Skip to main content
Top
Published in: BMC Medical Imaging 1/2017

Open Access 01-12-2017 | Research Article

Electronic cleansing in computed tomography colonography using AT layer identification with integration of gradient directional second derivative and material fraction model

Authors: Krisorn Chunhapongpipat, Ratinan Boonklurb, Bundit Chaopathomkul, Sirod Sirisup, Rajalida Lipikorn

Published in: BMC Medical Imaging | Issue 1/2017

Login to get access

Abstract

Background

In computed tomography colonography images, electronic cleansing (EC) is applied to remove opacified residual materials, called fecal-tagging materials (FTM), using positive-contrast tagging agents and laxative to facilitate polyp detection.

Methods

The proposed EC, EC prop , integrates the gradient directional second derivative into material fraction model to preserve submerged soft tissue (ST) under FTM. Three-material fraction model is used to remove FTM and artifacts at air-tagging (AT) layers and T-junctions where air, ST, and FTM material meet simultaneously. Moreover, the proposed AT layer identification is used to distinguish AT layers from air-tissue-tagging (ATT) layers in order to preserve ATT layers during cleansing. The clinical evaluation on 467 3-Dimensional band view images was conducted by the abdominal radiologist using four grading levels of cleansing quality with five causes of low quality EC. The amount of the remaining artifacts at T-junctions was approximated from the results of EC prop . The results from EC prop were compared with the results from syngo.via Client 3.0 Software, EC syngo , and the fast three-material modeling, EC prev , using the preference of the radiologist. Two-tailed paired Wilcoxon signed rank test is used to indicate statistical significance.

Results

The average grade on cleansing quality is 2.89 out of 4. The artifacts at T-junctions from 86.94% of the test images can be removed, whereas artifacts at T-junctions from only 13.06% of the test images cannot be removed. For 13.06% of the test images, the results from EC prop are more preferable to the results from EC syngo (p<0.008). For all the test images, the results from EC prop are more preferable to the results from EC prev (p<0.001). Finally, the visual assessment shows that EC prop can preserve ATT layers, submerged polyps and folds while EC prev can preserve only submerged folds but fails to preserve ATT layers.

