Published in: Critical Care 6/2005

Open Access 01-12-2005 | Research

Quantifying bedside-derived imaging of microcirculatory abnormalities in septic patients: a prospective validation study

Authors: E Christiaan Boerma, Keshen R Mathura, Peter HJ van der Voort, Peter E Spronk, Can Ince

Published in: Critical Care | Issue 6/2005

Login to get access

Abstract

Introduction

The introduction of orthogonal polarization spectral (OPS) imaging in clinical research has elucidated new perspectives on the role of microcirculatory flow abnormalities in the pathogenesis of sepsis. Essential to the process of understanding and reproducing these abnormalities is the method of quantification of flow scores.

Methods

In a consensus meeting with collaboraters from six research centres in different fields of experience with microcirculatory OPS imaging, premeditated qualifications for a simple, translucent and reproducible way of flow scoring were defined. Consecutively, a single-centre prospective observational validation study was performed in a group of 12 patients with an abdominal sepsis and a new stoma. Flow images of the microcirculation in vascular beds of the sublingual and stoma region were obtained, processed and analysed in a standardised way. We validated intra-observer and inter-observer reproducibility with kappa cross-tables for both types of microvascular beds.

Results

Agreement and kappa coefficients were >85% and >0.75, respectively, for interrater and intrarater variability in quantification of flow abnormalities during sepsis, in different subsets of microvascular architecture.

