Skip to main content
Top
Published in: BMC Medical Research Methodology 1/2015

Open Access 01-12-2015 | Research article

Challenges in standardization of blood pressure measurement at the population level

Authors: Hanna Tolonen, Päivikki Koponen, Androniki Naska, Satu Männistö, Grazyna Broda, Tarja Palosaari, Kari Kuulasmaa, for the EHES Pilot Project

Published in: BMC Medical Research Methodology | Issue 1/2015

Login to get access

Abstract

Background

Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed.

Methods

The European Health Examination Survey (EHES) Pilot project was conducted in 2009–2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization.

Results

The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement.

Conclusions

It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rose GA, Khaw K-T, Marmot MG. Rose’s strategy of preventive medicine: the complete original text. New edition. Oxford; New York: Oxford University Press; 2008. Rose GA, Khaw K-T, Marmot MG. Rose’s strategy of preventive medicine: the complete original text. New edition. Oxford; New York: Oxford University Press; 2008.
2.
go back to reference Kawahara J, Sano H, Fukuzaki H, Saito K, Hirouchi H. Acute effects of exposure to cold on blood pressure, platelet function and sympathetic nervous activity in humans. Am J Hypertens. 1989;2(9):724–6.PubMed Kawahara J, Sano H, Fukuzaki H, Saito K, Hirouchi H. Acute effects of exposure to cold on blood pressure, platelet function and sympathetic nervous activity in humans. Am J Hypertens. 1989;2(9):724–6.PubMed
3.
go back to reference Campbell NR, McKay DW, Chockalingam A, Fodor JG. Errors in assessment of blood pressure: patient factors. Can J Public Health. 1994;85 Suppl 2:S12–7.PubMed Campbell NR, McKay DW, Chockalingam A, Fodor JG. Errors in assessment of blood pressure: patient factors. Can J Public Health. 1994;85 Suppl 2:S12–7.PubMed
6.
go back to reference Gould BA, Hornung RS, Kieso HA, Altman DG, Raftery EB. Is the blood pressure the same in both arms? Clin Cardiol. 1985;8(8):423–6.PubMed Gould BA, Hornung RS, Kieso HA, Altman DG, Raftery EB. Is the blood pressure the same in both arms? Clin Cardiol. 1985;8(8):423–6.PubMed
7.
go back to reference Jamieson MJ, Webster J, Philips S, Jeffers TA, Scott AK, Robb OJ, et al. The measurement of blood pressure: sitting or supine, once or twice? J Hypertens. 1990;8(7):635–40.PubMed Jamieson MJ, Webster J, Philips S, Jeffers TA, Scott AK, Robb OJ, et al. The measurement of blood pressure: sitting or supine, once or twice? J Hypertens. 1990;8(7):635–40.PubMed
8.
go back to reference Keele-Smith R, Price-Daniel C. Effects of crossing legs on blood pressure measurement. Clin Nurs Res. 2001;10(2):202–13.PubMed Keele-Smith R, Price-Daniel C. Effects of crossing legs on blood pressure measurement. Clin Nurs Res. 2001;10(2):202–13.PubMed
9.
go back to reference Netea RT, Lenders JW, Smits P, Thien T. Arm position is important for blood pressure measurement. J Hum Hypertens. 1999;13(2):105–9.PubMed Netea RT, Lenders JW, Smits P, Thien T. Arm position is important for blood pressure measurement. J Hum Hypertens. 1999;13(2):105–9.PubMed
10.
go back to reference Netea RT, Smits P, Lenders JW, Thien T. Does it matter whether blood pressure measurements are taken with subjects sitting or supine? J Hypertens. 1998;16(3):263–8.PubMed Netea RT, Smits P, Lenders JW, Thien T. Does it matter whether blood pressure measurements are taken with subjects sitting or supine? J Hypertens. 1998;16(3):263–8.PubMed
11.
go back to reference O’Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, Mancia G, et al. European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens. 2003;21(5):821–48.PubMed O’Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, Mancia G, et al. European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens. 2003;21(5):821–48.PubMed
12.
go back to reference Schulze MB, Kroke A, Saracci R, Boeing H. The effect of differences in measurement procedure on the comparability of blood pressure estimates in multi-centre studies. Blood Press Monit. 2002;7(2):95–104.PubMed Schulze MB, Kroke A, Saracci R, Boeing H. The effect of differences in measurement procedure on the comparability of blood pressure estimates in multi-centre studies. Blood Press Monit. 2002;7(2):95–104.PubMed
