Skip to main content
Top
Published in: Critical Care 5/2008

01-10-2008 | Commentary

Frontal EEG for intensive care unit sedation: treating numbers or patients?

Author: Peter V Sackey

Published in: Critical Care | Issue 5/2008

Login to get access

Abstract

In this issue of Critical Care, Dr Haenggi and co-workers present a study evaluating bispectral index (BIS), state entropy (SE) and response entropy in 44 patients sedated in the intensive care unit (ICU). As in recent studies attempting to correlate frontal electroencephalogram (EEG) measurements with clinical evaluations of sedative efficacy, there is considerable overlap in numerical EEG values and different clinical levels of sedation. This precludes the use of these monitors for monitoring or titrating sedation in the critically ill. Despite many attempts, no study has yet presented data showing improved outcome with the use of EEG monitors in ICU sedation. Meanwhile, clinical sedation protocols have emerged, improving important endpoints in critically ill patients needing sedation. A major underlying problem in applying EEG monitors in the ICU is that they have been developed for measuring anesthetic depth and the related risk of recall, rather than the acknowledged endpoints of sedation, namely reduction of anxiety and discomfort. Until an 'objective' monitor is developed to measure the degree of such symptoms, physicians should continue treating patients and not numbers.
Literature
1.
go back to reference Haenggi M, Ypparila-Wolters H, Bieri C, Steiner C, Takala J, Korhonen I, Jakob SM: Entropy and bispectral index for the assessment of sedation, analgesia and the effects of unpleasant stimuli in critically ill patients: an observational study. Critical Care 2008, 12: R119. 10.1186/cc7015PubMedCentralCrossRefPubMed Haenggi M, Ypparila-Wolters H, Bieri C, Steiner C, Takala J, Korhonen I, Jakob SM: Entropy and bispectral index for the assessment of sedation, analgesia and the effects of unpleasant stimuli in critically ill patients: an observational study. Critical Care 2008, 12: R119. 10.1186/cc7015PubMedCentralCrossRefPubMed
2.
go back to reference Sackey PV, Radell PJ, Granath F, Martling CR: Bispectral Index™ as a predictor of sedation depth during isoflurane or midazolam sedation. Anaesth Intensive Care 2007, 35: 348-356.PubMed Sackey PV, Radell PJ, Granath F, Martling CR: Bispectral Index™ as a predictor of sedation depth during isoflurane or midazolam sedation. Anaesth Intensive Care 2007, 35: 348-356.PubMed
3.
go back to reference Nasraway SA Jr, Wu EC, Kelleher RM, Yasuda CM, Donelly AM: How reliable is the Bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study. Crit Care Med 2002, 30: 1483-1487. 10.1097/00003246-200207000-00014CrossRef Nasraway SA Jr, Wu EC, Kelleher RM, Yasuda CM, Donelly AM: How reliable is the Bispectral index in critically ill patients? A prospective, comparative, single-blinded observer study. Crit Care Med 2002, 30: 1483-1487. 10.1097/00003246-200207000-00014CrossRef
4.
go back to reference Walsh TS, Ramsay P, Lapinlampi TP, Särkelä MO, Viertiö-Oja HE, Meriläinen PT: An assessment of the validity of spectral entropy as a measure of sedation state in mechanically ventilated critically ill patients. Intensive Care Med 2008, 34: 308-315. 10.1007/s00134-007-0858-xCrossRefPubMed Walsh TS, Ramsay P, Lapinlampi TP, Särkelä MO, Viertiö-Oja HE, Meriläinen PT: An assessment of the validity of spectral entropy as a measure of sedation state in mechanically ventilated critically ill patients. Intensive Care Med 2008, 34: 308-315. 10.1007/s00134-007-0858-xCrossRefPubMed
5.
go back to reference LeBlanc JM, Dasta JF, Kane-Gill SL: Role of the Bispectral Index in sedation monitoring in the ICU. Ann Pharmacother 2006, 40: 490-500. 10.1345/aph.1E491CrossRefPubMed LeBlanc JM, Dasta JF, Kane-Gill SL: Role of the Bispectral Index in sedation monitoring in the ICU. Ann Pharmacother 2006, 40: 490-500. 10.1345/aph.1E491CrossRefPubMed
6.
go back to reference Brook AD, Ahrens TS, Schaiff R, Prentice D, Sherman G, Shannon W, Kollef MH: Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation. Crit Care Med 1999, 27: 2609-2615. 10.1097/00003246-199912000-00001CrossRefPubMed Brook AD, Ahrens TS, Schaiff R, Prentice D, Sherman G, Shannon W, Kollef MH: Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation. Crit Care Med 1999, 27: 2609-2615. 10.1097/00003246-199912000-00001CrossRefPubMed
7.
go back to reference Kress JP, Pohlman AS, O'Connor MF, Hall JB: Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 2000, 342: 1471-1477. 10.1056/NEJM200005183422002CrossRefPubMed Kress JP, Pohlman AS, O'Connor MF, Hall JB: Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 2000, 342: 1471-1477. 10.1056/NEJM200005183422002CrossRefPubMed
8.
