Abstract

Introduction

Training systems for laparoscopic surgery are useful for basic training but are not suitable for specific training corresponding to the condition of a given patient. We, therefore, have developed an unusual training system: a patient-specific simulator for laparoscopic surgery. When specific data of each individual patient are entered, this system helps surgeons perform a “rehearsal” operation. We applied this technique in laparoscopic surgery by using volume data obtained by multislice computed tomography imaging.

Case presentation

A 39-year-old Japanese woman consulted a doctor because of back pain and underwent pyeloplasty after an examination revealed a ureteropelvic junction obstruction. Computed tomography data showed that the network of arteries and veins was very complicated. Therefore, we decided to use our simulator before performing surgery. Simulation was helpful because we could obtain information about the complicated vessel network and “rehearse” the procedure.

Conclusions

Our simulator allows surgeons to perform a sham operation with different perspectives and tactile sensations and has received favorable reviews from users.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gaur DD: Laparoscopic operative retroperitoneoscopy: use of new device. J Urol. 1992, 148: 1137-1139.PubMed Gaur DD: Laparoscopic operative retroperitoneoscopy: use of new device. J Urol. 1992, 148: 1137-1139.PubMed
2.
go back to reference Brewin J, Nedas T, Challacombe B, Elhage O, Keisu J, Dasgupta P: Face, content and construct validation of the first virtual reality laparoscopic nephrectomy simulator. BJU Int. 2010, 106: 850-854. 10.1111/j.1464-410X.2009.09193.x.CrossRefPubMed Brewin J, Nedas T, Challacombe B, Elhage O, Keisu J, Dasgupta P: Face, content and construct validation of the first virtual reality laparoscopic nephrectomy simulator. BJU Int. 2010, 106: 850-854. 10.1111/j.1464-410X.2009.09193.x.CrossRefPubMed
3.
go back to reference Wijn RP, Persoon MC, Schout BM, Martens EJ, Scherpbier AJ, Hendrikx AJ: Virtual reality laparoscopic nephrectomy simulator is lacking in construct validity. J Endourol. 2010, 24: 117-122. 10.1089/end.2009.0219.CrossRefPubMed Wijn RP, Persoon MC, Schout BM, Martens EJ, Scherpbier AJ, Hendrikx AJ: Virtual reality laparoscopic nephrectomy simulator is lacking in construct validity. J Endourol. 2010, 24: 117-122. 10.1089/end.2009.0219.CrossRefPubMed
4.
go back to reference Maschuw K, Hassan I, Bartsch DK: Surgical training using simulator. Virtual reality. Chirurg. 2010, 81: 19-24. 10.1007/s00104-009-1757-1. In German.CrossRefPubMed Maschuw K, Hassan I, Bartsch DK: Surgical training using simulator. Virtual reality. Chirurg. 2010, 81: 19-24. 10.1007/s00104-009-1757-1. In German.CrossRefPubMed
5.
go back to reference Beyer L, Troyer JD, Mancini J, Bladou F, Berdah SV, Karsenty G: Impact of laparoscopy simulator training on the technical skills of future surgeons in the operating room: a prospective study. Am J Surg. 2011, 202: 265-272. 10.1016/j.amjsurg.2010.11.008.CrossRefPubMed Beyer L, Troyer JD, Mancini J, Bladou F, Berdah SV, Karsenty G: Impact of laparoscopy simulator training on the technical skills of future surgeons in the operating room: a prospective study. Am J Surg. 2011, 202: 265-272. 10.1016/j.amjsurg.2010.11.008.CrossRefPubMed
6.
go back to reference Diesen DL, Erhunmwunsee L, Bennett KM, Ben-David K, Yurcisin B, Ceppa EP, Omotosho PA, Perez A, Pryor A: Effectiveness of laparoscopic computer simulator versus usage of box trainer for endoscopic surgery training of novices. J Surg Educ. 2011, 68: 282-289. 10.1016/j.jsurg.2011.02.007.CrossRefPubMed Diesen DL, Erhunmwunsee L, Bennett KM, Ben-David K, Yurcisin B, Ceppa EP, Omotosho PA, Perez A, Pryor A: Effectiveness of laparoscopic computer simulator versus usage of box trainer for endoscopic surgery training of novices. J Surg Educ. 2011, 68: 282-289. 10.1016/j.jsurg.2011.02.007.CrossRefPubMed
