Skip to main content
Top
Published in: Critical Care 5/2004

Open Access 01-10-2004 | Research

The outcome of extubation failure in a community hospital intensive care unit: a cohort study

Authors: Christopher W Seymour, Anthony Martinez, Jason D Christie, Barry D Fuchs

Published in: Critical Care | Issue 5/2004

Login to get access

Abstract

Introduction

Extubation failure has been associated with poor intensive care unit (ICU) and hospital outcomes in tertiary care medical centers. Given the large proportion of critical care delivered in the community setting, our purpose was to determine the impact of extubation failure on patient outcomes in a community hospital ICU.

Methods

A retrospective cohort study was performed using data gathered in a 16-bed medical/surgical ICU in a community hospital. During 30 months, all patients with acute respiratory failure admitted to the ICU were included in the source population if they were mechanically ventilated by endotracheal tube for more than 12 hours. Extubation failure was defined as reinstitution of mechanical ventilation within 72 hours (n = 60), and the control cohort included patients who were successfully extubated at 72 hours (n = 93).

Results

The primary outcome was total ICU length of stay after the initial extubation. Secondary outcomes were total hospital length of stay after the initial extubation, ICU mortality, hospital mortality, and total hospital cost. Patient groups were similar in terms of age, sex, and severity of illness, as assessed using admission Acute Physiology and Chronic Health Evaluation II score (P > 0.05). Both ICU (1.0 versus 10 days; P < 0.01) and hospital length of stay (6.0 versus 17 days; P < 0.01) after initial extubation were significantly longer in reintubated patients. ICU mortality was significantly higher in patients who failed extubation (odds ratio = 12.2, 95% confidence interval [CI] = 1.5–101; P < 0.05), but there was no significant difference in hospital mortality (odds ratio = 2.1, 95% CI = 0.8–5.4; P < 0.15). Total hospital costs (estimated from direct and indirect charges) were significantly increased by a mean of US$33,926 (95% CI = US$22,573–45,280; P < 0.01).