13.
go back to reference O’Brien E, Petrie J, Little W, de Swiet M, Padfield P. The British hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11 Suppl 2:S43–62. O’Brien E, Petrie J, Little W, de Swiet M, Padfield P. The British hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11 Suppl 2:S43–62.
14.
go back to reference O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23–38.PubMed O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23–38.PubMed
15.
go back to reference Association for the Advancement of Medical Instrumentation. Non-invasive sphygmomanometers - part 2: clinical validation of automated measurement type. ANSI/AAMI/ISO 81060–2. Association for the Advancement of Medical Instrumentatio, 2013. Association for the Advancement of Medical Instrumentation. Non-invasive sphygmomanometers - part 2: clinical validation of automated measurement type. ANSI/AAMI/ISO 81060–2. Association for the Advancement of Medical Instrumentatio, 2013.
16.
go back to reference Mauro AMP. Effects of bell versus diaphragm on indirect blood-pressure measurement. Heart Lung. 1988;17(5):489–94.PubMed Mauro AMP. Effects of bell versus diaphragm on indirect blood-pressure measurement. Heart Lung. 1988;17(5):489–94.PubMed
17.
go back to reference Kantola I, Vesalainen R, Kangassalo K, Kariluoto A. Bell or diaphragm in the measurement of blood pressure? J Hypertens. 2005;23(3):499–503.PubMed Kantola I, Vesalainen R, Kangassalo K, Kariluoto A. Bell or diaphragm in the measurement of blood pressure? J Hypertens. 2005;23(3):499–503.PubMed
18.
go back to reference Coleman AJ, Steel SD, Ashworth M, Vowler SL, Shennan A. Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care. Blood Press Monit. 2005;10(4):181–8.PubMed Coleman AJ, Steel SD, Ashworth M, Vowler SL, Shennan A. Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care. Blood Press Monit. 2005;10(4):181–8.PubMed
19.
go back to reference de Greeff A, Lorde I, Wilton A, Seed P, Coleman AJ, Shennan AH. Calibration accuracy of hospital-based non-invasive blood pressure measuring devices. J Hum Hypertens. 2010;24(1):58–63.PubMed de Greeff A, Lorde I, Wilton A, Seed P, Coleman AJ, Shennan AH. Calibration accuracy of hospital-based non-invasive blood pressure measuring devices. J Hum Hypertens. 2010;24(1):58–63.PubMed
20.
go back to reference Rose G. Standardisation of observers in blood-pressure measurement. Lancet. 1965;1(7387):673–4.PubMed Rose G. Standardisation of observers in blood-pressure measurement. Lancet. 1965;1(7387):673–4.PubMed
21.
go back to reference Beevers G, Lip GY, O’Brien E. ABC of hypertension: blood pressure measurement. Part II-conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ. 2001;322(7293):1043–7.PubMedPubMedCentral Beevers G, Lip GY, O’Brien E. ABC of hypertension: blood pressure measurement. Part II-conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ. 2001;322(7293):1043–7.PubMedPubMedCentral
22.
go back to reference de Lusignan S, Belsey J, Hague N, Dzregah B. End-digit preference in blood pressure recordings of patients with ischaemic heart disease in primary care. J Hum Hypertens. 2004;18(4):261–5.PubMed de Lusignan S, Belsey J, Hague N, Dzregah B. End-digit preference in blood pressure recordings of patients with ischaemic heart disease in primary care. J Hum Hypertens. 2004;18(4):261–5.PubMed
23.
go back to reference Hessel PA. Terminal digit preference in blood pressure measurements: effects on epidemiological associations. Int J Epidemiol. 1986;15(1):122–5.PubMed Hessel PA. Terminal digit preference in blood pressure measurements: effects on epidemiological associations. Int J Epidemiol. 1986;15(1):122–5.PubMed
25.
go back to reference Turner MJ, Baker AB, Kam PC. Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension. Blood Press Monit. 2004;9(5):249–53.PubMed Turner MJ, Baker AB, Kam PC. Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension. Blood Press Monit. 2004;9(5):249–53.PubMed
