Skip to main content
Top
Published in: Critical Care 1/2013

Open Access 01-02-2013 | Research

Rule out of acute aortic dissection with plasma matrix metalloproteinase 8 in the emergency department

Authors: Francesca Giachino, Marilena Loiacono, Manuela Lucchiari, Maria Manzo, Stefania Battista, Elisa Saglio, Enrico Lupia, Corrado Moiraghi, Emilio Hirsch, Giulio Mengozzi, Fulvio Morello

Published in: Critical Care | Issue 1/2013

Login to get access

Abstract

Introduction

Matrix metalloproteinases (MMPs) are involved in aortic pathophysiology. Preliminary studies have detected increased plasma levels of MMP8 and MMP9 in patients with acute aortic dissection (AAD). However, the performance of plasma MMP8 and MMP9 for the diagnosis of AAD in the emergency department is at present unknown.

Methods

The levels of MMP8 and MMP9 were measured by ELISA on plasma samples obtained from 126 consecutive patients evaluated in the emergency department for suspected AAD. All patients were subjected to urgent computed tomography (CT) scan for final diagnosis.

Results

In the study cohort (N = 126), AAD was diagnosed in 52 patients and ruled out in 74 patients. Median plasma MMP8 levels were 36.4 (interquartile range 24.8 to 69.3) ng/ml in patients with AAD and 13.2 (8.1 to 31.8) ng/ml in patients receiving an alternative final diagnosis (P <0.0001). Median plasma MMP9 levels were 169.2 (93.0 to 261.8) ng/ml in patients with AAD and 80.5 (41.8 to 140.6) ng/ml in patients receiving an alternative final diagnosis (P = 0.001). The area under the curve (AUC) on receiver-operating characteristic (ROC) analysis of MMP8 and MMP9 for the diagnosis of AAD was respectively 0.75 and 0.70, as compared to 0.87 of D-dimer. At the cutoff of 3.6 ng/ml, plasma MMP8 had a sensitivity of 100.0% (95% CI, 93.2% to 100.0%) and a specificity of 9.5% (95% CI, 3.9% to 18.5%) and ruled out AAD in 5.6% of patients. Combination of plasma MMP8 with D-dimer increased the AUC on ROC analysis to 0.89. Presence of MMP8 <11.0 ng/ml and D-dimer <1.0 or <2.0 µg/ml provided a negative predictive value of 100% and ruled out AAD in 13.6% and 21.4% of patients respectively.

