Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2007

Open Access 01-12-2007 | Review

Fixed or mobile-bearing total knee arthroplasty

Authors: Chun-Hsiung Huang, Jiann-Jong Liau, Cheng-Kung Cheng

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2007

Login to get access

Abstract

Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.
Appendix
Available only for authorised users
Literature
1.
go back to reference McEwen HM, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J: The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech. 2005, 38 (2): 357-65. 10.1016/j.jbiomech.2004.02.015.CrossRefPubMed McEwen HM, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J: The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech. 2005, 38 (2): 357-65. 10.1016/j.jbiomech.2004.02.015.CrossRefPubMed
2.
go back to reference Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 1986, 68 (7): 1041-51.PubMed Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 1986, 68 (7): 1041-51.PubMed
3.
go back to reference Sathasivam S, Walker PS: Optimization of the bearing surface geometry of total knees. J Biomech. 1994, 27 (3): 255-64. 10.1016/0021-9290(94)90002-7.CrossRefPubMed Sathasivam S, Walker PS: Optimization of the bearing surface geometry of total knees. J Biomech. 1994, 27 (3): 255-64. 10.1016/0021-9290(94)90002-7.CrossRefPubMed
4.
go back to reference Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD: Mobile-bearing knee replacement- concept and results. Instr Course Lect. 2001, 50: 431-49.PubMed Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD: Mobile-bearing knee replacement- concept and results. Instr Course Lect. 2001, 50: 431-49.PubMed
5.
go back to reference Engh GA: Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report. J Bone Joint Surg Am. 1988, 70 (7): 1093-6.PubMed Engh GA: Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report. J Bone Joint Surg Am. 1988, 70 (7): 1093-6.PubMed
6.
go back to reference Huang CH, Ma HM, Lee YM, Ho FY: Long-term results of low contact stress mobile-bearing total knee replacements. Clin Orthop. 2003, 416: 265-70. 10.1097/01.blo.0000093890.12372.46.CrossRefPubMed Huang CH, Ma HM, Lee YM, Ho FY: Long-term results of low contact stress mobile-bearing total knee replacements. Clin Orthop. 2003, 416: 265-70. 10.1097/01.blo.0000093890.12372.46.CrossRefPubMed
7.
go back to reference Buechel FF, Buechel FF, Pappas MJ, D'Alessio J: Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop. 2001, 388: 41-50. 10.1097/00003086-200107000-00008.CrossRefPubMed Buechel FF, Buechel FF, Pappas MJ, D'Alessio J: Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop. 2001, 388: 41-50. 10.1097/00003086-200107000-00008.CrossRefPubMed
8.
go back to reference Buechel FF: A sequential three-step lateral release for correcting fixed valgus knee deformities during total knee arthroplasty. Clin Orthop. 1990, 260: 170-5.PubMed Buechel FF: A sequential three-step lateral release for correcting fixed valgus knee deformities during total knee arthroplasty. Clin Orthop. 1990, 260: 170-5.PubMed
9.
go back to reference Callaghan JJ, Squire MW, Goetz DD, Sullivan PM, Johnston RC: Cemented rotating-platform total knee replacement. A nine to twelve-year follow-up study. J Bone Joint Surg Am. 2000, 82 (5): 705-11. 10.1302/0301-620X.82B5.9816.CrossRefPubMed Callaghan JJ, Squire MW, Goetz DD, Sullivan PM, Johnston RC: Cemented rotating-platform total knee replacement. A nine to twelve-year follow-up study. J Bone Joint Surg Am. 2000, 82 (5): 705-11. 10.1302/0301-620X.82B5.9816.CrossRefPubMed
10.
go back to reference Ranawat CS, Luessenhop CP, Rodriguez JA: The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am. 1997, 79 (3): 342-8.PubMed Ranawat CS, Luessenhop CP, Rodriguez JA: The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am. 1997, 79 (3): 342-8.PubMed
11.
go back to reference Stern SH, Insall JN: Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Joint Surg Am. 1992, 74 (7): 980-6.PubMed Stern SH, Insall JN: Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Joint Surg Am. 1992, 74 (7): 980-6.PubMed
12.
go back to reference Jacobs W, Anderson P, Limbeek J, Wymenga A: Mobilebearing vs. fixed bearing prostheses for total knee arthroplasty for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev. 2004, 2: CD003130-PubMed Jacobs W, Anderson P, Limbeek J, Wymenga A: Mobilebearing vs. fixed bearing prostheses for total knee arthroplasty for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev. 2004, 2: CD003130-PubMed