26.
go back to reference Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension. 2005;45(1):142–61.PubMed Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension. 2005;45(1):142–61.PubMed
28.
go back to reference Luepker RV, Evans A, McKeigue P, Srinath Reddy K. Cardiovascular survey methods. 3rd ed. Geneva: World Health Organization; 2004. Luepker RV, Evans A, McKeigue P, Srinath Reddy K. Cardiovascular survey methods. 3rd ed. Geneva: World Health Organization; 2004.
29.
go back to reference Tolonen H, Koponen P. 5.1 Blood pressure in Tolonen H. (Ed.) EHES manual, part B. Fieldwork procedures. In: Tolonen H, editor. EHES manual, part B fieldwork procedures. Helsinki: National Institute for Health and Welfare; 2013. Tolonen H, Koponen P. 5.1 Blood pressure in Tolonen H. (Ed.) EHES manual, part B. Fieldwork procedures. In: Tolonen H, editor. EHES manual, part B fieldwork procedures. Helsinki: National Institute for Health and Welfare; 2013.
30.
go back to reference Kuulasmaa K, Tolonen H, Koponen P, Kilpelainen K, Avdicova M, Broda G, et al. An overview of the European health examination survey pilot joint action. Arch Public Health. 2012;70(1):20.PubMedPubMedCentral Kuulasmaa K, Tolonen H, Koponen P, Kilpelainen K, Avdicova M, Broda G, et al. An overview of the European health examination survey pilot joint action. Arch Public Health. 2012;70(1):20.PubMedPubMedCentral
31.
go back to reference Tolonen H. EHES manual. Part A. Planning and preparing for the survey. Volume directions 2013_001. Helsinki: National Institute for Health and Welfare; 2013. Tolonen H. EHES manual. Part A. Planning and preparing for the survey. Volume directions 2013_001. Helsinki: National Institute for Health and Welfare; 2013.
32.
go back to reference Tolonen H. EHES manual. Part B. Fieldwork procedures. Volume directions 2013_002. Helsinki: National Institute for Health and Welfare; 2013. Tolonen H. EHES manual. Part B. Fieldwork procedures. Volume directions 2013_002. Helsinki: National Institute for Health and Welfare; 2013.
34.
go back to reference Ataman SL, Cooper R, Rotimi C, McGee D, Osotimehin B, Kadiri S, et al. Standardization of blood pressure measurement in an international comparative study. J Clin Epidemiol. 1996;49(8):869–77.PubMed Ataman SL, Cooper R, Rotimi C, McGee D, Osotimehin B, Kadiri S, et al. Standardization of blood pressure measurement in an international comparative study. J Clin Epidemiol. 1996;49(8):869–77.PubMed
35.
go back to reference Ostchega Y, Prineas RJ, Paulose-Ram R, Grim CM, Willard G, Collins D. National health and nutrition examination survey 1999–2000: effect of observer training and protocol standardization on reducing blood pressure measurement error. J Clin Epidemiol. 2003;56(8):768–74.PubMed Ostchega Y, Prineas RJ, Paulose-Ram R, Grim CM, Willard G, Collins D. National health and nutrition examination survey 1999–2000: effect of observer training and protocol standardization on reducing blood pressure measurement error. J Clin Epidemiol. 2003;56(8):768–74.PubMed
36.
go back to reference Hense HW, Koivisto AM, Kuulasmaa K, Zaborskis A, Kupsc W, Tuomilehto J. Assessment of blood pressure measurement quality in the baseline surveys of the WHO MONICA project. J Hum Hypertens. 1995;9(12):935–46.PubMed Hense HW, Koivisto AM, Kuulasmaa K, Zaborskis A, Kupsc W, Tuomilehto J. Assessment of blood pressure measurement quality in the baseline surveys of the WHO MONICA project. J Hum Hypertens. 1995;9(12):935–46.PubMed
37.
go back to reference O’Brien E, Mee F, Tan KS, Atkins N, Omalley K. Training and assessment of observers for blood-pressure measurement in hypertension research. J Hum Hypertens. 1991;5(1):7–10.PubMed O’Brien E, Mee F, Tan KS, Atkins N, Omalley K. Training and assessment of observers for blood-pressure measurement in hypertension research. J Hum Hypertens. 1991;5(1):7–10.PubMed
38.