7.
go back to reference Makiyama K, Nagasaka M, Inuiya T, Takanami K, Ogata M, Kubota Y: Development of a patient-specific simulator for laparoscopic renal surgery. Int J Urol. 2012, 19: 829-835. 10.1111/j.1442-2042.2012.03053.x.CrossRefPubMed Makiyama K, Nagasaka M, Inuiya T, Takanami K, Ogata M, Kubota Y: Development of a patient-specific simulator for laparoscopic renal surgery. Int J Urol. 2012, 19: 829-835. 10.1111/j.1442-2042.2012.03053.x.CrossRefPubMed
8.
go back to reference Willaert WI, Aggarwal R, Van Herzeele I, Cheshire NJ, Vermassen FE: Recent advancements in medical simulation: patient-specific virtual reality simulation. World J Surg. 2012, 36: 1703-1712. 10.1007/s00268-012-1489-0.CrossRefPubMed Willaert WI, Aggarwal R, Van Herzeele I, Cheshire NJ, Vermassen FE: Recent advancements in medical simulation: patient-specific virtual reality simulation. World J Surg. 2012, 36: 1703-1712. 10.1007/s00268-012-1489-0.CrossRefPubMed
9.
go back to reference Brooks JD, Kavoussi LR, Preminger GM, Schuessler WW, Moore RG: Comparison of open and endourologic approaches to the obstructed ureteropelvic junction. Urology. 1995, 46: 791-795. 10.1016/S0090-4295(99)80345-8.CrossRefPubMed Brooks JD, Kavoussi LR, Preminger GM, Schuessler WW, Moore RG: Comparison of open and endourologic approaches to the obstructed ureteropelvic junction. Urology. 1995, 46: 791-795. 10.1016/S0090-4295(99)80345-8.CrossRefPubMed
10.
go back to reference Schuessler WW, Grune MT, Tecuanhuey LV, Preminger GM: Laparoscopic dismembered pyeloplasty. J Urol. 1993, 150: 1795-1799.PubMed Schuessler WW, Grune MT, Tecuanhuey LV, Preminger GM: Laparoscopic dismembered pyeloplasty. J Urol. 1993, 150: 1795-1799.PubMed
11.
go back to reference Mathis KL, Wiegmann DA: Construct validation of a laparoscopic surgical simulator. Fall. 2007, 2: 178-182. Mathis KL, Wiegmann DA: Construct validation of a laparoscopic surgical simulator. Fall. 2007, 2: 178-182.
12.
go back to reference Marukawa K, Horiguchi J, Shigeta M, Nakamoto T, Usui T, Ito K: Three-dimensional navigator for retroperitoneal laparoscopic nephrectomy using multidetector row computerized tomography. J Urol. 2002, 168: 1933-1936. 10.1016/S0022-5347(05)64266-8.CrossRefPubMed Marukawa K, Horiguchi J, Shigeta M, Nakamoto T, Usui T, Ito K: Three-dimensional navigator for retroperitoneal laparoscopic nephrectomy using multidetector row computerized tomography. J Urol. 2002, 168: 1933-1936. 10.1016/S0022-5347(05)64266-8.CrossRefPubMed
13.
go back to reference Akiyama Y, Ishifuro M, Ookubo M, Nakashima T, Tamura M, Tsujimura M, Yamaguchi T, Kawamoto Y, Furuta K, Kushima T: Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002, 58: 1682-1686. In Japanese.PubMed Akiyama Y, Ishifuro M, Ookubo M, Nakashima T, Tamura M, Tsujimura M, Yamaguchi T, Kawamoto Y, Furuta K, Kushima T: Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2002, 58: 1682-1686. In Japanese.PubMed
Metadata
Title
Preparation for pyeloplasty for ureteropelvic junction obstruction using a patient-specific laparoscopic simulator: a case report
Authors
Hiroyuki Yamanaka
Kazuhide Makiyama
Tomoyuki Tatenuma
Ryoko Sakata
Futoshi Sano
Yoshinobu Kubota
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2012
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-6-338

Other articles of this Issue 1/2012

Journal of Medical Case Reports 1/2012 Go to the issue