13.
go back to reference Kim YH, Kook HK, Kim JS: Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop. 2001, 392: 101-5. 10.1097/00003086-200111000-00013.CrossRefPubMed Kim YH, Kook HK, Kim JS: Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop. 2001, 392: 101-5. 10.1097/00003086-200111000-00013.CrossRefPubMed
14.
go back to reference Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW: A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br. 2003, 85 (1): 62-7. 10.1302/0301-620X.85B1.13233.CrossRefPubMed Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW: A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br. 2003, 85 (1): 62-7. 10.1302/0301-620X.85B1.13233.CrossRefPubMed
15.
go back to reference Rose RM, Goldfarb HV, Ellis E, Crugnola AM: On the pressure dependence of the wear of ultra-high molecular weight polyethylene. Wear. 1980, 181-183. 250–257 Rose RM, Goldfarb HV, Ellis E, Crugnola AM: On the pressure dependence of the wear of ultra-high molecular weight polyethylene. Wear. 1980, 181-183. 250–257
16.
go back to reference Matsuda S, White SE, Williams VG, McCarthy DS, Whiteside LA: Contact stress analysis in meniscal bearing total knee arthroplasty. J Arthroplasty. 1998, 13 (6): 699-706. 10.1016/S0883-5403(98)80016-8.CrossRefPubMed Matsuda S, White SE, Williams VG, McCarthy DS, Whiteside LA: Contact stress analysis in meniscal bearing total knee arthroplasty. J Arthroplasty. 1998, 13 (6): 699-706. 10.1016/S0883-5403(98)80016-8.CrossRefPubMed
17.
go back to reference Stukenborg-Colsman C, Ostermeier S, Hurschler C, Wirth CJ: Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs. Acta Orthop Scand. 2002, 73 (6): 638-46. 10.1080/000164702321039598.CrossRefPubMed Stukenborg-Colsman C, Ostermeier S, Hurschler C, Wirth CJ: Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs. Acta Orthop Scand. 2002, 73 (6): 638-46. 10.1080/000164702321039598.CrossRefPubMed
18.
go back to reference Cheng CK, Huang CH, Liau JJ, Huang CH: The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses- a biomechanical study. Clin Biomech. 2003, 18: 231-6. 10.1016/S0268-0033(02)00189-4.CrossRef Cheng CK, Huang CH, Liau JJ, Huang CH: The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses- a biomechanical study. Clin Biomech. 2003, 18: 231-6. 10.1016/S0268-0033(02)00189-4.CrossRef
19.
go back to reference Sathasivam S, Walker PS, Campbell PA, Rayner K: The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J Biomed Mater Res. 2001, 58 (3): 282-90. 10.1002/1097-4636(2001)58:3<282::AID-JBM1018>3.0.CO;2-S.CrossRefPubMed Sathasivam S, Walker PS, Campbell PA, Rayner K: The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J Biomed Mater Res. 2001, 58 (3): 282-90. 10.1002/1097-4636(2001)58:3<282::AID-JBM1018>3.0.CO;2-S.CrossRefPubMed
20.
go back to reference Wang A, Stark C, Dumbleton JH: Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proc Inst Mech Eng [H]. 1996, 210 (3): 141-55.CrossRef Wang A, Stark C, Dumbleton JH: Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proc Inst Mech Eng [H]. 1996, 210 (3): 141-55.CrossRef
21.
go back to reference Marrs H, Barton DC, Jones RA, Ward IM, Fisher J, Doyle C: Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene. J Mater Sci: Mater in Med. 1999, 10: 333-42. 10.1023/A:1026469522868. Marrs H, Barton DC, Jones RA, Ward IM, Fisher J, Doyle C: Comparative wear under four different tribological conditions of acetylene enhanced cross-linked ultra high molecular weight polyethylene. J Mater Sci: Mater in Med. 1999, 10: 333-42. 10.1023/A:1026469522868.
22.
go back to reference Wimmer MA, Andriacchi TP, Natarajan RN, Loos J, Karlhuber M, Petermann J, Schneider E, Rosenberg AG: A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998, 13 (1): 8-16. 10.1016/S0883-5403(98)90069-9.CrossRefPubMed Wimmer MA, Andriacchi TP, Natarajan RN, Loos J, Karlhuber M, Petermann J, Schneider E, Rosenberg AG: A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998, 13 (1): 8-16. 10.1016/S0883-5403(98)90069-9.CrossRefPubMed
23.