Conclusion

From our implementation, EC prop can improve the performance of the existing EC, such that it can preserve ST, especially ATT layers and remove the artifacts at T-junctions which have never been proposed by any other methods before.
Literature
1.
go back to reference Coin CG, Wollett FC, Coin JT, Rowland M, Deramos RK, Dandrea R. Computerized radiology of the colon: A potential screening technique. Comput Radiol. 1983; 7(4):215–21.CrossRefPubMed Coin CG, Wollett FC, Coin JT, Rowland M, Deramos RK, Dandrea R. Computerized radiology of the colon: A potential screening technique. Comput Radiol. 1983; 7(4):215–21.CrossRefPubMed
2.
go back to reference Shigeru LH, Muraki S, Kaufman A, Bartz D, He T. Virtual voyage: Interactive naviation in the human colon. In: Proc. ACM SIGGRAPH.New York: ACM Press/Addison-Wesley Publishing Co.: 1997. p. 27–34. Shigeru LH, Muraki S, Kaufman A, Bartz D, He T. Virtual voyage: Interactive naviation in the human colon. In: Proc. ACM SIGGRAPH.New York: ACM Press/Addison-Wesley Publishing Co.: 1997. p. 27–34.
3.
go back to reference Ferrucci JT. Colon cancer screening with virtual colonoscopy:promise, polyps, politics. Amer J Roentgenol. 2001; 177(5):975–88.CrossRef Ferrucci JT. Colon cancer screening with virtual colonoscopy:promise, polyps, politics. Amer J Roentgenol. 2001; 177(5):975–88.CrossRef
4.
go back to reference Morrin MM, LaMont JT. Screening virtual colonoscopy-ready for prime time?N Engl J Med. 2003; 349(23):2261–4.CrossRefPubMed Morrin MM, LaMont JT. Screening virtual colonoscopy-ready for prime time?N Engl J Med. 2003; 349(23):2261–4.CrossRefPubMed
5.
go back to reference Kaufman AE, Lakare S, Kreeger K, Bitter I. Virtual colonscopy. In: Commun ACM. New York: ACM: 2005. p. 37–41. Kaufman AE, Lakare S, Kreeger K, Bitter I. Virtual colonscopy. In: Commun ACM. New York: ACM: 2005. p. 37–41.
6.
go back to reference Society AC. Cancer Facts & Figures. Atlanta: American Cancer Society, Inc; 2013. Society AC. Cancer Facts & Figures. Atlanta: American Cancer Society, Inc; 2013.
7.
go back to reference Institute ITDNC. Hospital-Based Cancer Registry. Bangkok, Thailand: Pornsup Printing CO., LTD; 2015. Institute ITDNC. Hospital-Based Cancer Registry. Bangkok, Thailand: Pornsup Printing CO., LTD; 2015.
8.
go back to reference Hong L, Liang Z, Visawambharant A, Kaufman A, Wax M. Reconstruction and visualization of 3d models of colonic surface. IEEE Trans Nucl Sci. 1997; 44(3):1297–302.CrossRef Hong L, Liang Z, Visawambharant A, Kaufman A, Wax M. Reconstruction and visualization of 3d models of colonic surface. IEEE Trans Nucl Sci. 1997; 44(3):1297–302.CrossRef
9.
go back to reference Serlie I, Vos F, Stoker J, Truyen R, Gerritsen F, Nio Y, Post F. Improved visualization in virtual colonoscopy using image-based rendering. In: Proc IEEE Joint Eurographics TCVG Symp Vis. IEEE Computer Society: 2001. p. 137–46. Serlie I, Vos F, Stoker J, Truyen R, Gerritsen F, Nio Y, Post F. Improved visualization in virtual colonoscopy using image-based rendering. In: Proc IEEE Joint Eurographics TCVG Symp Vis. IEEE Computer Society: 2001. p. 137–46.
10.
go back to reference Hara AK, Johnson CD, Reed JE, Ahlquist DAA, Nelson H, MacCarty RL. Detection of colorectal polyps with ct colonography: Initial assessment of sensitivity and specificity. Radiology. 1997; 205(3):59–65.CrossRefPubMed Hara AK, Johnson CD, Reed JE, Ahlquist DAA, Nelson H, MacCarty RL. Detection of colorectal polyps with ct colonography: Initial assessment of sensitivity and specificity. Radiology. 1997; 205(3):59–65.CrossRefPubMed
11.
