Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2011

Open Access 01-12-2011 | Case report

Successful treatment of a T4 lung tumor with vertebral body invasion using fiducial markers in the thoracic spine for image-guided radiation therapy: A case report

Authors: Anudh K Jain, John Handal, Lawrence J Solin

Published in: Journal of Medical Case Reports | Issue 1/2011

Login to get access

Abstract

Introduction

Paravertebral and paraspinal tumors pose a significant challenge in radiation therapy because of the radiation sensitivity of the spinal cord and the need for maximum treatment accuracy. Implantation of fiducial markers into vertebral bodies has been described as a method of increasing the accuracy of radiation treatment for single-dose stereotactic radiosurgery for spinal and paraspinal primary tumors and metastases. However, utilization of this technique has not been described for conventionally fractionated radiation therapy. This report is the first of its kind in the literature and describes successful treatment of a T4 primary lung tumor with vertebral body invasion with conventionally fractionated, image-guided radiotherapy using fiducial markers implanted in the thoracic spine.

Case presentation

Our patient was a 47-year-old African-American man who presented to our hospital with a history of several months of increasing left arm pain, chest pain, dyspnea on exertion, occasional dry cough, and weight loss. He was found to have stage IIIA T4, N0, M0 lung cancer with vertebral body invasion. He had fiducial markers placed in the thoracic spine for image-guided radiation treatment set-up. The patient received 74 Gy radiation therapy with concurrent chemotherapy, and daily matching of the fiducial markers on the treatment machine allowed for treatment of the tumor while sparing the dose to the adjacent spinal cord. With one year of clinical follow-up, the patient has had regression of the tumor with only asymmetric soft-tissue thickening seen on a computed tomographic scan and grade 1 dyspnea on exertion as the only side effects of the treatment.

