Published in: Critical Care 1/2009

Open Access 01-02-2009 | Research

Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomised controlled trial

Authors: Corinne Taniguchi, Raquel C Eid, Cilene Saghabi, Rogério Souza, Eliezer Silva, Elias Knobel, Ângela T Paes, Carmen S Barbas

Published in: Critical Care | Issue 1/2009

Login to get access

Abstract

Introduction

Reduction of automatic pressure support based on a target respiratory frequency or mandatory rate ventilation (MRV) is available in the Taema-Horus ventilator for the weaning process in the intensive care unit (ICU) setting. We hypothesised that MRV is as effective as manual weaning in post-operative ICU patients.

Methods

There were 106 patients selected in the post-operative period in a prospective, randomised, controlled protocol. When the patients arrived at the ICU after surgery, they were randomly assigned to either: traditional weaning, consisting of the manual reduction of pressure support every 30 minutes, keeping the respiratory rate/tidal volume (RR/TV) below 80 L until 5 to 7 cmH2O of pressure support ventilation (PSV); or automatic weaning, referring to MRV set with a respiratory frequency target of 15 breaths per minute (the ventilator automatically decreased the PSV level by 1 cmH2O every four respiratory cycles, if the patient's RR was less than 15 per minute). The primary endpoint of the study was the duration of the weaning process. Secondary endpoints were levels of pressure support, RR, TV (mL), RR/TV, positive end expiratory pressure levels, FiO2 and SpO2 required during the weaning process, the need for reintubation and the need for non-invasive ventilation in the 48 hours after extubation.

Results

In the intention to treat analysis there were no statistically significant differences between the 53 patients selected for each group regarding gender (p = 0.541), age (p = 0.585) and type of surgery (p = 0.172). Nineteen patients presented complications during the trial (4 in the PSV manual group and 15 in the MRV automatic group, p < 0.05). Nine patients in the automatic group did not adapt to the MRV mode. The mean ± sd (standard deviation) duration of the weaning process was 221 ± 192 for the manual group, and 271 ± 369 minutes for the automatic group (p = 0.375). PSV levels were significantly higher in MRV compared with that of the PSV manual reduction (p < 0.05). Reintubation was not required in either group. Non-invasive ventilation was necessary for two patients, in the manual group after cardiac surgery (p = 0.51).

Conclusions

The duration of the automatic reduction of pressure support was similar to the manual one in the post-operative period in the ICU, but presented more complications, especially no adaptation to the MRV algorithm.