Conclusions

Low levels of plasma MMP8 can rule out AAD in a minority of patients. Combination of plasma MMP8 and D-dimer at individually suboptimal cutoffs could safely rule out AAD in a substantial proportion of patients evaluated in the emergency department.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tsai TT, Trimarchi S, Nienaber CA: Acute aortic dissection: perspectives from the International Registry of Acute Aortic Dissection (IRAD). Eur J Vasc Endovasc Surg 2009, 37: 149-159. 10.1016/j.ejvs.2008.11.032CrossRefPubMed Tsai TT, Trimarchi S, Nienaber CA: Acute aortic dissection: perspectives from the International Registry of Acute Aortic Dissection (IRAD). Eur J Vasc Endovasc Surg 2009, 37: 149-159. 10.1016/j.ejvs.2008.11.032CrossRefPubMed
2.
go back to reference Nienaber CA, Powell JT: Management of acute aortic syndromes. Eur Heart J 2012, 33: 26-35b. 10.1093/eurheartj/ehr186CrossRefPubMed Nienaber CA, Powell JT: Management of acute aortic syndromes. Eur Heart J 2012, 33: 26-35b. 10.1093/eurheartj/ehr186CrossRefPubMed
3.
go back to reference Hagan PG, Nienaber CA, Isselbacher EM, Bruckman D, Karavite DJ, Russman PL, Evangelista A, Fattori R, Suzuki T, Oh JK, Moore AG, Malouf JF, Pape LA, Gaca C, Sechtem U, Lenferink S, Deutsch HJ, Diedrichs H, Marcos y Robles J, Llovet A, Gilon D, Das SK, Armstrong WF, Deeb GM, Eagle KA: The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease. JAMA 2000, 283: 897-903. 10.1001/jama.283.7.897CrossRefPubMed Hagan PG, Nienaber CA, Isselbacher EM, Bruckman D, Karavite DJ, Russman PL, Evangelista A, Fattori R, Suzuki T, Oh JK, Moore AG, Malouf JF, Pape LA, Gaca C, Sechtem U, Lenferink S, Deutsch HJ, Diedrichs H, Marcos y Robles J, Llovet A, Gilon D, Das SK, Armstrong WF, Deeb GM, Eagle KA: The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease. JAMA 2000, 283: 897-903. 10.1001/jama.283.7.897CrossRefPubMed
4.
go back to reference Clouse WD, Hallett JW Jr, Schaff HV, Spittell PC, Rowland CM, Ilstrup DM, Melton LJ: Acute aortic dissection: population-based incidence compared with degenerative aortic aneurysm rupture. Mayo Clin Proc 2004, 79: 176-180. 10.4065/79.2.176CrossRefPubMed Clouse WD, Hallett JW Jr, Schaff HV, Spittell PC, Rowland CM, Ilstrup DM, Melton LJ: Acute aortic dissection: population-based incidence compared with degenerative aortic aneurysm rupture. Mayo Clin Proc 2004, 79: 176-180. 10.4065/79.2.176CrossRefPubMed
5.
go back to reference Meszaros I, Morocz J, Szlavi J, Schmidt J, Tornoci L, Nagy L, Szep L: Epidemiology and clinicopathology of aortic dissection. Chest 2000, 117: 1271-1278. 10.1378/chest.117.5.1271CrossRefPubMed Meszaros I, Morocz J, Szlavi J, Schmidt J, Tornoci L, Nagy L, Szep L: Epidemiology and clinicopathology of aortic dissection. Chest 2000, 117: 1271-1278. 10.1378/chest.117.5.1271CrossRefPubMed
6.
go back to reference Marill KA: Serum D-dimer is a sensitive test for the detection of acute aortic dissection: a pooled meta-analysis. J Emerg Med 2008, 34: 367-376. 10.1016/j.jemermed.2007.06.030CrossRefPubMed Marill KA: Serum D-dimer is a sensitive test for the detection of acute aortic dissection: a pooled meta-analysis. J Emerg Med 2008, 34: 367-376. 10.1016/j.jemermed.2007.06.030CrossRefPubMed
7.
go back to reference Shimony A, Filion KB, Mottillo S, Dourian T, Eisenberg MJ: Meta-analysis of usefulness of d-dimer to diagnose acute aortic dissection. Am J Cardiol 2011, 107: 1227-1234. 10.1016/j.amjcard.2010.12.027CrossRefPubMed Shimony A, Filion KB, Mottillo S, Dourian T, Eisenberg MJ: Meta-analysis of usefulness of d-dimer to diagnose acute aortic dissection. Am J Cardiol 2011, 107: 1227-1234. 10.1016/j.amjcard.2010.12.027CrossRefPubMed
8.