go back to reference Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE: The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop. 2003, 416: 197-207. 10.1097/01.blo.0000092999.90435.d1.CrossRefPubMed Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE: The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop. 2003, 416: 197-207. 10.1097/01.blo.0000092999.90435.d1.CrossRefPubMed
24.
go back to reference Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H: Biomechanics of posterior-substituting total knee arthroplasty: An in vitro study. Clin Orthop. 2002, 404: 214-225. 10.1097/00003086-200211000-00035.CrossRefPubMed Li G, Most E, Otterberg E, Sabbag K, Zayontz S, Johnson T, Rubash H: Biomechanics of posterior-substituting total knee arthroplasty: An in vitro study. Clin Orthop. 2002, 404: 214-225. 10.1097/00003086-200211000-00035.CrossRefPubMed
25.
go back to reference Stiehl JB, Dennis DA, Komistek RD, Keblish PA: In vivo kinematic analysis of a mobile bearing total knee prosthesis. Clin Orthop. 1997, 345: 60-6.CrossRefPubMed Stiehl JB, Dennis DA, Komistek RD, Keblish PA: In vivo kinematic analysis of a mobile bearing total knee prosthesis. Clin Orthop. 1997, 345: 60-6.CrossRefPubMed
26.
go back to reference Stiehl JB, Dennis DA, Komistek RD, Crane HS: In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty. J Arthroplasty. 1999, 14 (3): 293-9. 10.1016/S0883-5403(99)90054-2.CrossRefPubMed Stiehl JB, Dennis DA, Komistek RD, Crane HS: In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty. J Arthroplasty. 1999, 14 (3): 293-9. 10.1016/S0883-5403(99)90054-2.CrossRefPubMed
27.
go back to reference Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA: Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop. 2003, 410: 131-8. 10.1097/01.blo.0000063121.39522.19.CrossRefPubMed Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA: Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop. 2003, 410: 131-8. 10.1097/01.blo.0000063121.39522.19.CrossRefPubMed
28.
go back to reference Catani F, Benedetti MG, De Felice R, Buzzi R, Giannini S, Aglietti P: Mobile and fixed bearing total knee prosthesis functional comparison during stair climbing. Clin Biomech. 2003, 18 (5): 410-8. 10.1016/S0268-0033(03)00044-5.CrossRef Catani F, Benedetti MG, De Felice R, Buzzi R, Giannini S, Aglietti P: Mobile and fixed bearing total knee prosthesis functional comparison during stair climbing. Clin Biomech. 2003, 18 (5): 410-8. 10.1016/S0268-0033(03)00044-5.CrossRef
29.
go back to reference Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M: In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop. 2004, 418: 184-90. 10.1097/00003086-200401000-00030.CrossRefPubMed Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M: In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop. 2004, 418: 184-90. 10.1097/00003086-200401000-00030.CrossRefPubMed
30.
go back to reference Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW: Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop. 2005, 432: 204-9.CrossRefPubMed Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW: Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop. 2005, 432: 204-9.CrossRefPubMed
31.
go back to reference Dennis DA, Komistek RD, Hoff WA, Gabriel SM: In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop. 1996, 331: 107-17. 10.1097/00003086-199610000-00015.CrossRefPubMed Dennis DA, Komistek RD, Hoff WA, Gabriel SM: In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop. 1996, 331: 107-17. 10.1097/00003086-199610000-00015.CrossRefPubMed
32.
go back to reference Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA: Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995, 77 (6): 884-9.PubMed Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA: Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995, 77 (6): 884-9.PubMed
33.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A: A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop. 2004, 428: 180-9. 10.1097/01.blo.0000148777.98244.84.CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A: A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop. 2004, 428: 180-9. 10.1097/01.blo.0000148777.98244.84.CrossRefPubMed
34.
go back to reference Cadambi A, Engh GA, Dwyer KA, Vinh TN: Osteolysis of the distal femur after total knee arthroplasty. J Arthroplasty. 1994, 9 (6): 579-94. 10.1016/0883-5403(94)90111-2.CrossRefPubMed Cadambi A, Engh GA, Dwyer KA, Vinh TN: Osteolysis of the distal femur after total knee arthroplasty. J Arthroplasty. 1994, 9 (6): 579-94. 10.1016/0883-5403(94)90111-2.CrossRefPubMed
