Skip to main content
Top
Published in: BMC Anesthesiology 1/2018

Open Access 01-12-2018 | Research article

Ultrasound-guided continuous femoral nerve block: a randomized trial on the influence of femoral nerve catheter orifice configuration (six-hole versus end-hole) on post-operative analgesia after total knee arthroplasty

Authors: Alessandra Novello-Siegenthaler, Mehdi Hamdani, Irène Iselin-Chaves, Roxane Fournier

Published in: BMC Anesthesiology | Issue 1/2018

Login to get access

Abstract

Background

Multiorifice catheters have been shown to provide superior analgesia and significantly reduce local anesthetic consumption compared with end-hole catheters in epidural studies. This prospective, blinded, randomized study tested the hypothesis that, in continuous femoral nerve block (CFNB) under ultrasound guidance, multiorifice catheter would reduce local anesthetic consumption at 24 h compared with end-hole catheter.

Methods

Eighty adult patients (aged ≥18 years) scheduled to undergo primary total knee arthroplasty under a combination of CFNB, sciatic nerve block and general anesthesia were randomized to CFNB using either a 3-pair micro-hole (Contiplex, BRAUN®, 20G - 400 mm) or an end-hole (Silverstim VYGON®, 20G - 500 mm) catheter. Once the femoral catheter was sited, a bolus of 20 mL lidocaine 1% was injected. An electronic pump then delivered an automated 5 mL bolus of ropivacaine 0.2% hourly, with 10 mL self-administered patient controlled analgesia boluses.

Results

There was no inter-group difference in either median number of ropivacaine boluses on demand during the first 24 h (4(2–7) vs. 4(2–8) in six-hole and end-hole groups, respectively; P = 0.832) or median ropivacaine consumption at 48 h (365(295–418) vs. 387(323–466); P = 0.452).
No significant differences were recorded between the groups at 24 h regarding median average verbal rate pain scale (2(0–3) vs. 2(0–4); P = 0.486) or morphine consumption (0(0–20) vs. 0(0–20); P = 0.749). Quadriceps muscle strength declined to 7% (0–20) and 10% (0–28) in the six-hole and end-hole groups, respectively, at 24 h after surgery (P = 0.733).

Conclusions

In this superiority trial, catheter orifice configuration did not influence the effectiveness of CFNB in this setting: quality of analgesia was similar, with no reduction in either local anesthetic or morphine consumption, and equivalent postoperative quadriceps weakness.

