Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting

Authors: Matthieu Biais, Cédric Carrié, François Delaunay, Nicolas Morel, Philippe Revel, Gérard Janvier

Published in: Critical Care | Issue 3/2012

Login to get access

Abstract

Introduction

In the emergency setting, focused cardiac ultrasound has become a fundamental tool for diagnostic, initial emergency treatment and triage decisions. A new ultra-miniaturized pocket ultrasound device (PUD) may be suited to this specific setting. Therefore, we aimed to compare the diagnostic ability of an ultra-miniaturized ultrasound device (Vscan™, GE Healthcare, Wauwatosa, WI) and of a conventional high-quality echocardiography system (Vivid S5™, GE Healthcare) for a cardiac focused ultrasonography in patients admitted to the emergency department.

Methods

During 4 months, patients admitted to our emergency department and requiring transthoracic echocardiography (TTE) were included in this single-center, prospective and observational study. Patients underwent TTE using a PUD and a conventional echocardiography system. Each examination was performed independently by a physician experienced in echocardiography, unaware of the results found by the alternative device. During the focused cardiac echocardiography, the following parameters were assessed: global cardiac systolic function, identification of ventricular enlargement or hypertrophy, assessment for pericardial effusion and estimation of the size and the respiratory changes of the inferior vena cava (IVC) diameter.

Results

One hundred fifty-one (151) patients were analyzed. With the tested PUD, the image quality was sufficient to perform focused cardiac ultrasonography in all patients. Examination using PUD adequately qualified with a very good agreement global left ventricular systolic dysfunction (κ = 0.87; 95%CI: 0.76-0.97), severe right ventricular dilation (κ = 0.87; 95%CI: 0.71-1.00), inferior vena cava dilation (κ = 0.90; 95%CI: 0.80-1.00), respiratory-induced variations in inferior vena cava size in spontaneous breathing (κ = 0.84; 95%CI: 0.71-0.98), pericardial effusion (κ = 0.75; 95%CI: 0.55-0.95) and compressive pericardial effusion (κ = 1.00; 95%CI: 1.00-1.00).