35.
go back to reference Ezzet KA, Garcia R, Barrack RL: Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop. 1995, 321: 86-91.PubMed Ezzet KA, Garcia R, Barrack RL: Effect of component fixation method on osteolysis in total knee arthroplasty. Clin Orthop. 1995, 321: 86-91.PubMed
36.
go back to reference Kim YH, Oh JH, Oh SH: Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg Br. 1995, 77 (2): 236-41.PubMed Kim YH, Oh JH, Oh SH: Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg Br. 1995, 77 (2): 236-41.PubMed
37.
go back to reference Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C: Catastrophic osteolysis in total knee replacement. A report of 17 cases. Clin Orthop. 1995, 321: 98-105.PubMed Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C: Catastrophic osteolysis in total knee replacement. A report of 17 cases. Clin Orthop. 1995, 321: 98-105.PubMed
38.
go back to reference Callaghan JJ, O'Rourke MR, Iossi MF, Liu SS, Goetz DD, Vittetoe DA, Sullivan PM, Johnston RC: Cemented rotating-platform total knee replacement. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am. 2005, 87 (9): 1995-1998. 10.2106/JBJS.D.03039.CrossRefPubMed Callaghan JJ, O'Rourke MR, Iossi MF, Liu SS, Goetz DD, Vittetoe DA, Sullivan PM, Johnston RC: Cemented rotating-platform total knee replacement. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am. 2005, 87 (9): 1995-1998. 10.2106/JBJS.D.03039.CrossRefPubMed
39.
go back to reference Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK: Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg Am. 2002, 84 (12): 2224-9.PubMed Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK: Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg Am. 2002, 84 (12): 2224-9.PubMed
40.
go back to reference Huang CH, Ho FY, Ma HM, Yang CT, Liau JJ, Kao HC, Young TH, Cheng CK: Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties – a comparison between mobile bearing and fixed bearing knees. J Orthop Res. 2002, 20 (5): 1038-41. 10.1016/S0736-0266(02)00015-3.CrossRefPubMed Huang CH, Ho FY, Ma HM, Yang CT, Liau JJ, Kao HC, Young TH, Cheng CK: Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties – a comparison between mobile bearing and fixed bearing knees. J Orthop Res. 2002, 20 (5): 1038-41. 10.1016/S0736-0266(02)00015-3.CrossRefPubMed
41.
go back to reference Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK: Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis. Clin Orthop. 2002, 405: 189-94. 10.1097/00003086-200212000-00024.CrossRefPubMed Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK: Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis. Clin Orthop. 2002, 405: 189-94. 10.1097/00003086-200212000-00024.CrossRefPubMed
42.
go back to reference Buechel FF, Pappas MJ: New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings. Orthop Clin North Am. 1989, 20 (2): 147-77.PubMed Buechel FF, Pappas MJ: New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings. Orthop Clin North Am. 1989, 20 (2): 147-77.PubMed
43.
go back to reference Huang CH, Lin GP, Su RY, Lai JH: Dislocation/subluxation of meniscal bearing elements after New Jersey LCS total knee arthroplasty. J Orthop Surg ROC. 1993, 10: 247-53. Huang CH, Lin GP, Su RY, Lai JH: Dislocation/subluxation of meniscal bearing elements after New Jersey LCS total knee arthroplasty. J Orthop Surg ROC. 1993, 10: 247-53.
44.
go back to reference Sorrells RB: Primary knee arthroplasty: Long-term outcomes, the rotating platform mobile bearing TKA. Orthopedics. 1996, 19: 793-6.PubMed Sorrells RB: Primary knee arthroplasty: Long-term outcomes, the rotating platform mobile bearing TKA. Orthopedics. 1996, 19: 793-6.PubMed
45.
go back to reference Bert JM: Dislocation/subluxation of meniscal bearing elements after New Jersey Low-Contact Stress total knee arthroplasty. Clin Orthop. 1990, 254: 211-5.PubMed Bert JM: Dislocation/subluxation of meniscal bearing elements after New Jersey Low-Contact Stress total knee arthroplasty. Clin Orthop. 1990, 254: 211-5.PubMed
46.