Trial registration

Retrospectively registered at (NCT03376178). Date: 21 November 2017.
Literature
1.
go back to reference Paul JE, Arya A, Hurlburt L, Cheng J, Thabane L, Tidy A, Murthy Y. Femoral nerve block improves analgesia outcomes after total knee arthroplasty: a meta-analysis of randomized controlled trials. Anesthesiology. 2010;113:1144–62.CrossRef Paul JE, Arya A, Hurlburt L, Cheng J, Thabane L, Tidy A, Murthy Y. Femoral nerve block improves analgesia outcomes after total knee arthroplasty: a meta-analysis of randomized controlled trials. Anesthesiology. 2010;113:1144–62.CrossRef
2.
go back to reference Lang SA. Postoperative analgesia following total knee arthroplasty: a study comparing spinal anesthesia and combined sciatic femoral 3-in-1 block. Reg Anesth Pain Med. 1999;24:97.CrossRef Lang SA. Postoperative analgesia following total knee arthroplasty: a study comparing spinal anesthesia and combined sciatic femoral 3-in-1 block. Reg Anesth Pain Med. 1999;24:97.CrossRef
3.
go back to reference Farr J, Jaggers R, Lewis H, Plackis A, Sim SB, Sherman SL. Evidence-based approach of treatment options for postoperative knee pain. Phys Sportsmed. 2014;42(2):58–70.CrossRef Farr J, Jaggers R, Lewis H, Plackis A, Sim SB, Sherman SL. Evidence-based approach of treatment options for postoperative knee pain. Phys Sportsmed. 2014;42(2):58–70.CrossRef
4.
go back to reference Mizner RL, Snyder-Mackler L. Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res. 2005;23:1083–90.CrossRef Mizner RL, Snyder-Mackler L. Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res. 2005;23:1083–90.CrossRef
5.
go back to reference Ilfeld BM, Duke KB, Donohue MC. The association between lower extremity continuous peripheral nerve blocks and patient falls after knee and hip arthroplasty. Anesth Analg. 2010;111:1552–4.CrossRef Ilfeld BM, Duke KB, Donohue MC. The association between lower extremity continuous peripheral nerve blocks and patient falls after knee and hip arthroplasty. Anesth Analg. 2010;111:1552–4.CrossRef
6.
go back to reference Brodner G, Buerkle H, Van Aken H, Lambert R, Schweppe-Hartenauer ML, Wempe C, Gogarten W. Postoperative analgesia after knee surgery: a comparison of three different concentrations of ropivacaine for continuous femoral nerve blockade. Anesth Analg. 2007;105:256–62.CrossRef Brodner G, Buerkle H, Van Aken H, Lambert R, Schweppe-Hartenauer ML, Wempe C, Gogarten W. Postoperative analgesia after knee surgery: a comparison of three different concentrations of ropivacaine for continuous femoral nerve blockade. Anesth Analg. 2007;105:256–62.CrossRef
7.
go back to reference Bauer M, Wang L, Onibonoje OK Parrett C, Sessler DI, Mounir-Soliman L, Zaky S, Krebs V, Buller LT, Donohue MC, Stevens-Lapsley JE, Ilfeld BM. Continuous femoral nerve blocks: decreasing local anesthetic concentration to minimize quadriceps femoris weakness. Anesthesiology. 2012;116:665–72.CrossRef Bauer M, Wang L, Onibonoje OK Parrett C, Sessler DI, Mounir-Soliman L, Zaky S, Krebs V, Buller LT, Donohue MC, Stevens-Lapsley JE, Ilfeld BM. Continuous femoral nerve blocks: decreasing local anesthetic concentration to minimize quadriceps femoris weakness. Anesthesiology. 2012;116:665–72.CrossRef
8.
go back to reference Sia AT, Lim Y, Ocampo CE. A comparison of a basal infusion with automated mandatory boluses in parturient-controlled epidural analgesia during labor. Anesth Analg. 2007;(3):673–8. Sia AT, Lim Y, Ocampo CE. A comparison of a basal infusion with automated mandatory boluses in parturient-controlled epidural analgesia during labor. Anesth Analg. 2007;(3):673–8.
9.
go back to reference Taboada M, Rodriguez J, Bermudez M, Valiño C, Ulloa B, Aneiros F, Gude F, Cortés J, Alvarez J, Atanassoff PG. A “new” automated bolus technique for continuous popliteal block: a prospective, randomized comparison with a continuous infusion technique. Anesth Analg. 2008;107:1433–7.CrossRef Taboada M, Rodriguez J, Bermudez M, Valiño C, Ulloa B, Aneiros F, Gude F, Cortés J, Alvarez J, Atanassoff PG. A “new” automated bolus technique for continuous popliteal block: a prospective, randomized comparison with a continuous infusion technique. Anesth Analg. 2008;107:1433–7.CrossRef
10.
go back to reference Frederickson MJ, Abeysekera A, Price DJ, Wong AC. Patient-initiated mandatory boluses for ambulatory continuous interscalene analgesia: an effective strategy for optimizing analgesia and minimizing side-effects. Br J Anaesth. 2011;106:239–45.CrossRef Frederickson MJ, Abeysekera A, Price DJ, Wong AC. Patient-initiated mandatory boluses for ambulatory continuous interscalene analgesia: an effective strategy for optimizing analgesia and minimizing side-effects. Br J Anaesth. 2011;106:239–45.CrossRef
11.
