Abstract

Purpose

Comparison of imaging measurement devices in the absence of a gold-standard comparator remains a vexing problem; especially in scenarios where multiple, non-paired, replicated measurements occur, as in image-guided radiotherapy (IGRT). As the number of commercially available IGRT presents a challenge to determine whether different IGRT methods may be used interchangeably, an unmet need conceptually parsimonious and statistically robust method to evaluate the agreement between two methods with replicated observations. Consequently, we sought to determine, using an previously reported head and neck positional verification dataset, the feasibility and utility of a Comparison of Measurement Methods with the Mixed Effects Procedure Accounting for Replicated Evaluations (COM3PARE), a unified conceptual schema and analytic algorithm based upon Roy’s linear mixed effects (LME) model with Kronecker product covariance structure in a doubly multivariate set-up, for IGRT method comparison.

Methods

An anonymized dataset consisting of 100 paired coordinate (X/ measurements from a sequential series of head and neck cancer patients imaged near-simultaneously with cone beam CT (CBCT) and kilovoltage X-ray (KVX) imaging was used for model implementation. Software-suggested CBCT and KVX shifts for the lateral (X), vertical (Y) and longitudinal (Z) dimensions were evaluated for bias, inter-method (between-subject variation), intra-method (within-subject variation), and overall agreement using with a script implementing COM3PARE with the MIXED procedure of the statistical software package SAS (SAS Institute, Cary, NC, USA).

Results

COM3PARE showed statistically significant bias agreement and difference in inter-method between CBCT and KVX was observed in the Z-axis (both p − value<0.01). Intra-method and overall agreement differences were noted as statistically significant for both the X- and Z-axes (all p − value<0.01). Using pre-specified criteria, based on intra-method agreement, CBCT was deemed preferable for X-axis positional verification, with KVX preferred for superoinferior alignment.

Conclusions

The COM3PARE methodology was validated as feasible and useful in this pilot head and neck cancer positional verification dataset. COM3PARE represents a flexible and robust standardized analytic methodology for IGRT comparison. The implemented SAS script is included to encourage other groups to implement COM3PARE in other anatomic sites or IGRT platforms.
Literature
1.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1:307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1:307–10.CrossRefPubMed
2.
go back to reference Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995; 346:1085–7.CrossRefPubMed Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995; 346:1085–7.CrossRefPubMed
3.
go back to reference Bland JM, Altman DG. Comparing two methods of clinical measurement: a personal history. Int J Epidemiol. 1995; 24(Suppl 1):S7–14.CrossRefPubMed Bland JM, Altman DG. Comparing two methods of clinical measurement: a personal history. Int J Epidemiol. 1995; 24(Suppl 1):S7–14.CrossRefPubMed
4.
go back to reference Bland JM, Altman DG. Measurement error. BMJ (Clinical research ed.) 1996; 312:1654.CrossRef Bland JM, Altman DG. Measurement error. BMJ (Clinical research ed.) 1996; 312:1654.CrossRef
5.
go back to reference Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8:135–60.CrossRefPubMed Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8:135–60.CrossRefPubMed
6.
go back to reference Bland JM, Altman DG. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003; 22:85–93.CrossRefPubMed Bland JM, Altman DG. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003; 22:85–93.CrossRefPubMed
7.
go back to reference Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007; 17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007; 17:571–82.CrossRefPubMed
8.
go back to reference Bisdas S, Konstantinou G, Surlan-Popovic K, Khoshneviszadeh A, Baghi M, Vogl TJ, et al. Dynamic contrast-enhanced CT of head and neck tumors: comparison of first-pass and permeability perfusion measurements using two different commercially available tracer kinetics models. Acad Radiol. 2008; 15:1580–9.CrossRefPubMed Bisdas S, Konstantinou G, Surlan-Popovic K, Khoshneviszadeh A, Baghi M, Vogl TJ, et al. Dynamic contrast-enhanced CT of head and neck tumors: comparison of first-pass and permeability perfusion measurements using two different commercially available tracer kinetics models. Acad Radiol. 2008; 15:1580–9.CrossRefPubMed
9.