Conclusion

Extubation failure in a community hospital is univariately associated with prolonged inpatient care and significantly increased cost. Corroborating data from tertiary care centers, these adverse outcomes highlight the importance of accurate predictors of extubation outcome.
Appendix
Available only for authorised users
Literature
1.
go back to reference Esteban A, Frutos F, Tobin M, Alia I, Solsona J, Valverdu I, Fernandez R, De la Cal JF, Benito S, Tomas R, et al.: A comparison of four methods of weaning patients from mechanical ventilation. N Engl J Med 1995, 332: 345–352. 10.1056/NEJM199502093320601CrossRef Esteban A, Frutos F, Tobin M, Alia I, Solsona J, Valverdu I, Fernandez R, De la Cal JF, Benito S, Tomas R, et al.: A comparison of four methods of weaning patients from mechanical ventilation. N Engl J Med 1995, 332: 345–352. 10.1056/NEJM199502093320601CrossRef
2.
go back to reference Ely E, Baker A, Dunagon D, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF: Effect on duration of mechanical ventilation of identifying patient capable of breathing spontaneously. N Engl J Med 1996, 335: 1864–1869. 10.1056/NEJM199612193352502CrossRef Ely E, Baker A, Dunagon D, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF: Effect on duration of mechanical ventilation of identifying patient capable of breathing spontaneously. N Engl J Med 1996, 335: 1864–1869. 10.1056/NEJM199612193352502CrossRef
3.
go back to reference Vallverdu I, Calaf N, Subirana M, Net A, Benito S, Mancebo J: Clinical characteristics, respiratory functional parameters and outcome of a 2-hour T-piece trial in patients weaning from mechanical ventilation. Am J Respir Crit Care Med 1998, 158: 1855–1862.CrossRef Vallverdu I, Calaf N, Subirana M, Net A, Benito S, Mancebo J: Clinical characteristics, respiratory functional parameters and outcome of a 2-hour T-piece trial in patients weaning from mechanical ventilation. Am J Respir Crit Care Med 1998, 158: 1855–1862.CrossRef
4.
go back to reference Pronovost PJ, Garrett E, Dorman T, Jenckes M, Webb TH III, Breslow M, Rosenfeld B, Bass E: Variations in complication rates and opportunities for improvement in quality of care for patients having abdominal aortic surgery. Lang Arch Surg 2001, 386: 249–256. 10.1007/s004230100216CrossRef Pronovost PJ, Garrett E, Dorman T, Jenckes M, Webb TH III, Breslow M, Rosenfeld B, Bass E: Variations in complication rates and opportunities for improvement in quality of care for patients having abdominal aortic surgery. Lang Arch Surg 2001, 386: 249–256. 10.1007/s004230100216CrossRef
5.
go back to reference Esteban A, Alia I, Gordo F, Fernandez R, Solsona JF, Vallverdu I, Macias S, Allegue JM, Blanco J, Carriedo D, et al.: Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation. The Spanish Lung Failure Collaborative Group. Am J Respir Crit Care Med 1997, 156: 459–465.CrossRef Esteban A, Alia I, Gordo F, Fernandez R, Solsona JF, Vallverdu I, Macias S, Allegue JM, Blanco J, Carriedo D, et al.: Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation. The Spanish Lung Failure Collaborative Group. Am J Respir Crit Care Med 1997, 156: 459–465.CrossRef
6.
go back to reference Epstein S, Ciubotaru R, Wong J: Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997, 112: 186–192.CrossRef Epstein S, Ciubotaru R, Wong J: Effect of failed extubation on the outcome of mechanical ventilation. Chest 1997, 112: 186–192.CrossRef
7.
go back to reference Rady MY, Ryan T: Perioperative predictors of extubation failure and the effect on clinical outcome after cardiac surgery. Crit Care Med 1999, 27: 340–347. 10.1097/00003246-199902000-00041CrossRef Rady MY, Ryan T: Perioperative predictors of extubation failure and the effect on clinical outcome after cardiac surgery. Crit Care Med 1999, 27: 340–347. 10.1097/00003246-199902000-00041CrossRef
8.
go back to reference Dupont H, LePort Y, Paugham-Burtz C, Mantz J, Desmonts M: Re-intubation after planned extubation in surgical ICU patients: a case-control study. Intensive Care Med 2001, 27: 1875–1880. 10.1007/s001340101101CrossRef Dupont H, LePort Y, Paugham-Burtz C, Mantz J, Desmonts M: Re-intubation after planned extubation in surgical ICU patients: a case-control study. Intensive Care Med 2001, 27: 1875–1880. 10.1007/s001340101101CrossRef
9.
go back to reference Epstein SK, Ciubotaru RL: Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med 1998, 158: 489–493.CrossRef Epstein SK, Ciubotaru RL: Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med 1998, 158: 489–493.CrossRef
10.
go back to reference Torres A, Gatell J, Aznar E, El-Ebiary M, Puig de la Bellacasa J, Gonzalez J, Ferrer M, Rodriguez-Roisin R: Re-intubation increases the risk of nosocomial pneumonia in patients needing mechanical ventilation. Am J Respir Crit Care Med 1995, 152: 137–141.CrossRef Torres A, Gatell J, Aznar E, El-Ebiary M, Puig de la Bellacasa J, Gonzalez J, Ferrer M, Rodriguez-Roisin R: Re-intubation increases the risk of nosocomial pneumonia in patients needing mechanical ventilation. Am J Respir Crit Care Med 1995, 152: 137–141.CrossRef
11.
go back to reference Pines JM, Fager SS, Milzman DP: A review of costing methodologies in critical care studies. J Crit Care 2002, 17: 181–186. 10.1053/jcrc.2002.35811CrossRef Pines JM, Fager SS, Milzman DP: A review of costing methodologies in critical care studies. J Crit Care 2002, 17: 181–186. 10.1053/jcrc.2002.35811CrossRef
Metadata
Title
The outcome of extubation failure in a community hospital intensive care unit: a cohort study
Authors
Christopher W Seymour
Anthony Martinez
Jason D Christie
Barry D Fuchs
Publication date
01-10-2004
Publisher
BioMed Central
Published in
Critical Care / Issue 5/2004
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc2913

Other articles of this Issue 5/2004

Critical Care 5/2004 Go to the issue