go back to reference Huang CH, Young TH, Lee YT, Jan JS, Cheng CK: Polyethylene failure in New Jersey low-contact stress total knee arthroplasty. J Biomed Mater Res. 1998, 39 (1): 153-60. 10.1002/(SICI)1097-4636(199801)39:1<153::AID-JBM17>3.0.CO;2-G.CrossRefPubMed Huang CH, Young TH, Lee YT, Jan JS, Cheng CK: Polyethylene failure in New Jersey low-contact stress total knee arthroplasty. J Biomed Mater Res. 1998, 39 (1): 153-60. 10.1002/(SICI)1097-4636(199801)39:1<153::AID-JBM17>3.0.CO;2-G.CrossRefPubMed
47.
go back to reference Laskin RS: The Genesis total knee prosthesis: A 10-year followup study. Clin Orthop. 2001, 388: 95-102. 10.1097/00003086-200107000-00014.CrossRefPubMed Laskin RS: The Genesis total knee prosthesis: A 10-year followup study. Clin Orthop. 2001, 388: 95-102. 10.1097/00003086-200107000-00014.CrossRefPubMed
48.
go back to reference Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM: Long-term followup of Anatomic Graduated Components posterior cruciate-retaining total knee replacement. Clin Orthop. 2001, 388: 51-57. 10.1097/00003086-200107000-00009.CrossRefPubMed Ritter MA, Berend ME, Meding JB, Keating EM, Faris PM, Crites BM: Long-term followup of Anatomic Graduated Components posterior cruciate-retaining total knee replacement. Clin Orthop. 2001, 388: 51-57. 10.1097/00003086-200107000-00009.CrossRefPubMed
49.
go back to reference Gill GS, Joshi AB, Mills DM: Total condylar knee arthroplasty: 16- to 21-year results. Clin Orthop. 1999, 367: 210-215.CrossRefPubMed Gill GS, Joshi AB, Mills DM: Total condylar knee arthroplasty: 16- to 21-year results. Clin Orthop. 1999, 367: 210-215.CrossRefPubMed
50.
go back to reference Huang CH, Su RY, Lai JH, Hsieh MS: Long-term results of the total condylar knee arthroplasty in Taiwan: A 10 to 15 year follow-up. J Orthop Surg ROC. 1996, 13: 1-10. Huang CH, Su RY, Lai JH, Hsieh MS: Long-term results of the total condylar knee arthroplasty in Taiwan: A 10 to 15 year follow-up. J Orthop Surg ROC. 1996, 13: 1-10.
51.
go back to reference Pavone V, Boettner F, Fickert S, Sculco TP: Total condylar knee arthroplasty: A long-term followup. Clin Orthop. 2001, 388: 18-25. 10.1097/00003086-200107000-00005.CrossRefPubMed Pavone V, Boettner F, Fickert S, Sculco TP: Total condylar knee arthroplasty: A long-term followup. Clin Orthop. 2001, 388: 18-25. 10.1097/00003086-200107000-00005.CrossRefPubMed
52.
go back to reference Ma HM, Lu YC, Ho FY, Huang CH: Long-term results of total condylar knee arthroplasty. J Arthroplasty. 2005, 20 (5): 580-4. 10.1016/j.arth.2005.04.006.CrossRefPubMed Ma HM, Lu YC, Ho FY, Huang CH: Long-term results of total condylar knee arthroplasty. J Arthroplasty. 2005, 20 (5): 580-4. 10.1016/j.arth.2005.04.006.CrossRefPubMed
53.
go back to reference Jordan LR, Olivo JL, Voorhorst PE: Survivorship analysis of cementless meniscal bearing total knee arthroplasty. Clin Orthop. 1997, 338: 119-23. 10.1097/00003086-199705000-00018.CrossRefPubMed Jordan LR, Olivo JL, Voorhorst PE: Survivorship analysis of cementless meniscal bearing total knee arthroplasty. Clin Orthop. 1997, 338: 119-23. 10.1097/00003086-199705000-00018.CrossRefPubMed
54.
go back to reference Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M: A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am. 2005, 87: 2290-6. 10.2106/JBJS.D.02221.CrossRefPubMed Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M: A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am. 2005, 87: 2290-6. 10.2106/JBJS.D.02221.CrossRefPubMed
55.
go back to reference Biau D, Mullins MM, Judet R, Piriou P: Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (10): 927-33. 10.1007/s00167-006-0070-5.CrossRefPubMed Biau D, Mullins MM, Judet R, Piriou P: Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (10): 927-33. 10.1007/s00167-006-0070-5.CrossRefPubMed
56.
go back to reference Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H: Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop. 2005, 29: 179-81. 10.1007/s00264-005-0646-6.PubMedCentralCrossRefPubMed Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H: Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop. 2005, 29: 179-81. 10.1007/s00264-005-0646-6.PubMedCentralCrossRefPubMed
Metadata
Title
Fixed or mobile-bearing total knee arthroplasty
Authors
Chun-Hsiung Huang
Jiann-Jong Liau
Cheng-Kung Cheng
Publication date
01-12-2007
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2007
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-2-1

Other articles of this Issue 1/2007

Journal of Orthopaedic Surgery and Research 1/2007 Go to the issue