go back to reference Cronin P, Saab A, Kelly AM, Gross BH, Patel S, Kazerooni EA, Carlos RC. Measurements of pulmonary vein ostial diameter and distance to first bifurcation: A comparison of different measurement methods. Eur J Radiol. 2009; 71(1):61–8.CrossRefPubMed Cronin P, Saab A, Kelly AM, Gross BH, Patel S, Kazerooni EA, Carlos RC. Measurements of pulmonary vein ostial diameter and distance to first bifurcation: A comparison of different measurement methods. Eur J Radiol. 2009; 71(1):61–8.CrossRefPubMed
10.
go back to reference Kanza RE, Higashino H, Kido T, Kurata A, Saito M, Sugawara Y, Mochizuki T. Quantitative assessment of regional left ventricular wall thickness and thickening using 16 multidetector-row computed tomography: comparison with cine magnetic resonance imaging. Radiat Med. 2007; 25:119–26.CrossRefPubMed Kanza RE, Higashino H, Kido T, Kurata A, Saito M, Sugawara Y, Mochizuki T. Quantitative assessment of regional left ventricular wall thickness and thickening using 16 multidetector-row computed tomography: comparison with cine magnetic resonance imaging. Radiat Med. 2007; 25:119–26.CrossRefPubMed
11.
go back to reference Kwee TC, Takahara T, Koh DM, Nievelstein RA, Luijten PR. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging. 2008; 28:1141–8.CrossRefPubMed Kwee TC, Takahara T, Koh DM, Nievelstein RA, Luijten PR. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging. 2008; 28:1141–8.CrossRefPubMed
12.
go back to reference Mahnken AH, Spuentrup E, Niethammer M, Buecker A, Boese J, Wildberger JE Flohr T, et al. Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol. 2003; 44:604–11.CrossRefPubMed Mahnken AH, Spuentrup E, Niethammer M, Buecker A, Boese J, Wildberger JE Flohr T, et al. Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol. 2003; 44:604–11.CrossRefPubMed
13.
go back to reference Martin KE, Helvie MA, Zhou C, Roubidoux MA, Bailey JE, Paramagul C, et al. Mammographic density measured with quantitative computer-aided method: comparison with radiologists’ estimates and BI-RADS categories. Radiology. 2006; 240:656–65.CrossRefPubMed Martin KE, Helvie MA, Zhou C, Roubidoux MA, Bailey JE, Paramagul C, et al. Mammographic density measured with quantitative computer-aided method: comparison with radiologists’ estimates and BI-RADS categories. Radiology. 2006; 240:656–65.CrossRefPubMed
14.
go back to reference Murakami R, Uozumi H, Hirai T, Nishimura R, Katsuragawa S, Shiraishi S, Toya R, Tashiro K, Kawanaka K, Oya N, Tomiguchi S, Yamashita Y. Impact of FDG-PET/CT fused imaging on tumor volume assessment of head-and-neck squamous cell carcinoma: intermethod and interobserver variations. Acta Radiol. 2008; 49:693–9.CrossRefPubMed Murakami R, Uozumi H, Hirai T, Nishimura R, Katsuragawa S, Shiraishi S, Toya R, Tashiro K, Kawanaka K, Oya N, Tomiguchi S, Yamashita Y. Impact of FDG-PET/CT fused imaging on tumor volume assessment of head-and-neck squamous cell carcinoma: intermethod and interobserver variations. Acta Radiol. 2008; 49:693–9.CrossRefPubMed
15.
go back to reference Nieman K, Shapiro MD, Ferencik M, Nomura CH, Abbara S, Hoffmann U, et al. Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging. Radiology. 2008; 247:49–56.CrossRefPubMed Nieman K, Shapiro MD, Ferencik M, Nomura CH, Abbara S, Hoffmann U, et al. Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging. Radiology. 2008; 247:49–56.CrossRefPubMed
16.