go back to reference European Commission. Commission Regulation (EU) No 847/2012 on 19 September 2012 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the registration, evaluation, authorisation and restriction of chemicals (REACH) as regards mercury. In 847/2012. Edited by European Commission. Off J Eur Union, L253, 20.9.2012. European Commission. Commission Regulation (EU) No 847/2012 on 19 September 2012 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the registration, evaluation, authorisation and restriction of chemicals (REACH) as regards mercury. In 847/2012. Edited by European Commission. Off J Eur Union, L253, 20.9.2012.
39.
go back to reference Ostchega Y, Zhang G, Sorlie P, Hughes JP, Reed-Gillette DS, Nwankwo T, et al. Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: national health and nutrition examination survey, 2009–2010. Natl Health Stat Report. 2012: (59):1–15. Ostchega Y, Zhang G, Sorlie P, Hughes JP, Reed-Gillette DS, Nwankwo T, et al. Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: national health and nutrition examination survey, 2009–2010. Natl Health Stat Report. 2012: (59):1–15.
40.
go back to reference Pruijm MT, Wuerzner G, Glatz N, Alwan H, Ponte B, Ackermann D, et al. A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol. Blood Press Monit. 2010;15(6):322–5.PubMed Pruijm MT, Wuerzner G, Glatz N, Alwan H, Ponte B, Ackermann D, et al. A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol. Blood Press Monit. 2010;15(6):322–5.PubMed
41.
go back to reference Stergiou GS, Karpettas N, Kollias A, Destounis A, Tzamouranis D. A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor. J Hum Hypertens. 2012;26(4):220–7.PubMed Stergiou GS, Karpettas N, Kollias A, Destounis A, Tzamouranis D. A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor. J Hum Hypertens. 2012;26(4):220–7.PubMed
42.
go back to reference Frohlich ED, Grim CM, Labarthe DR, Maxwell MH, Perloff D, Weidman WH. Recommendations for human blood pressure determination by sphygmomanometers. Report of a special task force appointed by the steering committee, American Heart Association. Hypertension. 1988;11(2):209A–22A. Frohlich ED, Grim CM, Labarthe DR, Maxwell MH, Perloff D, Weidman WH. Recommendations for human blood pressure determination by sphygmomanometers. Report of a special task force appointed by the steering committee, American Heart Association. Hypertension. 1988;11(2):209A–22A.
43.
go back to reference Fornells JM, Borras JM, Balaguer-Vintro I. The preference for the final digits in blood pressure determination: a continuing education experience. Aten Primaria. 1990;7(2):102–5.PubMed Fornells JM, Borras JM, Balaguer-Vintro I. The preference for the final digits in blood pressure determination: a continuing education experience. Aten Primaria. 1990;7(2):102–5.PubMed
44.
go back to reference Kolb C, Huss R, Mengden T, Vetter W. How reliable is conventional blood pressure registration? Comparison with a semi-automatic device. Schweiz Rundsch Med Prax. 1991;80(12):286–90.PubMed Kolb C, Huss R, Mengden T, Vetter W. How reliable is conventional blood pressure registration? Comparison with a semi-automatic device. Schweiz Rundsch Med Prax. 1991;80(12):286–90.PubMed
45.
go back to reference Tolonen H, Kuulasmaa K, Laatikainen T, Wolf H, the European Health Risk Monitoring Project. Recommendations for indicators, international collaboration, protocol and manual of operations for chronic disease risk factor surveys. Helsinki: Finnish National Public Health Institute; 2002. Tolonen H, Kuulasmaa K, Laatikainen T, Wolf H, the European Health Risk Monitoring Project. Recommendations for indicators, international collaboration, protocol and manual of operations for chronic disease risk factor surveys. Helsinki: Finnish National Public Health Institute; 2002.
Metadata
Title
Challenges in standardization of blood pressure measurement at the population level
Authors
Hanna Tolonen
Päivikki Koponen
Androniki Naska
Satu Männistö
Grazyna Broda
Tarja Palosaari
Kari Kuulasmaa
for the EHES Pilot Project
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Medical Research Methodology / Issue 1/2015
Electronic ISSN: 1471-2288
DOI
https://doi.org/10.1186/s12874-015-0020-3

Other articles of this Issue 1/2015

BMC Medical Research Methodology 1/2015 Go to the issue