go back to reference Suzuki T, Katoh H, Tsuchio Y, Hasegawa A, Kurabayashi M, Ohira A, Hiramori K, Sakomura Y, Kasanuki H, Hori S, Aikawa N, Abe S, Tei C, Nakagawa Y, Nobuyoshi M, Misu K, Sumiyoshi T, Nagai R: Diagnostic implications of elevated levels of smooth-muscle myosin heavy-chain protein in acute aortic dissection. The smooth muscle myosin heavy chain study. Ann Intern Med 2000, 133: 537-541.CrossRefPubMed Suzuki T, Katoh H, Tsuchio Y, Hasegawa A, Kurabayashi M, Ohira A, Hiramori K, Sakomura Y, Kasanuki H, Hori S, Aikawa N, Abe S, Tei C, Nakagawa Y, Nobuyoshi M, Misu K, Sumiyoshi T, Nagai R: Diagnostic implications of elevated levels of smooth-muscle myosin heavy-chain protein in acute aortic dissection. The smooth muscle myosin heavy chain study. Ann Intern Med 2000, 133: 537-541.CrossRefPubMed
9.
go back to reference Shinohara T, Suzuki K, Okada M, Shiigai M, Shimizu M, Maehara T, Ohsuzu F: Soluble elastin fragments in serum are elevated in acute aortic dissection. Arterioscler Thromb Vasc Biol 2003, 23: 1839-1844. 10.1161/01.ATV.0000085016.02363.80CrossRefPubMed Shinohara T, Suzuki K, Okada M, Shiigai M, Shimizu M, Maehara T, Ohsuzu F: Soluble elastin fragments in serum are elevated in acute aortic dissection. Arterioscler Thromb Vasc Biol 2003, 23: 1839-1844. 10.1161/01.ATV.0000085016.02363.80CrossRefPubMed
10.
go back to reference Suzuki T, Distante A, Zizza A, Trimarchi S, Villani M, Salerno Uriarte JA, de Luca Tupputi Schinosa L, Renzulli A, Sabino F, Nowak R, Birkhahn R, Hollander JE, Counselman F, Bossone E, Eagle K: Preliminary experience with the smooth muscle troponin-like protein, calponin, as a novel biomarker for diagnosing acute aortic dissection. Eur Heart J 2008, 29: 1439-1445. 10.1093/eurheartj/ehn162CrossRefPubMed Suzuki T, Distante A, Zizza A, Trimarchi S, Villani M, Salerno Uriarte JA, de Luca Tupputi Schinosa L, Renzulli A, Sabino F, Nowak R, Birkhahn R, Hollander JE, Counselman F, Bossone E, Eagle K: Preliminary experience with the smooth muscle troponin-like protein, calponin, as a novel biomarker for diagnosing acute aortic dissection. Eur Heart J 2008, 29: 1439-1445. 10.1093/eurheartj/ehn162CrossRefPubMed
11.
go back to reference Vu TH, Werb Z: Matrix metalloproteinases: effectors of development and normal physiology. Genes Dev 2000, 14: 2123-2133. 10.1101/gad.815400CrossRefPubMed Vu TH, Werb Z: Matrix metalloproteinases: effectors of development and normal physiology. Genes Dev 2000, 14: 2123-2133. 10.1101/gad.815400CrossRefPubMed
12.
13.
go back to reference Freestone T, Turner RJ, Coady A, Higman DJ, Greenhalgh RM, Powell JT: Inflammation and matrix metalloproteinases in the enlarging abdominal aortic aneurysm. Arterioscler Thromb Vasc Biol 1995, 15: 1145-1151. 10.1161/01.ATV.15.8.1145CrossRefPubMed Freestone T, Turner RJ, Coady A, Higman DJ, Greenhalgh RM, Powell JT: Inflammation and matrix metalloproteinases in the enlarging abdominal aortic aneurysm. Arterioscler Thromb Vasc Biol 1995, 15: 1145-1151. 10.1161/01.ATV.15.8.1145CrossRefPubMed
14.
go back to reference Tung WS, Lee JK, Thompson RW: Simultaneous analysis of 1176 gene products in normal human aorta and abdominal aortic aneurysms using a membrane-based complementary DNA expression array. J Vasc Surg 2001, 34: 143-150. 10.1067/mva.2001.113310CrossRefPubMed Tung WS, Lee JK, Thompson RW: Simultaneous analysis of 1176 gene products in normal human aorta and abdominal aortic aneurysms using a membrane-based complementary DNA expression array. J Vasc Surg 2001, 34: 143-150. 10.1067/mva.2001.113310CrossRefPubMed
15.
go back to reference Koullias GJ, Ravichandran P, Korkolis DP, Rimm DL, Elefteriades JA: Increased tissue microarray matrix metalloproteinase expression favors proteolysis in thoracic aortic aneurysms and dissections. Ann Thorac Surg 2004, 78: 2106-2111. 10.1016/j.athoracsur.2004.05.088CrossRefPubMed Koullias GJ, Ravichandran P, Korkolis DP, Rimm DL, Elefteriades JA: Increased tissue microarray matrix metalloproteinase expression favors proteolysis in thoracic aortic aneurysms and dissections. Ann Thorac Surg 2004, 78: 2106-2111. 10.1016/j.athoracsur.2004.05.088CrossRefPubMed