go back to reference Agazaryan N, Tenn SE, Desalles AA, Selch MT. Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motion. Phys Med Biol. 2008; 53:1715–27.CrossRefPubMed Agazaryan N, Tenn SE, Desalles AA, Selch MT. Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motion. Phys Med Biol. 2008; 53:1715–27.CrossRefPubMed
17.
go back to reference Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. J Clin Oncol. 2007; 25:938–946.CrossRefPubMed Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. J Clin Oncol. 2007; 25:938–946.CrossRefPubMed
18.
go back to reference Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008; 70:1045–56.CrossRefPubMed Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008; 70:1045–56.CrossRefPubMed
19.
go back to reference Ippolito E, Mertens I, Haustermans K, Gambacorta MA, Pasini D, Valentini V. IGRT in rectal cancer. Acta oncologica (Stockholm, Sweden). 2008; 47:1317–24.CrossRef Ippolito E, Mertens I, Haustermans K, Gambacorta MA, Pasini D, Valentini V. IGRT in rectal cancer. Acta oncologica (Stockholm, Sweden). 2008; 47:1317–24.CrossRef
20.
go back to reference Kupelian PA, Langen KM, Willoughby TR, Zeidan OA, Meeks SL. Image-guided radiotherapy for localized prostate cancer: treating a moving target. Semin Radiat Oncol. 2008; 18:58–66.CrossRefPubMed Kupelian PA, Langen KM, Willoughby TR, Zeidan OA, Meeks SL. Image-guided radiotherapy for localized prostate cancer: treating a moving target. Semin Radiat Oncol. 2008; 18:58–66.CrossRefPubMed
21.
go back to reference Wertz H, Lohr F, Dobler B, Mai S, Wenz F. Dosimetric impact of image-guided translational isocenter correction for 3-D conformal radiotherapy of the prostate. Strahlenther Onkol. 2007; 183:203–10.CrossRefPubMed Wertz H, Lohr F, Dobler B, Mai S, Wenz F. Dosimetric impact of image-guided translational isocenter correction for 3-D conformal radiotherapy of the prostate. Strahlenther Onkol. 2007; 183:203–10.CrossRefPubMed
23.
go back to reference Yorke ED, Keall P, Verhaegen F. Anniversary paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision. Med Phys. 2008; 35:828–39.CrossRefPubMed Yorke ED, Keall P, Verhaegen F. Anniversary paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision. Med Phys. 2008; 35:828–39.CrossRefPubMed
24.
go back to reference Fuller CD, Thomas CR, Schwartz S, Golden N, Ting J, Wong A, et al. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting. Phys Med Biol. 2006; 51:4981–93.CrossRefPubMed Fuller CD, Thomas CR, Schwartz S, Golden N, Ting J, Wong A, et al. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting. Phys Med Biol. 2006; 51:4981–93.CrossRefPubMed
25.
go back to reference Moseley DJ, White EA, Wiltshire KL, Rosewall T, Sharpe MB, Siewerdsen JH, et al. Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys. 2007; 67:942–53.CrossRefPubMedPubMedCentral Moseley DJ, White EA, Wiltshire KL, Rosewall T, Sharpe MB, Siewerdsen JH, et al. Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys. 2007; 67:942–53.CrossRefPubMedPubMedCentral
26.
go back to reference Artignan X, Smitsmans MH, Lebesque JV, Jaffray DA, van Her M, Bartelink H. Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement. Int J Radiat Oncol Biol Phys. 2004; 59:595–601.CrossRefPubMed Artignan X, Smitsmans MH, Lebesque JV, Jaffray DA, van Her M, Bartelink H. Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement. Int J Radiat Oncol Biol Phys. 2004; 59:595–601.CrossRefPubMed
27.