Conclusions

In an emergency setting, this new ultraportable echoscope (PUD) was reliable for the real-time detection of focused cardiac abnormalities.
Appendix
Available only for authorised users
Literature
1.
go back to reference American College of Emergency Physicians: Emergency ultrasound guidelines. Ann Emerg Med 2009, 53: 550-570.CrossRef American College of Emergency Physicians: Emergency ultrasound guidelines. Ann Emerg Med 2009, 53: 550-570.CrossRef
2.
go back to reference Beaulieu Y: Bedside echocardiography in the assessment of the critically ill. Crit Care Med 2007, 35: S235-249. 10.1097/01.CCM.0000260673.66681.AFCrossRefPubMed Beaulieu Y: Bedside echocardiography in the assessment of the critically ill. Crit Care Med 2007, 35: S235-249. 10.1097/01.CCM.0000260673.66681.AFCrossRefPubMed
3.
go back to reference Nelson BP, Melnick ER, Li J: Portable ultrasound for remote environments, Part I: Feasibility of field deployment. J Emerg Med 2011, 40: 190-197. 10.1016/j.jemermed.2009.09.006CrossRefPubMed Nelson BP, Melnick ER, Li J: Portable ultrasound for remote environments, Part I: Feasibility of field deployment. J Emerg Med 2011, 40: 190-197. 10.1016/j.jemermed.2009.09.006CrossRefPubMed
4.
go back to reference Price S, Via G, Sloth E, Guarracino F, Breitkreutz R, Catena E, Talmor D: Echocardiography practice, training and accreditation in the intensive care: document for the World Interactive Network Focused on Critical Ultrasound (WINFOCUS). Cardiovasc Ultrasound 2008, 6: 49. 10.1186/1476-7120-6-49PubMedCentralCrossRefPubMed Price S, Via G, Sloth E, Guarracino F, Breitkreutz R, Catena E, Talmor D: Echocardiography practice, training and accreditation in the intensive care: document for the World Interactive Network Focused on Critical Ultrasound (WINFOCUS). Cardiovasc Ultrasound 2008, 6: 49. 10.1186/1476-7120-6-49PubMedCentralCrossRefPubMed
5.
go back to reference Moore CL, Copel JA: Point-of-care ultrasonography. N Engl J Med 2011, 364: 749-757. 10.1056/NEJMra0909487CrossRefPubMed Moore CL, Copel JA: Point-of-care ultrasonography. N Engl J Med 2011, 364: 749-757. 10.1056/NEJMra0909487CrossRefPubMed
6.
go back to reference Atar S, Feldman A, Darawshe A, Siegel RJ, Rosenfeld T: Utility and diagnostic accuracy of hand-carried ultrasound for emergency room evaluation of chest pain. Am J Cardiol 2004, 94: 408-409. 10.1016/j.amjcard.2004.04.052CrossRefPubMed Atar S, Feldman A, Darawshe A, Siegel RJ, Rosenfeld T: Utility and diagnostic accuracy of hand-carried ultrasound for emergency room evaluation of chest pain. Am J Cardiol 2004, 94: 408-409. 10.1016/j.amjcard.2004.04.052CrossRefPubMed
7.
go back to reference Spevack DM, Spevack DM, Tunick PA, Kronzon I: Hand carried echocardiography in the critical care setting. Echocardiography 2003, 20: 455-461. 10.1046/j.1540-8175.2003.03083.xCrossRefPubMed Spevack DM, Spevack DM, Tunick PA, Kronzon I: Hand carried echocardiography in the critical care setting. Echocardiography 2003, 20: 455-461. 10.1046/j.1540-8175.2003.03083.xCrossRefPubMed
8.
go back to reference Vignon P, Frank MB, Lesage J, Mucke F, Francois B, Normand S, Bonnivard M, Clavel M, Gastinne H: Hand-held echocardiography with Doppler capability for the assessment of critically-ill patients: is it reliable? Intensive Care Med 2004, 30: 718-723. 10.1007/s00134-003-2128-xCrossRefPubMed Vignon P, Frank MB, Lesage J, Mucke F, Francois B, Normand S, Bonnivard M, Clavel M, Gastinne H: Hand-held echocardiography with Doppler capability for the assessment of critically-ill patients: is it reliable? Intensive Care Med 2004, 30: 718-723. 10.1007/s00134-003-2128-xCrossRefPubMed
9.
go back to reference Labovitz AJ, Noble VE, Bierig M, Goldstein SA, Jones R, Kort S, Porter TR, Spencer KT, Tayal VS, Wei K: Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians. J Am Soc Echocardiogr 2010, 23: 1225-1230. 10.1016/j.echo.2010.10.005CrossRefPubMed Labovitz AJ, Noble VE, Bierig M, Goldstein SA, Jones R, Kort S, Porter TR, Spencer KT, Tayal VS, Wei K: Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians. J Am Soc Echocardiogr 2010, 23: 1225-1230. 10.1016/j.echo.2010.10.005CrossRefPubMed
