Skip to main content
Top
Published in: BMC Anesthesiology 1/2015

Open Access 01-12-2015 | Case report

Intraoperative echocardiographic delineation of the high take-off coronary ostia during an extensive surgical repair of the bicuspid aortic valve and dilated sinotubular junction: a case report

Authors: Hyun Ju Jung, Won-Kyoung Kwon, Sung Jun Lee, Nazri Mohamed, Bo-Mi Shin, Jinyoung Lee, Tae-Yop Kim

Published in: BMC Anesthesiology | Issue 1/2015

Login to get access

Abstract

Background

This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

Case presentation

In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

Conclusion

In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.
Literature
1.
go back to reference Song MG, Yang HS, Choi JB, Shin JK, Chee HK, Kim JS. Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation. Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation: early and midterm results. Ann Thorac Surg. 2014;97:1235–41.CrossRefPubMed Song MG, Yang HS, Choi JB, Shin JK, Chee HK, Kim JS. Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation. Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation: early and midterm results. Ann Thorac Surg. 2014;97:1235–41.CrossRefPubMed
2.
go back to reference Song MG, Yang HS, Choi JB, Shin JK, Chee HK, Kim JS. Aortic valve reconstruction with use of pericardial leaflets in adults with bicuspid aortic valve disease: early and midterm outcomes. Tex Heart Inst J. 2014;41:585–91.CrossRefPubMedPubMedCentral Song MG, Yang HS, Choi JB, Shin JK, Chee HK, Kim JS. Aortic valve reconstruction with use of pericardial leaflets in adults with bicuspid aortic valve disease: early and midterm outcomes. Tex Heart Inst J. 2014;41:585–91.CrossRefPubMedPubMedCentral
3.
go back to reference Kim J, Yu GY, Seok J, Oh CS, Kim SH, Kim TY. Imaging of coronary artery fistulae by using intraoperative three-dimensional transesophageal echocardiography. Anesth Analg. 2014;118:721–4.CrossRefPubMed Kim J, Yu GY, Seok J, Oh CS, Kim SH, Kim TY. Imaging of coronary artery fistulae by using intraoperative three-dimensional transesophageal echocardiography. Anesth Analg. 2014;118:721–4.CrossRefPubMed
4.
go back to reference Prakken NH, Cramer MJ, Olimulder MA, Agostoni P, Mali WP, Velthuis BK. Screening for proximal coronary artery anomalies with 3-dimensional MR coronary angiography. Int J Cardiovasc Imaging. 2010;26:701–10.CrossRefPubMedPubMedCentral Prakken NH, Cramer MJ, Olimulder MA, Agostoni P, Mali WP, Velthuis BK. Screening for proximal coronary artery anomalies with 3-dimensional MR coronary angiography. Int J Cardiovasc Imaging. 2010;26:701–10.CrossRefPubMedPubMedCentral
5.
go back to reference le Polain de Waroux JB, Pouleur AC, Pasquet A, Gerber BL, Noirhomme P, et al. Mechanisms of recurrent aortic regurgitation after aortic valve repair: Predictive value of intraoperative transesophageal echocardiography. JACC Cardiovasc Imaging. 2009;2:931–9.CrossRef le Polain de Waroux JB, Pouleur AC, Pasquet A, Gerber BL, Noirhomme P, et al. Mechanisms of recurrent aortic regurgitation after aortic valve repair: Predictive value of intraoperative transesophageal echocardiography. JACC Cardiovasc Imaging. 2009;2:931–9.CrossRef
6.
go back to reference Augoustides JG, Szeto WY, Bavaria JE. Advances in aortic valve repair: Focus on functional approach, clinical outcomes, and central role of echocardiography. J Cardiothorac Vasc Anesth. 2010;24:1016–20.CrossRefPubMed Augoustides JG, Szeto WY, Bavaria JE. Advances in aortic valve repair: Focus on functional approach, clinical outcomes, and central role of echocardiography. J Cardiothorac Vasc Anesth. 2010;24:1016–20.CrossRefPubMed
7.
go back to reference Tian D, Rahnavardi M, Yan TD. Aortic valve sparing operations in aortic root aneurysms: remodeling or reimplantation? Ann Cardiothorac Surg. 2013;2:44–52.PubMedPubMedCentral Tian D, Rahnavardi M, Yan TD. Aortic valve sparing operations in aortic root aneurysms: remodeling or reimplantation? Ann Cardiothorac Surg. 2013;2:44–52.PubMedPubMedCentral
Metadata
Title
Intraoperative echocardiographic delineation of the high take-off coronary ostia during an extensive surgical repair of the bicuspid aortic valve and dilated sinotubular junction: a case report
Authors
Hyun Ju Jung
Won-Kyoung Kwon
Sung Jun Lee
Nazri Mohamed
Bo-Mi Shin
Jinyoung Lee
Tae-Yop Kim
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2015
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-016-0250-x

Other articles of this Issue 1/2015

BMC Anesthesiology 1/2015 Go to the issue