16.
go back to reference Didangelos A, Yin X, Mandal K, Baumert M, Jahangiri M, Mayr M: Proteomics characterization of extracellular space components in the human aorta. Mol Cell Proteomics 2010, 9: 2048-2062. 10.1074/mcp.M110.001693PubMedCentralCrossRefPubMed Didangelos A, Yin X, Mandal K, Baumert M, Jahangiri M, Mayr M: Proteomics characterization of extracellular space components in the human aorta. Mol Cell Proteomics 2010, 9: 2048-2062. 10.1074/mcp.M110.001693PubMedCentralCrossRefPubMed
17.
go back to reference Golledge J, Tsao PS, Dalman RL, Norman PE: Circulating markers of abdominal aortic aneurysm presence and progression. Circulation 2008, 118: 2382-2392. 10.1161/CIRCULATIONAHA.108.802074PubMedCentralCrossRefPubMed Golledge J, Tsao PS, Dalman RL, Norman PE: Circulating markers of abdominal aortic aneurysm presence and progression. Circulation 2008, 118: 2382-2392. 10.1161/CIRCULATIONAHA.108.802074PubMedCentralCrossRefPubMed
18.
go back to reference Sangiorgi G, Trimarchi S, Mauriello A, Righini P, Bossone E, Suzuki T, Rampoldi V, Eagle KA: Plasma levels of metalloproteinases-9 and -2 in the acute and subacute phases of type A and type B aortic dissection. J Cardiovasc Med (Hagerstown) 2006, 7: 307-315. 10.2459/01.JCM.0000223251.26988.c5CrossRef Sangiorgi G, Trimarchi S, Mauriello A, Righini P, Bossone E, Suzuki T, Rampoldi V, Eagle KA: Plasma levels of metalloproteinases-9 and -2 in the acute and subacute phases of type A and type B aortic dissection. J Cardiovasc Med (Hagerstown) 2006, 7: 307-315. 10.2459/01.JCM.0000223251.26988.c5CrossRef
19.
go back to reference Wen T, Liu L, Xiong GZ: Matrix metalloproteinase levels in acute aortic dissection, acute pancreatitis and other abdominal pain. Emerg Med J 2009, 26: 715-718. 10.1136/emj.2008.067645CrossRefPubMed Wen T, Liu L, Xiong GZ: Matrix metalloproteinase levels in acute aortic dissection, acute pancreatitis and other abdominal pain. Emerg Med J 2009, 26: 715-718. 10.1136/emj.2008.067645CrossRefPubMed
20.
go back to reference Li Y, Shao AZ, Jiang HT, Dong GH, Xu B, Yi J, Jing H: The prominent expression of plasma matrix metalloproteinase-8 in acute thoracic aortic dissection. J Surg Res 2010, 163: e99-104. 10.1016/j.jss.2010.05.030CrossRefPubMed Li Y, Shao AZ, Jiang HT, Dong GH, Xu B, Yi J, Jing H: The prominent expression of plasma matrix metalloproteinase-8 in acute thoracic aortic dissection. J Surg Res 2010, 163: e99-104. 10.1016/j.jss.2010.05.030CrossRefPubMed
21.
go back to reference Wen D, Zhou XL, Li JJ, Luo F, Zhang L, Gao LG, Wang LP, Song L, Sun K, Zou YB, Zhang CN, Hui RT: Plasma concentrations of interleukin-6, C-reactive protein, tumor necrosis factor-α and matrix metalloproteinase-9 in aortic dissection. Clin Chim Acta 2012, 413: 198-202. 10.1016/j.cca.2011.09.029CrossRefPubMed Wen D, Zhou XL, Li JJ, Luo F, Zhang L, Gao LG, Wang LP, Song L, Sun K, Zou YB, Zhang CN, Hui RT: Plasma concentrations of interleukin-6, C-reactive protein, tumor necrosis factor-α and matrix metalloproteinase-9 in aortic dissection. Clin Chim Acta 2012, 413: 198-202. 10.1016/j.cca.2011.09.029CrossRefPubMed
22.
go back to reference Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE, Eagle KA, Hermann LK, Isselbacher EM, Kazerooni EA, Kouchoukos NT, Lytle BW, Milewicz DM, Reich DL, Sen S, Shinn JA, Svensson LG, Williams DM: 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation 2010, 121: e266-369.CrossRefPubMed Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE, Eagle KA, Hermann LK, Isselbacher EM, Kazerooni EA, Kouchoukos NT, Lytle BW, Milewicz DM, Reich DL, Sen S, Shinn JA, Svensson LG, Williams DM: 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with Thoracic Aortic Disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. Circulation 2010, 121: e266-369.CrossRefPubMed
