenoses be treated in failing autogenous hemodialysis fistulae? J Vasc Interv Radiol. 2014;25(4):542–7.CrossRef Leontiev O, Shlansky-Goldberg RD, Stavropoulos SW, Mondschein JI, Itkin M, Clark TWI, et al. Should all inflow Stenoses be treated in failing autogenous hemodialysis fistulae? J Vasc Interv Radiol. 2014;25(4):542–7.CrossRef
25.
go back to reference Agarwal AK. Endovascular interventions for central vein stenosis. Kidney Res Clin Pract. 2015;34(4):228–32.CrossRef Agarwal AK. Endovascular interventions for central vein stenosis. Kidney Res Clin Pract. 2015;34(4):228–32.CrossRef
26.
go back to reference Cole BL, Maddocks JD, Sharpe K. Visual search and the conspicuity of coloured targets for colour vision normal and colour vision deficient observers. Clin Exp Optom. 2004;87(4–5):294–304.CrossRef Cole BL, Maddocks JD, Sharpe K. Visual search and the conspicuity of coloured targets for colour vision normal and colour vision deficient observers. Clin Exp Optom. 2004;87(4–5):294–304.CrossRef
27.
go back to reference Benndorf G. Color-coded digital subtraction angiography: the end of a monochromatic era? AJNR Am J Neuroradiol. 2010;31(5):925–7.CrossRef Benndorf G. Color-coded digital subtraction angiography: the end of a monochromatic era? AJNR Am J Neuroradiol. 2010;31(5):925–7.CrossRef
Metadata
Title
A pilot study on adjunctive use of parametric colour-coded digital subtraction angiography in endovascular interventions of haemodialysis access
Authors
Ru Yu Tan
Tze Tec Chong
Fu Chieh Tsai
Suh Chien Pang
Kian Guan Lee
Apoorva Gogna
Alicia Huiying Ong
Chieh Suai Tan
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2018
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-018-0270-8

Other articles of this Issue 1/2018

BMC Medical Imaging 1/2018 Go to the issue