Trial Registration

Trial registration number: ISRCTN37456640
Appendix
Available only for authorised users
Literature
1.
go back to reference Eskandar N, Apostolakos MJ: Weaning from mechanical ventilation. Crit Care Clin 2007, 23: 263-274. 10.1016/j.ccc.2006.12.002CrossRefPubMed Eskandar N, Apostolakos MJ: Weaning from mechanical ventilation. Crit Care Clin 2007, 23: 263-274. 10.1016/j.ccc.2006.12.002CrossRefPubMed
2.
go back to reference Esteban A, Frutos F, Tobin MJ, Alia I, Solsona JF, Valverdu V, Fernandez R, De la Cal MA, Benito S, Tomas R, Carriedo D, Macias S, Blanco J: A comparison of four methods of weaning patients from mechanical ventilation. N Engl J Med 1995, 332: 345-350. 10.1056/NEJM199502093320601CrossRefPubMed Esteban A, Frutos F, Tobin MJ, Alia I, Solsona JF, Valverdu V, Fernandez R, De la Cal MA, Benito S, Tomas R, Carriedo D, Macias S, Blanco J: A comparison of four methods of weaning patients from mechanical ventilation. N Engl J Med 1995, 332: 345-350. 10.1056/NEJM199502093320601CrossRefPubMed
3.
go back to reference Esteban A, Alia I, Gordo F, Gordo F, Fernandez R, Solsona JF, Vallverdú I, Macias S, Allegue JM, Blanco J, CArriedo D, Léon M, De la Cal MA, Taboada F, Velasco JG, Palazón E, Carrizosa F, Tomás R, Suarez J, Goldwasser R: Extubation outcome after spontaneous breathing trial with T-peace or pressure support ventilation. Am J Respir Crit Care Med 1997, 156: 459-465.CrossRefPubMed Esteban A, Alia I, Gordo F, Gordo F, Fernandez R, Solsona JF, Vallverdú I, Macias S, Allegue JM, Blanco J, CArriedo D, Léon M, De la Cal MA, Taboada F, Velasco JG, Palazón E, Carrizosa F, Tomás R, Suarez J, Goldwasser R: Extubation outcome after spontaneous breathing trial with T-peace or pressure support ventilation. Am J Respir Crit Care Med 1997, 156: 459-465.CrossRefPubMed
4.
go back to reference Brochard L, Rauss A, Benito S, Conti G, Mancebo J, Rekik N, Gasparetto A, Lemaire F: Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respr Crit Care Med 1994, 150: 896-903.CrossRef Brochard L, Rauss A, Benito S, Conti G, Mancebo J, Rekik N, Gasparetto A, Lemaire F: Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respr Crit Care Med 1994, 150: 896-903.CrossRef
5.
go back to reference Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF: Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med 1996, 335: 1864-1869. 10.1056/NEJM199612193352502CrossRefPubMed Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF: Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med 1996, 335: 1864-1869. 10.1056/NEJM199612193352502CrossRefPubMed
6.
go back to reference Smyrnios NA, Connolly A, Wilson MM, Curley FJ, French CT, Heard SO, Irwin RS: Effects of a multifaceted, multidisciplinary, hospital-wide quality improvement program on weaning from mechanical ventilation. Crit Care Med 2002, 30: 1224-1230. 10.1097/00003246-200206000-00009CrossRefPubMed Smyrnios NA, Connolly A, Wilson MM, Curley FJ, French CT, Heard SO, Irwin RS: Effects of a multifaceted, multidisciplinary, hospital-wide quality improvement program on weaning from mechanical ventilation. Crit Care Med 2002, 30: 1224-1230. 10.1097/00003246-200206000-00009CrossRefPubMed
7.
go back to reference Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia Am J Respir Crit Care Med 2005, 171: 388-416. 10.1164/rccm.200405-644ST Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia Am J Respir Crit Care Med 2005, 171: 388-416. 10.1164/rccm.200405-644ST
8.
go back to reference Torres A, Carlet J: Ventilator-associated pneumonia. Eur Respir J 2001, 17: 1034-1045. 10.1183/09031936.01.17510340CrossRefPubMed Torres A, Carlet J: Ventilator-associated pneumonia. Eur Respir J 2001, 17: 1034-1045. 10.1183/09031936.01.17510340CrossRefPubMed
9.
go back to reference Epstein SK, Ciubotaru RL, Wong JB: Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997, 112: 186-192. 10.1378/chest.112.1.186CrossRefPubMed Epstein SK, Ciubotaru RL, Wong JB: Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997, 112: 186-192. 10.1378/chest.112.1.186CrossRefPubMed
10.