go back to reference Cury FL, Shenouda G, Souhami L, Duclos M, Faria SL, David M, et al. Ultrasound-based image guided radiotherapy for prostate cancer: comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy. Int J. Radiat Oncol Biol Phys. 2006; 66:1562–7.CrossRefPubMed Cury FL, Shenouda G, Souhami L, Duclos M, Faria SL, David M, et al. Ultrasound-based image guided radiotherapy for prostate cancer: comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy. Int J. Radiat Oncol Biol Phys. 2006; 66:1562–7.CrossRefPubMed
28.
go back to reference Fung AY, Ayyangar KM, Djajaputra D, Nehru RM, Enke CA. Ultrasound-based guidance of intensity-modulated radiation therapy. NMed Dosim. 2006; 31:20–9.CrossRef Fung AY, Ayyangar KM, Djajaputra D, Nehru RM, Enke CA. Ultrasound-based guidance of intensity-modulated radiation therapy. NMed Dosim. 2006; 31:20–9.CrossRef
29.
go back to reference Fuss M, Salter BJ, Cavanaugh SX, Fuss C, Sadeghi A, Fuller CD, et al. Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies. Int J Radiat Oncol Biol Phys. 2004; 59:1245–56.CrossRefPubMed Fuss M, Salter BJ, Cavanaugh SX, Fuss C, Sadeghi A, Fuller CD, et al. Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies. Int J Radiat Oncol Biol Phys. 2004; 59:1245–56.CrossRefPubMed
30.
go back to reference Langen KM, Pouliot J, Anezinos C, Aubin M, Gottschalk AR, Hsu IC, et al. Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J. Radiat Oncol Biol Phys. 2003; 57:635–44.CrossRefPubMed Langen KM, Pouliot J, Anezinos C, Aubin M, Gottschalk AR, Hsu IC, et al. Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J. Radiat Oncol Biol Phys. 2003; 57:635–44.CrossRefPubMed
31.
go back to reference Patel RR, Orton N, Tome WA, Chappell R, Ritter MA. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer. Radiother Oncol. 2003; 67:285–94.CrossRefPubMed Patel RR, Orton N, Tome WA, Chappell R, Ritter MA. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer. Radiother Oncol. 2003; 67:285–94.CrossRefPubMed
32.
go back to reference Choi M, Fuller CD, Wang SJ, Siddiqi A, Wong A, Thomas Jr CR, Fuss M. Effect of body mass index on shifts in ultrasound-based image-guided intensity-modulated radiation therapy for abdominal malignancies. Radiother Oncol. 2009; 91(1):114–9.CrossRefPubMed Choi M, Fuller CD, Wang SJ, Siddiqi A, Wong A, Thomas Jr CR, Fuss M. Effect of body mass index on shifts in ultrasound-based image-guided intensity-modulated radiation therapy for abdominal malignancies. Radiother Oncol. 2009; 91(1):114–9.CrossRefPubMed
33.
go back to reference Gayou O, Miften M. Comparison of mega-voltage cone-beam computed tomography prostate localization with online ultrasound and fiducial markers methods. Med Phys. 2008; 35:531–8.CrossRefPubMed Gayou O, Miften M. Comparison of mega-voltage cone-beam computed tomography prostate localization with online ultrasound and fiducial markers methods. Med Phys. 2008; 35:531–8.CrossRefPubMed
34.
go back to reference Johnston H, Hilts M, Beckham W, Berthelet E. 3D ultrasound for prostate localization in radiation therapy: a comparison with implanted fiducial markers. Med Phys. 2008; 35:2403–13.CrossRefPubMed Johnston H, Hilts M, Beckham W, Berthelet E. 3D ultrasound for prostate localization in radiation therapy: a comparison with implanted fiducial markers. Med Phys. 2008; 35:2403–13.CrossRefPubMed
35.