10.
go back to reference Mondillo S, Giannotti G, Innelli P, Ballo PC, Galderisi M: Hand-held echocardiography: its use and usefulness. Int J Cardiol 2006, 111: 1-5. 10.1016/j.ijcard.2005.07.002CrossRefPubMed Mondillo S, Giannotti G, Innelli P, Ballo PC, Galderisi M: Hand-held echocardiography: its use and usefulness. Int J Cardiol 2006, 111: 1-5. 10.1016/j.ijcard.2005.07.002CrossRefPubMed
11.
go back to reference Seward JB, Douglas PS, Erbel R, Kerber RE, Kronzon I, Rakowski H, Sahn LD, Sisk EJ, Tajik AJ, Wann S: Hand-carried cardiac ultrasound (HCU) device: recommendations regarding new technology. A report from the Echocardiography Task Force on New Technology of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 2002, 15: 369-373. 10.1067/mje.2002.123026CrossRefPubMed Seward JB, Douglas PS, Erbel R, Kerber RE, Kronzon I, Rakowski H, Sahn LD, Sisk EJ, Tajik AJ, Wann S: Hand-carried cardiac ultrasound (HCU) device: recommendations regarding new technology. A report from the Echocardiography Task Force on New Technology of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 2002, 15: 369-373. 10.1067/mje.2002.123026CrossRefPubMed
12.
go back to reference Egan M, Ionescu A: The pocket echocardiograph: a useful new tool? Eur J Echocardiogr 2008, 9: 721-725. 10.1093/ejechocard/jen177CrossRefPubMed Egan M, Ionescu A: The pocket echocardiograph: a useful new tool? Eur J Echocardiogr 2008, 9: 721-725. 10.1093/ejechocard/jen177CrossRefPubMed
13.
go back to reference Manasia AR, Nagaraj HM, Kodali RB, Croft LB, Oropello JM, Kohli-Seth R, Leibowitz AB, DelGiudice R, Hufanda JF, Benjamin E, Goldman ME: Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients. J Cardiothorac Vasc Anesth 2005, 19: 155-159. 10.1053/j.jvca.2005.01.023CrossRefPubMed Manasia AR, Nagaraj HM, Kodali RB, Croft LB, Oropello JM, Kohli-Seth R, Leibowitz AB, DelGiudice R, Hufanda JF, Benjamin E, Goldman ME: Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients. J Cardiothorac Vasc Anesth 2005, 19: 155-159. 10.1053/j.jvca.2005.01.023CrossRefPubMed
14.
go back to reference Scholten C, Rosenhek R, Binder T, Zehetgruber M, Maurer G, Baumgartner H: Hand-held miniaturized cardiac ultrasound instruments for rapid and effective bedside diagnosis and patient screening. J Eval Clin Pract 2005, 11: 67-72. 10.1111/j.1365-2753.2004.00506.xCrossRefPubMed Scholten C, Rosenhek R, Binder T, Zehetgruber M, Maurer G, Baumgartner H: Hand-held miniaturized cardiac ultrasound instruments for rapid and effective bedside diagnosis and patient screening. J Eval Clin Pract 2005, 11: 67-72. 10.1111/j.1365-2753.2004.00506.xCrossRefPubMed
15.
go back to reference Vignon P, Chastagner C, Francois B, Martaille JF, Normand S, Bonnivard M, Gastinne H: Diagnostic ability of hand-held echocardiography in ventilated critically ill patients. Crit Care 2003, 7: R84-91. 10.1186/cc2360PubMedCentralCrossRefPubMed Vignon P, Chastagner C, Francois B, Martaille JF, Normand S, Bonnivard M, Gastinne H: Diagnostic ability of hand-held echocardiography in ventilated critically ill patients. Crit Care 2003, 7: R84-91. 10.1186/cc2360PubMedCentralCrossRefPubMed
16.
go back to reference Amiel JB, Grumann A, Lheritier G, Clavel M, Francois B, Pichon N, Dugard A, Marin B, Vignon P: Assessment of left ventricular ejection fraction using an ultrasonic stethoscope in critically ill patients. Crit Care 2012, 16: R29. 10.1186/cc11198PubMedCentralCrossRefPubMed Amiel JB, Grumann A, Lheritier G, Clavel M, Francois B, Pichon N, Dugard A, Marin B, Vignon P: Assessment of left ventricular ejection fraction using an ultrasonic stethoscope in critically ill patients. Crit Care 2012, 16: R29. 10.1186/cc11198PubMedCentralCrossRefPubMed
17.