go back to reference Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L: A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006, 174: 894-900. 10.1164/rccm.200511-1780OCCrossRefPubMed Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L: A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med 2006, 174: 894-900. 10.1164/rccm.200511-1780OCCrossRefPubMed
11.
go back to reference Kollef MH, Shapiro SD, Silver P, St John RE, Prentice D, Sauer S, Ahrens TS, Shannon W, Baker-Clinkscale D: A randomized controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation. Crit Care Med 1997, 25: 567-574. 10.1097/00003246-199704000-00004CrossRefPubMed Kollef MH, Shapiro SD, Silver P, St John RE, Prentice D, Sauer S, Ahrens TS, Shannon W, Baker-Clinkscale D: A randomized controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation. Crit Care Med 1997, 25: 567-574. 10.1097/00003246-199704000-00004CrossRefPubMed
12.
go back to reference Ely EW, Meade MO, Haponik EF, Kollef MH, Cook DJ, Guyatt GH, Stoller JK: Mechanical ventilator weaning protocols driven by nonphysician health-care professionals: evidence-based clinical practice guidelines. Chest 2001, 120: 454S-463S. 10.1378/chest.120.6_suppl.454SCrossRefPubMed Ely EW, Meade MO, Haponik EF, Kollef MH, Cook DJ, Guyatt GH, Stoller JK: Mechanical ventilator weaning protocols driven by nonphysician health-care professionals: evidence-based clinical practice guidelines. Chest 2001, 120: 454S-463S. 10.1378/chest.120.6_suppl.454SCrossRefPubMed
13.
go back to reference Barbas CSV, Amato MBP, Carvalho CRR: Monitorização no desmame da ventilação mecânica. Em Associação médica brasileira de intensivistas (AMIB), Ventilação mecânica – Volume II – Avançado 1998, 5: 363-376. Barbas CSV, Amato MBP, Carvalho CRR: Monitorização no desmame da ventilação mecânica. Em Associação médica brasileira de intensivistas (AMIB), Ventilação mecânica – Volume II – Avançado 1998, 5: 363-376.
14.
go back to reference Hess DR: Liberation from mechanical ventilation: weaning the patient or weaning old-fashioned ideas? Crit Care Med 2002, 30: 2154-2155. 10.1097/00003246-200209000-00040CrossRefPubMed Hess DR: Liberation from mechanical ventilation: weaning the patient or weaning old-fashioned ideas? Crit Care Med 2002, 30: 2154-2155. 10.1097/00003246-200209000-00040CrossRefPubMed
15.
go back to reference Laghi F, Karamchandani K, Tobin MJ: Influence of ventilator settings in determining respiratory frequency during mechanical ventilation. Am J Respir Crit Care Med 1999, 160: 1766-1770.CrossRefPubMed Laghi F, Karamchandani K, Tobin MJ: Influence of ventilator settings in determining respiratory frequency during mechanical ventilation. Am J Respir Crit Care Med 1999, 160: 1766-1770.CrossRefPubMed
16.
go back to reference Tanios MA, Nevins ML, Hendra KP: The use of weaning parameters prolongs mechanical ventilation time. Chest 2001, 120: 190S-191S. Tanios MA, Nevins ML, Hendra KP: The use of weaning parameters prolongs mechanical ventilation time. Chest 2001, 120: 190S-191S.
17.
go back to reference Tobert DG, Simon PM, Stroetz RW, Hubmayr RD: The determinants of respiratory rate during mechanical ventilation. Am J Respir Crit Care Med 1997, 155: 485-492.CrossRefPubMed Tobert DG, Simon PM, Stroetz RW, Hubmayr RD: The determinants of respiratory rate during mechanical ventilation. Am J Respir Crit Care Med 1997, 155: 485-492.CrossRefPubMed
18.
go back to reference Tobin MJ, Perez W, Guenther SM, Semmes BJ, Mador MJ, Allen SJ, Lodato RF, Dantzker DR: The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis 1986, 134: 1111-1118.PubMed Tobin MJ, Perez W, Guenther SM, Semmes BJ, Mador MJ, Allen SJ, Lodato RF, Dantzker DR: The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis 1986, 134: 1111-1118.PubMed
19.
go back to reference Bachmann PV, Annat G, Delafosse B: Mandatory rate ventilation during the period of weaning. Anesthesiology 1991, 75: A253. 10.1097/00000542-199109001-00253CrossRef Bachmann PV, Annat G, Delafosse B: Mandatory rate ventilation during the period of weaning. Anesthesiology 1991, 75: A253. 10.1097/00000542-199109001-00253CrossRef