go back to reference Aubry JF, Beaulieu L, Girouard LM, Aubin S, Tremblay D, Laverdiere J, et al. Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. Int J Radiat Oncol Biol Phys. 2004; 60:30–9.CrossRefPubMed Aubry JF, Beaulieu L, Girouard LM, Aubin S, Tremblay D, Laverdiere J, et al. Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. Int J Radiat Oncol Biol Phys. 2004; 60:30–9.CrossRefPubMed
36.
go back to reference Balter JM, Sandler HM, Lam K, Bree RL, Lichter AS, Haken TENRK. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Biol Phys. 1995; 31:113–8.CrossRefPubMed Balter JM, Sandler HM, Lam K, Bree RL, Lichter AS, Haken TENRK. Measurement of prostate movement over the course of routine radiotherapy using implanted markers. Int J Radiat Oncol Biol Phys. 1995; 31:113–8.CrossRefPubMed
38.
go back to reference Lometti MW, Thurston D, Aubin M, Bock A, Verhey L, Lockhart JM, Bland R, Pouliot J, Roach 3rd M. Are lateral electronic portal images adequate for accurate on-line daily targeting of the prostate? Results of a prospective study. Med Dosim. 2008; 33:22–9. Lometti MW, Thurston D, Aubin M, Bock A, Verhey L, Lockhart JM, Bland R, Pouliot J, Roach 3rd M. Are lateral electronic portal images adequate for accurate on-line daily targeting of the prostate? Results of a prospective study. Med Dosim. 2008; 33:22–9.
39.
go back to reference Sornsen de Kostevan JR, Cuijpers JP, Geest de FG, Lagerwaard FJ, Slotman BJ, Senan S. Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study. adiat Oncol (London, England). 2007; 2:32.CrossRef Sornsen de Kostevan JR, Cuijpers JP, Geest de FG, Lagerwaard FJ, Slotman BJ, Senan S. Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study. adiat Oncol (London, England). 2007; 2:32.CrossRef
40.
go back to reference Morin O, Gillis A, Chen J, Aubin M, Bucci MK, Roach 3rd M, et al. Megavoltage cone-beam CT: system description and clinical applications. Med Dosim. 2006; 31:51–61. Morin O, Gillis A, Chen J, Aubin M, Bucci MK, Roach 3rd M, et al. Megavoltage cone-beam CT: system description and clinical applications. Med Dosim. 2006; 31:51–61.
41.
go back to reference Pang G, Bani-Hashemi A, Au P, O’Brien PF, Rowlands JA, Morton G, et al. Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system. Phys Med Biol. 2008; 53:999–1013.CrossRefPubMed Pang G, Bani-Hashemi A, Au P, O’Brien PF, Rowlands JA, Morton G, et al. Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system. Phys Med Biol. 2008; 53:999–1013.CrossRefPubMed
42.
go back to reference Pisani L, Lockman D, Jaffray D, Yan D, Martinez A, Wong J. Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs. Int J Radiat Oncol Biol Phys. 2000; 47:825–39.CrossRefPubMed Pisani L, Lockman D, Jaffray D, Yan D, Martinez A, Wong J. Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs. Int J Radiat Oncol Biol Phys. 2000; 47:825–39.CrossRefPubMed
43.
go back to reference Pouliot J, Bani-Hashemi A, Chen J, Svatos M, Ghelmansarai F, Mitschke M, et al. Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys. 2005; 61:552–60.CrossRefPubMed Pouliot J, Bani-Hashemi A, Chen J, Svatos M, Ghelmansarai F, Mitschke M, et al. Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys. 2005; 61:552–60.CrossRefPubMed
44.
go back to reference Serago CF, Buskirk SJ, Igel TC, Gale AA, Serago NE, Earle JD. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer. Int J Radiat Oncol Biol Phys. 2006; 65:1585–92.CrossRefPubMed Serago CF, Buskirk SJ, Igel TC, Gale AA, Serago NE, Earle JD. Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer. Int J Radiat Oncol Biol Phys. 2006; 65:1585–92.CrossRefPubMed
45.