go back to reference Cardim N, Fernandez Golfin C, Ferreira D, Aubele A, Toste J, Cobos MA, Carmelo V, Nunes I, Oliveira AG, Zamorano J: Usefulness of a new miniaturized echocardiographic system in outpatient cardiology consultations as an extension of physical examination. J Am Soc Echocardiogr 2011, 24: 117-124. 10.1016/j.echo.2010.09.017CrossRefPubMed Cardim N, Fernandez Golfin C, Ferreira D, Aubele A, Toste J, Cobos MA, Carmelo V, Nunes I, Oliveira AG, Zamorano J: Usefulness of a new miniaturized echocardiographic system in outpatient cardiology consultations as an extension of physical examination. J Am Soc Echocardiogr 2011, 24: 117-124. 10.1016/j.echo.2010.09.017CrossRefPubMed
18.
go back to reference Frederiksen CA, Juhl-Olsen P, Larsen UT, Nielsen DG, Eika B, Sloth E: New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners. Acta Anaesthesiol Scand 2010, 54: 1217-1223. 10.1111/j.1399-6576.2010.02320.xCrossRefPubMed Frederiksen CA, Juhl-Olsen P, Larsen UT, Nielsen DG, Eika B, Sloth E: New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners. Acta Anaesthesiol Scand 2010, 54: 1217-1223. 10.1111/j.1399-6576.2010.02320.xCrossRefPubMed
19.
go back to reference Lafitte S, Alimazighi N, Reant P, Dijos M, Zaroui A, Mignot A, Lafitte M, Pillois X, Roudaut R, DeMaria A: Validation of the smallest pocket echoscopic device's diagnostic capabilities in heart investigation. Ultrasound Med Biol 2011, 37: 798-804. 10.1016/j.ultrasmedbio.2011.02.010CrossRefPubMed Lafitte S, Alimazighi N, Reant P, Dijos M, Zaroui A, Mignot A, Lafitte M, Pillois X, Roudaut R, DeMaria A: Validation of the smallest pocket echoscopic device's diagnostic capabilities in heart investigation. Ultrasound Med Biol 2011, 37: 798-804. 10.1016/j.ultrasmedbio.2011.02.010CrossRefPubMed
20.
go back to reference Reant P, Dijos M, Arsac F, Mignot A, Cadenaule F, Aumiaux A, Jimenez C, Dufau M, Prevost A, Pillois X, Fort P, Roudaut R, Lafitte S: Validation of a new bedside echoscopic heart examination resulting in an improvement in echo-lab workflow. Arch Cardiovasc Dis 2011, 104: 171-177. 10.1016/j.acvd.2011.01.003CrossRefPubMed Reant P, Dijos M, Arsac F, Mignot A, Cadenaule F, Aumiaux A, Jimenez C, Dufau M, Prevost A, Pillois X, Fort P, Roudaut R, Lafitte S: Validation of a new bedside echoscopic heart examination resulting in an improvement in echo-lab workflow. Arch Cardiovasc Dis 2011, 104: 171-177. 10.1016/j.acvd.2011.01.003CrossRefPubMed
21.
go back to reference Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise J, Solomon S, Spencer KT, St John Sutton M, Stewart W: Recommendations for chamber quantification. Eur J Echocardiogr 2006, 7: 79-108. 10.1016/j.euje.2005.12.014CrossRefPubMed Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise J, Solomon S, Spencer KT, St John Sutton M, Stewart W: Recommendations for chamber quantification. Eur J Echocardiogr 2006, 7: 79-108. 10.1016/j.euje.2005.12.014CrossRefPubMed
22.
go back to reference Jurcut R, Giusca S, La Gerche A, Vasile S, Ginghina C, Voigt JU: The echocardiographic assessment of the right ventricle: what to do in 2010? Eur J Echocardiogr 2010, 11: 81-96. 10.1093/ejechocard/jep234CrossRefPubMed Jurcut R, Giusca S, La Gerche A, Vasile S, Ginghina C, Voigt JU: The echocardiographic assessment of the right ventricle: what to do in 2010? Eur J Echocardiogr 2010, 11: 81-96. 10.1093/ejechocard/jep234CrossRefPubMed
23.
go back to reference Weyman A: Principles and Practice of Echocardiography. 2nd edition. Philadelphia, PA: Lea & Febiger; 1994. Weyman A: Principles and Practice of Echocardiography. 2nd edition. Philadelphia, PA: Lea & Febiger; 1994.
24.
go back to reference Kircher BJ, Himelman RB, Schiller NB: Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol 1990, 66: 493-496. 10.1016/0002-9149(90)90711-9CrossRefPubMed Kircher BJ, Himelman RB, Schiller NB: Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol 1990, 66: 493-496. 10.1016/0002-9149(90)90711-9CrossRefPubMed
25.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307-310.CrossRefPubMed