23.
go back to reference Hanley JA, McNeil BJ: The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982, 143: 29-36.CrossRefPubMed Hanley JA, McNeil BJ: The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982, 143: 29-36.CrossRefPubMed
24.
go back to reference Olsson C, Thelin S, Stahle E, Ekbom A, Granath F: Thoracic aortic aneurysm and dissection. Circulation 2006, 114: 2611-2618. 10.1161/CIRCULATIONAHA.106.630400CrossRefPubMed Olsson C, Thelin S, Stahle E, Ekbom A, Granath F: Thoracic aortic aneurysm and dissection. Circulation 2006, 114: 2611-2618. 10.1161/CIRCULATIONAHA.106.630400CrossRefPubMed
25.
go back to reference Guo J, Xue P, Yang XN, Liu XB, Huang W, Xia Q: Serum matrix metalloproteinase-9 is an early marker of pancreatic necrosis in patients with severe acute pancreatitis. Hepatogastroenterology 2012, 59: 1594-1598.PubMed Guo J, Xue P, Yang XN, Liu XB, Huang W, Xia Q: Serum matrix metalloproteinase-9 is an early marker of pancreatic necrosis in patients with severe acute pancreatitis. Hepatogastroenterology 2012, 59: 1594-1598.PubMed
26.
go back to reference Suzuki T, Distante A, Zizza A, Trimarchi S, Villani M, Salerno Uriarte JA, De Luca Tupputi Schinosa L, Renzulli A, Sabino F, Nowak R, Birkhahn R, Hollander JE, Counselman F, Vijayendran R, Bossone E, Eagle K: Diagnosis of acute aortic dissection by D-dimer: the International Registry of Acute Aortic Dissection Substudy on Biomarkers (IRAD-Bio) experience. Circulation 2009, 119: 2702-2707. 10.1161/CIRCULATIONAHA.108.833004CrossRefPubMed Suzuki T, Distante A, Zizza A, Trimarchi S, Villani M, Salerno Uriarte JA, De Luca Tupputi Schinosa L, Renzulli A, Sabino F, Nowak R, Birkhahn R, Hollander JE, Counselman F, Vijayendran R, Bossone E, Eagle K: Diagnosis of acute aortic dissection by D-dimer: the International Registry of Acute Aortic Dissection Substudy on Biomarkers (IRAD-Bio) experience. Circulation 2009, 119: 2702-2707. 10.1161/CIRCULATIONAHA.108.833004CrossRefPubMed
27.
go back to reference Kocher KE, Meurer WJ, Fazel R, Scott PA, Krumholz HM, Nallamothu BK: National trends in use of computed tomography in the emergency department. Ann Emerg Med 2011, 58: 452-462. e453 10.1016/j.annemergmed.2011.05.020CrossRefPubMed Kocher KE, Meurer WJ, Fazel R, Scott PA, Krumholz HM, Nallamothu BK: National trends in use of computed tomography in the emergency department. Ann Emerg Med 2011, 58: 452-462. e453 10.1016/j.annemergmed.2011.05.020CrossRefPubMed
28.
go back to reference Rogers AM, Hermann LK, Booher AM, Nienaber CA, Williams DM, Kazerooni EA, Froehlich JB, O'Gara PT, Montgomery DG, Cooper JV, Harris KM, Hutchison S, Evangelista A, Isselbacher EM, Eagle KA: Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection. Circulation 2011, 123: 2213-2218. 10.1161/CIRCULATIONAHA.110.988568CrossRefPubMed Rogers AM, Hermann LK, Booher AM, Nienaber CA, Williams DM, Kazerooni EA, Froehlich JB, O'Gara PT, Montgomery DG, Cooper JV, Harris KM, Hutchison S, Evangelista A, Isselbacher EM, Eagle KA: Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection. Circulation 2011, 123: 2213-2218. 10.1161/CIRCULATIONAHA.110.988568CrossRefPubMed
Metadata
Title
Rule out of acute aortic dissection with plasma matrix metalloproteinase 8 in the emergency department
Authors
Francesca Giachino
Marilena Loiacono
Manuela Lucchiari
Maria Manzo
Stefania Battista
Elisa Saglio
Enrico Lupia
Corrado Moiraghi
Emilio Hirsch
Giulio Mengozzi
Fulvio Morello
Publication date
01-02-2013
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2013
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc12536

Other articles of this Issue 1/2013

Critical Care 1/2013 Go to the issue