go back to reference Fenlon HM, Nunes DP, Schroy PC, Barish MA, Clarke PD, Ferrucci JT. A comparison of virtual and conventonal colonoscopy for the detection of colorectal polyps. N Engl J Med. 1999; 341(20):1496–503.CrossRefPubMed Fenlon HM, Nunes DP, Schroy PC, Barish MA, Clarke PD, Ferrucci JT. A comparison of virtual and conventonal colonoscopy for the detection of colorectal polyps. N Engl J Med. 1999; 341(20):1496–503.CrossRefPubMed
12.
go back to reference Yee J, Akerkar GA, Hung RK, Steinauer-Gebauer AM, Wall SD, McQuaid KR. Colorectal neoplasia: Performance characteristics of ct colonography for detection in 300 patients. Radiology. 2001; 219(3):685–92.CrossRefPubMed Yee J, Akerkar GA, Hung RK, Steinauer-Gebauer AM, Wall SD, McQuaid KR. Colorectal neoplasia: Performance characteristics of ct colonography for detection in 300 patients. Radiology. 2001; 219(3):685–92.CrossRefPubMed
13.
go back to reference Cai W, Zalis ME, Näppi J, Harris GJ, Yoshida H. Structre-analysis method for eletronic cleansing in cathartic and noncathartic ct colonography. Meds Phys. 2008; 35(7):3259–77.CrossRef Cai W, Zalis ME, Näppi J, Harris GJ, Yoshida H. Structre-analysis method for eletronic cleansing in cathartic and noncathartic ct colonography. Meds Phys. 2008; 35(7):3259–77.CrossRef
14.
go back to reference Cai W, JG L, Zalis EM, Yoshida H. Mosaic decomposition: An electronic cleansing method for inhomogeneously tagged regions in noncathartic ct colonography. IEEE Trans Med Imaging. 2010; 30(3):559–74.PubMedPubMedCentral Cai W, JG L, Zalis EM, Yoshida H. Mosaic decomposition: An electronic cleansing method for inhomogeneously tagged regions in noncathartic ct colonography. IEEE Trans Med Imaging. 2010; 30(3):559–74.PubMedPubMedCentral
15.
go back to reference Lee H, Kim B, Lee J, Kim SH, Shin Y, Kim T. Fold-preserving electronic cleansing using a reconstruction model integrating material fractions and structural responses. IEEE Trans Biomed Eng. 2013; 60(6):1546–55.CrossRefPubMed Lee H, Kim B, Lee J, Kim SH, Shin Y, Kim T. Fold-preserving electronic cleansing using a reconstruction model integrating material fractions and structural responses. IEEE Trans Biomed Eng. 2013; 60(6):1546–55.CrossRefPubMed
16.
go back to reference Lee H, Lee J, Kim B, Kim SH, Shin Y. Fast three-material modeling with triple arch projection for electronic cleansing in ctc. IEEE Trans Biomed Eng. 2014; 61(7):2102–11.CrossRefPubMed Lee H, Lee J, Kim B, Kim SH, Shin Y. Fast three-material modeling with triple arch projection for electronic cleansing in ctc. IEEE Trans Biomed Eng. 2014; 61(7):2102–11.CrossRefPubMed
17.
go back to reference Linguraru MG, Panjwani N, Fletcher JG, Summers RM. Automated image-based colon cleansing for laxative-free ct colonography computer-aided polyp detection. Med Phys. 2011; 38(12):6633–42.CrossRefPubMed Linguraru MG, Panjwani N, Fletcher JG, Summers RM. Automated image-based colon cleansing for laxative-free ct colonography computer-aided polyp detection. Med Phys. 2011; 38(12):6633–42.CrossRefPubMed
18.
go back to reference Wang S, Li L, Cohen H, Mankes S, Chen JJ, Liang Z. An em approach to map solution of segmenting tissue mixture percentages with application to ct-based virtual colonoscopy. Med Phys. 2008; 35(12):5787–98.CrossRefPubMedPubMedCentral Wang S, Li L, Cohen H, Mankes S, Chen JJ, Liang Z. An em approach to map solution of segmenting tissue mixture percentages with application to ct-based virtual colonoscopy. Med Phys. 2008; 35(12):5787–98.CrossRefPubMedPubMedCentral
19.
go back to reference Ravestejin VVF, Vos FM, Serlie IWO, Truyen R, van LJ V. Thin layer tissue classification for electronic cleansing of ct colonography data. In: ICPR 2008, 19th International Conference. Washington, D.C: IEEE Computer Society: 2008. p. 137–46. Ravestejin VVF, Vos FM, Serlie IWO, Truyen R, van LJ V. Thin layer tissue classification for electronic cleansing of ct colonography data. In: ICPR 2008, 19th International Conference. Washington, D.C: IEEE Computer Society: 2008. p. 137–46.
