Published in: BMC Anesthesiology 1/2018

Open Access 01-12-2018 | Research article

Use, applicability and reliability of depth of hypnosis monitors in children - a survey among members of the European Society for Paediatric Anaesthesiology

Authors: Yuen Man Cheung, Gail Scoones, Robert Jan Stolker, Frank Weber

Published in: BMC Anesthesiology | Issue 1/2018

Login to get access

Abstract

Background

To assess the thoughts of practicing anaesthesiologists about the use of depth of hypnosis monitors in children.

Methods

Members of the European Society for Paediatric Anaesthesiology were invited to participate in an online survey about their thoughts regarding the use, applicability and reliability of hypnosis monitoring in children.

Results

The survey achieved a response rate of 30% (N = 168). A total of 138 completed surveys were included for further analysis. Sixty-eight respondents used hypnosis monitoring in children (Users) and 70 did not (Non-users). Sixty-five percent of the Users reported prevention of intra-operative awareness as their main reason to apply hypnosis monitoring. Among the Non-users, the most frequently given reason (43%) not to use hypnosis monitoring in children was the perceived lack or reliability of the devices in children. Hypnosis monitoring is used with a higher frequency during propofol anaesthesia than during inhalation anaesthesia. Hypnosis monitoring is furthermore used more frequently in children > 4 years than in younger children. An ideal hypnosis monitor should be reliable for all age groups and any (combination of) anaesthetic drug. We found no agreement in the interpretation of monitor index values and subsequent anaesthetic interventions following from it.