go back to reference Wu QJ, Godfrey DJ, Wang Z, Zhang J, Zhou S, Yoo S, Brizel DM, Yin FF. On-board patient positioning for head-and-neck IMRT: comparing digital tomosynthesis to kilovoltage radiography and cone-beam computed tomography. Int J Radiat Oncol Biol Phys. 2007; 69:598–606.CrossRefPubMed Wu QJ, Godfrey DJ, Wang Z, Zhang J, Zhou S, Yoo S, Brizel DM, Yin FF. On-board patient positioning for head-and-neck IMRT: comparing digital tomosynthesis to kilovoltage radiography and cone-beam computed tomography. Int J Radiat Oncol Biol Phys. 2007; 69:598–606.CrossRefPubMed
46.
go back to reference Scarbrough TJ, Golden NM, Ting JY, Fuller CD, Wong A, Kupelian PA, Thomas Jr CR. Comparison of ultrasound and implanted seed marker prostate localization methods: Implications for image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2006; 65:378–87.CrossRefPubMed Scarbrough TJ, Golden NM, Ting JY, Fuller CD, Wong A, Kupelian PA, Thomas Jr CR. Comparison of ultrasound and implanted seed marker prostate localization methods: Implications for image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2006; 65:378–87.CrossRefPubMed
47.
go back to reference Stutzel J, Oelfke U, Nill S. A quantitative image quality comparison of four different image guided radiotherapy devices. Radiother Oncol. 2008; 86:20–4.CrossRefPubMed Stutzel J, Oelfke U, Nill S. A quantitative image quality comparison of four different image guided radiotherapy devices. Radiother Oncol. 2008; 86:20–4.CrossRefPubMed
48.
go back to reference Roy A. An application of linear mixed effects model to assess the agreement between two methods with replicated observations. J Biopharm Stat. 2009; 19:150–73.CrossRefPubMed Roy A. An application of linear mixed effects model to assess the agreement between two methods with replicated observations. J Biopharm Stat. 2009; 19:150–73.CrossRefPubMed
49.
go back to reference Barnhart HX, Haber MJ, Lin LI. An overview on assessing agreement with continuous measurements. J Biopharm Stat. 2007; 17:529–69.CrossRefPubMed Barnhart HX, Haber MJ, Lin LI. An overview on assessing agreement with continuous measurements. J Biopharm Stat. 2007; 17:529–69.CrossRefPubMed
50.
go back to reference Fuller CD, Scarbrough TJ, Sonke JJ, Rasch CR, Choi M, Ting JY, et al. Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis. Phys Med Biol. 2009; 54:7401–15.CrossRefPubMed Fuller CD, Scarbrough TJ, Sonke JJ, Rasch CR, Choi M, Ting JY, et al. Method comparison of automated matching software-assisted cone-beam CT and stereoscopic kilovoltage x-ray positional verification image-guided radiation therapy for head and neck cancer: a prospective analysis. Phys Med Biol. 2009; 54:7401–15.CrossRefPubMed
51.
go back to reference Kenward MG, Roger JH. Small sample inference for fixed effects from restricted maximum likelihood. Biometrics. 1997; 53:983–997.CrossRefPubMed Kenward MG, Roger JH. Small sample inference for fixed effects from restricted maximum likelihood. Biometrics. 1997; 53:983–997.CrossRefPubMed
52.
go back to reference Roy A. Estimating correlation coefficient between two variables with repeated observations using mixed effects model. Biometrical J. 2006; 48:286–301.CrossRef Roy A. Estimating correlation coefficient between two variables with repeated observations using mixed effects model. Biometrical J. 2006; 48:286–301.CrossRef
53.
go back to reference Cui Y, Galvin JM, Straube WL, Bosch WR, Purdy JA, Li XA, Xiao Y. Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials. Int J Radiat Oncol Biol Phys. 2011; 81(1):305–312.CrossRefPubMedPubMedCentral Cui Y, Galvin JM, Straube WL, Bosch WR, Purdy JA, Li XA, Xiao Y. Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials. Int J Radiat Oncol Biol Phys. 2011; 81(1):305–312.CrossRefPubMedPubMedCentral
54.