26.
go back to reference Cohen J: A coefficient of agreement for nominal scales. Educational and Psychological Measurement 1960, 20: 37-46. 10.1177/001316446002000104CrossRef Cohen J: A coefficient of agreement for nominal scales. Educational and Psychological Measurement 1960, 20: 37-46. 10.1177/001316446002000104CrossRef
27.
go back to reference Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 1977, 33: 159-174. 10.2307/2529310CrossRefPubMed Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 1977, 33: 159-174. 10.2307/2529310CrossRefPubMed
28.
go back to reference Prinz C, Voigt JU: Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography. J Am Soc Echocardiogr 2011, 24: 111-116. 10.1016/j.echo.2010.10.017CrossRefPubMed Prinz C, Voigt JU: Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography. J Am Soc Echocardiogr 2011, 24: 111-116. 10.1016/j.echo.2010.10.017CrossRefPubMed
29.
go back to reference Kobal SL, Tolstrup K, Luo H, Neuman Y, Miyamoto T, Mirocha J, Naqvi TZ, Siegel RJ: Usefulness of a hand-carried cardiac ultrasound device to detect clinically significant valvular regurgitation in hospitalized patients. Am J Cardiol 2004, 93: 1069-1072. 10.1016/j.amjcard.2003.12.066CrossRefPubMed Kobal SL, Tolstrup K, Luo H, Neuman Y, Miyamoto T, Mirocha J, Naqvi TZ, Siegel RJ: Usefulness of a hand-carried cardiac ultrasound device to detect clinically significant valvular regurgitation in hospitalized patients. Am J Cardiol 2004, 93: 1069-1072. 10.1016/j.amjcard.2003.12.066CrossRefPubMed
30.
go back to reference Galasko GI, Henein M: Direct access echocardiography. Int J Cardiovasc Imaging 2006, 22: 29-31. 10.1007/s10554-005-0721-5CrossRefPubMed Galasko GI, Henein M: Direct access echocardiography. Int J Cardiovasc Imaging 2006, 22: 29-31. 10.1007/s10554-005-0721-5CrossRefPubMed
31.
go back to reference Filly RA: Is it time for the sonoscope? If so, then let's do it right! J Ultrasound Med 2003, 22: 323-325.PubMed Filly RA: Is it time for the sonoscope? If so, then let's do it right! J Ultrasound Med 2003, 22: 323-325.PubMed
33.
go back to reference Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R, Farina F, Schiattarella PL, Bonito M, Olibet M, de Simone G: Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound 2010, 8: 51. 10.1186/1476-7120-8-51PubMedCentralCrossRefPubMed Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R, Farina F, Schiattarella PL, Bonito M, Olibet M, de Simone G: Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound 2010, 8: 51. 10.1186/1476-7120-8-51PubMedCentralCrossRefPubMed
34.
go back to reference Expert Round Table on Ultrasound in ICU: International expert statement on training standards for critical care ultrasonography. Intensive Care Med 2011, 37: 1077-1083.CrossRef Expert Round Table on Ultrasound in ICU: International expert statement on training standards for critical care ultrasonography. Intensive Care Med 2011, 37: 1077-1083.CrossRef
35.
go back to reference Sievers B, Kirchberg S, Franken U, Puthenveettil BJ, Bakan A, Trappe HJ: Visual estimation versus quantitative assessment of left ventricular ejection fraction: a comparison by cardiovascular magnetic resonance imaging. Am Heart J 2005, 150: 737-742. 10.1016/j.ahj.2004.11.017CrossRefPubMed Sievers B, Kirchberg S, Franken U, Puthenveettil BJ, Bakan A, Trappe HJ: Visual estimation versus quantitative assessment of left ventricular ejection fraction: a comparison by cardiovascular magnetic resonance imaging. Am Heart J 2005, 150: 737-742. 10.1016/j.ahj.2004.11.017CrossRefPubMed
Metadata
Title
Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting
Authors
Matthieu Biais
Cédric Carrié
François Delaunay
Nicolas Morel
Philippe Revel
Gérard Janvier
Publication date
01-06-2012
Publisher
BioMed Central
Published in
Critical Care / Issue 3/2012
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc11340

Other articles of this Issue 3/2012

Critical Care 3/2012 Go to the issue