20.
go back to reference Langevin B, Robert D: Mandatory frequency pressure support ventilation during the weaning process. Am Rev Resp Crit Care Med 1994, 149: A637. Langevin B, Robert D: Mandatory frequency pressure support ventilation during the weaning process. Am Rev Resp Crit Care Med 1994, 149: A637.
21.
go back to reference Chopin C, Chambrin MC: Les bucles d'asservissement en assistance ventilatoire. In Reanimation Ventilation artificielle, Principes et applications. Edited by: Brochard L, Mancebo J. Paris: Arnnet; 1994:199-213. Chopin C, Chambrin MC: Les bucles d'asservissement en assistance ventilatoire. In Reanimation Ventilation artificielle, Principes et applications. Edited by: Brochard L, Mancebo J. Paris: Arnnet; 1994:199-213.
22.
go back to reference Burns KEA, Lellouche F, Lessard MR: Automating the weaning process with advanced closed-loop system. Intensive Care Med 2008, 34: 1757-1765. 10.1007/s00134-008-1154-0CrossRefPubMed Burns KEA, Lellouche F, Lessard MR: Automating the weaning process with advanced closed-loop system. Intensive Care Med 2008, 34: 1757-1765. 10.1007/s00134-008-1154-0CrossRefPubMed
23.
go back to reference Branson RD: Techniques for automated feedback control of mechanical ventilation. Semin Respir Crit Care Med 2000, 21: 203-209. 10.1055/s-2000-9847CrossRefPubMed Branson RD: Techniques for automated feedback control of mechanical ventilation. Semin Respir Crit Care Med 2000, 21: 203-209. 10.1055/s-2000-9847CrossRefPubMed
24.
go back to reference Rose L, Presneill JJ, Johnston L, Cade JF: A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCaretrade mark/PS. Intensive Care Med 2008, 34: 1788-1795. 10.1007/s00134-008-1179-4CrossRefPubMed Rose L, Presneill JJ, Johnston L, Cade JF: A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCaretrade mark/PS. Intensive Care Med 2008, 34: 1788-1795. 10.1007/s00134-008-1179-4CrossRefPubMed
25.
go back to reference Dojat M, Harf A, Touchard D, Lemaire F, Brochard L: Clinical evaluation of a computer-controlled pressure support mode. Am J Respir Crit Care Med 2000, 161: 1161-1166.PubMedCentralCrossRefPubMed Dojat M, Harf A, Touchard D, Lemaire F, Brochard L: Clinical evaluation of a computer-controlled pressure support mode. Am J Respir Crit Care Med 2000, 161: 1161-1166.PubMedCentralCrossRefPubMed
26.
go back to reference Jouvet P, Farges C, Hatzakis G, Monir A, Lesage F, Dupic L, Brochard L, Hubert P: Weaning children from mechanical ventilation with a computer-driven system (closed-loop protocol): A pilot study. Pediatr Crit Care Med 2007, 8: 425-432. 10.1097/01.PCC.0000269381.43529.92CrossRefPubMed Jouvet P, Farges C, Hatzakis G, Monir A, Lesage F, Dupic L, Brochard L, Hubert P: Weaning children from mechanical ventilation with a computer-driven system (closed-loop protocol): A pilot study. Pediatr Crit Care Med 2007, 8: 425-432. 10.1097/01.PCC.0000269381.43529.92CrossRefPubMed
27.
go back to reference Stroetz RW, Hubmayr RD: Tidal volume maintenance during weaning with pressure support. Am J Respir Crit Care Med 1995, 152: 1034-1040.CrossRefPubMed Stroetz RW, Hubmayr RD: Tidal volume maintenance during weaning with pressure support. Am J Respir Crit Care Med 1995, 152: 1034-1040.CrossRefPubMed
28.
go back to reference Wysocki M, Brunner JX: Closed-loop ventilation: an emerging standard of care? Crit Care Clin 2007, 23: 223-40. Review. 10.1016/j.ccc.2006.12.011CrossRefPubMed Wysocki M, Brunner JX: Closed-loop ventilation: an emerging standard of care? Crit Care Clin 2007, 23: 223-40. Review. 10.1016/j.ccc.2006.12.011CrossRefPubMed
Metadata
Title
Automatic versus manual pressure support reduction in the weaning of post-operative patients: a randomised controlled trial
Authors
Corinne Taniguchi
Raquel C Eid
Cilene Saghabi
Rogério Souza
Eliezer Silva
Elias Knobel
Ângela T Paes
Carmen S Barbas
Publication date
01-02-2009
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2009
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc7695

Other articles of this Issue 1/2009

Critical Care 1/2009 Go to the issue