Conclusions

Prevention of intraoperative awareness appears to be the most important reason to use hypnosis monitoring in children. The perceived lack of reliability of hypnosis monitoring in children is the most important reasons not to use it. No consensus currently exists on how to adjust anaesthesia according to hypnosis monitor index values in children.
Appendix
Available only for authorised users
Literature
1.
go back to reference Marchant N, Sanders R, Sleigh J, Vanhaudenhuyse A, Bruno MA, Brichant JF, et al. How electroencephalography serves the anesthesiologist. Clin EEG Neurosci. 2014;45:22–32.CrossRefPubMed Marchant N, Sanders R, Sleigh J, Vanhaudenhuyse A, Bruno MA, Brichant JF, et al. How electroencephalography serves the anesthesiologist. Clin EEG Neurosci. 2014;45:22–32.CrossRefPubMed
2.
go back to reference Escallier KE, Nadelson MR, Zhou D, Avidan MS. Monitoring the brain: processed electroencephalogram and peri-operative outcomes. Anaesthesia. 2014;69:899–910.CrossRefPubMed Escallier KE, Nadelson MR, Zhou D, Avidan MS. Monitoring the brain: processed electroencephalogram and peri-operative outcomes. Anaesthesia. 2014;69:899–910.CrossRefPubMed
3.
go back to reference Davidson AJ. Monitoring the anaesthetic depth in children - an update. Curr Opin Anaesthesiol. 2007;20:236–43.CrossRefPubMed Davidson AJ. Monitoring the anaesthetic depth in children - an update. Curr Opin Anaesthesiol. 2007;20:236–43.CrossRefPubMed
5.
go back to reference Mantel N. Chi-Square tests with one degree of freedom; extensions of the mantel- Haenszel procedure. J Am Stat Assoc. 1963;58:690–700. Mantel N. Chi-Square tests with one degree of freedom; extensions of the mantel- Haenszel procedure. J Am Stat Assoc. 1963;58:690–700.
6.
go back to reference Davidson AJ, Smith KR, Blusse van oud-Alblas HJ, Lopez U, Malviya S, Bannister CF, et al. Awareness in children: a secondary analysis of five cohort studies. Anaesthesia. 2011;66:446–54.CrossRefPubMed Davidson AJ, Smith KR, Blusse van oud-Alblas HJ, Lopez U, Malviya S, Bannister CF, et al. Awareness in children: a secondary analysis of five cohort studies. Anaesthesia. 2011;66:446–54.CrossRefPubMed
7.
go back to reference Myles PS, Leslie K, McNeil J, Forbes A, Chan MT. Bispectral index monitoring to prevent awareness during anaesthesia: the B-aware randomised controlled trial. Lancet. 2004;363:1757–63.CrossRefPubMed Myles PS, Leslie K, McNeil J, Forbes A, Chan MT. Bispectral index monitoring to prevent awareness during anaesthesia: the B-aware randomised controlled trial. Lancet. 2004;363:1757–63.CrossRefPubMed
8.
go back to reference Avidan MS, Zhang L, Burnside BA, Finkel KJ, Searleman AC, Selvidge JA, et al. Anesthesia awareness and the bispectral index. N Engl J Med. 2008;358:1097–108.CrossRefPubMed Avidan MS, Zhang L, Burnside BA, Finkel KJ, Searleman AC, Selvidge JA, et al. Anesthesia awareness and the bispectral index. N Engl J Med. 2008;358:1097–108.CrossRefPubMed
9.
go back to reference Song D, Joshi GP, White PF. Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology. 1997;87:842–8.CrossRefPubMed Song D, Joshi GP, White PF. Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology. 1997;87:842–8.CrossRefPubMed
10.
go back to reference Weber F, Pohl F, Hollnberger H, Taeger K. Impact of the Narcotrend index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children: a clinical utility study. Eur J Anaesthesiol. 2005;22:741–7.CrossRefPubMed Weber F, Pohl F, Hollnberger H, Taeger K. Impact of the Narcotrend index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children: a clinical utility study. Eur J Anaesthesiol. 2005;22:741–7.CrossRefPubMed
11.
go back to reference Yli-Hankala A, Vakkuri A, Annila P, Korttila K. EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery. Acta Anaesthesiol Scand. 1999;43:545–9.CrossRefPubMed Yli-Hankala A, Vakkuri A, Annila P, Korttila K. EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery. Acta Anaesthesiol Scand. 1999;43:545–9.CrossRefPubMed
12.
go back to reference Weber F, Seidl M, Bein T. Impact of the AEP-monitor/2-derived composite auditory-evoked potential index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children. Acta Anaesthesiol Scand. 2005;49:277–83.CrossRefPubMed Weber F, Seidl M, Bein T. Impact of the AEP-monitor/2-derived composite auditory-evoked potential index on propofol consumption and emergence times during total intravenous anaesthesia with propofol and remifentanil in children. Acta Anaesthesiol Scand. 2005;49:277–83.CrossRefPubMed
13.
go back to reference Hansen TG, Engelhardt T, Weiss M. The relevance of anesthetic drug-induced neurotoxicity. JAMA Pediatr. 2017;171:e163481.CrossRefPubMed Hansen TG, Engelhardt T, Weiss M. The relevance of anesthetic drug-induced neurotoxicity. JAMA Pediatr. 2017;171:e163481.CrossRefPubMed
14.
go back to reference Rappaport B, Mellon RD, Simone A, Woodcock J. Defining safe use of anesthesia in children. N Engl J Med. 2011;364:1387–90.CrossRefPubMed Rappaport B, Mellon RD, Simone A, Woodcock J. Defining safe use of anesthesia in children. N Engl J Med. 2011;364:1387–90.CrossRefPubMed
15.
go back to reference Kalkman CJ, Peelen L, Moons KG, Veenhuizen M, Bruens M, Sinnema G, et al. Behavior and development in children and age at the time of first anesthetic exposure. Anesthesiology. 2009;110:805–12.CrossRefPubMed Kalkman CJ, Peelen L, Moons KG, Veenhuizen M, Bruens M, Sinnema G, et al. Behavior and development in children and age at the time of first anesthetic exposure. Anesthesiology. 2009;110:805–12.CrossRefPubMed
16.
go back to reference Cornelissen L, Kim SE, Purdon PL, Brown EN, Berde CB. Age-dependent electroencephalogram (EEG) patterns during sevoflurane general anesthesia in infants. elife. 2015;4:e06513.CrossRefPubMedPubMedCentral Cornelissen L, Kim SE, Purdon PL, Brown EN, Berde CB. Age-dependent electroencephalogram (EEG) patterns during sevoflurane general anesthesia in infants. elife. 2015;4:e06513.CrossRefPubMedPubMedCentral
18.
go back to reference Davidson AJ, Wong A, Knottenbelt G, Sheppard S, Donath S, Frawley G. MAC-awake of sevoflurane in children. Paediatr Anaesth. 2008;18:702–7.CrossRefPubMed Davidson AJ, Wong A, Knottenbelt G, Sheppard S, Donath S, Frawley G. MAC-awake of sevoflurane in children. Paediatr Anaesth. 2008;18:702–7.CrossRefPubMed
19.
go back to reference Schneider G, Jordan D, Schwarz G, Bischoff P, Kalkman CJ, Kuppe H, et al. Monitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures. Anesthesiology. 2014;120:819–28.CrossRefPubMed Schneider G, Jordan D, Schwarz G, Bischoff P, Kalkman CJ, Kuppe H, et al. Monitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures. Anesthesiology. 2014;120:819–28.CrossRefPubMed
20.
go back to reference Smith WD, Dutton RC, Smith NT. Measuring the performance of anesthetic depth indicators. Anesthesiology. 1996;84:38–51.CrossRefPubMed Smith WD, Dutton RC, Smith NT. Measuring the performance of anesthetic depth indicators. Anesthesiology. 1996;84:38–51.CrossRefPubMed
21.
go back to reference Purdon PL, Sampson A, Pavone KJ, Brown EN. Clinical electroencephalography for anesthesiologists: part I: background and basic signatures. Anesthesiology. 2015;123:937–60.CrossRefPubMedPubMedCentral Purdon PL, Sampson A, Pavone KJ, Brown EN. Clinical electroencephalography for anesthesiologists: part I: background and basic signatures. Anesthesiology. 2015;123:937–60.CrossRefPubMedPubMedCentral
22.
go back to reference Akeju O, Pavone KJ, Thum JA, Firth PG, Westover MB, Puglia M, et al. Age-dependency of sevoflurane-induced electroencephalogram dynamics in children. Br J Anaesth. 2015;115(Suppl 1):i66–76.CrossRefPubMedPubMedCentral Akeju O, Pavone KJ, Thum JA, Firth PG, Westover MB, Puglia M, et al. Age-dependency of sevoflurane-induced electroencephalogram dynamics in children. Br J Anaesth. 2015;115(Suppl 1):i66–76.CrossRefPubMedPubMedCentral
Metadata
Title
Use, applicability and reliability of depth of hypnosis monitors in children - a survey among members of the European Society for Paediatric Anaesthesiology
Authors
Yuen Man Cheung
Gail Scoones
Robert Jan Stolker
Frank Weber
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2018
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-018-0503-y

Other articles of this Issue 1/2018

BMC Anesthesiology 1/2018 Go to the issue