go back to reference Girard TD, Kress JP, Fuchs BD, Thomason JW, Schweickert WD, Pun BT, Taichman DB, Dunn JG, Pohlman AS, Kinniry PA, Jackson JC, Canonico AE, Light RW, Shintani AK, Thompson JL, Gordon SM, Hall JB, Dittus RS, Bernard GR, Ely EW: Efficacy and safety of a paired sedation and ventilator weaning protocol for mechanically ventilated patients in intensive care (Awakening and Breathing Controlled trial): a randomised controlled trial. Lancet 2008, 371: 126-134. 10.1016/S0140-6736(08)60105-1CrossRefPubMed Girard TD, Kress JP, Fuchs BD, Thomason JW, Schweickert WD, Pun BT, Taichman DB, Dunn JG, Pohlman AS, Kinniry PA, Jackson JC, Canonico AE, Light RW, Shintani AK, Thompson JL, Gordon SM, Hall JB, Dittus RS, Bernard GR, Ely EW: Efficacy and safety of a paired sedation and ventilator weaning protocol for mechanically ventilated patients in intensive care (Awakening and Breathing Controlled trial): a randomised controlled trial. Lancet 2008, 371: 126-134. 10.1016/S0140-6736(08)60105-1CrossRefPubMed
9.
go back to reference Schweikert WD, Gehlback BK, Pohlman AS, Hall JB, Kress JP: Daily interruption of sedative infusions and complications of critical illness in mechanically ventilated patients. Crit Care Med 2004, 32: 1272-1276. 10.1097/01.CCM.0000127263.54807.79CrossRef Schweikert WD, Gehlback BK, Pohlman AS, Hall JB, Kress JP: Daily interruption of sedative infusions and complications of critical illness in mechanically ventilated patients. Crit Care Med 2004, 32: 1272-1276. 10.1097/01.CCM.0000127263.54807.79CrossRef
10.
go back to reference Sackey PV, Carlswärd C, Martling C-R, Sundin Ö, Radell PJ: Short- and long-term follow-up of ICU patients after sedation with isoflurane and midazolam – a pilot study. Crit Care Med 2008, 36: 801-806.CrossRefPubMed Sackey PV, Carlswärd C, Martling C-R, Sundin Ö, Radell PJ: Short- and long-term follow-up of ICU patients after sedation with isoflurane and midazolam – a pilot study. Crit Care Med 2008, 36: 801-806.CrossRefPubMed
11.
go back to reference Kress JP, Gehlback B, Lacy M, Pliskin N, Pohlman AS, Hall JB: The long-term psychological effects of daily sedative interruption on critically ill patients. Am J Respir Crit Care Med 2003, 168: 1457-1461. 10.1164/rccm.200303-455OCCrossRefPubMed Kress JP, Gehlback B, Lacy M, Pliskin N, Pohlman AS, Hall JB: The long-term psychological effects of daily sedative interruption on critically ill patients. Am J Respir Crit Care Med 2003, 168: 1457-1461. 10.1164/rccm.200303-455OCCrossRefPubMed
12.
go back to reference Jacobi J, Fraser GL, Coursin DB, Riker RR, Fontaine D, Wittbrodt ET, Chalfin DB, Masica MF, Bjerke HS, Coplin WM, Crippen DW, Fuchs BD, Kelleher RM, Marik PE, Nasraway SA Jr, Murray MJ, Peruzzi WT, Lumb PD: Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult. Crit Care Med 2002, 30: 119-141. 10.1097/00003246-200201000-00020CrossRefPubMed Jacobi J, Fraser GL, Coursin DB, Riker RR, Fontaine D, Wittbrodt ET, Chalfin DB, Masica MF, Bjerke HS, Coplin WM, Crippen DW, Fuchs BD, Kelleher RM, Marik PE, Nasraway SA Jr, Murray MJ, Peruzzi WT, Lumb PD: Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult. Crit Care Med 2002, 30: 119-141. 10.1097/00003246-200201000-00020CrossRefPubMed
14.
go back to reference Jones C, Griffiths RD, Humphris G, Skirrow PM: Memory, delusions, and the development of acute posttraumatic stress disorder-related symptoms after intensive care. Crit Care Med 2001, 29: 573-580. 10.1097/00003246-200103000-00019CrossRefPubMed Jones C, Griffiths RD, Humphris G, Skirrow PM: Memory, delusions, and the development of acute posttraumatic stress disorder-related symptoms after intensive care. Crit Care Med 2001, 29: 573-580. 10.1097/00003246-200103000-00019CrossRefPubMed
15.
go back to reference Ruokonen E, Parviainen I, Jakob SM, Nunes S, Kaukonen M, Shepherd ST, Sarapohja ST, Bratty JR, Takala J, for the Dexmedetomidine for Continuous Sedation Investigators: Dexmedetomidine versus propofol/midazolam for long-term sedation during mechanical ventilation. Intensive Care Med 2008, in press. Ruokonen E, Parviainen I, Jakob SM, Nunes S, Kaukonen M, Shepherd ST, Sarapohja ST, Bratty JR, Takala J, for the Dexmedetomidine for Continuous Sedation Investigators: Dexmedetomidine versus propofol/midazolam for long-term sedation during mechanical ventilation. Intensive Care Med 2008, in press.
16.
go back to reference Park G, Lane M, Rogers S, Bassett P: A comparison of hypnotic and analgesic based sedation in a general intensive care unit. Br J Anaesth 2007, 98: 76-82. 10.1093/bja/ael320CrossRefPubMed Park G, Lane M, Rogers S, Bassett P: A comparison of hypnotic and analgesic based sedation in a general intensive care unit. Br J Anaesth 2007, 98: 76-82. 10.1093/bja/ael320CrossRefPubMed
Metadata
Title
Frontal EEG for intensive care unit sedation: treating numbers or patients?
Author
Peter V Sackey
Publication date
01-10-2008
Publisher
BioMed Central
Published in
Critical Care / Issue 5/2008
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc7029

Other articles of this Issue 5/2008

Critical Care 5/2008 Go to the issue