go back to reference Charous MT, Madison SJ, Suresh PJ, Sandhu NS, Loland VJ, Mariano ER, Donohue MC, Dutton PH, Ferguson EJ, Ilfeld BM. Continuous femoral nerve blocks: varying local anesthetic delivery method (bolus versus basal) to minimize quadriceps motor block while maintaining sensory block. Anesthesiology. 2011;115:774–81.CrossRef Charous MT, Madison SJ, Suresh PJ, Sandhu NS, Loland VJ, Mariano ER, Donohue MC, Dutton PH, Ferguson EJ, Ilfeld BM. Continuous femoral nerve blocks: varying local anesthetic delivery method (bolus versus basal) to minimize quadriceps motor block while maintaining sensory block. Anesthesiology. 2011;115:774–81.CrossRef
12.
go back to reference Michael S, Richmond MN, Birks RJ. A comparison between open-end (single hole) and closed-end (three lateral holes) epidural catheters. Complications and quality of sensory blockade. Anaesthesia. 1989;44:578–80.CrossRef Michael S, Richmond MN, Birks RJ. A comparison between open-end (single hole) and closed-end (three lateral holes) epidural catheters. Complications and quality of sensory blockade. Anaesthesia. 1989;44:578–80.CrossRef
13.
go back to reference Dickson MA, Moores C, McClure JH. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour. Br J Anaesth. 1997;79:297–300.CrossRef Dickson MA, Moores C, McClure JH. Comparison of single, end-holed and multi-orifice extradural catheters when used for continuous infusion of local anaesthetic during labour. Br J Anaesth. 1997;79:297–300.CrossRef
14.
go back to reference D’Angelo R, Foss ML, Livesay CH. A comparison of multiport and uniport epidural catheters in laboring patients. Anesth Analg. 1997;84:1276–9.CrossRef D’Angelo R, Foss ML, Livesay CH. A comparison of multiport and uniport epidural catheters in laboring patients. Anesth Analg. 1997;84:1276–9.CrossRef
15.
go back to reference Fredrickson MJ, Ball CM, Dalgleish AJ. Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade. Reg Anesth Pain Med. 2011;36:470–5.CrossRef Fredrickson MJ, Ball CM, Dalgleish AJ. Catheter orifice configuration influences the effectiveness of continuous peripheral nerve blockade. Reg Anesth Pain Med. 2011;36:470–5.CrossRef
16.
go back to reference Fredrickson MJ. Randomised comparison of an end-hole, triple-hole and novel six-hole catheter for continuous interscalene analgesia. Anaesth Intensive Care. 2014;42:37–42.PubMed Fredrickson MJ. Randomised comparison of an end-hole, triple-hole and novel six-hole catheter for continuous interscalene analgesia. Anaesth Intensive Care. 2014;42:37–42.PubMed
17.
go back to reference Fegley AJ, Lerman J, Wissler R. Epidural multiorifice catheters function as single-orifice catheters: an in vitro study. Anesth Analg. 2008;107:1079–81.CrossRef Fegley AJ, Lerman J, Wissler R. Epidural multiorifice catheters function as single-orifice catheters: an in vitro study. Anesth Analg. 2008;107:1079–81.CrossRef
18.
go back to reference Schulz KF, Altman DG, Moher D, CONSORT Group. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c332.CrossRef Schulz KF, Altman DG, Moher D, CONSORT Group. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c332.CrossRef
19.
go back to reference Bohannon RW. Measuring knee extensor muscle strength. Am J Phys Med Rehabil. 2001;80:13–8.CrossRef Bohannon RW. Measuring knee extensor muscle strength. Am J Phys Med Rehabil. 2001;80:13–8.CrossRef
20.
go back to reference Gandhi K, Lindenmuth DM, Hadzic A, Xu D, Patel VS, Maliakal TJ, Gadsden JC. The effect of stimulating versus conventional perineural catheters on postoperative analgesia following ultrasound-guided femoral nerve localization. J Clin Anesth. 2011;23:626–31.CrossRef Gandhi K, Lindenmuth DM, Hadzic A, Xu D, Patel VS, Maliakal TJ, Gadsden JC. The effect of stimulating versus conventional perineural catheters on postoperative analgesia following ultrasound-guided femoral nerve localization. J Clin Anesth. 2011;23:626–31.CrossRef
21.
go back to reference Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg. 2006;102:904–9.CrossRef Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg. 2006;102:904–9.CrossRef
22.
go back to reference Ueda K, Ueda W, Manabe M. A comparative study of sequential epidural bolus technique and continuous epidural infusion. Anesthesiology. 2005;103:126–9.CrossRef Ueda K, Ueda W, Manabe M. A comparative study of sequential epidural bolus technique and continuous epidural infusion. Anesthesiology. 2005;103:126–9.CrossRef
23.
go back to reference Kaynar AM, Shankar KB. Epidural infusion: continuous or bolus? Anesth Analg. 1999;89:534.PubMed Kaynar AM, Shankar KB. Epidural infusion: continuous or bolus? Anesth Analg. 1999;89:534.PubMed
Metadata
Title
Ultrasound-guided continuous femoral nerve block: a randomized trial on the influence of femoral nerve catheter orifice configuration (six-hole versus end-hole) on post-operative analgesia after total knee arthroplasty
Authors
Alessandra Novello-Siegenthaler
Mehdi Hamdani
Irène Iselin-Chaves
Roxane Fournier
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2018
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-018-0648-8

Other articles of this Issue 1/2018

BMC Anesthesiology 1/2018 Go to the issue