20.
go back to reference Serlie IWO, Vos FM, Truyen R, Post FH, Stoker J, Vliet LJV. Electronic cleansing for computed tomography(ct) colonography using a scale-invariant three-material model. IEEE Trans Biomed Eng. 2010; 57(6):1306–17.CrossRefPubMed Serlie IWO, Vos FM, Truyen R, Post FH, Stoker J, Vliet LJV. Electronic cleansing for computed tomography(ct) colonography using a scale-invariant three-material model. IEEE Trans Biomed Eng. 2010; 57(6):1306–17.CrossRefPubMed
21.
go back to reference Ravestejin VVF, Boellaard TN, Paardt VDMP, Serlie WOI, Haan CDM, Stoker J, Vliet JVL, Vos FM. Electronic cleansing for 24-h limited bowel preparation ct colonography using principal curvature flow. IEEE Trans Bio Med Eng. 2013; 60(11):3036–45.CrossRef Ravestejin VVF, Boellaard TN, Paardt VDMP, Serlie WOI, Haan CDM, Stoker J, Vliet JVL, Vos FM. Electronic cleansing for 24-h limited bowel preparation ct colonography using principal curvature flow. IEEE Trans Bio Med Eng. 2013; 60(11):3036–45.CrossRef
22.
go back to reference Lefere PA, Gryspeerdt SS, Dewspelaere J, Baekelandt M, Holsbeeck BGV. Dietary fecal tagging as a cleansing method before ct colonography: Initial result-polyp detection and patient acceptance. Radiology. 2002; 224(2):393–403.CrossRefPubMed Lefere PA, Gryspeerdt SS, Dewspelaere J, Baekelandt M, Holsbeeck BGV. Dietary fecal tagging as a cleansing method before ct colonography: Initial result-polyp detection and patient acceptance. Radiology. 2002; 224(2):393–403.CrossRefPubMed
23.
go back to reference Zalis ME, Blake MA, Cai W. Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymtomatic adults: a prospective evaluation. Ann Intern Med. 2012; 156(10):692–702.CrossRefPubMed Zalis ME, Blake MA, Cai W. Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymtomatic adults: a prospective evaluation. Ann Intern Med. 2012; 156(10):692–702.CrossRefPubMed
25.
go back to reference Pickhardt PJ, Hassan C, Halligan S, Marmo R. Colorectal cancer: ct colonography and colonoscopy for detection-systematic review and meta-analysis. Radiology. 2011; 259(2):393–405.CrossRefPubMedPubMedCentral Pickhardt PJ, Hassan C, Halligan S, Marmo R. Colorectal cancer: ct colonography and colonoscopy for detection-systematic review and meta-analysis. Radiology. 2011; 259(2):393–405.CrossRefPubMedPubMedCentral
26.
go back to reference Nagata K, Endo S, Honda T, Yasuda T, Hirayama M, Takahashi S, Kato T, Horita S, Furuya K, Kasai K, Matsumoto H, Kimura Y, Utano K, Suginoto H, Kato H, Yamada R, Yamamichi J, Shimamoto T, Ryu Y, Matsui O, Kondo H, Doi A, Abe T, Yamano OH, Takeuchi K, Hanai H, AGAF, FACG, Saida Y, Fukuda K, Näppi J, Yoshida H. Accuracy of ct colonography for detection of polypoid and nonpolypoid neoplasia by gastroenterologists and radiologists: A nationawide multicenter study in japan. Am J Gastroenterol. 2016; 112:163–71.CrossRefPubMedPubMedCentral Nagata K, Endo S, Honda T, Yasuda T, Hirayama M, Takahashi S, Kato T, Horita S, Furuya K, Kasai K, Matsumoto H, Kimura Y, Utano K, Suginoto H, Kato H, Yamada R, Yamamichi J, Shimamoto T, Ryu Y, Matsui O, Kondo H, Doi A, Abe T, Yamano OH, Takeuchi K, Hanai H, AGAF, FACG, Saida Y, Fukuda K, Näppi J, Yoshida H. Accuracy of ct colonography for detection of polypoid and nonpolypoid neoplasia by gastroenterologists and radiologists: A nationawide multicenter study in japan. Am J Gastroenterol. 2016; 112:163–71.CrossRefPubMedPubMedCentral
30.
go back to reference Näppi J, Yoshida H. Adaptive correction of the pseudo-enhancement of ct attenuation for fecal-tagging ct colonography. Med Image Anal. 2008; 12:413–26.CrossRefPubMedPubMedCentral Näppi J, Yoshida H. Adaptive correction of the pseudo-enhancement of ct attenuation for fecal-tagging ct colonography. Med Image Anal. 2008; 12:413–26.CrossRefPubMedPubMedCentral