go back to reference Mohammed N, Kestin L, Grills I, Shah C, Glide-Hurst C, Yan D, et al. Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course. Int J Radiat Oncol Biol Phys. 2012; 82(4):1541–8.CrossRefPubMed Mohammed N, Kestin L, Grills I, Shah C, Glide-Hurst C, Yan D, et al. Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course. Int J Radiat Oncol Biol Phys. 2012; 82(4):1541–8.CrossRefPubMed
55.
go back to reference Shi W, Li JG, Zlotecki RA, Yeung A, Newlin H, Palta J, et al. Evaluation of kV cone-beam ct performance for prostate IGRT: a comparison of automatic grey-value alignment to implanted fiducial-marker alignment. Am J Clin Oncol. 2011; 34(1):16–21.CrossRefPubMed Shi W, Li JG, Zlotecki RA, Yeung A, Newlin H, Palta J, et al. Evaluation of kV cone-beam ct performance for prostate IGRT: a comparison of automatic grey-value alignment to implanted fiducial-marker alignment. Am J Clin Oncol. 2011; 34(1):16–21.CrossRefPubMed
56.
go back to reference Thongphiew D, Wu QJ, Lee WR, Chankong V, Yoo S, McMahon R, Yin FF. Comparison of online IGRT techniques for prostate IMRT treatment: adaptive vs repositioning correction. Med Phys. 2009; 36:1651–62.CrossRefPubMed Thongphiew D, Wu QJ, Lee WR, Chankong V, Yoo S, McMahon R, Yin FF. Comparison of online IGRT techniques for prostate IMRT treatment: adaptive vs repositioning correction. Med Phys. 2009; 36:1651–62.CrossRefPubMed
57.
go back to reference Borst GR, Sonke JJ, Betgen A, Remeijer P, Herk van M, Lebesque JV. Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys. 2007; 68:555–61.CrossRefPubMed Borst GR, Sonke JJ, Betgen A, Remeijer P, Herk van M, Lebesque JV. Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oncol Biol Phys. 2007; 68:555–61.CrossRefPubMed
58.
go back to reference Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989; 45:255–68.CrossRefPubMed Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989; 45:255–68.CrossRefPubMed
59.
go back to reference Konings H. Use of Deming regression in method-comparison studies. Surv Immunol Res. 1982; 1:371–74.PubMed Konings H. Use of Deming regression in method-comparison studies. Surv Immunol Res. 1982; 1:371–74.PubMed
60.
go back to reference Martin RF. General deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clinical Chem. 2000; 46:100–4. Martin RF. General deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clinical Chem. 2000; 46:100–4.
61.
go back to reference Milliken G, Graybill F. Extensions of the General Linear Hypothesis Model. J Am Stat Assoc. 1970; 65:797–807.CrossRef Milliken G, Graybill F. Extensions of the General Linear Hypothesis Model. J Am Stat Assoc. 1970; 65:797–807.CrossRef
62.
go back to reference LaMotte L. A Canonical Form for the General Linear Model. Ann Stat. 1977; 5:787–9.CrossRef LaMotte L. A Canonical Form for the General Linear Model. Ann Stat. 1977; 5:787–9.CrossRef
63.
go back to reference Fennessey J. The General Linear Model: A New Perspective on Some Familiar Topics. Am J Sociol. 1968; 74:1–27.CrossRef Fennessey J. The General Linear Model: A New Perspective on Some Familiar Topics. Am J Sociol. 1968; 74:1–27.CrossRef
Metadata
Title
Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM3PARE): method comparison algorithm implementation for head and neck IGRT positional verification
Authors
Anuradha Roy
Clifton D. Fuller
David I. Rosenthal
Charles R. Thomas Jr.
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2015
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-015-0074-z

Other articles of this Issue 1/2015

BMC Medical Imaging 1/2015 Go to the issue