Conclusion

Fiducial marker placement is a safe and effective technique for maximizing the accuracy and reproducibility for radiation treatment of lesions near the spinal cord. This technique may be used in conventionally fractionated radiation treatment regimens, such as those employed to treat a lung tumor with vertebral body invasion, to potentially improve clinical outcomes for patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Yamada Y, Lovelock DM, Bilsky MH: A review of image-guided intensity-modulated radiotherapy for spinal tumors. Neurosurgery. 2007, 61: 226-235. 10.1227/01.NEU.0000279970.10309.B5.CrossRefPubMed Yamada Y, Lovelock DM, Bilsky MH: A review of image-guided intensity-modulated radiotherapy for spinal tumors. Neurosurgery. 2007, 61: 226-235. 10.1227/01.NEU.0000279970.10309.B5.CrossRefPubMed
2.
go back to reference Guckenberger M, Meyer J, Wilbert J, Baier K, Bratengeier K, Vordermark D, Flentje M: Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). Radiother Oncol. 2007, 84: 56-63. 10.1016/j.radonc.2007.05.021.CrossRefPubMed Guckenberger M, Meyer J, Wilbert J, Baier K, Bratengeier K, Vordermark D, Flentje M: Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). Radiother Oncol. 2007, 84: 56-63. 10.1016/j.radonc.2007.05.021.CrossRefPubMed
3.
go back to reference Gerszten PC, Burton SA: Clinical assessment of stereotactic IGRT: spinal radiosurgery. Med Dosim. 2008, 33: 107-116. 10.1016/j.meddos.2008.02.003.CrossRefPubMed Gerszten PC, Burton SA: Clinical assessment of stereotactic IGRT: spinal radiosurgery. Med Dosim. 2008, 33: 107-116. 10.1016/j.meddos.2008.02.003.CrossRefPubMed
4.
go back to reference Ryu SI, Chang SD, Kim DH, Murphy MJ, Le QT, Martin DP, Adler JR: Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery. 2001, 49: 838-846.PubMed Ryu SI, Chang SD, Kim DH, Murphy MJ, Le QT, Martin DP, Adler JR: Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery. 2001, 49: 838-846.PubMed
5.
go back to reference Gerszten PC, Ozhasoglu C, Burton SA, Kalnicki S, Welch WC: Feasibility of frameless single-fraction stereotactic radiosurgery for spinal lesions. Neurosurg Focus. 2002, 13: e2-CrossRefPubMed Gerszten PC, Ozhasoglu C, Burton SA, Kalnicki S, Welch WC: Feasibility of frameless single-fraction stereotactic radiosurgery for spinal lesions. Neurosurg Focus. 2002, 13: e2-CrossRefPubMed
6.
go back to reference Edge SB, Byrd DR, Compton CC, Fritz AG, Greene FL, Trotti A, eds, The American Joint Committee on Cancer (AJCC): AJCC Cancer Staging Manual. 2010, New York: Springer, 7 Edge SB, Byrd DR, Compton CC, Fritz AG, Greene FL, Trotti A, eds, The American Joint Committee on Cancer (AJCC): AJCC Cancer Staging Manual. 2010, New York: Springer, 7
7.
go back to reference Kim S, Jin H, Yang H, Amdur RJ: A study on target positioning error and its impact on dose variation in image-guided stereotactic body radiotherapy for the spine. Int J Radiat Oncol Biol Phys. 2009, 73: 1574-1579. 10.1016/j.ijrobp.2008.12.023.CrossRefPubMed Kim S, Jin H, Yang H, Amdur RJ: A study on target positioning error and its impact on dose variation in image-guided stereotactic body radiotherapy for the spine. Int J Radiat Oncol Biol Phys. 2009, 73: 1574-1579. 10.1016/j.ijrobp.2008.12.023.CrossRefPubMed
8.
go back to reference Yin FF, Ryu S, Ajlouni M, Yan H, Jin JY, Lee SW, Kim J, Rock J, Rosenblum M, Kim JH: Image-guided procedures for intensity-modulated spinal radiosurgery. Technical note. J Neurosurg. 2004, 101 (Suppl 3): 419-424.PubMed Yin FF, Ryu S, Ajlouni M, Yan H, Jin JY, Lee SW, Kim J, Rock J, Rosenblum M, Kim JH: Image-guided procedures for intensity-modulated spinal radiosurgery. Technical note. J Neurosurg. 2004, 101 (Suppl 3): 419-424.PubMed
9.
go back to reference Shirato H, Harada T, Harabayashi T, Hida K, Endo H, Kitamura K, Onimaru R, Yamazaki K, Kurauchi N, Shimizu T, Shinohara N, Matsushita M, Dosaka-Akita H, Miyasaka K: Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys. 2003, 56: 240-247. 10.1016/S0360-3016(03)00076-2.CrossRefPubMed Shirato H, Harada T, Harabayashi T, Hida K, Endo H, Kitamura K, Onimaru R, Yamazaki K, Kurauchi N, Shimizu T, Shinohara N, Matsushita M, Dosaka-Akita H, Miyasaka K: Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys. 2003, 56: 240-247. 10.1016/S0360-3016(03)00076-2.CrossRefPubMed
10.
go back to reference Watchman CJ, Hamilton RJ, Stea B, Mignault AJ: Patient positioning using implanted gold markers with the Novalis Body system in the thoracic spine. Neurosurgery. 2008, 62 (5 Suppl): A62-A68.CrossRefPubMed Watchman CJ, Hamilton RJ, Stea B, Mignault AJ: Patient positioning using implanted gold markers with the Novalis Body system in the thoracic spine. Neurosurgery. 2008, 62 (5 Suppl): A62-A68.CrossRefPubMed
Metadata
Title
Successful treatment of a T4 lung tumor with vertebral body invasion using fiducial markers in the thoracic spine for image-guided radiation therapy: A case report
Authors
Anudh K Jain
John Handal
Lawrence J Solin
Publication date
01-12-2011
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2011
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-5-470

Other articles of this Issue 1/2011

Journal of Medical Case Reports 1/2011 Go to the issue