31.
go back to reference Tsagaan B, Näppi J, Yoshida H. Nonlinear regression-based method for pseudoenhancement correction in ct colonography. Med Phys. 2009; 36(8):3596–606.CrossRefPubMedPubMedCentral Tsagaan B, Näppi J, Yoshida H. Nonlinear regression-based method for pseudoenhancement correction in ct colonography. Med Phys. 2009; 36(8):3596–606.CrossRefPubMedPubMedCentral
32.
33.
go back to reference Chen Y, Zhang Y, Yang J, Cao Q, Yang G, Chen J, Huazhong S, Luo L, Coatrieux J, Feng Q. Curve-like structure extraction using minimal path propagation with backtracking. IEEE Trans Image Proc. 2016; 25(2):988–1003.CrossRef Chen Y, Zhang Y, Yang J, Cao Q, Yang G, Chen J, Huazhong S, Luo L, Coatrieux J, Feng Q. Curve-like structure extraction using minimal path propagation with backtracking. IEEE Trans Image Proc. 2016; 25(2):988–1003.CrossRef
34.
go back to reference Serlie IWO, Vos FM, Truyen R, Post FH, Vliet LJV. Classifying ct image data into material fractions by a scale and rotation invariant edge model. IEEE Trans Image Process. 2007; 16(12):2891–904.CrossRefPubMed Serlie IWO, Vos FM, Truyen R, Post FH, Vliet LJV. Classifying ct image data into material fractions by a scale and rotation invariant edge model. IEEE Trans Image Process. 2007; 16(12):2891–904.CrossRefPubMed
35.
go back to reference Zhang Y, Zhang Y, Lv YD, Hou XX, Liu FY, Jia WJ, Yang MM, Phillips P, Wang SH. Alcoholism detection by medical robots based on hu moment invariants and predator-prey adaptive-inertia chaotic particle swarm optimization. IEEE Trans Image Proc. 2017. doi:10.1016/j.compeleceng.2017.04.009. Zhang Y, Zhang Y, Lv YD, Hou XX, Liu FY, Jia WJ, Yang MM, Phillips P, Wang SH. Alcoholism detection by medical robots based on hu moment invariants and predator-prey adaptive-inertia chaotic particle swarm optimization. IEEE Trans Image Proc. 2017. doi:10.​1016/​j.​compeleceng.​2017.​04.​009.
36.
go back to reference Chen Y, Yang J, Zhang Y, Huazhong S, Luo L, Coatrieux J, Feng Q. Structure-adaptive fuzzy estimation for random-value impulse noise suppression. IEEE Trans Circ Syst Video Technol. 2016. doi:10.1109/TCSVT.2016.2615444. Chen Y, Yang J, Zhang Y, Huazhong S, Luo L, Coatrieux J, Feng Q. Structure-adaptive fuzzy estimation for random-value impulse noise suppression. IEEE Trans Circ Syst Video Technol. 2016. doi:10.​1109/​TCSVT.​2016.​2615444.
37.
go back to reference Pickhardt PJ, Choi JR, Hwang I, Butler JA, Puckett ML, Hildebrandt H, K WR, Nugent PA, Mysliwiec PA, Schindler WR. Computer tomographic vitual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N Engl J Med. 2003; 349(23):2191–200.CrossRefPubMed Pickhardt PJ, Choi JR, Hwang I, Butler JA, Puckett ML, Hildebrandt H, K WR, Nugent PA, Mysliwiec PA, Schindler WR. Computer tomographic vitual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N Engl J Med. 2003; 349(23):2191–200.CrossRefPubMed
38.
go back to reference Adalsteinsson D, Sethian JA. A fast level set method for propagating interfaces. J Comput Phys. 1995; 118(2):269–277.CrossRef Adalsteinsson D, Sethian JA. A fast level set method for propagating interfaces. J Comput Phys. 1995; 118(2):269–277.CrossRef
Metadata
Title
Electronic cleansing in computed tomography colonography using AT layer identification with integration of gradient directional second derivative and material fraction model
Authors
Krisorn Chunhapongpipat
Ratinan Boonklurb
Bundit Chaopathomkul
Sirod Sirisup
Rajalida Lipikorn
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2017
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-017-0224-6

Other articles of this Issue 1/2017

BMC Medical Imaging 1/2017 Go to the issue