Conclusion

Semi-quantitative analysis of microcirculatory flow, as described, provides a reproducible and transparent tool in clinical research to monitor and evaluate the microcirculation during sepsis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sakr Y, Dubois MJ, De Backer D, Creteur J, Vincent JL: Persistent microcirculatory alterations are associated with organ failure and death in patients with septic shock. Crit Care Med 2004, 32: 1825-1831.CrossRefPubMed Sakr Y, Dubois MJ, De Backer D, Creteur J, Vincent JL: Persistent microcirculatory alterations are associated with organ failure and death in patients with septic shock. Crit Care Med 2004, 32: 1825-1831.CrossRefPubMed
2.
go back to reference Ince C: Microcirculation in distress: a new resuscitation end point. Crit Care Med 2004, 32: 1963-1964.CrossRefPubMed Ince C: Microcirculation in distress: a new resuscitation end point. Crit Care Med 2004, 32: 1963-1964.CrossRefPubMed
3.
go back to reference Slaaf DW, Tangelder GJ, Reneman RS: A versatile incident illuminator for intravital microscopy. Int J Microcirc Clin Exp 1987, 6: 391-397.PubMed Slaaf DW, Tangelder GJ, Reneman RS: A versatile incident illuminator for intravital microscopy. Int J Microcirc Clin Exp 1987, 6: 391-397.PubMed
4.
go back to reference Mathura KR, Alić L, Ince C: Initial clinical experience with OPS imaging for observation of the human microcirculation. In Yearbook of Intensive Care and Emergency Medicine. Edited by: Vincent JL. New York: Springer-Verlag; 2001:233-245. Mathura KR, Alić L, Ince C: Initial clinical experience with OPS imaging for observation of the human microcirculation. In Yearbook of Intensive Care and Emergency Medicine. Edited by: Vincent JL. New York: Springer-Verlag; 2001:233-245.
5.
go back to reference Mathura KR, Bouma GJ, Ince C: Abnormal microcirculation in brain tumours during surgery. Lancet 2001, 358: 1698-1699.CrossRefPubMed Mathura KR, Bouma GJ, Ince C: Abnormal microcirculation in brain tumours during surgery. Lancet 2001, 358: 1698-1699.CrossRefPubMed
6.
go back to reference Spronk PE, Ince C, Gardien MJ, Mathura KR, Oudemans-van Straaten HM, Zandstra DF: Nitroglycerin in septic shock after intravascular volume resuscitation. Lancet 2002, 360: 1395-1396.CrossRefPubMed Spronk PE, Ince C, Gardien MJ, Mathura KR, Oudemans-van Straaten HM, Zandstra DF: Nitroglycerin in septic shock after intravascular volume resuscitation. Lancet 2002, 360: 1395-1396.CrossRefPubMed
7.
go back to reference De Backer D, Creteur J, Preiser JC, Dubois MJ, Vincent JL: Microvascular blood flow is altered in patients with sepsis. Am J Respir Crit Care Med 2002, 166: 98-104.CrossRefPubMed De Backer D, Creteur J, Preiser JC, Dubois MJ, Vincent JL: Microvascular blood flow is altered in patients with sepsis. Am J Respir Crit Care Med 2002, 166: 98-104.CrossRefPubMed
8.
go back to reference De Backer, Creteur J, Vincent JL: Use of orthogonal polarization spectral imaging in intensive care. Orthogonal polarization spectral imaging. Prog Appl Microcirc 2000, 24: 104-109.CrossRef De Backer, Creteur J, Vincent JL: Use of orthogonal polarization spectral imaging in intensive care. Orthogonal polarization spectral imaging. Prog Appl Microcirc 2000, 24: 104-109.CrossRef
9.
go back to reference Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG: Orthogonal polarization spectral imaging: A new method for study of the microcirculation. Nat Med 1999, 5: 1209-1212.CrossRefPubMed Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG: Orthogonal polarization spectral imaging: A new method for study of the microcirculation. Nat Med 1999, 5: 1209-1212.CrossRefPubMed
10.
go back to reference Harris AG, Sinitsina I, Messmer K: The cytoscanTM model E-II, a new reflectance microscope for intravital microscopy: comparison with the standard fluorescence method. J Vasc Res 2000, 37: 469-476.CrossRefPubMed Harris AG, Sinitsina I, Messmer K: The cytoscanTM model E-II, a new reflectance microscope for intravital microscopy: comparison with the standard fluorescence method. J Vasc Res 2000, 37: 469-476.CrossRefPubMed
11.
go back to reference Ince C, Ashruf JF, Avontuur JA, Wieringa PA, Spaan JA, Bruining HA: Heterogeneity of the hypoxic state in rat heart is determined at the capillary level. Am J Physiol 1993, 264: H294-H301.PubMed Ince C, Ashruf JF, Avontuur JA, Wieringa PA, Spaan JA, Bruining HA: Heterogeneity of the hypoxic state in rat heart is determined at the capillary level. Am J Physiol 1993, 264: H294-H301.PubMed
12.
13.
go back to reference Cohen J: A coefficient of agreement for nominal scales. Educ Psychol Meas 1960, 20: 37-46.CrossRef Cohen J: A coefficient of agreement for nominal scales. Educ Psychol Meas 1960, 20: 37-46.CrossRef
14.
go back to reference Cohen J: Weighted kappa: nominal scale agreement with provision for scale disagreement or partial credit. Psychol Bull 1968, 70: 213-220.CrossRefPubMed Cohen J: Weighted kappa: nominal scale agreement with provision for scale disagreement or partial credit. Psychol Bull 1968, 70: 213-220.CrossRefPubMed
15.
go back to reference Weil MH, Nakagawa Y, Tang W: Sublingual capnometry: a new non-invasive measurement for diagnosis and quantitation of severity of circulatory shock. Crit Care Med 1999, 27: 1225-1229.CrossRefPubMed Weil MH, Nakagawa Y, Tang W: Sublingual capnometry: a new non-invasive measurement for diagnosis and quantitation of severity of circulatory shock. Crit Care Med 1999, 27: 1225-1229.CrossRefPubMed
16.
17.
go back to reference Schwarte LA, Fournell A, van Bommel J, Ince C: Redistribution of intestinal microcirculatory oxygenation during acute hemodilution in pigs. J Appl Physiol 2005, 98: 1070-1075.CrossRefPubMed Schwarte LA, Fournell A, van Bommel J, Ince C: Redistribution of intestinal microcirculatory oxygenation during acute hemodilution in pigs. J Appl Physiol 2005, 98: 1070-1075.CrossRefPubMed
18.
go back to reference Buise MP, Ince C, Tilanus HW, Gommers D, van Bommel J: The effect of nitroglycerin on microvascular perfusion and oxygenation during gastric tube reconstruction. Anesth Analg 2005, 100: 1107-1111.CrossRefPubMed Buise MP, Ince C, Tilanus HW, Gommers D, van Bommel J: The effect of nitroglycerin on microvascular perfusion and oxygenation during gastric tube reconstruction. Anesth Analg 2005, 100: 1107-1111.CrossRefPubMed
19.
go back to reference Boerma EC, van der Voort PHJ, Ince C: Sublingual microcirculatory flow is impaired by the vasopressin-analogue terlipressin in a patient with catecholamine-resistant septic shock. Acta Anaesthesiol Scand 2005, 49: 1387-1390.CrossRefPubMed Boerma EC, van der Voort PHJ, Ince C: Sublingual microcirculatory flow is impaired by the vasopressin-analogue terlipressin in a patient with catecholamine-resistant septic shock. Acta Anaesthesiol Scand 2005, 49: 1387-1390.CrossRefPubMed
20.
go back to reference Gutierrez G: The rate of oxygen release and its effect on capillary O2 tension: a mathematical analysis. Respir Physiol 1986, 63: 79-96.CrossRefPubMed Gutierrez G: The rate of oxygen release and its effect on capillary O2 tension: a mathematical analysis. Respir Physiol 1986, 63: 79-96.CrossRefPubMed
22.
go back to reference Lindeboom JAH, Mathura KR: Microvascular changes in alveolar distraction osteogenesis. J Vasc Res 2004,41(suppl 2):3.1. Lindeboom JAH, Mathura KR: Microvascular changes in alveolar distraction osteogenesis. J Vasc Res 2004,41(suppl 2):3.1.
Metadata
Title
Quantifying bedside-derived imaging of microcirculatory abnormalities in septic patients: a prospective validation study
Authors
E Christiaan Boerma
Keshen R Mathura
Peter HJ van der Voort
Peter E Spronk
Can Ince
Publication date
01-12-2005
Publisher
BioMed Central
Published in
Critical Care / Issue 6/2005
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc3809

Other articles of this Issue 6/2005

Critical Care 6/2005 Go to the issue